Tender For Provn Of Drainage System Near Bldg No A/4/132, A/4/133 & A/4/161 And Provn Of Bathroom Point Near Bldg No A/4/155 Under Ge Panagarh.; 1 Surface excavation n.exc.30 cm deep andaveraging 15 cm deep and getting out in soft/loosesoilincluding clearing away all grass vegetation, saplings, shrubs, brush wood, under growth, roots and trees n. exc. 30cm girth and removing rubbish upto a distance of 50 metre out of the periphery of the area complete all as specified and as directed. 2 Excavating in trenches , n.exc 1.5 m wide and n.exc 1.5 m depth for foundation etc or for shafts, wells, cesspits ,manhole pier hole, laying of cables, pipes etc n.exc 10 sqm on plan and n.exc 1.5m in depth and getting out in any kind of soilNote : Manual excavation to be done. During excavation if any damage occured to existing cable any type/ water pipe line, it will be contractor responsibilty to get it repair and make functional by providing jointing kit etc without any extra cost. Contractor has to repair it within 24 hrs so that essential service can not be effected due to such damage.If contractor fails to repair it within 24 hrs penalty @ Rs 500/- will be charged to contractor. In this GE decision will be final, conclusive and binding. 3 Returning, filling in including spreding,levelling ,watering and well rammingin layers complete all as specified. 4 Removing excavated material (soil) to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and directed. 5 M&L for broken stone or boulder hard core gauge n.exc 63mm deposited, spred and levelled in layers n.exc 15cm thick, watered and rammed to a true surfaces complete all as specified and directed. 6 M & L Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed by Engr-in - charge. 7 M&L for cement concrete type D2 1:4:8 (40mm graded aggregate) in foundations, filling and mass concrete complete all as speicified and directed. 8 M&L cement concrete in fdn filling and mass concrete type C2,1:3:6 (40mm graded aggregate) complete all as specified and directed. 9 M&L PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in coping including form work complete all as specified and directed. 10 M&L PCC1:3:6 type C2 40mm graded agregate as in surface channel and drain etc complete all as specified and directed. 11 M&Lfor forming fair finished drain or channel of manholes inner girth n exc 30cm in cement concrete using extra cement including forms, mould mitered stopped ends etc all as specified complete all as specified and directed. 12 Add or deduct for each 25 mm girth or part thereof over or under 30cm in cement concrete using extra cement including forms, mould mitered stopped ends etc all as specified complete all as specified and directed. 13 M&L Providing precast cement concrete type 1:2:4 type B-1,(20 mm graded aggregate) as in landing, cover slab (for manholes etc) chullah woods, chajjas, water trough mangers, shelves, and similar articles with plain faces complete all as specified and directed. 14 M&L for reinforced cement concrete (Design Mix) M-25 (using 20mm graded stone aggregate) foundations, including rafts, footings, foundation beams, plinth beams; bases for columns, etc. and mass concrete etc complete all as specified and directed. 15 M&L for RCC (Design mix) M-25, using 20 mm graded stone aggregate as in coloums complete all as speicified and directed. 16 M&L for reinforced cement concrete (Design Mix) M-25 (using 20mm graded stone aggregate) in walls, retaining walls, basement walls, ballast walls and the like, any thickness, above top of footings, including attached pilasters and buttress completeall as specified and directed 17 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to sides of footing and plinth beams finished fair and rough complete all as speicified and directed. 18 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to to for coloums complete all as speicified and directed. 19 M&L for Steel Centering and shuttering including strutting, propping etc. and removal of form to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc.; vertical or to batter complete all as specified and directed. 20 M&L Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending pirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speicified and directed. 21 M&L Mild steel TMT bars 8 mm dia and over as instirrups , cut to length, bent to shape required, including cranking, bending pirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as speicified and directed. 22 M&L for brick work with fly ash bricks old size, straight or curved on plan exc 6m mean radius, built in cement mortar 1:6 complete all as speicified and directed. 23 M&L Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement complete all as speicified and directed. 24 M&L for glazed ceramic colour joint free tiles tiles in verticle surface 350x250x7mm thick set and jointed in neat cement slurry over 10 mm thick 1:4 cement mortar plaster and pointed in coloured cement to match complete all as speicified and directed. 25 M&L Non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 but not exceeding 0.18 sqm in floors laid over 15mm thick 1:6 cement mortar screed bed etc. set and jointed in neat cement slurry and pointed in white of coloured cement to match complete all as speicified and directed. 26 M & L for cement concrete 75mm thick 1:4:8, Type D-2 (Using 40 mm graded stone aggregates) as in sub base for flooringetc complete all as specified and directed. 27 M&L cement concrete type B0 (1:2:4) using 12.5 mm graded aggregate 25 mm thick as in floor for receiving screed bed of floor tiling complete all as specified and directed. 28 M&L for preparation of new surface and apply Twocoats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surface complete all as specified and directed 29 S&F Stop valves 15mm dia CP fency type, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as speicified and directed. 30 M&L for steel tubes,15mm dia bore medium grade with all fitting; laidin trenches or wall including all necessary fittings complete all as speicified and directed. 31 M&L for PVC (SWR) floor trap 75mm dia, plain with grating including jointing with solvent cement etc complete complete all as speicified and directed. 32 S&F PVC connection pipe 15mm size & 600mm long with cromium plated brass coupling on both ends suitable for 15mm bore steel tubing complete all as specified and directed. 33 S&F 15mm bore pillar taps cast copper alloy,with capstan heads,chromium plated,screwed down, fancy type high pressure, with or without lettred HOT orCOLD with long screwed sunk and fly nuts complete all as speicified and directed. 34 S&F CP Bib taps 15mm dia, with cfancy handle, screwed down, screwed for iron pipe or for brass ferrule, fency type and fixed complete all as speicified and directed. 35 S&F Tubular towel rail, 20mm dia, D type, brass chromium plated, 60cm long between flanges complete all as speicified and directed. 36 Supply & fix mirror 600mmx 400mm bevelled edge mirror of selected quality glass, mounted on 6 mm thick AC building boardor commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as speicified and directed. 37 S&F PVC connection pipe 15mm size & 600mm long with cromium plated brass coupling on both ends suitable for 15mm bore steel tubing complete all as speicified and directed. 38 E/M PORTIONM & L for concealed point wiring for fan/light point controlled by one one way switchcomplete with 1.5 sq mm FRLSH,PVC insulated multi stranded copper conductor single core cable 1100 volts grade (Red/yellow/blue wires for phases and black wire for neutral),drawn into and including non metalic PVC rigid conduit medium grade of suitable size and conduit accessories fixed on wall, floor, roof etc. and including PVC FRLSH insulated 1.5 sq mm copper conductor for earth continuity (Green Colour)and connected to common earth dollyincluding sunken in GI terminal box2.8 mm thick bakelite hylam sheet cover, ISI marked with CM/L no. for mounting switch & sockets ect.Note : a) Note :- Cost of PVC conduit, cutting chases of wal/ceilingl, making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surfaceare deemed to be included in the quoted rate. 39 All as per item No 38 above but5 Amp socket on same boardwith other switches. 40 All as per item No 38 above but using 4.0 sqmm FRLSH PVC insulated unsheathed multi strand copper cable (1100 V) for line conductor and 4.0 Sqmm FRLSH PVC insulated unsheathed solid copper cable (1100 Volts) for earth continuty wire for one 15/16 amp multi socket out let on independent board. 41 Supply and fix switch piano flush type, single pole , 5/6 Amps, one way complete all as specified. 42 S&Fsocketoutlets 2 in 1, 5 pin, 5/6 Amps flush type 230/240 V complete all as specified and as directed .( For Same Board only) 43 Supply and fixed switch socket combination5 in 1 , 6 pin , (5/16 Amps ) flush typecontrolled by one switch complete all as specified. 44 Supply & fix ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified. 45 Supply and fixing for concealedtype sub main wiring with two run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor (Red/yellow/blue wires for phases and black wire for neutral) drawn in and includingthrough Rigid non-metallic PVC conduit(medium) ISI marked of size 25mm bore with all fittings like tee/Bend/Elbow/Reducer/Bell mouth/Junction / Terminal Boxesetc. and fixing accessories such as coupler, lock nuts, saddles, pipe hook etc.including one run of 6.00 Sqmm single core PVC FRLSH PVC insulated unsheathed stranded copper conductor as earth wire (green in colour) complete all as specified.Note : (i) Note : 2 runs of line conductor,one run of earth continuity conductor, one run of PVCconduit shall be measured as unit length. (ii)Cost of PVC conduit, conductors,making good disturbed wall surfaces including finishing with cement mortor 1:4, matching with existing colour/paint of surface are deemed to be included in the quoted rate. 46 Supply & fixingLED security light 35/36 watt (Min) 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with BIS approved driver and lamp, Aluminum die cast housing High efficiency long life LED package in integral module with lumen efficacy of 115 lm/W (Min) and viewing angle of 45 degree to ensure better uniformity, electronic LED driver (SMPS based constant current supply) with Output Short-circuit protection, Surge protection & other reliability test as perlatest IS. operational voltage of 170 volts to 270 volts, frequency of 50 Hz,protection grade IP 66, IK-08 CRI greater than or equal to 70%, CW available CCT of 5700K/6500K, power factor of minimum 0.95 , life span of minimum 50000 working hours cincluding necessary electrical connections by PVC sheathed copper conductor wireof 3 core x 1.5 Sqmm and necessary fixing arrangement all as specified.Note : (i) The minimum requirement of lumen efficiency, lumen output and power consumption has been specified. However,as per availability, the bidders may opted higher specification with out any extra cost. The quoted rate is deem to be included for that and no extra payment will be made on this account. (ii) The fittings should be marked Date of installation and Date of Procurement with marker pen 47 S&FLED 20 Watt tube light fittingintregatedtype, includingLED retrofit tubelamp 20 W , LED tube light nominal power 20 Watt, LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 110 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 life span of minimum 50000 working hours and LED batten with aluminium housing and polycarbonate diffuser complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingcomplete all as specified & directed..Note (i) Make of batten and LED tube lamp should be of same make. 48 S&F LED 9/10 Watt tube light fitting mirrorintregatedtype, includingLED retrofit tubelamp 9/10 W , LED tube light nominal power 9/10 Watt, L LED wattage of minimum 1 watt each and Maximum 3 watt each, operational voltage of 170 volts to 270 volts, frequency of 50 Hz, , lumen efficacy of minimum 115 lumens per watt, , integrated electronic driver (SMP based constant current supply) with output short circuit protection and surge protection upto 2.5 KV, protection grade IP 20, CRI greater than 80%, bema angle of 120 clear, THD below or less than 20%, CW available CCT of 6500K, power factor of minimum 0.95 extruded aluminium LED battenslife span of minimum 50000 working hours complete fittingincluding connecting with PVC insulated multistranded copper flexible cable 1.0 sqmm three core, and PVC round/ square box white colour x 2 Nos for mounting of fittingincluding taking down old unserviceable complete all as specified & directed.Note : Make of batten and LED tube lamp should be of same make. 49 S & F sheet metal enclosure for MCB, DB, SPN, 240 Volts, 100 Amps rated busbar, Confirming to IS as per IEC 61439-3, 4 way Double door enclosure made up of CRCA sheet steel, RAL 9003 powder coated, IP 43, Ik09 including fixing the DB box flush in wall of any type and making good the distrubed surface to match asthe existing withall as specified and directed . 50 Supply and fixed MCB SPN 32 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 51 Supply and fixed MCB SPN 40 to 63 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 52 Supply and fixed MCB SP 6-32 Amps,C curve 10kA, 240 Volts and to be housed in DBscomplete including necessry connectionall as specified and directed. 53 Material andlabour for earthing complete with Galvanised steel earth plate electrode 600x600x6 mmmm buried directly in ground (Earthpit not less than2.25m below ground level) with top edge of theplate not less than 1.5m below normal groundlevel, connected to GI wire 4 mmasearth lead by means of bolt, nuts, check nutsandwashers of galvanised iron or steel, upto 7.5mlength, earth strip protected by andincluding 15 mm diaGI pipe (light grade) andconnected to main test point or body of pole/pannel or lightening arrester of main controlling switch as directed including concrete pit in PCC(1:3:6)type C1 , Precast RCC(1:2:4)TypeB1 coverslab of size 54x54x5 cm reinforced with 8 mm dia TMT bars @ 100mm C/C bothwayswith onehandle for lifting made out of 10 mm dia TMT bar embedded in precast cover slab, funnel, wire mesh, 20 mm boreGI Pipe (Medium Grade) for watering, Charcoal andsalt in alternate layers of 15 cm (Compacted Thickness) around the earth electrode including necessary excavation, earth work in any typeof soil anddisposal of spoil to a distance n.exc50 m andnecessary testing complete all asshown in Electrical Plate No 3 of SSRPart-I.NOTE : 1. The unit rare includes for protectionh GI pipe of 40mm and watering pipe of 20mm bore including excavation for earth pit in any type of soil/disintegrate rock. 2. Contractor has to bring agriculture soil from outside of defence land and fill in earth pit to acheive desired result as the soil resisitivity is very high. 3. The cost of GI wire of 32x6mm including protection pipe,from top of earth plate upto 7.5 meter above/below ground level is deemed to be included in the unit rate. 4. All the joints in GI strip and connectgion with earth plate to be welded through brazing and in addition by providing double brass nut bolt and washer. 5.Costing of welding and nut bolts are deemed to be included in the unit rate 54 Material and labour for laying of GI tubing25 mm bore, medium grade, ISI marked, conforming to IS 1239 (Part-1): 2004 including all fittings conforming to IS 1239 (Part-2): 2011 like elbow, socket, tee, reducer, nipple, short piece, union etcas required at site and laid in trenches incl connecting with existing lines all as directed by Engr-in-charge.Note:(i) Union or long screw have to provided at starting / end point of jointing pipe line . 55 Supply& fixedgun metal ,gate valve, 25 mm dia with iron wheel head, screwed both ends for iron pipe and fix complete all as specified and directed. 56 S & F rotational moulded polyethylene ISI marked (vertical cylindrical with close top) as per IS 12701: 1996 of 500 litres capacity hoisted and fixed in position with and including Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for 25mm bore dia iron pipe, provision of 25 mm dia medium grade GI pipe for connecting inlet, outlet, over flow and washout pipes including dismantling the existing one and removing to store complete all as specified and as directed.