Tender For Provision Of Tyre Bay Near Orp Complex And Puf Tank Of Capacity 1000 Ltrs For Certain Location At Af Stn Leh; 1 M&L for surface excavation not exceeding 30 cm deep and averaging 15cm deep and getting out complete in hard/dense soil complete all as specified and as directed.. 2 Excavating in post holes (or similar holes) in Hard/Dense soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm omplete all as specified and as directed. 3 Excavating in trenches n.exc 1.5 m wide and n exc 1.5 m in depth, for foundation, etc or for shafts, wells, cesspits, manholes, pier holes. Etc n exc 10 sqm on plan and n exc 1.5 m in depth and getting out in hard/dense type of soil, complete all as speified and directed. 4 Excavation over area not exceeding 1.5 mtr deep and getting out in hard/dense type of soil, complete all as speified and directed. 5 M&L for cement concrete Type D–2, 1:4:8 (40 mm graded crushed stone aggregate) as in foundations, filling and mass–concrete all as specified and directed. 6 M&L for cement concrete Type B–1, 1:2:4 (20 mm graded crushed stone aggregate) as in foundations, filling and mass–concrete all as specified and directed. 7 M & L for cement concrete 1:2:4using 20mm graded stone aggregate as inlintels upto 1.5m clear span, cills, steps, seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs , water troughs and the like includingformwork ,weathering, slightly rounded or chamfered angles and throating complete all as specified and as directed by Engineer-in-Charge. 8 Providing precast cement concrete 1:2:4typeB1 in window or door cills,lintels, bressumers,steps, quoin blocks (for use with masonry), string courses, copings. kneelers, apex stones, pier caps, columns, posts, boundary pillars, bed plates, pintle blocks,ancho-rage blocks, bonders (for stone wallin). corbels, brackets, etc. (of any section indicated), with plain fair faces, includingchamfers, weatherings, throat- ing etc. and setting in mortar complete with joints to match all as specified and directed. 9 M&L for Pre–cast cement concrete block masonry with solid blocks of Type C–1, 1:3:6 (20 mm graded crushed stone aggregate) exc. 10 cm in width and setting in mortar 1:4, complete all as specified and directed. 10 Returning, filling Including spreading, levelling, watering and well ramming in layers not exc 25 cm in hard/dense soil complete all as speified and directed by Engineer-in Charge 11 Removing excavated material (soil) exc 1.50 km and n exc 5.00 km from the starting point, complete all as speified and directed by Engineer-in Charge 12 M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finish smooth & even without using extra cement complete all as speified and directed by Engineer-in Charge 13 M&L for Hardcore of broken stone or boulders gauge n exc. 63 mm, deposited, spead and levelled in layers n exc 15 cm thick, watered and rammed to true surface complete all as specified and directed by Engr-in-charge. 14 M&L for sand filling under floor or in cushion under interlocking tiles etc complete all as specified and as directed by Engr-in-Charge 15 M&L 100mm thick cement concrete 1:4:8, type D-2, (using 40 mm graded crushed stone aggregate) as in sub base complete all as specified and directed. 16 M&L 70 mm thick cement concrete 1:2:4, type B-1, (using 20 mm graded crushed stone aggregate) as in sub base complete all as specified and directed. 17 M&L 40 mm thick cement concrete type B–0,1:2:4,(using 12.5 mm graded crushed stone aggregate) as in Sub-Floors, sub bases, Floors complete all as specified and directed. 18 M&L machine cut kota stone slab flooring 20-25mm thick over 20 mm thick cement screed base in CM 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete complete all as specified and directed by Engr-in-charge. 19 S&F for steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed. 20 S&F for rolled mild steel sections as in column main and joist, channel, angle, or tee sections, fixed independently etc. (cut to ordinary lengths i.e. within 20mm of the length indicated, fixed with angle cleats or other connecting plates of Fe 410-W (Gde E-250) quality A complete all as specified and directed by Engr-in-Charge. 21 S&F Plates (plain or chequered) channels,squarecutor notched (ordinaryand counter sunk) confirming to Fe 410-W(GdeE-250),forming holes, with riveted, bolted or welded attachment, complete all as specified and as directed by engineer in charge 22 S&F Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut,, n exc 5cmlong where diameter of neck is 5 to 10mm as required 23 S&F 60mm thick PUF panels in wall with 0.5mm prepainted galvalume sheet on both face/side including all fixing arrangements complete all as specified and as directed by Engr–in–Charge. 24 S&F 40mm thick PUF false ceiling panels with 0.5mm prepainted galvalume sheet on both face/side including all fixing arrangements complete all as specified and as directed by Engr–in–Charge. 25 M&L for door shutters with 60mm thick PUF panel with 0.5mm thick prepainted MS sheet on both side (Colour as approved by GE) including aluminium 200mm tower bolt (2 Nos), aluminium sliding bolt 300mm (01 Nos) and handle 02 nos on both faces including chowkhat of angle 60 x 60 x 6mm fixed with 03 Nos (100mm) heavy duty hinges complete all as specified and directed by Engr-in-Charge. 26 S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. 27 S&F Pre- painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws, complete all as specified and as directed. 28 S&F for anodised aluminium frame for doors, windows, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified complete all as specified and directed. 29 S&F anodised aluminium window and ventilator shutters, side hung type without sash bars, aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings such as peg stays 150mm long (1 no.). hinges type B-21 100mm long (2 no.) suitable handle (1 no.) complete all as specified 30 S&F anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill toproper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineerin- charge. 31 S&F for sheet glass 4.8 mm thick oridinary quality and glazing with rubber packing to sliding windows in square not exceeding 0.50 sqm in each pane complete all as specified and directed. 32 S&F for Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framedbalusters; walk ways; railings; framework of water tanksand similar work conforming to Fe.290.Gde-E-165 complete all as directed. 33 S&F 9 mm veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces fixed with screws to Iron frame work complete all as specified and directed. 34 S&F 18 mm veneered decorative plywood, grade 1 (with BWR resin) with decorative face veneers on both faces fixed with screws to Iron frame work complete all as specified and directed. 35 M&L for preparation of new steel surfaces of any description over 10 cm width or girth, not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as directed. 36 S&F for aluminium (die cast body) door closer hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed. 37 S&F for 12mm thick rubber mat for flooring fixing with epoxy resins solutions complete all as specified and directed by Engineer in charge. 38 M&L for 75mm thick PCC 1:3:6Type C2 (using 40mm graded stone aggregate) as in plinth protection and Paving including finishing even and smooth without using extra cement complete all as specified ans as directed. 39 M&L preparation of new surface of wall and applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces as in camouflaging pattern ,complete all as specified and as directed by Engineer-in-Charge.Note : Camouflaging pattern will be approved by the GE. 40 M&L preparation of new steel painted surfaces of any description of Walls/Roofs exceeding 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer as in camouflaging pattern , complete all as specified and directed by Engineer-in-Charge. Notes:(i) Camouflaging pattern will be approved by the GE.(ii) Workshall be executed Upto 10 mtr high .(iii) All Safety measures for the safety of workmen shall be ensured by the contractor. Insurance of workers shall also be got done by the contractor before execution of work. This aspect shall also deemed to be included in the quoted rates and nothing extra shall be admissible on this account. 41 S&F Machine pressed precast cement concrete coloured interlocking paver block of any shape and size confirming to IS-15658-2006 of 60mm thick with gray cement and pigment (M-35 Grade) complete all as specified and as directed by Engr-in-charge. 42 Supply, installaing, testing and commissioning of energy efficient 5 star rated as per BEE air cooled, split unit air conditioner, all weather with heating cooling, electric driven, with cordless remote control unit, single phase of capacity 1.5 ton, including cutting holes for connection between indoor and out door unit with copper tubing, stand etc, and testing for leakage, suitable for CFC/HCFC refrigerent completeall as specified and directde at site. 43 Supply, installing, testing and commissioning of Voltage stabiliser copper wound for automatic operation, single phase, 50 c/s AC Supply naturally air cooled indoor type, wall mounted & designed for input variation between 170 V to 250 V with out put voltage stabilised at 230 V with accuracy of + 2.5% and capacity 5 KVA, complete all as specified and directed by Engr-in-Charge. 44 M&L for submain wiring with two single core 06 Sqmm (nominal area) PVC insulated copper conductor FRLS, multi-stranded, unsheathed 1100 volts grade in PVC casing cape including 06 Sqmm copper conductor cable FRLS as earth wire, complete all as specified. Note :- 3 Run of 06 Sqmm copper conductor cable & 01 Run of PVC casing caping with necessary accessories shall be measured as one unit. 45 Single Pole and Neutral enclosure with two pin and earth plug socket complete with one single pole MCB 20 Amp, complete all as specified and directed. 46 M&L for point wiring in steel conduit unsheathed multistrand copper conductor cable of 1.5 sqmm single core FRLS for one light / fan point controlled by one flame proof switch including continious copper earth wire of same size connected to common earth dolly complete all as specifed and directed. Note (a) wiring shall be done by using copper coding. 47 All as per item No 1 here -in - above but using 2.5 Sqmm wire for 15 Amp flame proof socket, complete all as specified and directed by Engr-in- charge. 48 S&F LED flameproof light fitting 1x20 Watts, CIMFR approved and recommended for gas/ vapor gropu of IIA & IIB, zone 1&2and IP65 protection with die cast aluminium housing with heat resistant toughend glass with LED tube light fixtures, driver, holder, connector etc, complete with all accessories pre wired and including connecting up with three core flexible copper conductor wire of suitable size complete all as specified and directed by Engr-in-charge. 49 S&F switch flame proof rotary type with termination box in LM6, 16 Amp, single pole 250 volts. Make: Sudhir Switchgear or equivalent 50 S&F flame proof switch socket & plug combination in LM6 cable termination box in LM6, 16 Amps 250 volts 2P+ earth, complete all as specified and direceted. Make: Sudhir Switchgear or equivalent 51 S&F flame proof SPN DB 4 way 240 V having 200 A rated bus bar with 32 Amps SPN MCB-01 No and16-32 Amp SP MCBs 02 Nos, complete all as specified and directed by Engr-in- charge. Make: Sudhir Switchgear or equivalent 52 S&F air compressor for multipurpose use with tank capacity270 ltr 10 bar max pressure and displacement 220 ltr/Min, with 3 HP 2800 RPM copper wound single phase motor. The compressor shall be designed to be oil free usage. The compressor shall be provoded with heavy duty pressure pipe of length 25 Mtr. Make:- Ingersoll Rand, ELGI, Paras 53 M&L for earthing as per IS:3043with galvanized steel earth plate electrode 600 x 600 x 6.0 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to galvanized iron wire 4 mm dia (8 SWG) as earthing lead protected by GI pipe medium grade 15 mm bore for protection of GI earth wire and 20 mm dia GI pipe medium grade for watering with alternate layers of charcoal /coke and salt including all accessories like nut, bolts, reducer, nipple, wire meshed/screened funneland making brick masonry finished chamber of internal size 300 mm x 300 mm x 300 mm with concrete base, covered with PCC cover which shall be embedded in the block masonryincluding excavation works, refilling, connected to main switch/MCB DB for feeding the electric supply to domestic quarters compete all as specified as shown in electricall plateNo. 3 of SSR Part-I and testing of earth resistance as required. Note : Earthing lead/G.I.Earth wire upto 7.5 metre length shall be deemed to be included in quoted unit rate beyond 7.5 metre, the same shall be measured and paid separately). 54 S&F storage tank of capacity 1000 Ltrs made of high density virgin polyethylene ( Non reacting material), perfect blend of high and low density vigine polymer with 50 mm machine compressed PUF insulation in middle, in three layers, with suitable locking arrangement including provision of inlet and outlet connection complete all as specifed and directed. 55 S&F storage tank of capacity 500 Ltrs made of high density virgin polyethylene ( Non reacting material), perfect blend of high and low density vigine polymer with 50 mm machine compressed PUF insulation in middle, in three layers, with suitable locking arrangement including provision of inlet and outlet connection complete all as specifed and directed.