Tender For Repairs, Replacement & Maintenance works At Stp, Filtration Plant Under Ge Nrc.; 1 Excavation in trenches in soft / loose soil not exceeding 1.5 mtr deep and not exceeding 1.5 mtr wide for laying of cable, RCC poles / stays and struts etc. and getting out including trimming sides and forming bottom surface complete all as specified and directed at site. 2 Returning, filling in including spreading, leveling, watering and well ramming excavated soilin layers not exceeding 25 cm thick each, back in trenches after cables have been laid and tested, poles, stays, struts have been erected and tested , all as specified and directed. 3 Removing excavated surplus soil (Soft / hard soil) obtained from excavation to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point, complete all as specified and directed. 4 M&L for Area clearance/levelling/excavation /diggingat MES installation including STP ,removing shurbs grass,plant in drying bed 06 Nos Size 12.2 x 7.7 Mtrat any width and length by usingJCBcomplete all as directed by Engineer-in-Charge.Note 1. The cost of POL included in quoted rates .2. After Start and finsh of the work ,Hrs slips shall be provided by the contracator3. LOG Sheet shall be maintained. 5 S&F in replacementMild steel plates chequered, 5mm thick or over in thickness in available sizes or as directed by Engr-in-Charge including painting with Black oil paint over a coat of red oxide complete all as specified and directed 6 Dewatering by pumping out raw sewarage water with the help of diesel engine driven pump set or elecric driven pump set or by vaccume pump installed on vehicle from grit tank, aeration tank, primary settling, final settling, digestion chamber, Depot tank and ADGM tank and MAP STPdisposing the water through connected hose pipes etcfor removal of Sludge /Slitall as specified and directed . 7 M&L for Taking out sludge /silt removal of complete sludge and siltwith help ofmechanicallyoperated lift machine/crane,manually, scrapping out complete by vaccum pump installed on vehicle, sludge from the side wall of tank with the help of wire brush , taking out complete sludge and silt and depositing the same to a distance exc 1.00 Km and not exc 1.5 km at a site as directed and clearing the site as directed by Engr-in-Charge.Location :Grit tank, aeration tank, primary settling, final settling, digestion chamber, Depot tank and ADGM tank and Map STP Note:-(i) Contrcator is solely responsible for necessary safety and any mishapening during the subject work.(ii) Quoted rates inclues all T & P, pumps, lighting arrangement andsafety eqpts required. 8 M&L for scrapping of existing surface by use of steel brush of Main Gate STP and paintingwithtwo coats of sky blue paint synthetic enamelled paint complete all as directed . 9 Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 12/10 HP/7.5 HP (940/1540 RPM )for repair purpose including complete cleaning, varnishing , insulation replacement of DE /NDE bearings and greasing andincluding shifitng back to location and installing, testing and commissioning after repair complete all as specified and directed. (Note:-(i) T & Pand transportation to workshop & return is included in quotated rates(ii) Rewinding will be measure & paid seperately under relavant item of sch.) Notes for ser no 9 to 13:-(i) Being the essential Sewage treatment work,the Work shall be completed within -02 Days ashanded over by Dept ,else penelty of Rs.500 per day shall be imposed.(ii) If the work not be completed within 10 Days, the work shall be carried out at Risk and cost. 10 Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, 5 HP, 900 RPM capacity motors from respective non clogging centrifugal pumps/open well submersible pumps, other rotating mechanism etc, removing from foundations, dismantling rotor and stator, bearings, cleaning the dust/dirt, overhauling thoroughly including complete varnishing and reinsulation replacement of DE /NDE bearings ,greasing, reassembling the motor, mounting on the foundations, coupling with non clogging centrifugal pumps/respective mechanism, making the electrical connections, testing and commissioning all as directed.(Note:-(i) T & Pand transportation to workshop & return is included in quotated rates(ii) Rewinding will be measure & paid seperately under relavant item of sch.) 11 Disconnecting electrically and disengaging the AC Squirrel cage induction motor 3 phase 415 Vlots, 50 Cycles, and taking out to local workshop induction motor 0.5/1 HP 1440 RPM for repair purpose including complete cleaning,varnishing ,insulation replacement of DE /NDE bearings and greasing andincluding shifitng back to location as directed, installing, testing and commissioning after repair complete all as specified and directed. (Note- Rewinding will be measure & paid seperately under relavant item of sch.) 12 M&L for Rewinding the motor with super enamelled copper winding wire with appropriatesame gauge of exsisting coil with similar class of exsisting insulation as recommended by manufacturer with high quality normex insulating paperapplying best quality insulating varnish on stator/rotor windings drying them completely, testing the insulationsfor the Pump 12to 0.5 HP at Arty centre as directed by Engr -in - Charge( Note :- T & P & Transportation requried included in the Quotated Rate) 13 Dismantling the Chlorine PlantMake Declibac including Single Phase Pump motor upto 1 Hp capacity. Transporting to a workshop for repair, repair of the plant including spare parts which required & reflexing same on its original site after repair all as directed by Engr-in-charge. 14 M&L for cleaning/clearing of vegitation around theinstallations and disposing off as directed by Engineer-in-Charge. 15 Supply only GI Nuts & bolts with double washers of various sizes as dircted by Engr-in-Charge 16 Collecting samples of raw water and treated water from Sewage Treatment plant in 5 Ltr jerrycan and testing COD,BOD,TSS,TDS,PH tests in Govt authorised Lab or reputed laboratory and submitting test report to Engineer in charge.Note: 1. Four Jerrycans of 5 Ltr will be included in the schedule. 17 M&L for calobration of existing water flow meter located at Dharna Pumping Station through OEM/Auth agency.Note: Calibration certificate shall be submitted for the same 18 Repairs to intake operating gear system of settling tanks and filter beds and fixing required new rods, plate, nuts & bolts etc required greasing for smooth functioning all as specified and directed by the Engr-in-charge. 19 S&F in replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavyduty) with copper conductor,Earthed, grade cross sectional area 4 sq. mm 4 core 20 S&F DWC outer dia 40mm and inner dia 32 mm pipe of pressure ratingfor cable of 6Sqmm dia for cable protection complete all as directed 21 S&F in replacement of providing and fixing stainless steel (Grade 304) railing made of hollow tubes,channels,plates etc.,including welding,grainding,buffing,polishing and making curvature (where ever requried) and fitting the same with necessary stainless steel nuts and bolts complete,including fixing the railing with necessary acessories & stainless steel dash fasteners,stainless steel bolts etc. of requried size on the top of floor or the side of waist slab with suitable arrangement all as specified and directed. 22 M&L for in replacement Earthing complete with galvanized steel earth plate electrode 60 cm X 60 cm X 6.3 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of plate not less than 1.5 mtr below ground level connecting to the GI strip 32 x 6mm, by means nut bolt, nuts, check nuts and washer of the GI Earth wire protected by provision of GI light grade pipe 40 mm incl provision of concrete pit in PCC (1:2:4) type B-1 using 20 mm graded stone aggregated with 40 mm thick cover with RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg / Sqm) and frame of angle iron 25mm X 25 mm X 3mm with lugs 2 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edge of earth plate, common salt and charcoal filling, taste point made out of phosphorus bronze with fixing arrangement, funnel, wire mesh andearth work in hard/dense soil, returning filling in and removal of surplus soil to a distance not exceeding than 50 mtr, all as per electric plate No 3 of SSR Part I 2009 and connection to earth test point all as specified incl testing on completion”. 23 Supply only uPVC pipe 32mm dia rustproof and UV-resistant pipe of all as specified and directed. 24 All as per item No 23.00 above but40mm dia. 25 All as per item No 23.00 above but50mm dia. 26 Supply only uPVC Ball Valve 32mm dia rustproof and UV-resistant of all as specified and directed. 27 All as per item No 26.00 above but 40mm dia. 28 All as per item No 26.00 above but 50 mm dia. 29 Supply only Tee reducer uPVCofsize 3.2x3.2x1.5 cm all as specified and directed. 30 All as per item No 29.00 above but 3.2x3.2x2.0 cm 31 All as per item No 29.00 above but 3.2x3.2x2.5 cm 32 All as per item No 29.00 above but4.0x4.0x1.5 cm 33 Supply only uPVC female Adaptor brass threaded of 32mm dia all as specified and directed. 34 All as per item No 33.00 above but40mm dia. 35 All as per item No 33.00 above but50mm dia. 36 Supply only uPVC Union 20mm dia of all as specified and directed. 37 All as per item No 36.00 above but 25mm dia. 38 All as per item No 36.00 above but32mm dia. 39 Supply only uPVC Male Adaptor brass threaded32mm dia of all as specified and directed. 40 All as per item No 39.00 above but40mm dia. 41 All as per item No 39.00 above but50mm dia. 42 Supply only uPVC Reducing Male Adaptor brass threaded 20x12 mm of all as specified and directed. 43 All as per item No 42.00 above but25x20 mm. 44 Supply only uPVC Amended ball valve60mm of all as specified and directed. 45 Supply only uPVC clear medium solvent cement946 ml tin of all as specified and directed. 46 Supply only uPVC Elbow reducer 90° of size2.0 x 1.5 cm all as specified and directed. 47 All as per item No 46.00 above but 2.5 x 1.5 cm. 48 All as per item No 46.00 above but 2.5 x 2.0 cm 49 Supply only uPVC Elbow 45° of 6mm dia size all as specified and directed. 50 All as per item No 49.00 above but 40mm dia 51 All as per item No 49.00 above but 50mm dia. 52 Supply only uPVC Coupler of size 3mm dia all as specified and directed. 53 All as per item No 52.00 above but40mm dia. 54 All as per item No 52.00 above but50mm dia. 55 Supply only uPVC to CPVC Convertor of6mm dia all as specified and directed. 56 All as per item No 55.00 above but 40mm dia. 57 All as per item No 55.00 above but 50mm dia. 58 Supply only uPVC reducer coupler of 3.2 x 2.0 cm all as specified and directed. 59 All as per item No 58.00 above but3.2 x 2.5 cm 60 All as per item No 58.00 above but4.0 x 1.5 cm 61 All as per item No 58.00 above but 4.0 x 2.0 cm 62 All as per item No 58.00 above but 4.0 x 2.5 cm 63 All as per item No 58.00 above but4.0 x3.2 cm 64 All as per item No 58.00 above but5.0 x 1.5 cm 65 All as per item No 58.00 above but 5.0 x 2.0cm 66 Supply only uPVC Gate Valve 12mm dia with spindle type of all as specified and directed. 67 All as per item No 66.00 above but20mm dia. 68 All as per item No 66.00 above but25mm dia. 69 S&F of metal box MS Encloser made out of CRCA sheet 3.00 mm thick of size 500mmx500mmx300mm depth complete with three phase and neautral aluminium bus bar of capacity 200 Amps and fixing of 3P, 100A MCCB mounted on epoxy insulators, fixing arrangement with suitable MS Clamps of Size 32x6 mm thick all as specfied and directedcomplete all as specified and directed by Engr in Charge. Note: Rate for MCCB 100 Amp ,Aluminium Busbar 3 Pole and 1 Neautral of 200 Amp, Epoxy insulators and MS Clamps of Size 32x6 mm thick included in this item rate. 70 S&F in replacement Energy efficient LED Street/Roadway light ,IP 66 with efficeincy >110 LPW high PF, 45W, energy saving and enviromental friendly long life versatile pressure die cast aluminium housing, clear toughned glass, 240V,complete using 2.5 Sqmm, PVCinsulated (unsheathed) three core cable, 1100V grade with aluminium conductor from junction box to light fitting all as specified and directed. (For STP Location) 71 As per Item No. 70.00 abovebut60 W, with efficiancy >120 LPW. 72 As per Item No. 70.00 abovebut 90 W, with efficiancy >110 LPW. 73 S&F of Energy efficient LED Flood light Luminaire, high PF, 100W, efficeincy >110 /120 LPW, pressure die cast housing IP 66 protection,240V,completeusing 2.5 Sqmm, PVC insulated (Unsheathed) Two core armoured cable, 1100V grade with aluminium conductor (Upto 1.0 RM), complete including testing & commissioning. 74 As per Item No.73.00 abovebut 200 W, with efficiancy >110 LPW 75 S&F in replacement of LED 150 Watthaving Luminious output 150W,efficeincy >125LPW, operating temp-10 degree Cto 50 Degree C highbay optica heavy duty luminaires with engineering grade diffuser for added protection, secondary optics, suitable for industrial lighting applications, with IP 66 incl connecting up with three core flexible copper conductor cable of suitable size from ceiling rose Completed all as directed. 76 S&F in replacement of LED Gate light of capacity 35 watt for installations indirect light with IP 65 protection, resistant to impact and corrosion glare free and better uniformitycomplete all as specified and directed. 77 S&F in replacement of LED Bollard light of capacity 10 watt for installations indirect light with IP 65 protection, inverted Pyramid Tripod type LED bollard light with soft 360 degree light distribution complete including necessary foundation complete all as specified and directed. 78 S&F in replacement of LED Post toplight of capacity 20 watt indirect light with IP 65 protection,complete including necessary foundationcomplete all as specified and directed. 79 M&L for Dismantling of Existing Kerb Stone and S & F LED Kerb stone outdoor type IP 66, havingHigh qualityy plastic and fiber high capacity materialwith 1200 Kg load carrying capacity length 500mm ,width 150mm and height 120 mm ,in white,blueor as per requirement color ,LED light ,with PCB in metalcore ,lenghth of PCB 280mm width 25mm ,LED driver having variable voltage and constant current ,Input voltage90 V to 300 V ,AC -50 Hz and as per IS 16104 ,Operating voltage 220 Volts,THD below 10%,operating Temp-30 to 60 Degree,Driver having protection-Short circuit,Over load,Over Voltage and over Heat protection ,Surge Protection-up to 4 Kva complete all as directed. 80 M&L for PCC (1:3:6) type C-1 using 20mm graded stone agg as in coping on top of walland the like including weathering,slightly rounded or chamfered angles and throating as directed by Engr-in-Charge including use of necessary form work complete all as specified andas directed. 81 Dismantling of old steel pole / struts any type and size including demolition of concrete, foundation, necessary excavation and earth work and transportation etc. 82 Supply, fixing and install of 7 mtr height mild steel octagonal pole top 70 mm, bottom 130 mm, surface finished: hot dip galvanised, 3 mm thikness with base plate 200x200x12 mm and GI 64 micron, M19x600 EN 8 grade foundaction bolt and 1 mtr arm for light fittings complete including foundation drawing provided by OEM for foundation of pole. Note : Rate for RCC foundation as per drawing, Excavation, returning filling, 7 mtr pole, foundation bolts and nuts included in this item rate. 83 Supply and fixing in replacement of machine pressed precast interlocking paver block any size and shape of 80 mm thickness M-40 grade confirming to IS: 15658-2006 with grey cement and pigment and vibrated with mechanical vibrator, with 30mm thick crushed sand for cushioning all as directed. 84 Supply, fixing and laying in trenches or fixing or passing through pipe in replacement of 1100 Volts grade heavy duty LT UG cable, 2 core 6 Sqmm, with XLPE insulated stranded Aluminium conductor served with an inner sheathing of PVC tape, Armoured with galvanised steel wire and overall sheathedincluding cablegland, lugs, jointingmaterialetc,jointing, connecting ,testingandcommissioning allasspecified and directed. 85 All as per Ser item No. 84.00 here in before but 2 Core 10 Sqmm 86 M&L for Double Walled Corrugated DWC HDPE Pipe of outer dia 50mm and innter dia 38mmincluding 90 degree bends with coupler and rubber ringlaid in trenches of size 50 mm suitable for cable protection of size 2 core 10 sqmm to 3.5 core 50 sqmmcablecomplete all as specified and directed. 87 NOTE : - AMOUNT OF SCHEDULE OF CREDIT RS. 47850.00 WILL BE DEDUCTED FROM TOTAL AMOUNT OF BOQ.