}

Tender For Improvement And Development Of Electrical Installation And Fans For Arogya Mandir At Dev Nagar Dipensary Under Karol Bagh Zone., karol-Delhi

Municipal Corporation Of Delhi has published Tender For Improvement And Development Of Electrical Installation And Fans For Arogya Mandir At Dev Nagar Dipensary Under Karol Bagh Zone.. Submission Date for this Tender is 25-07-2025. Street Lighting Tenders in karol Delhi. Bidders can get complete Tender details and download the document.




Tender Notice

50238020
Tender For Improvement And Development Of Electrical Installation And Fans For Arogya Mandir At Dev Nagar Dipensary Under Karol Bagh Zone.
Tender
Indian
Delhi
Karol
25-07-2025

Tender Documents

Tender Details

Tender For Improvement And Development Of Electrical Installation And Fans For Arogya Mandir At Dev Nagar Dipensary Under Karol Bagh Zone.; 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 2 Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/recessed PVC conduite along with 1 no 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 3 Wiring for circuit/submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor,single core cable in surface/recessed PVC conduit as required..2x2.5 sq.mm +1x2.5 sq.mm earth wire 4 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required.Group C 5 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm 6 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3 x 2.5 sq. Mm 7 Supplying and drawing following sizes of FRLSPVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required.3x 4 sq. Mm 8 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25MM 9 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.5/6 A switch 10 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 A switch 11 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 A socket outlet 12 Improvement and Developement ofElectrical installation 13 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 14 Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required.6Module (200mmX75mm) 15 Supplying and fixing following size/ modules, GI box alongwithmodular base & cover plate for modular switches in recess etc.as required.12 Module (200mmX150mm) 16 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 17 Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required. 18 Installation of exhaust fan in the existing opening, includingmaking good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 19 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).8 way , Double door 20 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator).12 way , Double door 21 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 22 Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A 23 Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc with charcoal/ coke and saltas required. 24 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 25 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. Mm 26 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required. Upto 35 sq. Mm (clamped with 1mm thick saddle) 27 LED Batten light (System lumen efficacy ≥105 <120 lm/Watt) Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM(Standard Deviation Color Matching) <3, Maximum power consumption should not more than thespecified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not rise above 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm)18- 22 watt 28 LED Street light fixture, powder coated pressure die castaluminum body (System lumen efficacy >135 lm/Watt)Supplying, installation, Testing & Commissioning of Street light LEDfixture, powder coated pressure die cast aluminum body with built in or separate driver as per the requirement with Driver efficiency >85%, Input voltage: 140-270 Volt AC, freq 50/60 hz, Operating temp range -15 deg to 50deg centigrade, internal surge protection of 5 KV L,N,E as per IEC 61000-4- 5, Driver efficiency >85%,THD < 10% as per IEC 61000-3-2 , P. F.≥0.95, IP- 66,IK-10, CRI >80 , under voltage and over voltage protection,EMIEMCas per CISPR-15, lenses for beam angle as per IESNA type I/II/III as per the width of the road and the project requirement., suitable to fit in up to 65mm dia pipe, life time (LED,Driver & electrical circuitry) of minimum 50000 Burning Hours with 70% of initial Lumen maintained till lifeends as per LM80 extrapolation IES TM-21-11 report , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , SDCM(Standard Deviation Color Matching) <5, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy >135 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing requiredfor LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junctiontemperature shall not rise above 90°C).72 watt 29 Supply of ceiling fan with Brush Less Direct Current (BLDC) Motor, class ofinsulation: B, 3 nos. metal( Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body PowerFactor not less than 0.9, Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and allremaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS374:2019 fan Supply, earthing etc. complete as req.1200mm, BEE 5 star rating, service value ≥ 6.0 CM/Min/Watt, air delivery 210 CM/Min (Minimum) 30 Supply of 12 (300mm)sweep 1400 rpm exhaust fan heavy duty complete with shutters blades etc as reqd 31 Supply of XLPE insulated,PVC sheathed Al.conductor Armoured Cable1.1KV grade Conforming to IS 7098/1988 of following Sizes (a)2X6 SQmm 32 SITC of window type Air conditioner fitted with rotary compressor of 1.5 Ton capacity, BEE 5 star rating complete as required. 33 S/I/T/C of 4 KVA Voltage Stabilizer having input voltage 150V-270V and output voltage 195-245V 34 SITC of wall mounted fan 400mm sweep rated voltage 220-230 AC rated frequency 50HZ speed 1280-1350 RPM with desired color 35 SITC of single/ three phase monoblock pump set complete with all accessories workable on 240/415 volts, 50 Hz ac supply (a) 1 HP (0.75 KW) single phase pump set, head from 12-30 metre suction and delivery 25×25 mm. 36 supply and fixing of 4.5 KG DCP with CO2 gas cartridge fire extinguisher (conforming to IS:2171 with cylinder fully charged) 37 S/I/T/C of 2MP fixed lensDOME IP Camera with following specifications:-Image Sensor: 1/32MP CMOS or better**Minimum Illumination: 0.08 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate:1-25 fps or better **Lens: 2.8 FixedVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (1920x1080) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 25mOperating Temperature: -20 to 55 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL. 38 S/I/T/C of 4MP fixed lens Bullet IP Camera with following specifications:-Image Sensor: 1/3 4MP CMOS Minimum Illumination: 0..05 lux color, 0 lux with IR or better **Shutter Speed:1/3 – 1/100,000 sFrame Rate:20 fps or better **Lens: 3.6 to 10mm Varifocal lensVideo Compression: H.265 or better **S/N Ratio: >45dBResolution: (2650x1440) or better **Protocol: should comply to IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNS, IEEE802.1XIR Range: Minimum 30mOperating Temperature: -20 to 55 deg CentWeatherproof Standard:IP66 or better **Safety standard: UL. 39 SITC of 8 channel NVR with the following specifications:Camera resolution:upto8MPInterface: 1 HDMI, 1VGA minimumCompression :H.265or betterNetwork Throughput :80Mbps or better**USB Port: 2 USB port (USB2.0)minimumHard disk interface: 1 SATA port suitable for 6TB eachProtocol: IPv4/v6, TCP/IP, HTTP, HTTPS, FTP, PPPoE,DDNSOperating temp: -10 to 55 deg CentSafety standard: UL 40 SITC of 6 TB surveillance HDD 41 SITC of 8 port Giga PoE switch, 8(PoE 10/100) + 2(10/100) port long distance switch 42 S/I/T/C of full HD LED Monitor,32inchescomplying to with following specifications:Resolution : Full HD : 1920 x 1080 or betterBacklight : LEDBrightness : 300 NITS min.Contrasts :1200:1 or betterPower supply : 230v + / - 10%, 50 Hzat sitewith connections andalong with all accessories completeas required. 43 SITC of pigtails 1 meter with spilicing and testing 44 SITC of LIU Boxes complete with all accessories etc as required of 12 port 45 Supply Installation testing Commissioning of following wall/ standing M.S powder coated rack with glass front door, fan, steel rear door,power supply, MCB, cable manager, drawer shelves and wiring channels to accommodate CCTV systems equipment and complete with accessories as reqd.17 U 46 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 47 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable 48 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 3 run of cable

Key Value

Document Fees
INR 590 /-
EMD
INR 7400.0 /-
Tender Value
INR 3.67 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail