Tender For Repair/ Maintenance Of Internal Electrical Wiring Including Repairs Of Fans, Geysers At Md/Otm Accommodation At Asi, Aipt And Other Area Under Ge (Central) Pune.; 1 Taking down old unserviceable point wiring( light/fan/socket/power) complete, including fixtures and fittings such as switches, sockets, ceiling roses, pendants,regulators etc and making good the disturbed surfaces of walls, floors, ceiling etc.complete all as specified. 2 Taking downMain switches/DBs of any make and type including teakwood board, MCBs/MCCBs etc. complete and making good the disturbed surfaces including colour wash complete all as specified. 3 M&L for point wiring of any length using approved colour coding as per IS with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS H cable 1100 volts grade, ISI - 694 marked in and including PVC casing caping 25mm wide/PVC Surface conduits of appropriate size as per specification as requirerd at site and as directed of heavy duty ISI marked including all accessories etc. with PVC modular boxes/PVC Sunken Boxes as required at site and as directed including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified and directed for the following:-Note:- Making good of disturbed surfaces will be done by contractor without any extra claims. 4 One light point controlled by one, One-way switch complete all as specified and directed. 5 One Fanpoint controlled by one, One-way switch andregulator complete all as specified and directed. 6 One 3 pin 5 Amps Socket outlet point controlled by one switch on independent board complete all as specified 7 One 3 pin 5 Amps socket outlet point on same board complete all as specified. 8 One bell/buzer point controlled by one bell push complete all as specified. 9 Two light point controlled by one switch complete all as specified and directed 10 All as per item no. 03 above but with 2.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS H cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 Amps socket outlet point on independent board. 11 M&L for point wiring of any length using approved colour coding as per IS, with stranded copper conductor 1.5 Sq.mm (Nominal area), single core, PVC insulated and unsheathed stranded FRLS H cable 1100 volts grade, ISI - 694 marked, in and including PVC rigid conduits heavy duty ISI marked totally concealed in wall/floor/roof including all accessories etc. with Modular sunken boxes including modular frame/cover plate suitable for mounting switches/sockets etc. and PVC insulated stranded copper conductor 1.5 Sq.mm single core cable as earth and connecting to common earth dolly complete all as specified and directed for the following:-Note- (i) Cutting in chases and pointing in will be done by contractor without any extra cost to department. (ii) Making good of distrubed surfaces matching with existing finishes will be done by contractor without any extra cost to deparment. 12 One light point controlled by one, One-way switch complete all as specified and directed. 13 One Fanpoint controlled by one, One-way switch andregulator complete all as specified and directed. 14 One 5 pin 5 Amp Socket outlet point on same board with other switches including earth wire. 15 One 5 pin 5 Amp Socket outlet point controlled by one switches on independent board complete all as specified. 16 One bell/buzer point controlled by one bell push complete all as specified. 17 All as per item no. 05 above but with 2.5 Sq.mm(Nominal area), single core, PVC insulated and unsheathed stranded FRLS H cable 1100 volts grade, ISI - 694 marked, including PVC insulated stranded copper conductor 2.5 Sqmm single core cable as earth and connecting to common earth dolly complete all as specified for one 15 amps socket outlet point on independent board.Note:- Making good of disturbed surfaces will be done by contractor without any extra cost. 18 S & F modular switch 10A SP one - way 230V 1 module white/ ivory finish complete all as specified 19 S & F modular switch 10A SP Two - way 230V 1 module white/ ivory finish complete all as specified 20 S & F modular switch 16A SP one - way 230V white/ ivory 1 module ivory finish complete all as specified 21 S & F modular socket outlet 2/3pin 6 Amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified. 22 S & F modular socket outlet 2/3pin 16 Amps, multipurpose 2 module 230 Volts, single pole one way suitable for plug tops, complete all as specified. 23 S & F for Bell push, flush type, 5 Amp 1 module complete all as specified. 24 S&Fbell electrical ding dong including hard PVC board ISI marked complete all as specified 25 S & F240 V, Single pole and neutral enclosure with a two pin and earth plug and socket complete with one 20 Amp single pole MCBcomplete all as specified. 26 S&F ceiling rose surface type three terminalscomplete all as specified and directed. 27 S & F Modular type stepped electronic fan regulator2 module all as specified & directed 28 Supply and fixing in repairs of the following accessories :- 29 White cover plate with frame, 2 module complete all as specified. 30 White cover plate with frame, 3 module complete all as specified. 31 White cover plate with frame, 4 module complete all as specified. 32 White cover plate with frame, 6module complete all as specified. 33 White cover plate with frame, 8 modulehorizontal complete all as specified. 34 White cover plate with frame, 12 module complete all as specified. 35 Supply and fixing in repairs PVC Modular box of following sizes :- 36 White PVC Box of 2 module complete all as specified. 37 White PVC Box of 3 module complete all as specified. 38 White PVC Box of 4 module complete all as specified. 39 White PVC Box of 6module complete all as specified. 40 White PVC Box of 8 module complete all as specified. 41 White PVC Box of 12 module complete all as specified. 42 Supply and fix 3 core copper 1.5 sqmm twisted wire complete all as specified and directed 43 M & L for Sub main wiring with two single core 1.5 sqmm, 1100 volts grade, PVC insulated, strandedcopper conductor FRLS-H cable with one run of continuous copperearth conductor of 2.5 sqmmand including PVC casing caping of suitable size not less than 25mm dia including taking down old submain wiring complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any extra cost to department (ii) 3 runs of1.5 Sqmm conductor and one run of PVCcasing caping min 25mm dia shall be measured as one unit RM length.) 44 M & L for Sub main wiring with two single core 2.5 sqmm, 1100 volts grade, PVC insulated, strandedcopper conductor FRLS-H cable with one run of continuous copperearth conductor of 2.5 sqmmand including PVC casing caping of suitable size not less than 25mm dia including taking down old submain wiring complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any extra cost to department (ii) 3 runs of 2.5 Sqmm conductor and one run of PVCcasing caping min 25mm dia shall be measured as one unit RM length.) 45 M & L for Sub main wiring with two single core 4 sqmm, 1100 volts grade, PVC insulated, strandedcopper conductor FRLS-H cable with one run of continuous copperearth conductor of 4 sqmmand including PVC casing caping of suitable size not less than 25mm dia including taking down old submain wiring complete all as specified. (Note:- (i) Making good of disturbed surfaces will be done by contractor without any extra cost to department (ii) 3 runs of 4 Sqmm conductor and one run of PVCcasing caping min 25mm dia shall be measured as one unit RM length.) 46 M&L for Sub main wiring with 2 single core 6.00 sqmm 1100 volt grade, PVC insulated stranded copper conductor FRLS-H cable with one run of continuos coper earth conductor of 6 sqmm and including PVC casing capping of suitable sizedia including taking down and submain wiring complete all as specified. Note : (i)Making good disturb surface will be done by contractor without any extra cost.(ii)3 Run of 6 sqmm conductor and one run of PVC conduit shall be measured as one unit. 47 S&F LED light fitting surface and wall mounted LED batten with integrated electronic driver complete in all respect of 10W capicity including talking down old unserviceable fitting and making good the disturbed surfaces complete all as directed. 48 Supply and fix LED Tube light fittings 20W Surface and wall mounted LED batten, integrated electronic drivercomplete including all accessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable ofsuitable size from ceiling rose to connector. includingtaking down old unserviceable fittingsand making good the disturbed surfaces complete all as directed. 49 S & F LEDlight fittings 2x2 of capacity 36 watts environmental friendly, new genereation, aesthetically designed, ultra modern recess mounting luminaire with high brightness SMD LEDs as light source 230 volts with all accessories internally pre wired andnecessary mounting arrangements complete all as specified includingtaking down old unserviceable fittingsand making good the disturbed surfaces complete all as directed 50 Supply and fix lamp holder ( angle / bracket) insulated body with back plate for batten fittings including LED bulb of cap 8W 2 pin type complete for 230V 50Hz AC supply complete all as specified and directed by Engineer- in- charge. 51 S & F LED flood light 120 W flood light luminaire with ultra high sleek, light weight with secondary optics made ofpressure die-cast housings withtoughned glass and individual high power LEDs with secondary optics IP 66 rating alongwith connected accessories complete all as specified includingtaking down old unserviceable fittings etc and making good the disturbed surfaces complete all as directedNote: Necessary ladder arrangement shall be made by contractor to change the lights at heights in sheds. 52 S & F LED flood light 100 W flood light luminaire with ultra high sleek, light weight with secondary optics made ofpressure die-cast housings withtoughned glass and individual high power LEDs with secondary optics IP 66 rating alongwith connected accessories complete all as specified includingtaking down old unserviceable fittings etc and making good the disturbed surfaces complete all as directedNote: Necessary ladder arrangement shall be made by contractor to change the lights at heights in sheds. 53 S & F round recessed cum surfacemounted AL die - cast LED luminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation of 15W LEDdownlighterof white/neutral white 6500K colortemperature etc. prewired and all accessories complete all as specified and directed includingtaking down old unserviceable fittings etc and sheet cutting if any making good the disturbed surfaces complete all as directed 54 S&F LED security light ofluminaries 30 watt complete with all accessories andwall mounting bracket of suitable size including clamps, nut bolts etc. prewired including taking down old unserviceable fittings etc and making good the disturbed surfaces all as directed. 55 Supply & fix electronic driver suitable for 2x2 LED light fitting28/36 Watt system powerISI Markedincluding taking down old unserviceable driver. 56 Supply & fix electronic driver suitable for round LED light fitting15/18 Watt system power ISI Markedincluding taking down old unserviceable driver. 57 Supply & fix electronic driver suitable for LED light fitting 120 Watt system powerISI Marked including taking down old unserviceable driver. 58 S&F MCB TPN DB 4 way double door with rated current capacity rated busbar 415 V,all as specified. 59 S&F MCB SPN DB 8 way, double door, with rated current capacity rated busbar 240 V, all as specified. 60 S&F MCB SPN DB 4 way, double door,with rated current capacity rated busbar 240 V, SPN all as specified. 61 S&F vertical 4 way TPN DB double door, recess mounted/wall mounted, 3 pole V-Tec of rated current capacity & breaking capacity MCCB as incomer and outgoing MCB SP/SPN/TP, MCCBs is to be pre-fitted including taking down old MCB DB all as specified. (Note : (i)Empty space shall be covered by blanking plate and connecting with lugs withoutany extra cost to department (ii) Rate quoted by contractors shall be demed to be including of MCCB/ MCB/ SP/SPN/TPN of required braking capacity) 62 S & F in replacement MCCB 100Amps, 16KA, TP 415 Volts with adjustable thermal and fixed magnetic setting with including cable entry arrangements,lugs, glands etc and fixing arrangements such as fastener, nuts,bolts complete. 63 S & F in replacement MCB Single pole rated capacity 6 to 32 Amps, 240 V breaking capacity 10 KA ,C- curve complete all as specified. 64 S & F in replacement MCB double pole ofrated capacity 32 Amps, 240 volts breaking capacity 10 KA, C-curve complete all as specified. 65 S & F in replacement MCB four pole ofrated capacity 40/63 Amps, 415 volts breaking capacity 10 KA, C-curve complete all as specified. 66 S & F in replacement 1100 volts grade heavy duty cable PVC insulated copper conductor,three core cable flat or circular of size 6.0 sqmm all including PVC tags/Clips and fixing hardwares complete all as specified and directed. 67 M & L for earthing with galvanised steel earth plate electrode 60 cm x 60 cm x 6.0 mm buried directly in ground earth pit not less than 2.25 m deep below normal ground level, with top edge of the plate vertically to depth of not less than 1.5 m below ground level connected to and inclgalvanised iron wire 4mm as earthing lead and GI pipe 15 mm dia light grade for protection to the extent of 7.5 m as earthing lead by means of GI bolts and nuts etc connecting to equipment with provn of charcoal and salt etc all as per electrical plate No 3 of SSR Pt-I incl RCC cover , watering arrangement with GI pipe 20 mm dia and MS funnel, concrete pit with cover incl excavation and earth work in any type of soil and testing on completion etc complete. 68 Taking down ceiling fan of any size , sealing cable end, dismantling blades and removing fan and blades to storeyard of AGE E/M complete all as specified and directed. 69 Hanging only ceiling fan of any size afrer Refixing of fan blades, replacement of split pin and connecting up including provision of cable of suitable size from ceiling rose / connector to fan complete all as specified and directed. 70 Hanging / fixing only wall fan exhaust fan and connecting up including provision of 3 core copper cable white in colour from ceiling rose / connnector to fan including replacement ofsplit pin complete all as directed 71 M & Lfor cleaning, servicing and overhauling of ceiling / exhaust / wall mounting fan including lubricating , greasing and painting with one coat of synthetic enamel white paint and writing MES No on it complete all as directed of following sizes :- 72 Ceiling fans of 1200 mm size 73 Exhaust fan of 300 to 450 mm size 74 Wall mounting fan of 400 mm size 75 M & L rewinding ofceiling / exhaust / wall mounting fans complete with replacementof super enamelled copper wire of same guage and weight, replacement of insulation paper, varnishing, heating up and testing complete and depositingto AGEE/M store yard for re- fixing on site all as directed of following sizes :- Note : the quoted rate shall deemed to include transport if any. 76 Ceiling fan 1200 mm sweep working on 230 Volts AC supply 77 Exhaust fan upto 150mm/250/300/350/450mm sweep working on 230 Volts AC supply 78 Wall mounting fan of 400mm sweep, working on 230 Volts AC supply 79 Supply and fixing in replacement the following spare parts :- 80 Bearing 6201 Make : SKF 81 Bearing 6202 2Z . Make : SKF 82 Terminal connector 3 way Bakelite 83 Brass , gun metal bushing suitable for 1200/1400mm sweep ceiling fan. 84 Ceiling fan blade assembly 1200mm sweep 85 Wall /exhaust fan blade assembly 86 Supply and fix BLDC fan kit complete installation as per exisitng fan complete all as specified and directed 87 Supply Fix in replacement Capacitor 2.5 MFD 230 Voltscomplete all as specified and directed.Make : epcos 88 Supply Fixing in replacement Capacitor 4 MFD 230 Voltscomplete all as specified and directed. Make : epcos 89 Supply andFix in replacement canopy for ceiling fans (Set of two)complete all as specified. 90 Supply andFix in replacement MS clamp with rubber reel, nuts, bolts, split pin etc suitable for 1200/1400 mm sweep ceiling fancomplete all as specified. 91 S & F in replacement down rod made out of GI pipe medium grade 15mm bore dia with fan clamps including drilling , cutting threading etc all as directed for ceiling fan 1200/1400 sweep of following sizes:- 92 2 feet long 93 4 feet long 94 6 feet long 95 M & L servicing of geyser of 15/25/35 Ltrs capacity including cleaning, overhauling, spray painting with one coat of synthetic enamel paint and writing MES number and refixing the geyser to its original position completer all as directed. 96 Supply & fix in replacement thermostat ISI marked suitable for the Geysers 15 Ltrs to 35 Ltrs capacitycomplete all as specified. 97 Supply & fix in replacement fusible plug ISI marked suitable for 15 /25/35 ltrs capacity Geysers complete all as specified. 98 Supply & fix in replacement safety valve ISI marked suitable for15 /25/35 Ltrs capacity Geysers complete all as specified. 99 Supply & fix in replacement heating element for following rating as required at site (any type) including rubber washers (ISI marked) complete all as specified. 100 1.5 KW 101 2.0/3.0 KW 102 Supply & fix in replacement of storage inner tank made out of copper sheet suitable for following capacity geysers complete all as specified. 103 25 Ltrs capacity 104 35 Ltrs capacity 105 Supply and fix in replacement heavy duty Super high tensile stainless steel breaded hose pipe with brass ferrule fittingfor HOT and COLD water connections with minimum 30 inch legth fixed in same or new location as ordered / required at site as per manufacturers instruction with suitble size of nuts & bolts and hexagonal nipple if required and making necessary connection and testing on completion complete all as directed 106 Supply & fix in replacement steel braided with brass hexagonal adapters both side suitable for 15mm dia pipe 60cm long for cold water as per requirement complete all as specified. 107 Supply & fix in replacement PRV 15mm / 20mm dia of brass ISI marked complete all as specified. 108 Supply & fix in replacement temp indicators of Geysers 15 /25/35 Ltrs capacity complete all as specified. 109 Supply & fix in replacement gasket rubber ring for Heater plate of any size Geysers complete all as specified. 110 Supply & fix in replacement outer container 25/35 Ltrs made out of CRCA sheet duly painted complete all as specified. 111 Supply & Fix in replacemnet of Apparatus plate assembly of Geyser 15/25/35ltrs capacity all as specified and directed. 112 S&F in repair Switch piano flush type, 5 Amps, single pole, one way. 113 S&F in repairSwitch socket combination 2in 1, 5 A flush type. 114 S&F in repairSwitch socket combination 3 pin 5A/16A, 5 in 1, flush type 115 S&F in repair fan regulator 100W complete all as specified and directed