}

Tender For Interior And Electrical Works In Btic, Ktiz, Kalamassery - Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Ste, kalamassery-Kerala

Technopark Campus has published Tender For Interior And Electrical Works In Btic, Ktiz, Kalamassery - Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Ste. Submission Date for this Tender is 02-08-2025. Interior Work Tenders in kalamassery Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

50226052
Tender For Interior And Electrical Works In Btic, Ktiz, Kalamassery - Steel Work In Built Up Tubular (Round, Square Or Rectangular Hollow Tubes Etc.) Trusses Etc., Including Cutting, Hoisting, Fixing In Position And Applying A Priming Coat Of Approved Ste
Tender
Indian
Kerala
Kalamassery
02-08-2025

Tender Documents

Tender Details

Tender For Interior And Electrical Works In Btic, Ktiz, Kalamassery - Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete 3 Gypsum Board Partition :Providing and fixing partition up to ceiling height (upto 360cm) consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with Zinc coating of 120 gms/ (both side inclusive), consisting of floor and ceiling channel 50 mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x0.5 mm), joint finisher and two coats of primer suitable for board as per manufactures specification and direction of engineer in charge all complete.75 mm overall thickness partition with 12.5 mm thick Moisture Resistant Board 4 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete 5 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work 6 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound) content less than 50 grams/ litre, of approved brand and manufacture including applying additional coats wherever required, to achieve even shade and colour. One coat 7 Demolishing brick work manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-Charge.In cement mortar 8 12 mm cement plaster finished with a floating coat of neat cement of mix:1:4 ( 1 cement : 4 fine sand) 9 Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer 10 Providing and fixing plain Multipurpose Cement board (High Pressure steam cured) as per IS : 14862, with suitable screws for fibre cement board inceiling etc. complete (frame work to be paid separately) :6 mm thick cement board 11 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two or more coats on new work 12 APPENDIX 2 - ELECTRICAL WORKSSPACE NEAR TO CORRIDOR ENTRANCE, GROUND FLOOR 13 Supply and Installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of 6 way(8+18 - double cover TPN vertical DB with provision for fixing FP MCCB as incomer and SP/TP MCB as outgoings (IP42/43) including copper/brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required conforms to IS 8623 - 1&3,IEC 61439-1&3. 14 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 15 Supply and fitting 63A, FP, 415V, 50Hz, RCCB, 100mA sensitivity conforming to relevant ISS 12640-1. 16 APPENDIX 2 - ELECTRICAL WORKSSPACE NEAR TO CORRIDOR ENTRANCE, GROUND FLOOR 17 Single Pole 18 16A (For 1 Tr Split AC) 19 20A (For 1.5Tr Split AC) 20 25A (For LDB) 21 6A ( For 6A socket ) 22 16A ( For 16A socket ) 23 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 24 6 way, Double door 25 Supply and fitting 16A, DP, 30mA, 240V, 50Hz, RCBO conforming to IEC 12640-2. 26 Supplying and fixing 5A to 32A rating, 240 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. 27 Single Pole,6A 28 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 29 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 30 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 31 3 x 1.5 sq.mm 32 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 33 20mm 34 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 35 1 or 2 Module (75mmX75mm) 36 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 37 4 Module (125mmX75mm) 38 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 39 8 Module (125mmX125mm) 40 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 41 5/6 amps switch 42 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 43 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 44 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. ( For Split AC ) 45 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 46 Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 47 100 mm width X 50 mm depth X 1.6 mm thickness 48 200 mm width X 50 mm depth X 1.6 mm thickness 49 Supply & installation of 20W LED linear suspended light fixture, housing made of Extruded aluminium, with 4000K colour temperature, and having minimum 100 lumen/Watt, suitable for indoor applications etc. as required. Make -Wipro or equivalent. 50 Supply and drawing No.10 SWG copper along wiring and earth lead With Superior Quality Copper Earth Socket Including Crimping . 51 Dismantling of existing installations and handover to the department. 52 SPACE NEAR TO WASH ROOM & KERALA NUTRACEUTICALS 53 Supply and Installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of 6 way(8+18 - double cover TPN vertical DB with provision for fixing FP MCCB as incomer and SP/TP MCB as outgoings (IP42/43) including copper/brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall, making good the damages, colour washing etc. as required conforms to IS 8623 - 1&3,IEC 61439-1&3. 54 Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps 55 Supply and fitting 63A, FP, 415V, 50Hz, RCCB, 100mA sensitivity conforming to relevant ISS 12640-1. 56 Supplying and fixing 5A to 32A rating, 240 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. (Remaining outgoings should be closed with dummy plates) 57 Single Pole 58 25A (For 2 Tr Split AC) 59 25A (For LDB) 60 6A ( For 6A socket ) 61 16A ( For 16A socket ) 62 32,TP.MCB (For 8.5Tr AC) 63 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 64 6 way, Double door 65 Supply and fitting 16A, DP, 30mA, 240V, 50Hz, RCBO conforming to IEC 12640-2. 66 Supplying and fixing 5A to 32A rating, 240 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc as required. 67 Single Pole,6A 68 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. 69 2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 70 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 71 3 x 1.5 sq.mm 72 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 73 20mm 74 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 75 1 or 2 Module (75mmX75mm) 76 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 77 10 Module (200mmX150mm) 78 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 79 8 Module (125mmX125mm) 80 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 81 5/6 amps switch 82 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings). 83 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. 84 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required. ( For Split AC ) 85 2 X 4 sq. mm + 1 X 4 sq. mm earth wire 86 Supplying and installing following size of perforated pre-painted M.S. cable trays reducers with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 87 100 mm width X 50 mm depth X 1.6 mm thickness 88 200 mm width X 50 mm depth X 1.6 mm thickness 89 Supply & installation of 20W LED linear suspended light fixture, housing made of Extruded aluminium, with 4000K colour temperature, and having minimum 100 lumen/Watt, suitable for indoor applications etc. as required. Make -Wipro Axeon or equivalent. 90 Supply & installation of 36W Max, Min system lumen output 2900 recess mounted 2x2 square down lighter LED with color temperature 5000-6500K. Make -Wipro or equivalent. 91 Supply and drawing No.10 SWG copper along wiring and earth lead With Superior Quality Copper Earth Socket Including Crimping . 92 Dismantling of existing installations and handover to the department.

Key Value

Document Fees
INR 2500 /-
EMD
INR 49400.0 /-
Tender Value
INR 19.73 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail