Tender For Addn/Altn To Bldg No P-117 Md Accommodation Of 501 Asc Bn In New Kse At Patiala Mil Station., patiala-Punjab

Military Engineer Services has published Tender For Addn/Altn To Bldg No P-117 Md Accommodation Of 501 Asc Bn In New Kse At Patiala Mil Station.. Submission Date for this Tender is 12-08-2025. Paver Blocking Tenders in patiala Punjab. Bidders can get complete Tender details and download the document.




Tender Notice

50220836
Tender For Addn/Altn To Bldg No P-117 Md Accommodation Of 501 Asc Bn In New Kse At Patiala Mil Station.
Tender
Indian
Punjab
Patiala
12-08-2025

Tender Documents

Tender Details

Tender For Addn/Altn To Bldg No P-117 Md Accommodation Of 501 Asc Bn In New Kse At Patiala Mil Station.; 1 Dismantling of brick tiles or terracing tiles single layers on roofs complete all as specified and directed by Engineer-in-Charge 2 Demolition of mud in roofs, any thickness, including plastering and leeping(whether full thickness removed or only a part thereof) complete all as specified and directed by Engineer-in-Charge. 3 Material & labour for Roughening surfaces of old concrete floor/roof by picking, sweeping clean and washing down with water to remove dust, etc. complete all as specified and directed by Engineer-in-Charge. 4 Material & labour PCC 1:3:6, type C-0 using 12.5mm graded stone aggregates as in padding over roof, minimum thickness at khurra as 45mm to maintain slope of 1:100, complete all as specified by Engineer-in-Charge 5 Cutting grooves in brick wall, 75mm wide and 65mm deep and shaping horizontal face of groove with cement mortar 1:3 complete all as specified by Engineer-in-charge 6 Providing and laying 3mm thick APP (Atactic Polypropylene Polymer) modified prefabricated five layer, weight not less than 4.0 Kg/Sqm water proofing membrane black finished, reinforced with non-woven polyster matt make as approved including of a coat of bitumen primer 0.40 Itr/sq m by the same membrane manufacturer of density 0.87 to 0.89 Kg/Ltr at 25 degree C temperature and viscosity 70-160 cps Over the coat, the layered APP membrane shall be laid using butane torch and sealing all joints etc after the surface complete as per standard practice as per manufacturers instructions. The laying of membrane shall be got done as per the instructions of manufacturer, all as and directed by Engineer-in-charge. 7 Material & labour factory madePrecast PCC plain factory made tiles,22 mm thick, of size 250 mm x 250 mm, machine pressed and cut polished and set jointed and pointed in neat cement slurry andfabricated using grey cement & no pigments. over and including 15 mm thick cement mortar (1:6) bedding and joints grouted flush in cement mortar (1:3) mixed with integral liquid water proofing compound over roof surfaces complete all as specified and directed by Engineer-in-Charge. 8 Material and labour for PCC 1:3:6, type C-1 using 20mm graded stone aggregates as in edge, chamfered and coping etc, complete all as specified and directed by Engineer-in-Charge 9 Supply & fixing for PVC(HDPE) rain water pipes, 150 mm bore, single socketed in any length with rubber ring joints fixed to walls complete all as specified including fixing of pipe to wall with flat iron clamps of size 25 x 3mm, bolts washing, nuts etc includingtaking down existing damaged CI rain water pipe complete all as specified and as directed 10 Supply & fixing PVC (SWR) bends/tees of any radius for 150mm bore as in repair complete all as specified. 11 Dismantling, floor, hearth or wall tiling including CM(bedding (but not backing), removing serviceable tiles to store & rubbish off the premises 12 Material & labour for Non - skid coloured Ceramic tiles 10mm thick (square/ rectangular) area of Each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cementslurry over and incl 15 mm thick cement mortar (1:6) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-Charge. 13 Material & labour for Glazed ceramic coloured printed/digitaltiles area of Each tile 8mm thick exceeding 0.11 sqm but not exceeding 0.18 sqm,onvertical surface such as skirting , dado etc. over and including 10 mm thick rendering in cement mortar 1:4 thick set and jointed in neat cement slurry and pointed in white or colour cement to match the tiles complete all as specified and directed by Engineer-in-Charge. 14 Material & labour for non skid Ceramic tiles(light shade) 10 mm thick (square/ rectangular) polished, size of each 600mm X 600mm, 10mm thick in floors etc. set and jointed inneat cement slurry and pointed in white or coloured cement to match, joined in cement slurry over and incl 15mm thick cement mortar (1:6) screed bed and pointed in white or coloured cement to match the tiles complete all as specified and directed by Engineer-in-charge. 15 Demolition ofStone slabs and tiles of any description or thickness in floors, aprons etc. complete all as specified and directed by Engineer-in-charge. 16 Material & labour for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations with pigment to match the shade of slab including rubbing, cutting and mirror type granite polishing complete all as specified and directed by Engineer in charge. 17 M&L for Baroda Green marble,machine cut as in shelves/steps/cills/jambs/skirting/border only in tile flooring and the like works and flooring etc,20mm thick including bull nose the front length,set and jointed in cement slurry over & including screed of 15mm thick rendering in cement mortar (1:4) and pointed in cement mixed with pigment to match the shade of slab including rubbing,cutting and mirror type granite polishing complete all as specified and directed by Engineer in charge.Note: Single piece should be used in steps/cills/jambs/shelves. 18 M & L for 18- 20mm thick granite (of any type) work (table rubbed and polished) in steps, Jambs, pillars, window cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite and including 20 mm thick cement plaster (1:3) complete all as specified and directed by Engineer in charge. 19 Demolition of cement concreteun -reinforced in ground floors and pavings complete all as specified and directed. 20 Material and labour for Plain cement concrete 1:7:12 mix,(using 40mm graded Brick aggregate) as in filling of sunken portion complete all as specified and directed. 21 Material and labour for carrying out water proofing treatment of sunken floor complete all as specified as under:(i) The concrete/wall surface shall be cleared thoroughly of all laitance,loose particles,dust,grease etc and any friable and unsound area which shall be chipped,cleaned and thereafter pre-wetted to a satured surface dried condition. (ii) In case of pot holes/superficial cracks,the same shall be repaired with polymer modified mortar using URP as admixture @ 10% of cement content. (iii) The polymer modified mortarusing URP as admixture @10% of cement content shall also be applied on vertical surfaces after removing of plaster upto 60 cm height.(iv) The surface thus prepared shall be coated by applying 2 coats of Dr Fixit Hydrochem super in the sunken areas and extending it upto 150 mm above the finished floor level.This includes layer of a 150 mm wide strip of an open woven glass fiber mesh over the PCC benching (Gole) on the 1st coat whille it is still wet.(v) Rendering 15 mm in CM 1:4 admixed with integral water proofing compound 1 W+ @ 200 ml per bagof cement complete all as specified and directed by the Engineer-in-Charge. 22 Providing 50 mm dia GI pipe light grade spoutscomplete all as specified and directed. 23 Material & labour for PCC with type B-0. 1:2:4 (20mm graded aggregate) 40 mm thick as inflooring and finishing the floor even and smooth without using extra cement complete all as specified and directed by Engineer in charge. 24 Supply & fixed in repair vitreous china premium/1st quality wash basin white/ivory/off white, flat back, size 550x400 mm including pedestal, screws & plug and brackets etc. all accessories as recommended by manufacturer incl inlet and outlet screwed for pipe or connections incl all necessary accessories for fixing, packing, union andincl 32mm brass CP waste coupling and waste pipe complete in all respect as per manufacturers instructions complete all as specified and directed by Engineer in charge. 25 Supply & fixing vitreous china premium/1st quality wash down water closet pan floor mounting (pedestal pattern/EWC) S/P trap white/ivory including connection to drain (or out going pipe) and to flushing pipe, antisyphonagee pipe,etc.,with flush pipe CP 32mm dia and incl. plastic seat cover as recommended by manufacturer closed pattern with flat bottom etc; and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and including supply and fix of PVC long arm S/P trap so that joint is avoided inside the building as well as in wall and outlet straight away come out of wall in all floors except G.F complete all as specified and directed by Engineer in charge. 26 Supply and fixed in repair Health faucet (ABS Body) mild steel chromium plated suitable for 15 mm dia pipe with 1.25 metre long flexible CP tube and ABS wall hook including making connections and fixed in position complete in all respect as specified. 27 Supply & fixing flushing cistern of PVC 10 ltr. cap. with dual flushing system, valveless syphonic action type, , low level, white/ivory/off white with inlet, ball valve, float and including brackets and connection to pipe etc. and incl all necessary accessories like rag bolts/gel gasket etc as recommended by manufacturer for fixing, packing and taking down existing of any description/size complete in all respect all as specified. 28 Supply and fixed in repairof Cast iron spun pipes 100mm bore pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. 29 Supply and fixed in repairof Cast iron soil, waste and vent pipe, 100mm bore, spun castin any length, with or without ears, with cementjoints, fixed to walls with and including stack clamps (25x3 mm), nuts , bolts etc. and making necessary connectionscomplete all as specified. 30 Supply and fixed in repairof Cast iron spun pipes75mm bore pipe, soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors complete all as specified and directed. 31 Supply and fixed in repairof Cast iron soil, waste and vent pipe,75mm bore, spun castin any length, with or without ears, with cementjoints, fixed to walls with and including stack clamps(25x3mm), nuts , bolts etc. and making necessary connectionscomplete all as specified. 32 Supply & fixing for cast iron branch pieces single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 100 mm bore pipe, fitted with oval access doorjointed with cement joint, complete all as specified. 33 Supply & fixing for cast iron branch pieces single(equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches, suitable for 75 mm bore pipe, fitted with oval access doorjointed with cement joint, complete all as specified. 34 Supply & fixing for CI Cowl suitable for 100 mm bore pipe as in repair, complete all as specified. 35 Supply & fixing for Cast iron bends/Tee duck foot or heel rest, radiusfor 75 mm bore pipe, complete all as specified and directed. 36 Supply & fixing for Cast iron bends/Tee duck foot or heel rest, radiusfor 100 mm bore pipe, complete all as specified and directed. 37 Supply & fixing Salt-glazed stoneware gully traps, 150x150mm size,square or round mouthed, type P or S incl CI grating fixed in repair complete all as directed and specified. 38 Supply & fixing Cast iron floor trap 100mm dia and 600mm long including jointing with solvent cement in repair complete all as specified and directed by Engineer-in-Charge. 39 Supply & fixing doubled layered rotational moulded polyethylene white water storage tanks (cylindrical vertical with closed top / cover) 1000 Ltrs capacity hoisted and fixed in position all as specified including ball brass valves, high pressure, with polythene float and fly nut complete screwed for 20mm bore iron pipe and including GI nipple/union of 20mm bore to connect GI tubing to PVC tank complete all as specified and directed. 40 Taking up or down 15 mm steel tubing and connections, including cleaning for refixing or removal to store. 41 Taking up or down 20 mm steel tubing and connections, including cleaning for refixingor removal to store. 42 Supply and fixing 15mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified. 43 Supply and fixing 20mm bore steel water tubing medium grade galvanised with all fittings and fixed complete to walls and celing or laid in floor etc complete all as specified. 44 Supply and fixing 20mm bore Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. 45 Supply & fixed in repair Bib taps,CP,fency type long body with wall flange screwed for 15mm bore of iron pipe or for brass ferrule and fixed in position complete in all respect all as specified. 46 Supply & fixed in repair 15 mm dia Stop cock cast copper alloy fancy type CP with long shank and cup (concealed type), screw down high pressure, screwed both ends for iron pipe or for union and fixedcomplete all as specified and directed 47 Supply & fixing 600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washerscomplete all as specified and directed 48 Supply & fixed in repair Tubular towel rail, 20mm dia, D type, 60cm long between flanges complete all as specified and directed 49 Supply & fixed in repair stainless steel sink with drainage board,1.00 mm thick, glossy finish, for kitchen with plugs washers and waste couplingof 32mm diaand including cantilever cast iron brackets, connecting union, etc, overall size 915mm x460/928mmx458mm with bowl size 410x 355x185mm/430x355x200 with wall connection pipe & wall flange and making good disturbed portion in CM 1:3 or PCC 1:2:4 complete all as specified and directed. 50 Supply & fixed in repair wall mounted mixer with swinging spout and with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete all as specified and directed. 51 S&F CP peg set of 6 hooks and including all accessories like screws etc as recommended by manufacturer and complete fixing in position complete all as specified. 52 S&F Stainless steel plate rack made out of 1 mm thick stainless steel sheet of size 900x750x250mm complete all as specified and directed. Wt shall not be less than 4kg. 53 Supply & fixed in repair Angular Stop Cock with wall flange, fency type chromium plated cast copper alloy screwed down, high pressure, screwed one ends for 15mm bore of iron pipe or for union and fixed in position complete in all respect all as specified. 54 Supply & fixed in repair PVC connections 15mm size with PTMT nuts of length 450mm. complete in all respect all as specified. 55 Supply & fixed in repair Chromium plated shower roses with or without swivel joints, any for 15mm pipes, including fixing to steel pipe or union. complete in all respect all as specified. 56 Supply & fixed in repair Pillar taps, fency type, long neck, cast copper alloy, with capstan heads, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts, screwed for 15mm bore of iron pipe and fixed in repairs all as specified. 57 Supply & Fixing acrylic glass shelf assembly for soapdish and appropriate space for placing other things like tooth brushes comb tooth paste etc and fiexed to walls with plug and brass chromium plated screws complete all as specified and directed. 58 Demolition of brickwork or stone/ boulder masonry, built in cement or cement lime mortar , including all quions, arches, pillars etc, but excluding ashlar facings, dressed stonework and precast concrete articles, complete all asspecified and directed by engineer in charge 59 Material & labour Brick work with sub class ‘B’ bricks, straight or curved on plan exceeding 6 metre mean radius in cement mortar (1:6), complete all as specified and directed by engineer in charge 60 Material & labour Brickwork with subclass ‘B’ bricks, straight or curved on plan to any radius in half brick thick walls built in with cement mortar(1:4), complete all as specified and directed by engineer in charge 61 Taking down chowkhats or frames (without taking off shutters from the frame) exc 1.5 Sqm and n. exc 4.00 Sqm complete all as specified. 62 Supply & fixing factory made Mild Steel Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,size 105x60mm necessary form work complete as specified. 63 Supply & fixing factory made Mild Steel Pressed steel frames made of MS sheet of 1.20 mm thickness for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc,size 125x60mm including necessary form work complete as specified, 64 Supply & fixing factory made flush shutters 35mm thick, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed. 65 Material & labour 35mm thick glazed and skelton shutters of 2nd class hard wood (factory made) open rebated and divided to receive glass,gauze etc (without sash bars) edges of framing plain,chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutter as specified in SSR Pt-I section 8 clause 8.24(a) supplied and fitted to chowkhats complete all as specified and directed. 66 Cutting holes in brick walls built in cement mortar for inserting holdfasts and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 complete all as specified and directed. 67 Material & labour PCC (1:3:6 ) type C-0 using 12.50 mm graded aggregate as infilling in PS Chowkhats/Holdfast Block all as specified . 68 Supply & fixing Butt hinges 100 mm size,medium weight stainless steel complete all as specified and directed. 69 Supply & fixing Aluminium alloy, anodised, sliding door bolt 250 mm length with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed. 70 Supply & fixing Aluminium anodised, barrel tower bolts of 200 mm size of extruded section and fixed complete all as specified and directed. 71 Supply & fixing Floor door stopper of size 140 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring,fixed in floor complete all as specified and directed. 72 Supply & fixing powder coated aluminium handles 125mm complete all as specified and directed. 73 Supply & fixing stainless steelHarrison rails, 25mm dia, chromium plated with fixing brackets, stops, rollers etc for curtain rod incl all fixing complete all as specified and directed by Engineer-in-Charge. 74 Supply & fixing 300mm, mild steel ordinary rat tail rod pattern springs including roller and roller plateincluding necessary welding to chowklhats complete fixed all as specified. 75 Taking down chokhats or frames (without taking off shutters from the frame) n.exc 1.50 sqm including cutting holes and making good reqd shape for hold fast block for new frame complete all as specified directed. 76 Material & labour factory made Solid PVC Door Frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, suppling & fixing in opening as per specification & drawing complete all as specified and directed by Engr-in-Charge. 77 Material & labour Factory Made Solid PVC Moulded Door Shutter, 28 to 30mm thick (stiles), with 2, 4, or 6 raised panel design with 2mm thick Moulded Prelam PVC Sheet on the front face & 2mm plain colour PVC sheet on back face, supplying & fixing in frame at site as per specification 78 Material & labour Built in cup boards with pressed steel frame of size 75x45x1.25mm thick and shutter of 1.00 mm thick MS sheet including spray painting 2 coats over a coat of red-oxide primer on steel surfaces all around (overall external size of cup board shutter incl frameshall be taken into consideration for the purpose of measurement) including One Nohanging rod of CP steel 20mm bore with brackets & two Nos peg set of three pegs each fixed inside the shutter complete fixed in repairs i.e, including taking down and removal of old unserviceable wooden or steel built-in-cupboards incl frame from site all as specified and directed by Engineer-in charge. 79 Material & labour for preparation of new steel surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified 80 Material & labour for Preparation of new wood surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified 81 Providing and fixing factory made extruded aluminium casement windows (with provision for cooler) with 50 micron powder coating doubled panelled anddouble shutters consisting of frame and mullion of 101.60X44.45X1.29 mm and shutters made of 63.5X31.75X1.29mm and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with and including 5mm thick glass in front shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperature in inner shutters complete fixed in all respect as specified including supply and fixing following items :-(a) Stainless Steel (304 Grade) Finished Butt Hinges 150mm -2 nos per leaf.(b) Powder Coated Aluminium Tower Bolt 150mm long - 2 nos per leaf.(c) Powder Coated Aluminium Handles 150 mm - 1 nos per leaf and incl hook and eye.Note: complete shutter window will be treated as single unit and paid as single unit 82 Supply & fixing stainless steel wire cloth 0.36mm nominal dia of wire and average width of aperature 1.40mm and fixed in repair with stainless steel wire stapples, in steel/wooden frame complete all as specified and directed. 83 Providing and fixing factory made extruded aluminium ventilators with 50 micron powder coating of frame of 63.5 X 38.10 X 1.29 mm including 5mm thick frosted glass in lower 55% portion of shutters and stainless steel wire gauge 0.36mm dia and 1.40 aperture in upper 45% portion of shutter and to be fixed with and including EPDM gasket to render the glazing, air and water tight etc. & aluminium beeds 20mm size with andcomplete fixed in all respect complete all as specified and directed by Engineer in charge. 84 Supplying and applying two component elastomeric acrylic polymer modified cementitious waterproofing coating, SmartCare Damp Block 2K or approved equivalent in Fosroc/Dr fixit, having 100%elongation as per ASTM D412, resisting 5 bars hyrostatic pressure as per DIN 1048, reduction to rapid chloride shall be 70 as per DIN 1048, crack bridging upto 1.2mm as per ASTM 4548.5. The coating shall have food grade certificate from laboratories like CFTRI. The mixing ratio of the coating shall be 2 parts of powder & 1 part of liquid without any water addition in the mixing, etc., complete as per manufacturer specifications.Make/Product: Sika or equivalent from Fosroc/Dr fixit 85 Supply and apply of rust remover cum passivator by brush in two coat @ 0.3 kg/m2/coat of Density: 1.01 Kg/l at 300C complete all as per manufacturers instructions and all as specified.Note : (i)Theapplication of rust removal shall be gotdone through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of work.Make/Product: Sika Rustoff 100 or equivalent from Fosroc/Dr fixit 86 Supply and apply cementitious coating for corrosion protection having a cement base polymer modified rebar corrosion protection system by applying the first coat approx 1mm thick layer of product carbonation resistance 2mm of sikatop ArmatecR -108 or equivalent in Fosroc/Dr fixit as specified corresponds to 20 mm of normal mortar;bond strength 1N/mm2 according to ASTM C 882-78 applying @ 4kg/m2 for two coats onto the prepared reinforcing steel with a medium-stiff brush.it is unavoidable that specified product will also be applied in the same way after a waiting time of 2-3 hours (+20C) complete all as per manufacturers instructions and all as specified.Note: The application of cementitious coating for corrosion protection shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.(ii) The applicator shall be got approved from GE before execution of work. Make/Product: Sika or equivalent from Fosroc/Dr fixitMake/Product: Sika or equivalent from Fosroc/Dr fixit 87 Material & labour Providing ,mixing & applying two components Epoxy resin concrete bonding coat on prepared RCC surfaces as per manufacturers apecification incl prepration of surface by chipping and throughly cleaning of surface complete wherever required and as per directions of Engineer-in-charge.Consumption: o.5 kg/m2 complete all as per manufacturers instructions and all as specified.Product requirements : complies with ASTM C 881 Type II Grade 2 class B+C.Note: (i) The application of epoxy bonding primer shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed.(ii) The applicator shall be got approved from GE before execution of work.Make/Product: Sika or equivalent from Fosroc/Dr fixit 88 Supply and apply a pre-batched one component polymer modifies cementitious patch repair mortar in 25mm thickness.Yield:approx 0.84 ltr/kg.System requirements:compressive strength =50 N/mm2 (28 days)according to ASTM C 109 : flexural strength = 3 N/mm2 (7 days)according to ASTM C 293-79consumption of 2.1 kg/sqm/mmNote: (i)The applicator of polymer repair mortar shall be got done through the authorised applicator of manufacturer of membrane only all as specified and directed. (ii) The applicator shall be got approved from GE before execution of work.Make/Product: Sika or equivalent from Fosroc/Dr fixit 89 S & Fpre-laminated PVC solid board 18-20mm thick pre-laminated both sides with wooden finished on one side and white finished laminated on other side as in cup-board front shutters complete fixed in position in all respect all as specified and directed by Engr-in-charge and including supply and fixing of following items:-(a) Stainless Steel (304 Grade) Finished tower bolt 100mm long -1 nos per leaf(b) Stainless Steel (304 Grade) FinishedHandles100mm - 1 nos per leaf(c) Stainless Steel (304 Grade) Finished magnectic catchers0 mm - 2 nos per leaf 90 S&F pre-laminated PVC solid board as in frames for cupboards shutters 40mm thick (doubled sandwiched of 20mm) prelaminated on one side with wooden finished complete fixed in position in all respect complete all as specified and directed. 91 S&F S & F Continuous (piano) hinges,mild steel, bright finish or elec trogalvanised in 30mm ) complete all as specified and directed. 92 Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed. 93 Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and directed by Engineer-in-Charge. 94 Taking down cement plaster of any description, any thickness from external surfaces of walls/soffits etc. incl raking out joints, hacking for keys, scrubbibg down with water etc complete all as specified and directed by Engineer-in-Charge. 95 Material & labour for cement plastering 15mm thick in two layers (10mm and 5mm respectively) in cemet mortar 1:4 including mixing of liquid water proofing compound as per manufacturers instructions on brick work or concrete surfaces or in chajjas/parapet walls etc finished even and smooth without using extra cement and fixing of chicken wire gauge where directed complete all as specified and as directed by Engineer-in-Charge. Note : WPC and chicken wire gauge will be measured and paid separately. 96 Supply only integral liquid water proofing compound complete all as specified & as directed by Engineer-in-Charge. 97 Material & labour for cement plastering 10mm thick in cemet mortar 1:6 on brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 98 Material & labour for cement plastering 10 mm thick in cemet mortar 1:3 as on ceilings or concrete surfaces finished even and smooth without using extra cement complete all as specified and as directed by Engineer-in-Charge. 99 Complete removal of existing treatment of any type/description from walls/RCC surfaces etc with mechanical means/grinder complete all as specified and directed. 100 Complete removal of existing treatment of any type/description from ceilings/RCC surfaces/soffits/chajjas etc with mechanical means/grinder complete all as specified and directed. 101 M&L for applying acrylic thick wall care putty on internal/external surfaces of walls/ceilings/soffits (thickness vary from 0.5 to 1.0 mm as required for desired smoothness and levelling of surfaces in two or more layers) by using ready made wall care putty including sand papering after filling the putty to make surface smooth and ready for receiving painting etc complete all as specified and directed 102 Material & labour Applying 02 coats of exterior emulsion weather proof paint (light shade) to external newplastered walls/RCC surfaces/soffits of chajjas/roof projections/ cantilevers/ balcony etc surfaces over & including a coat of exterior primercomplete all as specified and directed. 103 Material & labour Applying one coat of exterior emulsion weather proof paint (light shade) to external old plastered walls/RCC surfaces/soffits of chajjas/roof projections/ cantilevers/balcony etc surface complete all as specified and directed. 104 Material & labour Applying 02 coats ofoil bound distemper (light shade) to new plastered wall surfaces overcomplete all as specified and directed. 105 Material & labour Applying one coat of interior oil bound distemper (light shade) to old plastered wall surfaces complete all as specified and directed. 106 Material & labour for preparation of newplastered surfaces of ceiling and applying three coats of white wash , complete all as specified and directed by Engineer-in-Charge. 107 Material & labour for preparation ofold plastered of ceiling and applying one coat of white wash complete all as specified and directed by Engineer-in-Charge. 108 Supply & fixing Mild steel, plain, black sheet 3mm thick in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed by engineer-in-charge. 109 M & L for mild steel framed work as in brackets etc for cooler stands,supportings frame workfor sun shadeetc framed steps/stairs etc complete using MS railing/angle iron Steel bars gusset plate etc complete all as specified & directed complete. 110 Material & labour for Cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate as in plinth protection/ floor finish, 50 mm thick, surfaces finished even and smooth without using extra cement as in plinth protection including provision of construction joints filled with Bituminous mastic asphalt complete all as specified and directed by Engineer-in-Charge. 111 Material & labour for Repair to RCC sunshades, Chajjas, Balconies, Columns, bands, beams and similar RCC work at any position/height by dismantling loose/disintegrated portion and dubbing out with Cement Concrete 1:1½:3, 15mm to 50mm thick using 6 to 12mm graded stone aggregate to make up and finished to required shape including provision of necessary supports if required and stitching of cracks with mild steel U clamps made out of 8mm dia @ 150mm c/c with inserting concrete block stretcherwith cement mortar 1:3 mixed with adhesive chemical (Polymer based) and reinforced with PVC chicken mesh including form work where ever required and finished with10 mm thick plastering in CM 1:4 finished even and fair without using extra cement including preparation of surfaces to receive finishes complete all as specified and directed. 112 Takingdown carefully existing points wiring on surface conduit/concealed conduit including conduit from surface and expect conduit in concealed wiring for light/fan/socket/power/bell from wall & roof along with fitting and fixtures such as switches, sockets, ceiling roses, batten holders, unserviceable light fittings, pieces of wires, gutties, conduit, wooden boards etcremoving materials to store for keeping in safe custody of contractor for which the credit has been considered under schedule of creditand making good the disturbed portion of all floor, ceiling etc all as specified and directed. 113 Point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light/fan/bell in new PVC conduit to be terminated in pressed steel terminal boxes with top cover plateincluding 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directedby Engineer in-charge Note-I-(Switches and regulators shall be measured and paid for separately). Note-II- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-III- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -IV - cost of Eye/bottle thimblesused for connection in switches/sockets & MCBs in DBs is deemed to be included in the unit rate quoted for this item. Note:- V- Rate of cutting chasing included in the unit rate quoted for this item 114 M & L for point wiring with 1.5 sqmm PVC insulated and unsheathed FRLSH single core multi-stranded copper conductor for one light point controlled by 2 way and including PVC rigid concealed conduit medium grade 19/20 mm dia to be terminated in pressed steel terminal boxes with top cover plateincluding 1.5 sqmmPVC insulated and unsheathed FRLSH single core multi-stranded copper earth continuity conductor controlled by one switch and/or one regulator complete including repairing the surfaces in CM 1:3 and finishing the surface as per existing treatment all as specified and directed.Note-I- ( Wiring shall be done as per colour code in IS for phase, neutral and earth). Note-II- (The cost of modular cover plate and metal flush boxes is deemed to be included in the unit rate quoted for this item). Note -III - cost of Eye/bottle thimblesused for connection for 2 way switch is deemed to be included in the unit rate quoted for this item. Note:-III- Rate of cutting chasing included in the unit rate quoted for this item 115 All as per Sl item No 113.00 above herein before but one socket out let 5 pins 5 Amp on the same board with other switches complete all as specified and directed. 116 All as per Sl item No 113.00 above herein before but for one socket out let 5 pins 5 Amp on independent board complete all as specified and directed. 117 All as per item No.113.00 herein beforebut 2.5 Sqmm PVC insulated and unsheathed FRLSH single core multistranded copper conductor incl 2.5 Sqmm PVC insulated and unsheathed FRLSHcopperearth wire for switch socket combination 3 pin 15 amps on independent board. 118 Supply & fix in replacement of Modularswitch1 way, 6 Amps, 1 module, 230 volts complete all as specified. 119 Supply & fix in replacement of Modularswitch2 way, 6 Amps, 1 module, 230 volts complete all as specified. 120 Supply & fix in replacement of Modularswitch1 way, 16 Amps, 1 module, 230 volts complete all as specified. 121 Supply & fix in replacement of Modularbell push switch1 way, 6 Amps, 1 module complete all as specified. 122 Supply & fix in replacement of Call bell ding dong AC 230 volt single pole complete all as specified. 123 Supply & fix in replacement of Modular socket 5 pin 6 Amps, 2 module 230 volts complete all as specified. 124 Supply & fix in replacement of Modularsocket 5 pin 6 &16 Amps, combination type2 module complete all as specified. 125 Supply & fix in replacement of Modular Fan regulator step type, 120 watts, 2 module complete fixed as in repair all as specified. 126 S&F ceiling rose surface bakelite surface 65 x 50mm3 terminals all as specified & directed 127 Lamp holder including LED bulb 9 W including flexible wire 0.5 Sqmm copper cable all as specified & directed by Engr-in-charge. 128 New generation energy saving and environmental friendly long life LED building security light 1x35 watts made up of pressure die cast alluminium housing with high power LED as light source and lense embedded PC cover having TOP OPENING separate driver compartment with IP65 protection and impact resistance of IK07,with all accessories including suitable bracket with 32mm bore light grade GI pipe bemd to shape, including MS clamp of size of required size and PVC cable 1.5 Sqmm twincore from ceiling rose to light fittings complete all as specified and directed by Engineer-in-charge. 129 Surface Mounted LED Bulk Head Luminaire of capacity 10 watt with ABS Body & Polycarbonate Diffuser, IP54 inc connection with ,with flexible wire 0.5 sqmm copper cable all as specified & directed by Engr-in-charge. 130 M & L for Sub main wiring with two single core 6.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 6.0 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge.Note 1:-2(two) Runs of 6.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Run of 6.00 Sqm Copper conductor Earth wire shall be measured as one unit)Note 2 :(i) Rate quoted for this items shall be inclusive of the cost of (i) Rigid non-metallic PVC conduit of 25 mm dia with tees, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces and cutting not exc.10 cm girth . (iii) Including taking out/down existing unserviceable sub main wiring. 131 M & L for Sub main wiring with two single core 4.0 Sqmm PVC insulated and unsheathed FRLSH,stranded copper conductor cable drawn through PVC concealed conduit 25 mm dia including 4 Sqmm PVC insulated unsheathed FRLSH stranded copper conductor cable as earth wire all as specified and directed by Engineer-in-charge. Note 1:- 2 Runsof 4.00 Sqmm Copper conductor cable, 1 Run of PVC conduit & 1 Runof 4.00 Sqm Copper conductor Earth wire shall be measured as one unit) Note2 : Rate quoted for this items shall be inclusive of the cost of(i) Rigid non-metallic PVC conduit of 25 mm dia withtees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc.(ii) Cutting chases, pinning in making good to facing where required and pointing in cement mortar 1:3 to match the existing surfaces, cutting not exc.10 cm girth . (iii) Taking out/down existing unserviceable sub main wiring. 132 MCCB, 4 Pole, 63 A, 16 KA for fixing in DB including proper thimble connection, thermal and magnetic release protectioncomplete all as specified and directed by Engineer-in-charge. 133 Supply and fix epoxy power coated MCCBdistribution box double door VTPN 4 way vertical type AC 415 V with IP 43 protection for MCBs alongwith provision of MCCB as incomer with commen bus-bar at incoming end of outgoing MCBs grouted/ flush to wall, complete all as specified by Engineer-in-charge. (Note :- MCCB will be measured and paid under seperate item) (i) Cost of Eye/bottle thimblesused for connection MCBs in DBs shall deemed to be included in unit rate quoted for this items, (ii) Electric wiring should be done in proper colour coding i.e. Red for phase, Black for neutral and Green for Earth.(iii) connection of theMCCBs/ MCBs with cableshall be made through appropriate size pin /bottle type thimble -properly crimped. all the vacant holes of the DB shall be provided with blank plates of appropriate size. 134 Supply and fix Sheet metal enclosure 8 ways double door for DBs when MCBs areto be used 240,volts including 200 Amps standard bus bar of suitable size and common neutral link allflush mounting type, drilling holes for incoming and out going cables with IP 43 protection complete all as specified & directed byEngr-in-charge. 135 Supply and fix MCB , SPN, 240 Volts ,32-40 amp for fixing in DBs ofincluding proper thimble connections complete all as specified and directed by Engineer-in-Charge. 136 Supply and fix MCB, single pole 240 volts 6 to 32 Amp capacity for fixing in DB’s including proper thimble connections complete all as specified and directed by Engineer-in-Charge. 137 M & L forEarthing complete with galvanized iron earth plate electrode of size 600x600x6.0mm , buried directly in ground (earth pit not less than 2.25 mtrs below normal ground level) with top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanized earth lead wire 4.0 mm dia by means of bolts , nuts , check nuts and galvanized iron or steel including earth work in any type of soil, charcoal salt 15 cm around the earth plate 20 mm dia watering pipe medium grade 1.70 mtr long with a plug at top, GI protection pipe light grade 15 mm dia from earth pit to main board including PCC pit in cement concrete 1:2:4 along with CI frame and cover 10mm thick duly hinged to CI frame as shown in the electrical plate No3 of SSR 2009 part 1 all as specified and directed by Engr-in-charge. 138 Supply and fix Tube light fitting Self Ballasted LED Batten. Extruded Thermoplastic body with PC Diffuser in squareLED Batten 18/20W 6500Kof capacity ,20 watt,4 ft long incl 3 core flexible wire 0.5 sqmm copper cable all as specified and directed by Engr-in-charge. 139 Supply and fix in replacement of elegatly designed sleek surface mounted pressure die-cast aluminiumLEDluminaire in powder coated white finish in round profile with optimized heat sink for efficient heat dissipation and independent electronic LED driver of capacity 12 W LED of 5000 K and making good the existing surface as per existingcomplete all as specified & directed. 140 Supply and fix Exhaust fan AC single phase 230/240 v of size 300 mm sweep 900 rpm metal body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including hole making Louver complete all as specified and directedby Engineer-in-Charge. 141 Taking down and refixing of Geysers of capacity 25 Ltrsafter necessary cleaning painting making serial No complete all as specified and directed by Enginner-in-charge. 142 Supply and fix Exhaust fan AC single phase 230/240 v of size 250 mm sweep 900 rpm Engineering thermoplastic body, high efficiency motor, dynamically balanced blade for better performance and corrosion-resistant powder coated metallic finish including hole making Louver complete all as specified and directedby Engineer-in-Charge. 143 Supply and fixingsingle pole and neutralenclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amps, complete all as specified and as directed by Engineer-in-charge. 144 M&L PVC Meter Box of suitable size for single phase LT meter. door with 1 Nos of transparent glass of suitable for visibility of meter fixed on door with suitable arrangemnets. meter box shall be fixed in wall and necessary chiseling and make good of wall to be included in quoted cost.NOTE:-To fix the meter box required disconnecting and refixing of connections to be included in quoted rate. 145 Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for laying of cables including getting out in any kind of soil complete all as specified and directed. 146 Returning filling in including spreading, levelling, and well ramming, in layers not exceeding 25 cm thick each layer of any kind of soil. 147 Removing surplus excavated material from site not exceeding 50 mtrs from starting point and depositing where directed at a level not exceeding1.5 mtr above the starting point. 148 Material and labour for sand cushioning for cables 8 cm below the cable and 15 cm abovewith dry river sand in trenches for cushioningof underground cable line including spreading, leveling, well ramming completed all as specified and directed. 149 Cutting of hardstanding floor/wall for laying of cable including matching with suface by using cement concrete 1:2:4 type B-0 all as specified and directed. 150 Supplying & laying factory made unreinforced Precast concrete cable coversclass LV type 1, flat, Size 250x150x40mm laid in trenches as protection to cables completeall as directed by Engr-in-Charge 151 Material and labour for replacement of GI tubing light grade 40 mm borefor passing through cables under the floor ,along the wall or along the pole complete all as specified and directed. 152 S&F XLPE Insulated ,screened, PVC bedded, galvanized steel wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core supplied& laid in replacement complete all as specified& directedby Engineer-in-Charge.

Key Value

Document Fees
INR 500 /-
EMD
INR 75740.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail