Tender For Annual Plan-Purchase Of Equipments For Kanjoor Puthiyedam Palace Road Park-Installation Of 3D Sign Board, Light Posts And Wiring-General Electrical Work - Electrification OD543956/2024-2025:Design, fabricate, supply, install and test run, including transportation, LED 3D sign board of size 6X3 feet (Display text "SAKTHAN PARK" of 12 inch letter size), ACP Board with Acrylic 3D Letter with branded LED chip, Rain proof built in power Supply with 3 Year Warranty, including 2x8 feet GI poles erected in cementing plastered concrete footing of approx 12 cubic feet each. 90.15.4.3:Supply Conveyance, installation, testing and commissioning of 70W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD Less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 90.15.4.2:Supply Conveyance, installation, testing and commissioning of 36/40W LED street light output greater than 105lumen/W 4000-6000 K with IP 66 protection LED Chip make Cree/Lumilled/Nichea with power factor greater than 0.95 at full load, internal surge protection up to 8 KV,and Aluminium pressure die-cast Powder coated housing,acrylic cover complete with THD less than 10%, power factor greater than 0.98, RoHS compliant, duly wired up for use on 230 V AC supply. Driver compartment should be seperatly accessible for maintenance (LM 79&80 certificates from NABL accredited Third party lab to be produced mentioning chip manufacturer) 14.13.1:Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required50 mm dia OD542186/2024-2025:Supply and install by welding, 25 mm GI pipe to the existing 25 mm GI pole at 45 degrees angle, for mounting LED lights, and with holes for drawing electric cables from 50 mm pole, including painting., OD542095/2024-2025:Supply and install outdoor, weatherproof SMC junction box 200x140x95 mm, Sintax GSJB-2014 or equivalent on the base of existing lantern post. 90.12.1.1:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).2 core 4 sq mm 90.12.1.12:Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade of the following sizes in ground including excavation of trench of size 35 x 75 cm, refilling the trench etc. as required but excluding sand cushioning and protective covering (in ordinary soil).3 core 4 sq mm OD544336/2024-2025:Supply of 63/50 mm Double Walled Corrugated (DWC) pipes made out of HDPE for mechanical protection to underground power / communication / OFC/ Signal cables conforming to IS 1490 Part - II 9.1.1:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.2 X 6 sq. mm (19mm) 14.2:Excavation for cable trenches of depth upto 1.2 m in soft soil including getting out the excavated soil and disposal of surplus excavated soil as directed within a lead of 50 metres. 14.7:Providing and laying in position cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) in foundation of pump, DG set etc including form work etc as required. 14.12:Providing 15mm thick cement plaster of mix 1:4(1 cement: 4 fine sand) at all levels 5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. 90.16.5.5:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.4.75 mm (6 SWG) OD544465/2024-2025:Supply and providing 25x3 mm brass nut and bolt etc. as required. 5.2:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required OD542225/2024-2025:Supply and install weatherproof, outdoor, SMC meter box with MCB 430x215x150 Sintax GSMB 4422-1 or equivalent on the existing wall bracket near the KSEB post. OD543579/2024-2025:GI Support structure for mounting KSEB meter board and single/three phase distribution box, fabricated using 200 cm long GI pipe of dia 50 mm, buried 40 cm into ground in surface plastered RCC, 160 cm high over the ground, with rain guard canopy (made out of 3 mm MS Sheet) fixed to the top of GI pipe to protect the meter , 2x30 cm 25x25x4 mm GI angle welded to GI pipe for mounting meter/distribution box, including provision of 2 meter long, 40 mm medium 6Kg/sqcm PVC pipe for routing service wire and painting color washing etc. 2.3.1:Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator6 way, Double door 2.10.1:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 2.10.2:Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole and netural 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps OD544512/2024-2025:Supplying and fixing 63 amps amps rating, 240/415 volts, neutral link of two poles in the existing Meter box complete with connections, testing and commissioning etc. as required. OD544513/2024-2025:Supplying and fixing 63 amps amps rating, 240/415 volts, HRC fuse and fuse base suitable for inductive load of two poles in the existing Meter box complete with connections, testing and commissioning etc. as required.