}

Urgent Repair/Renovation And Addition/Alteration Of Different Residential/Office Buildings Falling Under The Jurisdiction Of Pwd (R&B) Division Gandoh For The Financial Year 2025-26., Doda-Jammu And Kashmir

Road And Building Department has published Urgent Repair/Renovation And Addition/Alteration Of Different Residential/Office Buildings Falling Under The Jurisdiction Of Pwd (R&B) Division Gandoh For The Financial Year 2025-26.. Submission Date for this Tender is 25-07-2025. Building Work Tenders in Doda Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50234943
Urgent Repair/Renovation And Addition/Alteration Of Different Residential/Office Buildings Falling Under The Jurisdiction Of Pwd (R&B) Division Gandoh For The Financial Year 2025-26.
Tender
Indian
Jammu And Kashmir
Doda
25-07-2025

Tender Documents

Tender Details

Urgent Repair/Renovation and Addition/Alteration of different Residential/Office buildings falling under the Jurisdiction of PWD (R&B) Division Gandoh for the Financial year 2025-26.- 1 Demolishing R.C.C. work manually/by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge. 2 Extra for cutting reinforcement bars manually / by mechanical means in RCC or R.B work (payment shall be made on the cross sectional area of RCC or R.B Work) 3 Extra for scrapping, cleaning and straightening reinforcement from R.C.C. or R.B. work 4 Demolishing brick work manually/by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 meters lead as per direction of Engineer-in-charge: In cement mortar 5 Removing mortar from bricks and cleaning bricks incl. stacking with a lead of 50 Mtrs (Stacks of cleaned bricks shall be measured) from brick work in cement mortar 6 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead Of area of 3 sqm. and below 7 Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 meters lead Of area beyond 3 sqm 8 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters leadOf area of 3 sqm. and below 9 Taking out doors, windows and clerestory window shutters (steel or wood) including stacking within 50 meters leadOf area beyond 3 sqm. 10 Demolishing brick tile covering in terracing including stacking of serviceable material and disposal of unserviceable material within 50 meters lead. 11 Demolishing mud phaska in terracing and disposal of material within 50 meters lead 12 Repairs to plaster of thickness 12mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 meters lead With cement mortar 1:4 (1 cement : 4 fine sand) 13 Renewing glass panes, with putty and nails wherever necessary including raking out old puttyFloat glass panes of thickness 4.0 mm(weight not less than 10kg/sqm) 14 Renewing glass panes, with putty and nails wherever necessary including raking out old puttyFloat glass panes of thickness 5.0 mm(weight not less than 12.5 kg/sqm). 15 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) 16 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) with 20% boulder. 17 Providing and laying in position cement concrete of specified grade including curing but excluding the cost of centring and shuttering. All work upto plinth level with:1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) 18 Providing and laying in position specified grade of reinforced cement concrete including curing but excluding the cost of centering, shuttering, finishing and reinforcement. All works upto plinth level 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 5.3.1 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) 20 Extra for brick work/tile brick/AAC block masonry in superstructure above floor V level for each four floors or part thereof by mechanical means: 21 Centering and shuttering including strutting, propping etc. and removal of form for: Walls (any thickness) including attached pilasters, buttresses, plinth andstring courses etc. 22 Centering and shuttering including strutting, propping etc. and removal of form for: Lintel, beams, plinth beams, girders, bressumers and cantilevers. 23 Centering and shuttering including strutting, propping etc. and removal of form for: Columns, pillars, piers, abutments, posts and struts. 24 Centering and shuttering including strutting, propping etc. and removal of form for: Edges of slabs and breaks in floors and walls Under 20 cm wide 25 Providing and fixing M.S tubular frames for doors, windows, ventilators and cupboard with rectangular /L-type sections, made of 1.60 mm thick M.S Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10cm long embedded in cement concrete blocks 15x10x10cm of C.C. 1:3:6 (1cement : 3 coarse sand :6 graded stone aggregate 20mm nominal size) . 26 Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Welded 27 Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting , hoisting , fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. 28 Regrading terracing of mud phaska covered with tiles or bricks, in cement by dismantling tiles or bricks, removing mud plaster, preparing the surface of mud phaska to proper slope, relaying mud plaster gobri leaping and tiles or bricks, grouted in cement mortar 1:3 (1 cement: 3 fine sand), including replacing unserviceable tiles or bricks with new ones and disposal of unserviceable material to the dumping ground (the cost of the new tiles or brick excluded) within 50 meters lead. 29 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or re plastering, including disposal of rubbish to the dumping ground within 50 meters lead. 30 Raking out joints in lime or cement mortar and preparing the surface for re-pointing or re plastering, including disposal of rubbish to the dumping ground within 50 meters lead.Old work (one or more coats) 31 Distempering with 1st quality Acrylic/oil bound washable distemper (ready-made) having VOC content less than 50 grams/litre of approved manufacturer and of required shade and colour complete as per manufacturers’ specifications, one or more coats on old work 32 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. 33 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade, one or more coats on old work. 34 15mm Cement plaster on the rough side of single or half brick wall of mix:1 : 4 ( 1 cement : 4 fine sand) 35 12mm Cement plaster of mix: 1 : 4 ( 1 cement : 4 coarse sand) 36 12mm Cement plaster of mix: 1 : 6 ( 1 cement : 6 coarse sand) 37 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface. 38 Finishing walls with water proofing cement paint of required shade: Old work (one or more coats applied @ 2.20 kg/10sqm) over priming coat of primer applied @ 0.80 liters/10sqm complete including cost of priming coat. 39 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade.Two or more coats on new work 40 Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 1 mm thick 41 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven storey height made with 40 mm dia M.S. tube 1.5 m centre to centre horizontal and vertical tubes joining with cup and lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffoldings for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connection with the building etc. wherever required for inspection of work at required locations with essential safety features for the workmen etc complete as per directions and approval of Engineer-in-charge. The elevational area of the scaffolding shall be measured for payment purpose. The payment will be made once irrespective of duration of scaffolding. 42 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work (Parkash, Suyra Make) or equivalent (exposed on wall) 15 mm dia. nominal bore (Medium) 43 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work (Parkash, Suyra Make) or equivalent (exposed on wall) 20 mm dia. nominal bore (Medium) 44 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work (Parkash, Suyra Make) or equivalent (exposed on wall) 25 mm dia. nominal bore (Medium) 45 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.: Internal work (Parkash, Suyra Make) or equivalent (exposed on wall) 32 mm dia. nominal bore (Medium) 46 Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Parkash, Suyra Make) or equivalent15 mm dia. nominal bore (Medium) 47 Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Parkash, Suyra Make) or equivalent20 mm dia. nominal bore (Medium) 48 Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Parkash, Suyra Make) or equivalent25 mm dia. nominal bore (Medium) 49 Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Parkash, Suyra Make) or equivalent32 mm dia. nominal bore (Medium) 50 Providing and fixing G.I. pipes complete with G.I. fittings excluding trenching and refilling etc. (external work) (Parkash, Suyra Make) or equivalent40 mm dia. nominal bore (Medium) 51 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) (Uniqu/DRP make) 15 mm nominal bore 52 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) (Uniqu/DRP make) 20 mm nominal bore 53 Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (new work) (Uniqu/DRP make) 25 mm nominal bore 54 Providing & fixingwater closet squrating pan (Indian type W.c pan) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.C.V flushing cistern, including flush pipe (of approved make) with manually controlled device (handle ever) conforming to IS: 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required. White vitreous china Orissa pattern W.C pan of size 580 x 440 mm with integral type foot rests. 55 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar taps 56 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required : White Vitreous China Flat back wash basin size 550x400 mm with single 15 mm C.P. brass pillar tap. 57 Providing and fixing wash basin with C.I. brackets, 15mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever required :Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings 58 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265mm sizes respectively. 59 Providing and fixing P.V.C low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete: 10 liter capacity -White 60 Providing and fixing solid plastic seat with lid for pedestal type W.C. pan complete: White solid plastic seat with lid 61 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-Charge and finished smooth. White Agaria Marble Stone (18mm) 62 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per I.S. 13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink without drain board 610x460mm bowl depth 200mm 63 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Semi rigid pipe 32 mm dia 64 Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C waste fittings complete:Flexible pipe 32 mm dia 65 Providing and fixing PTMT pillar cock of approved quality and colour. 15 mm nominal bore, 107 mm long, weighing not less than 110 gms. 66 Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore 125 mm long foam flow, weighing not less than 120 gms. 67 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid , 10 liter low level white vitreous china flushing cistern and CP flush bend with fittings and C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid. (Jaquor/Cera make) 68 Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:-(a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CP Brass single hole basin mixer (Jaquor/Cera make) 69 Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. (Jaquor/Cera make) 70 Providing and fixing 15 mm nominal bore C.P. brass bib cock of approved quality conforming to IS : 8931 (Jaquor/Cera make) 71 Providing and fixing 15mm C.P hand shower for W.C of good quality(Jaquor/Cera make) 72 Providing and fixing 15 mm nominal bore C.P. brass angle valve for basin mixer and geyser points of approved make conforming to IS : 8931 (Jaquor/Cera make) 73 Providing and fixing 15 mm nominal bore C.P. brass long body bib cock of approved quality conforming to IS standards and weighing not less than 690 gms(Jaquor/Cera make) 74 Providing and fixing 15 mm nominal bore of standard back type C.P. brass close hole basin mixer pillar tap of approved quality and make, weighing not less than 1.970 kg. (Jaquor/Cera make) 75 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand (zone- III) : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand (zone- III) : 8 graded stone aggregate 40 mm nominal size),inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4graded stone aggregate 20 mm nominal size) finished with a floating coat of neat cement complete as per standard design : Inside size 90x80 cm and 45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 76 Extra for depth for manholes Size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 77 Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 455x610 mm and 45 cm deep for single pipe line- 78 Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design :Inside dimensions 500x700 mm and 45 cm deep for single pipe line with one or two inlets 79 Constructing brick masonry chamber for underground C.I. inspection chamber and bend with common burnt clay (non modular) bricks of class designation 7.5 in cement mortar 1:4 ( 1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg ) R.C.C. top slab with 1:1 ½ : 3 mix ( 1 cement : 1 ½ coarse sand : 3 graded stone aggregate 20 mm nominal size),foundation concrete 1:5:10 (1 cement: 5 fine sand: 10 graded stone aggregate 40mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 ( 1 cement : 3 coarse sand) finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design : Inside dimensions 600x850 mm and 45 cm deep for single pipe line with three or more inlets. 80 FProviding and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections 1.63 mm (14 G) thick shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)or fixed portion. Anodized aluminum (Anodized transparent or dyed to requiredshade according to IS:1868, minimum anodic coating of grade AC 15) 81 Powder coated aluminum (minimum thickness of powder coated 50 microns)Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections 1.63 mm (14 G) thick shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.) 82 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections 1.63 mm (14 G) thick shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately.) Anodized aluminum (Anodized transparent or dyed to required shade according to IS:1868, minimum anodic coating of grade AC 15) 83 Providing and fixing aluminum work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixed with dash fastener of required dia. and size including necessary filling up of gaps at junctions i.e, at top, bottom and sides with required EPDM rubber / neoprene gasket felt etc. Aluminum sections 1.63 mm (14 G) thick shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminum snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge (glazing, panelling and dash fasteners to be paid for separately.)Powder coated aluminum (minimum thickness of powder coated 50 microns) 84 Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge.Pre-laminated particle board with decorative lamination on both sides. 85 Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side. 86 Providing and fixing 12mm thick prelaminated particle board flat pressed three layer or graded wood particle board (conforming to IS: 12823 Grade-I type-II) in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-incharge.Repair to aluminium door shutters incl. refixing / fixtures / ACP sheets rubber gasket / aluminium beeding etc complete (Cost of ACP sheet paid separtely) 87 Providing and fixing glazing in aluminum door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in- charge. (Cost of aluminum snap beading shall be paid in basic item.) With float glass panes of 5.0 mm thickness (weight not less than 12.50 kg / sqm) 88 Providing and fixing double action hydraulic floor spring of approved brand and manufacture IS : 6315 marked, having brand logo embossed on the body/plate with double spring mechanism and door weight upto 125 kg for doors including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in- plate etc. complete as per the direction of Engineer-in-charge. With Stainless Steel cover plate minimum 1.25 mm thickness 89 Providing and fixing Brass 100mm mortice latch and lock with 6levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete. 90 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6mm, with 40mm dia, steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer 91 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately).Second class Kail wood (30mm thick) 92 Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: -Butt hinges and necessary screws shall be paid separately). Second class Kail wood (35mm thick) 93 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Particle Board 12mm thick. Plain particle board flat pressed, 3 layer or graded wood particle board medium density Grade I, IS : 3087 marked 94 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side, Grade I, Type II IS : 12823 marked 95 Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick.Pre-laminated particle board with decorative lamination on both sides, Grade I, Type II IS : 12823 marked 96 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class Kail wood 50 x 12 mm 97 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete: 2nd class Kail wood50 x 20 mm 98 Providing and fixing wooden moulded corner beading of size 50x50 mm (base and height) of triangular shape to the junction of paneling etc. with iron screws, plugs and priming coat on unexposed surface etc. complete. Second class kail wood 99 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm diax40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimetre channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Chargebut excluding the cost of painting with:8 mm thick Calcium Silicate Board made with Calcareous and Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process. 100 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS:277 and consisting of angle cleats of size 25 mm widex1.6mm thick with flanges of 27mm and 37 mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm diax40mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.5mm of required length with nuts & bolts of required size and other end of angle hanger fixed with G.I. channels 45x15x0.9 mm running at the spacing of 1200 centre to centre, to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26 mm each having clips of 10.5 mm at 450mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64mm diaX230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre to centre, with 25mm long drive-all screws @ 230 mm interval ,including fixing of gypsum board/calcium silicate board to ceiling section and perimetre channel with the help of dry wall screws of size 3.5x25mm at 230mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the gypsum board with recommended jointing compound, jointing tapes, finishing with jointing compound in 3 layers covering upto 150mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers’ specification and also including the cost of making openings for light fittings, grills diffusers, cutouts made with frame of perimetre channels suitably fixed all complete as per drawing and specification and direction of the Engineer-in-Chargebut excluding the cost of painting with:12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard manufactured from natural gypsum as per IS 2095 part-I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. 101 Providing and laying water proofing treatment on Roofs of slabs by applying Chryso TAPELASTIC -consisting of following operations: -a) Cleaning of RCC to remove dust and loosely adhering particles completely. Fill the Pinholes, visible cracks and gaps of pipe with polymer repair mortar 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE. Application of 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE - as a coving at the corners of floor and the vertical surface in the sunken area, and between floor and walls in the remaining area. After surface preparation, first layer of CHRYSO TAPELASTIC - Two component Elastomeric high performance cementitious waterproof coating @ 0.750 gram per /sqm..b) Laying and sandwich layer of Fibre glass cloth when the first coating is still green. c) Second layer of 1.5 mm thickness Chryso TAPELASTIC - Two component Elastomeric high perfornamce cementitious waterproof coating @ 0.750 kg/sqm. This will be allowed to air cure for 4 hours followed by water curing for 48 hours. The entire treatment will be taken upto 30 cm on parapet wall.d). Providing and laying screed concrete (1:2:4) of 50 mm thickness admixed with Chryso STRUCO EXCEL - Intergal waterproofing compound over the CHRYSO TAPELASTIC applied surface on roof, so as to achieve a minimum slope of 1:100 for proper run off of rain water. Minimum thickness near the rain water pipes should be 25 mm. Proper care to be taken while placing screed concrete so as to ensure that the waterproofing membrance is not ruptured. 102 Providing and Laying water proofing treatment in Sunken Portion of WC, bathroom etc by applying CHRYSO TAPELASTIC consisting of following operations : - face preparation Cleaning of RCC to remove dust and loosely adhering particles completely.b) Fill the Pinholes, visible cracks and gaps of pipe with polymer repair mortar 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE.c) Application of 1:2:4 cement - sand mortar, mixed with CHRYSO ARMOURCRETE -as a coving at the corners of floor and the vertical surface in the sunken area, and between floor and walls in the remaining area.Application of first coat fo CHRYSO TAPELASTIC -Two component Elastomeric high performance Cementitious Waterproof coating CHRYSO TAPELASTIC - It comes with 2 pack system A pack is polymer and pack B iscement filler to be mixed as per tiechnical data sheet.Waterproof coating onto the prepared surface form continuous film on the floor of the sunken area. Apply second coat of Chryso TAPELASTIC - Two component Elastomeric high performance cementitious Waterproof coating after 5 to 6 hours to first coat take the coating over the vertical surfaces on to the floor and over the coving on to the wall (before tiling) to at least 300 mm above the final finished floor level. The coating shall also be continued on to the inner surfaces of the pipe penetration holes. Two coats shall be applied @ 1.5 kg per/sqm in two coats.d). Curing after application of CHRYSO TAPELASTIC - Two component Elastomeric high performance cementitious waterproof coating initial air drying shall be done for 3-6 hours. During this period, no water should be used orcuring. After a maximum period of 6-8 hours after the final application, moist curing shall be done for the next 2-3 days, either by spraying water or by using wet burlap. During this period, the CHYRSO TAPELASTICcoating at no point of time should be left completely dry or submerged in water. After the moist curing the Chryso TAPELASTIC - Two component Elastomeric high performance cementitious waterproof coating shall be allowed to air dry for 3 days before submersion in water.e). Providing a 12 mm thick cement-sand plaster (1:4) on the water proofing coating by mixing an integral waterproffing compound, CHRYSO STRUCO EXCEL @ 200 GM per bag of cement. 103 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours and shades, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), including grouting the joint with white cement and matching pigments etc. complete. Size of tile 600x600 mm 104 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per direction of Engineer-in-charge In flooring on a bed of 10mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) 105 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding and joints filled with acid and/or alkali resisting cement as per IS:4457, complete as per direction of Engineer-in-charge In dado/skirting on 12mm thick mortar 1:4(1 acid proof cement : 4 coarse sand) 106 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In colour such as White, Ivory, Grey, Fume Red Brown 107 Providing and laying Ceramic glazed floor tiles 300x300 mm (thickness to be specified by the manufacturers) of 1st quality conforming to IS: 15622 of approved make, laid on 20 mm thick bed of cement mortar 1: 4 ( 1 cement : 4 coarse sand) including pointing the joints with white cement and matching pigment etc., complete.In all colours, shades, except White, Ivory, Fume Red Brown 108 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.n colour such as White, Ivory, Grey, Fume Red Brown 109 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, laid on 20 mm thick cement mortar 1:4 (1Cement : 4 Coarse sand), including grouting the joints with white cement and matching pigments etc., complete.In all colours, shades, except White, Ivory, Fume Red 110 Kota stone slab 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm ( average) thick cement mortar 1:3 (1 cement:3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing, polishing and curing complete 111 Disposal of unserviceable dismentled material / waste mulba by mechanical transportation outside Municipal limits incl. cost of loading, unloading, stacking complete (Trolly) 112 Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent. 113 Providing edge moulding to 18 mm/16 mm thick marble stone counters, Vanities etc. including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge. (Grantine work) 114 Extra for providing frosted glass panes 4 mm thick instead of ordinary float glass panes 4 mm thick in doors, windows and clerestory window shutters. (Area of opening for glass panes excluding portion inside rebate shall be measured) 115 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer all complete Fixed to steel windows by welding 116 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc including priming coat with approved steel primer al l completeFixed to openings / wooden frames with rawl plugs screws etc 117 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 15mm nominal bore 118 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete 20mm nominal bore 119 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia and length (hold fast lugs or with dash fasteners shall be paid for separately): Second class Kail wood 120 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.15mm nominal outer dia pipes 121 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot and cold water supply, including all CPVC plain and brass threaded fittings. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-charge. Internal work Concealed fixing the pipe with clamps at 1.00 meter spacing including cutting chases and making good the wall etc.25mm nominal outer dia pipes 122 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)25 mm nominal bore 123 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)32 mm nominal bore 124 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)40 mm nominal bore 125 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end)50 mm nominal bore 126 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required0.63 mm thick with zinc coating not less than 275 gram/m2 127 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requiredSupply of Labour (Mazdoor) for various day to day works as per directions of engineer in charge 128 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requiredSupply of Labour (Mason) for various day to day works as per directions of engineer in charge 129 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requiredSupply of CARPANTER for various day to day works as per directions of engineer in charge 130 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requiredSupply of PLUMBER for various day to day works as per directions of engineer in charge 131 Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal / vertical or curved surface) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever requiredSupply of Welder for various day to day works as per directions of engineer in charge. 132 Providing and fixing 18 mm thick, 150 mm wide pelmet of coir veneer board ISI marked IS: 14842-2000, including top cover of 6mm coir veneer board, nickel plated M.S. pipe 20 mm dia (heavy type) curtain rod with nickel plated brackets including fixing with 25x3 mm M.S. flat 10 cm long fixed to pelmet with hollock wood cleats of size 100mm x 40mmx40 mm on both inner side of pelmet and rawl plugs 75mm long etc. all complete. 133 Providing and fixing aluminum extruded section body tubular type universal hydraulic door closer,(having brand logo with IS: 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessary accessories and screws etc. complete : 134 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 1 meter from cutting edgeAll kinds of soil : 135 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 1 meter from cutting edgeOrdinary Rock 136 Earth work in excavation by manual means in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed: 1 meter from cutting edgeHard Rock (Blasting prohibited ) 137 Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:All kinds of soil : 138 Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:Ordinary Rock 139 Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres:Hard Rock (Blasting prohibited ) 140 PVC Pannelling Providing and fixing of PVC Wall panelling of approved quality with frame work all complete as directed by Engineer-In-Charge. 141 PVC PannellingProviding and fixing of PVCpanelling of approved quality with frame work all complete in ceiling. 142 PVC Pannelling Providing and fixing of 12 mm thick (saphire 1223) PVC Wall panelling of approved quality with frame work all complete as directed by Engineer-In-Charge. 143 PVC Pannelling Providing and fixing of 19 mm thick ply board complete job. 144 Providing and fxing of PVC pipes with fittings all CompletePVC pipe of dia 100 mm 145 Providing and fxing of PVC pipes with fittings all Complete PVC pipe of dia 75 mm 146 Providing and fxing of PVC pipes with fittings all Complete Door Tee (0-4) 147 Providing and fxing of PVC pipes with fittings all Complete Door Tee (0-2-1/2) 148 Providing and fxing of PVC pipes with fittings all Complete Plain bend (0-4) 149 Providing and fxing of PVC pipes with fittings all Complete Plain bend(0-2-1/2) 150 Providing and fxing of PVC pipes with fittings all Complete Door bend (0-4) 151 Providing and fxing of PVC pipes with fittings all Complete Door bend(0-2-1/2) 152 Providing and fxing of PVC pipes with fittings all Complete Floor trap 153 Providing and fixing of composite pipe of CPVC all complete job. 15 mm dia 154 Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets 25 mm dia ( heavy type) 155 Providing and fixing of curtains of approved quality and good quality all fittings complete. (4 x 9) 156 Supply ofFreshner automatically controlled system. 157 Supply of Toilet Paper 158 Supply of Soap 159 Supply of Handwash 160 Supply of Wiper 161 Providing and fixing of window blinds of approved quality all fittings complete. 162 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete: 40 mm 163 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete: 50 mm 164 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete: 65 mm 165 Providing and fixing special quality bright finished brass cupboard or ward robe locks with four levers of approved quality including necessary screws etc. complete: 75 mm 166 Providing and fixing of Sun mica of good quality all fitting complete. 167 Providing and fixing of National Emblum of Brass make of good quality. 168 Providing and fixing of valvet cloth forchair/ sofas all complete. 169 Varnishing with flatting varnish of approved brand and manufacture one or more coats on old work. 170 Special Labour engaged for removing of unhygenic matrial from drains and culverts. 171 Providing, fixing and installation of Flex board (280 GSM) without frames duly primed and painted with two coats. 172 Providing and laying 60mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machine with strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. 173 Providing and laying 80mm thick factory made cement concrete interlocking paver block of M-30 grade made by block making machinewith strong vibratory compaction and of approved size and design/shape laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, filling the joints with coarse sand etc. all complete as per direction of Engineer-in-charge. 174 Supplying and fixing of Executive Chair, includingcarriages all complete job. 175 Supplying and fixing of OfficeChair,includingcarriages all complete job. 176 Supplying and fixing of Table( 2x4-0 ) including all leads and lifts and carriagescomplete job. 177 Supplying ofoffice Table (3-0x5-0) including all leads and lifts and carriagescomplete job. 178 Supplying and fixing ofoffice Table (5-0x6-0) including all leads and lifts and carriagescomplete job. 179 Providing and fixing of Curtains in different sizes of approved make including necessary fittings and approved by the engineer-in-charge complete Job. 180 Supplying and fixing of Double Bed of size(6-0x6-0) including all leads and lifts and carriagescomplete job. 181 Supplying of Double Blanket of approved. Brandincluding all leads and lifts and carriagescomplete job. 182 Supplying ofsingle Blanket of approved.. Brand including all leads and lifts and carriagescomplete job. 183 Supplying of Double Bed Sheet of approved.. Brand including all leads and lifts and carriagescomplete job. 184 Supplying of SingleBed Sheet of approved Brand including all leads and lifts and carriagescomplete job. 185 Supplying of doubleBed Quilt of approved Brand including all leads and lifts and carriagescomplete job. 186 Supplying of single Bed Quilt of approved Brand including all leads and lifts and carriagescomplete job. 187 Supplying of Mattress of size( 6-0x6-0x0-6 ) including all leads and lifts and carriagescomplete job. 188 Supplying of Mattress of size( 4-0x6-0x0-6 ) including all leads and lifts and carriagescomplete job. 189 Supplying and fixing of Carpet ofincluding fittingall leads and lifts and carriagescomplete job. 190 Supplying and fixing of kaleen carpetofincluding fittingall leads and lifts and carriages complete job. 191 Charges for shamyana Tentincluding fittingall leads and lifts and carriagescomplete job.Tent (Area to be measured only Carpet area) 192 Charges for shamyana Tentincluding fittingall leads and lifts and carriagescomplete job.Plastic Chair 193 Charges for shamyana Tentincluding fittingall leads and lifts and carriagescomplete job.Table 194 Charges for shamyana Tentincluding fittingall leads and lifts and carriagescomplete job.Fan 195 ELECTRIC WORK:Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc as required. (Group-A) 196 Wiring for light point/ fan point / exhaust fan point/ call bell point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, with modular switch, modular plate, suitable GI box earthing the point with 1.5 sq. mmFRLS PVC insulated copper conductor single core cable etc as required (Group-A) 197 Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel/PVC conduit including dismantling as required. (Group-A) 198 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc.as required. 199 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 amps & 15/16 amps. modular socket outlet and 15/16 amps modular switch connection etc. as required. 200 Supplying and fixing metal box of 150mm X 75mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 A socket outlet and 5/6 A piano type switch, connections, painting etc. as required. 201 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 A socket outlet and 15/16 A piano type switch, connections, painting etc. as required. 202 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 203 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 204 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 205 Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.2x1.5Sq.mm+ 1 x 1.5Sq.mm earth wire 206 Wiring for circuit/ sub-main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required2 x 2.5 sq mm + 1 x 2.5 sq. mm earth wire 207 2 x 4 sq. mm + 1 x 4 sq. mm earth wire 208 2 x 6 sq. mm + 1 x 6 sqmm earth wire 209 2 x 10 sq. mm + 1 x 6 sq. mm earth wire 210 2 x 16 sq. mm + 1 x 6 sq. mm earth wire 211 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 212 4 x 10 sq. mm + 2 x 6 sq. mm earth wire 213 4 x 16 sq. mm + 2 x 6 sq. mm earth wire 214 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 215 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1 x 1.5 sq. mm 216 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.2 x 1.5 sq. mm 217 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.3 x 1.5 sq. mm 218 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1x 2.5 sq. mm 219 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.2 x 2.5 sq. mm 220 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.3 x 2.5 sq. mm 221 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.1 x 4 sq. mm 222 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.2 x 4 sq. mm 223 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 3 x 4 sq. mm 224 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 4 x 4 sq. mm 225 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 5 x 4 sq. mm 226 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.6 x 4 sq. mm 227 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 6 sq. mm 228 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x 6 sq. mm 229 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 3 x 6 sq. mm 230 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 4 x 6 sq. mm 231 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 5 x 6 sq. mm 232 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 6 x 6 sq. mm 233 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 10 Sq mm 234 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x 10 Sq mm 235 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required.3 x 10 Sq mm 236 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 1 x 16 Sq mm 237 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 2 x 16 Sq mm 238 Supplying and drawing followingsizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC conduit as required. 3 x 16 Sq mm 239 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as 1 Pair 240 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as 2 Pair 241 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as 4 Pair 242 Supplying and fixing of ceiling fan offollowingsweep with 2.25 mfd condenser and 1-6 down rod on the existing fan hook with necessary connection from ceiling rose to fan using twin core copper wire. 900 mm sweep 243 BEE Star rated copper wounded double ball bearing capacitor start, aluminium body & Metallic blade ceiling fan Conforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge. 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 244 Supplying & fixing of Pedestal Fan 400 245 Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type)on wall with necessary connection as required. 246 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan.225 mm / 9 sweep exhaust fan 247 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan.300mm/12 sweep exhust fan 248 380mm/15 Heavy duty 249 Supplying and fixing of fan hook (U hook) on celiling with 2 nos. of anchor fastener on both ends with necessary bolts andnuts and mansonry work as required. 250 Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.6 way (Double door) 251 Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.8 way(Double door ) 252 Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.12 way (Double door) 253 Supplying & fixing of following way single pole and netural, sheet steel, MCB distribution board, 240 volts, on surface/ recess complete with tinned copper busbar netural busbar, earth bar, din bar, interconnections, powder painted including earthing etc. as required.16 way (Double door) 254 Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required.4 Way (4+12), (Double door ) 255 Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required.6 way ( 4+18), (Double door) 256 Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required.8 way (4+24), (Double door) 257 Supplying & fixing of following way horizontal type three pole and netural, sheet steel, MCB distribution board, 415 volts, on surface/ recess complete with tinned copper bus bar neutral buss bar, earth bar,din bar interconnection nection,powder painted including earthing etc. as required.12 way (4 +36), (Double door) 258 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make).20 mm 259 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make)25 mm 260 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make)32 mm 261 Supplying and fixing of following sizes of PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. (ISI Make)40 mm 262 Supplying and fixing of Following light fitting on ceiling/ wall with necessary connection from as required. Post Light 35 watts 263 IP20 SMD Mid Power LED batten type integrated light fixture made from Powder coated Extruded aluminium housing with in built driver , System lumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuitprotection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as per pre approved by Engineer in charge.20/22 watt LED 4 feetwith min. lumen output (2000- 2200) lm 264 Decorative LED Hanging Light for officer table as apporved by site Engineer 265 LED Batten Tube fitting 600mm size 10/11 watt 266 2x2 Recess Led Panel 595mmX595mm 36 W+/- 1W,Recess mountedfixture with HET PMMAdiffuser with minimum system lumen efficacy of 110 lm/W and minimum 3900 lumens withCRCA housingwith APFC constant Current driver for proper driving of LEDs and P.F.>0.95 with THD<10% ,CRI 80.The LED withlife of 50000 Hrs at L70. The LEDs used in the luminaire shall have CCT of 5700K- 6500K with CRI of minimum 80. The Input voltage range shall be 150V to 270V .The Fixture should have In-built Surge Protection of 3kV. Certification:- LM79 & LM80 test report should be from govt approved Inhouse NABL lab/ government of India authorised lab. 267 Mirror light LED fitting with 9/11W LED lamp 268 Providing and fixing of LED Lamp.5W 269 Providing and fixing of LED Lamp. 9W 270 Providing and fixing of LED Lamp. 12W 271 Providing and fixing of LED Lamp. 15W 272 Providing and fixing of LED Lamp. 18W 273 Providing and fixing of LED Lamp. 20W 274 Providing and fixing of E-27 LED Light9 watt (warm) 275 Providing and fixing of E-27 LED Light9 watt (White) 276 Providing and fixing of E-27 LED Light12 watt (warm) 277 Providing and fixing of E-27 LED Light12 watt (White) 278 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322omplianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures.LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in chargeLED Street Light fixture with Minimum lumen output 5600 lm 279 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322omplianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures.LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in chargeHigh Power LED Flood Light Minimum lumen output 8700 lm 280 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum material with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass cover and secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driver Efficiency >85% ,THD(I) <10% Humidity 10% to 90% RH Working Temp -5C to 45C . driver current <750mA. The luminaire shall be BIS certified and Trade mark certified. Life Expectancy Equal or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322omplianced.OEM Must have its own in house NABL lab setup for all testing facilities for LED fixtures.LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in chargeLED Street Light fixture with Minimum lumen output 11225 lm 281 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid PowerLED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as perapproved by Engineer in charge9 watt. 282 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid PowerLED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as perapproved by Engineer in charge15 watt. 283 Providing & Fixing of IP-20 LED Recessed / Surface Mounted, Round / Sqaure SMD Mid PowerLED Downlight with power coated die-cast aluminum housing with UV Stabilized non yellowish Diffuser with BIS complience 2.5 KV surge protected Isolated driver, with Short & Open circuit protection, having efficiency > 85% . System Lumen efficacy of ≥ 110 lm / watt, THD < 10 % , Pf.≥0.95, CRI >80, life time of minimum 50000 Burning Hours with , 70% of intial Lumen maintaned till life ends , CCT 3000°K / 4000°K/ 5700°K /6000°K/6500°K (As per ANSI Bin) , maximum power consumption should not more than the specified rating and Fixture shall be of BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80) certificate / Report from OEM shall be submitted. All as perapproved by Engineer in charge18 watt. 284 Providing & fixing of 5/6 Amp. 3 pinTop 285 Providing & fixing of 5/6 Amp 2 pin Top 286 Providing & fixing of 15/16 Amp 3 pin top 287 Providing & fixing of Insulation Tape (ISI brand) 288 Providing & fixing of Electronic Step Type fan Regular (Piano type) 289 Providing & fixing of Celing Rose 290 Providing & fixing of2.2/3/3.5 mfd fan condenser 291 Providing & fixing of Brass batten/ angle holder including (Modular) connection etc. as required. 292 Providing & fixing of Dimmer Type Regulator (with numbering) 293 Providing & fixing of 5/6 Amp combined 294 Providing & fixing of 15/16 Amp combined 295 Providing & fixing of Toolkit comprises of plier, screw driver and Phase tester 296 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mm x 75mm) 297 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.3 Module (100mm x 75mm) 298 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.4 Module (125mm x 75mm) 299 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.6 Module (200mm x 75mm) 300 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.8 Module (125mm x125mm) 301 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.12 Module ( 200mm x 150mm) 302 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 1 or 2 Module 303 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 3 Module 304 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 4 Module 305 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 6 Module 306 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 8 Module 307 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 12 Module 308 Supplying and fixing of5/6 amp switch 309 Supplying and fixing of 15/16 amp switch 310 Supplying and fixing of 3 pin 5/6 amp socket outlet 311 Supplying and fixing of 6 pin 15/16 amp socket outlet 312 Supplying and fixing of Telephone socket outlet 313 Supplying and fixing of TV Antenna socket outlet 314 Supplying and fixing of Bell push 315 Supplying and fixing of 2 pin socket outlet 5 Amp. 316 Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.5/6 amps switch 317 Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.2 way 5/6 amps switch 318 Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.15/16 amp switch 319 Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet 320 Suplying and fixing following modular switch/ socket on the existing modular plate & switch box inculding connection but excluding modular plate etc. as required.6 pin 15/16 socket outlet 321 Telephone socket outlet 322 TV Antenna socket outlet 323 Bell push 324 2 pin socket outlet 5 Amp. 325 Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge. 900mm /1200mm / 1400mm sweep AC ceiling fan 326 Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge. 300mm sweep exchaust fan 327 Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge. Servicing of the Geyser etc. as required. 328 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed) Heating Element 329 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed) Thermostat with control 330 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed) Replacement of Assembly complete job 331 Repairing of Geyser by ReplacingSingle pole upto 32 amp. 332 Repairing of Geyser by ReplacingSingle pole and neutral upto 32 amp. 333 Repairing of Geyser by ReplacingDouble pole upto 32 amp. 334 Repairing of Geyser by ReplacingDouble pole32 amp. (Modular) 335 Repairing of Geyser by ReplacingTriple Pole and netural upto 32 amp. 336 Repairing of Geyser by ReplacingSPN 40 Amp 337 Repairing of Geyser by ReplacingSPN 63 Amp 338 Repairing of Geyser by ReplacingTPN 40 Amp 339 Repairing of Geyser by ReplacingTPN 63 Amp 340 Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG. 341 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured.6 sq. mm 342 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured10 sq. mm 343 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured16 sq.mm 344 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured25 sq.mm 345 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured35 sq.mm 346 Labour charge for electrician 347 Labour charge for Helperelectrician 348 Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor. 349 Supply, Drawing and Testing of 4 pair, 23 AWG Solid Bare Copper wire insulated with PVC, UTP (Unshielded Twisted Pair), Category 6, Class E, 100 Ohm Impedance, Indoor Cable as per latest ammendments of ANSI/TIA/EIA-568 , The copper conductors should be balanced twisted in pairs, seperated by a cross-member fluted pair divider & protected by PVC Jacket. Certified performance in a 4-connector configuration upto 100 Mtrs channel requirements & transmission frequencies up to 250 Mhz. in existing MS/PVC Conduits/casing capping including making connections to Information outlets and Patch Panels with jack & ferruling at both ends for identification with necessary tools for punching, stripping, crimping and testing etc as required complete in all respect. All as pre approved by Engineer in charge. 350 Supplying ofRemote Bells 351 Supplying & fixing of following PVC Gang Box.One way 352 Supplying & fixing of following PVC Gang Box.Two way 353 Supplying & fixing of following PVC Gang Box. 1 + 1 way 354 Supplying & fixing of following PVC Gang Box. 3 + 1 way 355 Supplying & fixing of following PVC Gang Box. 4 + 1 way 356 Supplying & fixing of following PVC Gang Box. 6 + 1 way 357 Supplying & fixing of following PVC Gang Box. 1 + 1 way (Power) 358 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten).Casing Caping 1 359 CSupplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten). asing Caping 3/4 360 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten). Deep Box 361 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten). Fan Box 362 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten). Conceeled Box 363 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten). Junction Box (Metal) 364 Supplying and fixing ofPhenolic Laminated Sheet 9 x 11including cutting the space for switches/socket etc. 365 Supplying and fixing of Phenolic Laminated Sheet 9 x 6 including cutting the space for switches/socket etc. 366 Supplying and fixing of Phenolic Laminated Sheet 4 x 4 including cutting the space for switches/socket etc. 367 Supplying and fixing of Phenolic Laminated Sheet 11 x 13 including cutting the space for switches/socket etc. 368 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten).0.5 HP 369 Supplying & fixing of Electrical AccessoriesPVC Casing and Caping (Batten).1 HP 370 Rewinding of 1 phase (0.5 HP) motor for water lifting (Copper winding) 371 Rewinding of 1 phase (1 HP) motor for water lifting (Copper winding) 372 Supply & installation of following type inverters Invertor 1050 VA 373 Supply & installation of following type invertersInvertor2000 VA 374 Supplying & fixing of Battery 12 Volt. Tubular 150 AH with36 months Guarantee Note.:- (Rs.1800 /Battery has to be deduct for the scrap of old batteries from allotted rate in case of replacement of battery is out of warranty period. 375 Supplying of distilled water for Batteries 376 Supplying & fixing of PVC Trolley for housing single battery inverter 377 Supplying & fixing of PVC Trolley for housing double battery inverter 378 Repair to PCB of inverter 850 VAto 1050 VA 379 Repair to PCB of inverter 1650 VA to 2000 VA 380 Replacement of PCB of inverter 850 VAto 1050 VA 381 Replacement of PCB of inverter 1650 VA to 2000 VA 382 Supplying, installation, testing and commissioning of 1 KVA offlineUPS with minimum backup of 20 minutes and having over load, short circuit protection. 383 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. 5/6 Ltr (instant) 384 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. 15 Ltr 385 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. 25 Ltr 386 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. 35 Ltr 387 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required. 50 Ltr 388 Supply ofHalogen Electrical heaters (3 Rods) 389 Supply ofHeating Convector (Blower) 390 Supply ofPillar Heater 391 Supply ofRod for Pillar Heater Gopi 392 Supply ofElectric Fly Catcher 393 Supply of Electric Kettle above 1 Ltr. Upto 2 Ltr. Capacity. 394 Supply of Supplying of extension Card for bearing load upto 4 KW 395 Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required. (RO + UV + UF mineral control with TDS control ) 396 Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.UV purifier for water cooler 397 Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitACs (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall whereever required. Complete withwallstand outdoor etc. Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 398 Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitACs (copper) (3 star)Cold type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall whereever required. Complete withwallstand outdoor etc. Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 399 Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary. Warrantee.:-2 Years from the date of installation.4 KVA 400 Supplying, installation, testing and commissioning of 1.5 ton Window type ACs (copper) (3 star)Cold type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features. and repairs made to window whereever required. 401 Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC 402 Supplying & fixing of drain pipe for indoor unit 1 403 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC 404 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC 405 Supply, erection, testing and commissioning of compressor suitable for 1.5/2 Ton split /window type A.C with Gas charging and other required accessories to get A.C workable. 406 Provision of Gas charging of 1.5/2.0 Ton split/ window type A.C including valve etc if required. 407 Installationof 1.5/2.0 Ton window A.C 408 Installation of 1.5/2.0 Ton split A.C 409 Servicing of Split AC of All Capacities 410 Servicing of Window AC of All Capacities 411 Replacement of defective motor of 1.5 /2.0 Ton Split /Window A.C Outdoor 412 Replacement of defective capacitor for 1.5 /2.0 Ton Split /Window 413 Providing & fixing of Blades of 1.5/2.0 Ton Split / Window A.C 414 Providing & fixing of Blower drum (Split AC) 1.5 Ton Split A.C 415 Providing & fixing of Blower drum (Split AC)1.5 Ton Window A.C 416 Supply, erection, testing and commissioning compressor suitable for 150/150 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. 417 Supply, erection, testing and commissioning compressor suitable 40/80 ltrs. Water cooler with gas charging and other required accessories to get water cooler workable. 418 Provision of Gas charging of water cooler 150/150 ltr. 419 Provision of Gas charging of water cooler 40/80 ltr. 420 Dismantling of existing Split AC & reinstallation of Split AC with gas top up 421 Dismantling of existing Window AC & reinstallation of Window AC. 422 Dismantling of existing Split AC of All Capacities 423 Dismantling of existing Window AC of All Capacities 424 Repair ofPCB of Split/Window AC 1.5/2.0 Ton 425 Servicing of Water purifier by replacing candles. (R.O type) 426 Servicing of Water Purifierby replacing Candles of water cooler 427 Supplying, installation, testing and commissioning of 12 V 65 AH-SMF -VRLA batteries for UPS of 10 KVA. 428 Supplying, installation, testing and commissioning of 12 V 26 AH-SMF -VRLA batteries for UPS of 5 KVA. 429 Supply and Fixing of PVC Desert Air Cooler 50 ltr. with stand. 430 Supplying at site Angle iron post & strut of required size including bottomto be split and bent at right angle in opposite direction for 10 cm lengthand drilling holes upto 10 mm dia. etc. complete 431 Providing and fixing G.I. chain link fabric fencing of required width inmesh size 50x50 mm including strengthening with 2 mm dia wire or nuts,bolts and washers as required complete as per the direction of Engineer-incharge. 432 CARRIAGE OF MATERIALSBy Mechanical Transport including loading, unloading and stacking Sand for an Avg. distance of32 Kms by MT& 100M bt AT 433 CARRIAGE OF MATERIALSBy Mechanical Transport including loading, unloading and stacking Stone for an Avg. distance of 10 Kms by MT 150M AT. 434 CARRIAGE OF MATERIALSBy Mechanical Transport including loading, unloading and stacking Stonr Agr. for an Avg. distance of9 Kms by MT& 150M bt AT 435 CARRIAGE OF MATERIALSBy Mechanical Transport including loading, unloading and stacking Sand / Stone Agr. Fro an Averagr Distance of 10KM by MT &150M AT. 436 CARRIAGE OF MATERIALSBy Mechanical Transport including loading, unloading and stacking Brick for an Avg. distance of 200 Kms by MT 437 CARRIAGE OF MATERIALSBy Mechanical Transport including loading, unloading and stackingCarriage ofearthavg. lead of 01 km by MT

Key Value

Document Fees
INR 600 /-
EMD
INR 20000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail