}

Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth, 1.5M In Width As Well As 10 Sqm On Plan) , gauriganj-Uttar Pradesh

Uttar Pradesh Housing And Development Board has published Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth, 1.5M In Width As Well As 10 Sqm On Plan) . Submission Date for this Tender is 08-08-2025. Building Work Tenders in gauriganj Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

50201898
Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth Work In Excavation By Mechanical Means (Hydraulic Excavator) / Manual Means Over Areas (Exceeding 30Cm In Depth, 1.5M In Width As Well As 10 Sqm On Plan)
Tender
Indian
Uttar Pradesh
Gauriganj
08-08-2025

Tender Documents

Tender Details

Tender For Construction Of Administrative Building Of Cyber Thana At Gauriganj Distt Amethi - Earth work in excavation by mechanical means (Hydraulic excavator) / manual means over areas (exceeding 30cm in depth, 1.5m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth, lead up to 50m and lift up to 1.5m,as directed by Engineer-in-Charge. All kinds of soil 2 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 1.5 m to 3.0 m). 3 Extra for every additional lift of 1.5 m or part thereof in excavation / banking excavated or stacked materials. In all kind of soil. (For 3.0 m to 3.3 m). 4 Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift 5 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 6 Providing and laying in position cement concrete of specified grade excluding the cost ofcentering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) ,including cost of form- work,in foundation and floors. 7 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all completeupto/aboveplinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 9 Centering and shuttering including strutting, propping etc. and removal of form for all heights : 10 Foundations, footings, bases of columns, etc. for mass concrete. 11 Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. 12 Lintels, beams, plinth beams, girders, bressumers and cantilevers. with water proof ply 12 mm thick 13 Columns,Pillars, Piers, Abutments, Posts and Struts. 14 Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. 15 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7 kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. 16 Providing and injecting chemical emulsion for preconstructional antitermite treatment and creating a chemical barrier under and alround the column pits wall trenches basement excavation top surface if plinth filling junction Of wall and floor, along the the external perimeter of binding expansion joints, surrounding of pipes and conduits etc, complete (plinth area of the building at ground floor only shall be measured as per I.S.6313(Part II 1981)Alderine emulsifiable concentrate or any other approved material such as Heptrachlor or chordancewill be used The rate of application of chemical emulsion shall be as follows ; (1)Treatment for masonary & foundation 5 liters per/ 100 sqm. (2) Back fill in immediate contact with foundation 7.5 liters/100sqm (3) Treatment of top surface of plinth filling 5 liters/100 sqm (4)Treatment junction of wall and the floor 7.5 liters/100 sqm (5)Treatment Of soil along external perimeter of building 7.5 liters/100sqm. (6) Treatment Of soil under apron along external perimter 5 liters/100 sqm. 17 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in.foundation and plinth in :Cement mortar 1:6 (1 cement : 6 coarse sand) 18 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up tofloor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 19 Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). 20 Providing and laying cement concrete in kerbs, steps and the like at or near ground level excluding the cost of centering, shuttering and finishing. 1:1½:3 (1 Cement: 1½ coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) 21 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 15 in superstructure above plinth level up to floor V level in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 22 Half brick masonary with common burnt clay ( non modular) bricks of class - 150in superstructure above plinth level up to floor V level Cement mortar 1:4 (1 cement :4 coarse sand) 23 Providing and fixing bright /matt finished Stainless Steel sliding door bolts of approved quality & make with necessary screws etc all complete. 250mm x 16mm . 24 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 250mm x 10mm . 25 Providing and fixing bright /matt finished Stainless Steel tower bolts of approved quality & make with necessary screws etc all complete. 150mm x 10mm . 26 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 125 mm 27 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 100 mm 28 Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete 29 Providing and fixing aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with ISi, IS : 3564, embossed on the body, door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with double speed adjustment with necessaryaccessories and screws etc. complete. 30 Providing and fixing M.S. Tubular frames for doors, windows, ventilators and cupboard with rectangular/ L-Type sections, made of 1.60 mm thick M.S. Sheet, joints mitred, welded and grinded finish, with profiles of required size, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.Fixing with 15x3 mm lugs 10 cm long embedded in cement concrete block 15x10x10 cm of C.C. 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) 31 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :4.0 mm thick glass panes 32 Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction with frame of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on bothfaces of shutters:35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 33 Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). 34 Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.1.0 mm thick 35 Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured). 36 Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding 37 Providing & fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc. including welding, grinding, buffing, polishing & making curvature (wherever required) & fitting the same with necessary stainless steel nuts & bolts complete i/c fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Eng-in-charge. (weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.) 38 Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete.Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides 39 Providing and fixing 1mm thick M.S. sheet door with frame of 40x40x6 mm angle iron and 3 mm M.S. gusset plates at the junctions and corners, all necessary fittings complete, including applying a priming coat of approved steel primer. Using M.S. angels 40x40x6 mm for diagonal braces 40 Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. 41 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations:(a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface beforetreatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compoundconforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge :22.7.1 With average thickness of 120 mm and minimum thickness at khurra as 65 mm. 42 15 mm cement plaster on rough side of single or half brick wall of mix :1:6 (1 cement: 6 coarse sand) 43 12 mm cement plaster of mix : 1:6 (1 cement: 6 coarse sand) 44 15 mm thick plaster in 1:4 cement & course sand on outer wall below Ground level & inner wall below plinth level in 15 cm width. 45 Add for plaster drip course/groove in plastered surface or moulding to R.C.C. projections 46 Cement plaster skirting up to 30 cm height,18 mm thick, with cement mortar 1:3 (1cement : 3 coarse sand), finished with a floating coat of neat cement. 47 Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. 40 mm thick with 20 mm nominal size stone aggregate 48 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 12 mm cement plaster 49 Cement plaster 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster 50 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. 51 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approvedmake, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 52 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600x600 mm [IN FLOORING] 53 Providing and laying Vitrified tiles in different sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joint with white cement & matching pigments etc.complete.Size of Tile 600x600 mm 54 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills , facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) : 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Dark shade pigment using ordinary cement 58 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ .90 kg/ 10 sqm) 59 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour. New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre . 60 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 61 Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture 62 Painting wood work with Deluxe Multi Surface Paint of required shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @0.75 ltr/ 10 sqm of approved brand or manufacture 63 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 64 Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter 65 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm 66 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. 67 Coupler 110 mm 68 Bend 87.5° 110 mm bend 69 Shoe (Plain)110 mm Shoe 70 Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. 71 Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : (a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/ sqm. This layer will be allowed to air cure for 4 hours. (b) Second layer of slurry of cement @ 0.242 kg/sqm mixed with water proofing cement compound @ 0.126 kg/sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours.The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry 72 Supply and filling of light weight cinder filling in sunken portion of 1st floor toiletincluding watering ramming etc, complete the cost of including material and labour 73 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation,levelling & dressing & finishing the top smooth 74 Brick edging 7cm wide 11.4 cm deep to plinth protection with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 including grouting with cement mortar 1:4 (1 cement : 4 fine sand). 75 Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage. 76 For vertical surface two coats @ 0.70 kg per sqm 77 For horizontal surface one coat @1.10 kg per sqm. 78 Providing and fixing 12mm thick frameless toughened glass door shutter of approved brand and manufacture, including providing and fixing top & bottom pivot & double acting hydraulic floor spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer in charge (Door handle, lock and stopper etc. to be paid separately) 79 Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness 80 Providing and fixing bright /matt finished Stainless Steel D Type handles of approved quality & make with necessary screws etc all complete. 600 mm long 25 mm dia 81 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content,the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level Concrete of M30 grade with minimum cement content of 350 kg /cum Water tank 82 Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm Sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. 83 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required:W.C. pan with ISI marked white solid plastic seat and lid 84 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap 85 Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern 86 Providing & fixing stone slab table rubbed, edges rounded and polished of size 75 X 50cm deep and 1.8 cm thick fixed in urinal patitions by cutting chase of appropriate width with chase cutter and embedding the stone in chase with epoxy grout or with cement concrete 1:2:4 ( 1 cement : 2 coarse sand : 4 graded stone aggregste 6mm nominal size) as per Engineer-in-charge and finished smooth Granite stone of approved shade 87 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 88 Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.Flexible pipe i) 32 mm dia 89 Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. 90 Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6 mm thick hard board backing :Circular shape 450 mm dia 91 Providing and fixing toilet paper holder :C.P. brass 92 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work. 93 90 mm O.D. 94 110 mm O.D. 95 Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.110 mm 96 Supply and fixing of UPVC S.W.R. door bend confirming to IS- 14735 97 90 mm size 98 110 mm size 99 Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.BEND 87.5° 75 mm Shoe 100 Supply and fixing of UPVC S.W.R. Plain Tee confirming to IS- 14735 101 90x90x90 mm size 102 110x110x110 mm size 103 Supply and fixing of UPVC S.W.R. Plain bend confirming to IS- 14735 104 90 mm size 105 110 mm size 106 Supply and fixing of UPVC S.W.R. Door Y confirming to IS- 14735 107 90 mm size 108 110 mm size 109 Supply and fixing of UPVC S.W.R. Cowel confirming to IS- 14735 110 90 mm size 111 110 mm size 112 Supply and fixin g of UPVC S.W.R. Nahni trap size 100/75mm, 100/90mm confirming to IS - 14735 self cleannig design fixed in PCC 1:2:4 and supply and fixing of 125mm dia heavy duty CP brass jali. 113 Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not less than 105 gms. 114 Providing & fixingPTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealedfittings arrangement of approved quality and colour weighing not less than 88 gms 115 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply and all CPVC plain & brass thermal stability for hot & cold water supply and all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing.cement and testing of joints complete as per direction of Engineer in charge Internal work - Exposed on wall 116 20 mm nominaldia pipes 117 25 mm nominaldia pipes 118 40 mm nominaldia pipes 119 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings, with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 120 15 mm nominal outer dia pipes 121 20 mm nominal outer dia pipes 122 25 mm nominal outer dia pipes 123 Providing and fixing of gun metal gate valve with CI wheel of approved quality (screwed ends) 124 25mm dia, nominal bore 125 32 mm dia, nominal bore 126 40 mm dia, nominal bore 127 50 mm dia, nominal bore 128 Providing and fixing uplasticised PVC connection pipe with brass unions :45 cm length 15 mm nominal bore 129 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : 130 20 mm nominal bore 131 25 mm nominal bore 132 Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 15mm nominal bore 133 Providing and fixing C.P.brass angle valve for basin mixer and geyser points of approved quality conforming to IS 8931 a) 15 mm nominal bore. 134 Providing and fixing 8 mm dia C.P. / S.S. Jet with flexible tube upto 1 metre long with S.S. triangular plate to Eureopean type W.C. of quality and make as approved by Engineer - in - charge. 135 Supply and fixing of UPVC S.W.R. pipe type -B confirming to IS- 13592 including jointing the pipes with rubber ring, lubricant and UPVC SWR cuplar confirming to IS - 14735. Also including excavation of trenches cutting of walls and holes and repairing the walls floors and refilling the trenches as before but excluding supply and cost of other fittings such as elbow, bead, tee and Y-tee including supply of all material labour and T&P .Required for proper completion of the work.160 mm O.D. 136 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) all-round S.W. pipes including bed concrete as per standard design : 160/150 mm diameter pipe 137 Supply and fixing of UPVC S.W. R. Gully trap confirming to IS - 14735 size 150x110 mm dia of self cleaning design including fixed brick Masonary chamber 250x250x250mm Size i/ c supply and fixing of CI cover with frame weight not less then 4.50Kg. & CI grating 150x150mm complete in all respects. 138 Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand ) with R.C.C. top slab with 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:4:8 mix (1 cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) Fisnihed with a floating coat of neat cement complete as per standard design : 139 Inside size 90x80 cm and 45 cm deep including C.I.cover with frame (light duty) 455x610 mm internaldimensions, total weight of cover and frame to be notless than 38 kg (weight of cover 23 kg and weight offrame 15 kg) 140 Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg(weight of cover 58 kg and weight of frame 58 kg) : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 141 Extra for depth of man hole size 90x80 cm With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 142 Providing and fixing square mouthS. W. Gully trapSP 1 complete with C.I. gratingbrickmasonry chamber with F.P.S bricks and water tight CI cover with frame of 300 x 300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 180 x 150 mm. size P type 143 Providing orange colour safety foot rest of minimum 6mm thick plastic encapsulated as per IS : 10910 on 12mm dia steel bar conforming to IS: 1786 having minimum cross section as 23 mm x25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruded legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufacturess permanent identification mark to be visible even after fixing, including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete as per design. 144 Constructing masonry Chamber 90x90x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement :4 coarse sand ) for sluice valve, with C.I. surface box 100mm top diameter, 160mm bottom diameter and 180mm deep (inside) with chained lid and RCC top slab 1:1.5:3 mix (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design :With F.P.S. bricks 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with onestep CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 146 50mm nominal bore. 147 40mm nominal bore. 148 32mm nominal bore. 149 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C 150 Wiring for twin control light point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit, 2 way modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc. as required. 151 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 152 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 153 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire 154 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 155 2 X 6 sq. mm + 1 X 6 sq. mm earth wire 156 4 X 6 sq. mm + 2 X 6 sq. mm earth wire 157 4 X 10 sq. mm + 2 X 6 sq. mm earth wire 158 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm 159 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 160 5/6 A switch 161 3 pin 5/6 A socket outlet 162 Supplying and fixing Telephone socket outlet modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 163 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 164 Supplying and fixing (75mmX75mm) size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required.1 or 2 Module ) 165 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 166 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 167 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.Upto 450 mm sweep 168 Extra for fixing the Louvers/ shutters complete with frame for exhaust fans of all sizes. 169 Supplying and drawing 2 pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 170 Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing. 171 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 172 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. (for A.C. Point/MCB Point) 173 Supplying and fixing PVC batten/ angle holder including connections etc. as required. 174 Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 175 4 way (4 + 12), Double door 176 6 way (4 + 18), Double door 177 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole 178 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 179 Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A 180 Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A 181 Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 182 40 A 183 63 A 184 Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. 185 Supply and burying of Safe Earthing Electrod T-19 Zn-Zinc Coated, Length 3000mm, outer pipe 48.4mmx3.2mm, inner pipe 26.9mm x 2.6 mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCm) having anti corrosive& conductive property with 50 Kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board,cost of 25x3 G.I. Strip will be extra) Make : As approved in U.P.P.W.D. & C.P.R.I. Certified. 186 Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with G.I. nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of G.I. nut bolt & spring washer spaced at 50mm) 187 Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required.100 mm dia 188 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 189 Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCBs (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle TypePower Panel :Incoming -200 Amp MCCB - 1 No.Outgoing - 40 Amp 4P MCCB - 4 Nos.63 Amp 4P MCCB - 2 No. 63 Amp 4P MCCB - 1 No.(Complete as per requirment directed by Project Manager.) 190 Supply and fixing of LED Tube Light with Metal heavy duty Box type batten Light fitting 1X22 watt suitable for upto 1X22 watt LED Polycarbonate tube light complete Including tube suitable for both surface & suspended complete in all respect.CAT. - AAA 191 Supply & fixing of IP 20, Frount Mid Power SMD type LED LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 192 Supply & fixing of IP 20, Mid Power SMD type LED1*1 square LightSurface mounting round 18 to 20 Watt Cut out Min 150 mm, Height Min 40mm/ Led Down Lighter having Powder coated die cast aluminium housing with heat sink ,high durity/transmisivirty uv stabilised non yellowish diffuser /reflector for uniform light distribution detachabledriver set suitable for 24 hrs continuous operation ,complete in all respect.CAT. - AAA 193 Supply and fixing of water tight oblong 10 Watt LEDbulk head luminaire having die cast housing with driver set confirming to IP 65 and above Protection.Complete in all respect. CAT. - AAA 194 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules. 195 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size 196 size 6 sq mm x 2 core 197 size 70 sq mm x 3-1/2core 198 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required. 199 2 X 6 sq. mm (19mm) 200 3½ X 70 sq. mm (32mm) 201 Supply & fixing of 12 Watt LED Bulb - B22 / E27 (Colour Temp.- 6500K / Lumens - 900 lm) cool day light, Input Volts (AC 90V-260V), 3-Star rating suitable for Batten/Angle holder including making connection.Complete in all respect. 202 Supply & fixing of 225/300mm sweep ventilating (Light Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Copper motor for high air suction performance /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 45 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Motor type : Normal Speed. Complete in all respect. 203 Supply & fixing of 300mm sweep ventilating (Medium Heavy Duty) exhaust fan complete with Metallic Blade (Steel bird guard protector /Double ball bearing /Copper motor /Capacitor etc.), Noise level : (45 - 50) dB, Power consumption : 70/85 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 900/1400 RPM. Complete in all respect. 204 Supply & fixing of 400mm sweep wall mounted (Light Duty) fan complete with Plastic Blade & Pull Cord (Adjustable upward and downward tilt mechanism /motor /capacitor etc.) Oscillation degree - 90, Power consumption : 60 W, Rated voltage : 230 V, Rated frequency : 50 Hz, Speed : 1350 RPM. Complete in all respect. 205 Supply & Fixing of LAN socket outlet modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc. Complete in all respect. 206 Supply and fixing of 600 mm long cross arm of 50 mm x 50 mm x 6 mm mild steel angle iron with necessary clamps, bolts, nuts etc. on wall Complete in all respect. 207 Supply and fixing of factory wired integral LED flood light luminaires with die cast aluminium housing built with driver set suitable for 100 to 120 Watt. Confirming to IP 65 Protection complete in all respects. CAT AAA 208 Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 60 watt to 72 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . 209 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System)and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop 210 Supplying, installation, testing & commissioningof intelligent analog addressable photothermal (Smoke) detector complete with mounting base complete as required. 211 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 212 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 213 Supplying, installation, testing & commissioning of intelligent addressable thermal detectorwith rate of rise cum fixed tempreature thermistor complete with base as required. 214 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 215 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 216 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 217 Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. 218 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required. 219 Supplying, installation, testing and commissioning of electric driven terrace pump suitable for automatic operation and consisting of following, complete in all respects, as required : Horizontal type, multistage, centrifugal, split casing pump of cast iron body & bronze impeller with stainless steel shaft, mechanical confirming to IS : 1520Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase, 50 Hz, AC supply with IP55 class of protection for enclosure, horiziontal foot mounted type with Class-F insulation, conforming to IS-325.M.S.fabricated common base plate, coupling, coupling guard, foundation bolts etc.as required.Suitable cement concrete foundation duly plastered and with anti vibration pads.450 lpm at 35 m HeadTerrace Pump 220 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbows, tees, flanges, tapers, nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of synthetic enamel paint of required shade complete as required : 221 80 mm dia 222 100 mm dia 223 Supplying and fixing single headed Internal Hydrant Valve with instantaneous Gunmetal/Stainless Steel coupling of 63 mm dia with cast iron wheel ISI marked conforming to IS 5290 (Type -A) with blank Gunmetal/Stainless Steel cap and chain as required :Single headed Stainless steel 224 Supplying, fixing, testing and commissioning of Butterfly Valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required : 225 80 mm dia 226 100 mm dia 227 Supplying and fixing Orifice Plate made out of 6 mm thick stainless steel (Grade 304) with orifice of required size to be fitted between flange & landing valve of external and internal hydrants to reduce pressure at the outlet to the level of 3.5 kg/cm2 complete as required. 228 Providing, installation, testing and commissioning of Non-Return Valve of following sizes confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required : 229 80 mm dia 230 100 mm dia 231 Providing, installation, testing and commissioning of stainless steel Y-Strainer fabricated out of 1.6 mm thick stainless steel, Grade 304, sheet with 3 mm dia holes with stainless steel flange.100 mm dia 232 Supplying and fixing 63 mm dia, 15 m long RRL Hose Pipe with 63 mm dia male and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as required :Stainless Steel (Grade 304) 233 Supplying and fixing First-Aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket. 30 m 234 Supplying & fixing 63 mm dia gun metal short Branch Pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Stainless Steel (Grade 304) 235 Supplying and fixing of Fire Brigade Connection of cast iron body with gun metal male instantaneous inlet couplings complete with cap and chain as reqd. for suitable dia MS pipe connection conforming to IS 904 as required :2 way - 100 mm dia M.S. Pipe 236 Supplying and fixing Air Vessel made of 250 mm dia, 8mm thick MS sheet, 1200 mm in height with air release valve on top and flanged connection to riser, drain arrangement with 25 mm dia gun metal wheel valve with required accessories, pressure gauge and paintingwith synthetic enamel paint of approved shade as required. 237 Providing & fixing of Pressure Switch in M.S. pipe line including connection etc. as required. 238 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following sizesize 25 sq mm x 3-1/2core 239 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 25 sq. mm (28mm) 240 Supply and fixing of fire extinguisher, ABC Type 6.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 241 Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. 242 Supply and fixing of fire bucket, round bottom made of G.I. sheet 9-11 litres capacity duly painted as per fire brigade design, supported on hanging bracket chained and locked, initially filled with fine river sand, water as per directions of Engineer-in-Charge. 243 Supply and Laying of 1800*900*12mm thick chequerd rubber matting of tested quality. complete in all respect. as per I.E. Rules 244 Providing & fixing carbon steel Fire Man Axe with rubber insulated handle tested to 20000 volts. 245 Providing and Fixing of Self illuminated /Auto Glow Exit Signs printed on photo-luminescent sheet containing self illuminated base chemical,of appropriate size not less than 400x150mm,suspended from ceilling or fixed to the walls with accessories as riquired and as directed at site. 246 Providing & fixing dial type (150 mm dia) Pressure Gauge with isolation ball valve suitable for working pressure of 250 PSI cost shall be of inclusive of providing any short pieces, nipples, elbows etc as required.having calibration of0-15 Kg/cm2. 247 Providing, fixing, testing & commissioning of resilient rubber lined single Arch Vibration Eliminators suitable for raw water up to 45oC temperature, working pressure 8.8 Kg/cm2 and test pressure 20 Kg/cm2 for :-100 mm dia 248 Providing & fixing cast iron air release valve of 25 mm dia including 25 mm dia Ball valve with fittings etc. as per the requirement. 249 Providing & Fixing of 1.6 mm thick M.S/Door Frame, Door capable of accommodating fire Hose Reel, Landing Valve, Hose Pipes, fittings & accessories. The door shall have a front glass with lock and key arrangement & shall be painted with post office red colour (approval shall be taken on the basis of submitted sample before ordering) Cost of fire extinguishers not included in item rate. (Liasioing with civil contractor for makingRecessed type mansoary box (by civil contractor).750x600x250 mm ( Cabinet) 250 Fabrication, supply, Insallation testing & commissioning of Electrical control panel of cubical construction, floor mounted type, fabricated out of 2mm thick CRCA sheet, compartmentalised with hinged lockable doors, dust and vermin proof, powder coated of approved shade after 7 tank treatment process, cable alley, interconnection with suitable size copper conductor cable/solid copper strip, having switchgears and accessories, mountings and internal wiring, earth terminals, numbering etc. complete in all respect, suitable for operation on 415V, 3 phase, 50Hz Ac Supply with enclosure protection class IP 42 as required :63 Amp, 35kA TPN MCCB, Ics=100% Icu, with Suitable HP fully automatic Star/Delta starter with overload protection, current sensing type single phase preventor complete with all acceessories and internal wiring required for automatic operation, selector switch for local/remote, auto/manual/OFF operation. -1 Set 251 Providing and laying Separation Membrane of impermeable plastic sheeting 125 micron thick as per direction of engineer in charge. 252 Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earth with lead upto 50 metres. 253 Construction of granular sub-base by providing close graded Materia conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer-in-Charge. With material conforming to Grade-II (size range 53 mm to 0.075 mm ) having CBR Value-25 254 Providing and laying C.C. pavement of mix M-25 with ready mixed concrete from batching plant. The ready mixed concrete shall be laid and finished with screed board vibrator , vacuum dewatering process and finally finished by floating, brooming with wire brush etc. complete as per specifications and directions of Engineer-incharge. (The panel shuttering work shall be paid for separately).(Note:- Cement content considered in this item is @ 330 kg/cum. Excess/ less cement used as per design mix is payable/ recoverable separately). 255 Providing and fixing in position pre-moulded joint filleProviding and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charger in expansion joints. 256 Providing and filling in position rubberized bitumen hot sealingcompound for sealing of expansion joints in roads / pavementsall complete as per direction of the Engineer-in-Charge. 257 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. 258 Construction of granular sub-base by providing close graded Material conforming to specifications, mixing in a mechanical mix plant at OMC, carriage of mixed material by tippers to work site, for all leads & lifts, spreading in uniform layers of specified thickness with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per specifications and directions of Engineer- in-Charge.With material conforming to Grade-I (size range 75 mm to 0.075 mm) having CBR Value-3016.78.1 259 Supply andfixingM.S.Workingate includingall necessary forproper completion of the work. 260 Providing M.S. foot rest including fixing with 20x20x10 cm. cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 gradded aggregate of nominal size 20mm ) as per standard design with 20x20mm sq bars. 261 Providing and fixing C.I. tee at the inlet and outlet of septic tank. 262 Providing & fixing 75mm dia vent pipes.Centrifugally cast (spun) iron socketed pipe asper IS: 3989 263 Providing & fixing of 75mm dia cast iron terminal guard.Sand cast iron S&S as per IS - 3989 264 Providing and fixing in position precast RCC manhole cover and frame of required shape and approved quality.HD . -20- Circular shape 500 mm internal diameter 265 Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks of class designation 75 and S.W. drain pipe 100 mm diameter, 1.8m long complete as per standard design.With F.P.S. bricks 266 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. 300 mm dia all kinds of soil 267 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below ground level. 300 mm dia 268 Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 150 mm nominal size dia 269 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150 mm Nominal Size dia 270 Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading& sizes as per actual requirement, all complete as per direction of Engineer-in-charge. 271 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm Dia 272 Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete.150 mm clamp 273 Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I). 150 mm Dia 274 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. : Internal work - Exposed on wall 50 mm nominal size dia 275 Supply and Installation of 3.0 HP Submersible pump set complete 276 Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/ bore log, including hire & running charges of all equipments, tools, plants & machineries required for the job, all complete as per direction of Engineer -in-charge, upto 90 metre depth below ground level. All types of soil 400 mm dia 277 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well casing(CM) pipe of required dia, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 278 Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, onforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.200 mm nominal size dia 279 Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge. 280 Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-incharge. 281 Supplying, filling, spreading & leveling coarse sand of size range 1.5 mm to 2 mm in recharge pit, in required thickness over gravel layer, for all leads & lifts, all complete as per direction of Engineer -in-charge. 282 Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by “V” notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in pproved laboratory, i/c disinfection of ubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per uirement and direction of Engineer-in-charge. 283 Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 150 mm dia 284 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth upto 1.5 m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50 m:All kinds of soil Pipes, cables etc. exceeding 80 mm dia. but not exceeding 300 mm dia. 285 Providing, laying and jointing P.V.C. pipes including testing of joints etc. complete : 150 mm dia pipe 6 KG/cm^2 286 Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C. top slab with 1:1.5:3mix (1 cement : 1.5 fine sand : 3 graded stone aggregate 20 mm nominal size), foundation concrete 1:5:10 (1 cement : 5 fine sand (Zone III) : 10 graded stone aggregate 40 mm nominal size), inside plastering 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand), finished smooth with a floating coat of neat cement on walls and bed concrete etc. complete as per standard design:Inside dimensions 600x 850 mm and 45 cm deep for pipe line with three or more inlets :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 287 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design :With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 288 Steel work welded in built up sections framed work,including cutting, hoisting ,fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required .in grating ,frames,guard bar,ladder,railings,brackets,gates and similar works. 289 Supply and installation testing and commisioning of IP based EPBX system comprising of core switch & 1.2 switches 16 port EPBAX IP 4 trunk 290 Hand set IP 291 Master handset IP 292 Supplying and drawing of UTP 4 pair CAT 6 Lan cable 293 POE (Power over ethernet) 294 1 kva UPS 295 R1 4510 box with key stone 296 6U rack comrax (45x45x35 cm) DVR 297 PDU (Power distribution unit)) 298 Fan 299 Supply, Installation, Testing & Commissioning of Wireless indoor Access Point Combined data rate support Dual 5GHz 4.8 Gbps, 802.11ax, 2.4 GHz/5GHz: 4x4: 455 WiFi 6, data rate upto 2400 Mpbs. Four 2.4 GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omni Bluetooth Antenna, Transmit Beamforming and Maximal Ratio Combining the WLAN Access Point solution should have Integrtaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and honeypot Access Point detection, able to create WYLAN policies. The solution should be artifical intelligence based self healing soltion. Bluetooth®LE and toTsensor support Humidity pressure (Wi-Fi SYSTEM)Temperature, should also support Asset Tracking if required in future without any change in Hardware. 300 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 301 Supply, Installation, Testing & Commissioning of 03 phase volts 50 cycle per second 1500 RPM air cooled, diesel generating set complete with silent type DG canopy & limiting sound level to 75 dB (A) over a distance of one meter with engine, alternator aircooled. The engine shall be complete with flywheel to suit flexible coupling with guard, air cleaner, fuel pump, fuel day tank, variable speed governor, fuel filter, lube oil filter, battery charging generator, voltage regulator, 24 volt charged voltage regulator, capacity and instrument panel comparing switch with key, space heater, lube oil temperature gauge, lube oil pressure gauge, water temperature gauge, battery charging ammeter, safety control for low lube oil pressure and hightemperaturetripping. The canopy temperature shall not exceed 7 degree above the alternator shall be brushless type excited and self regulated continously rated as follows, 3 phase 415 volts 50cycles, 4 wire system and shall be provided with static excitation unit, alternator insulation shall be class H or better to withstand tropical conditions and shall generally comply with relevant IS and present by-laws under average conditions the voltage regulation shall be within ± 1.5%. The overload capacity shall not be less than 110% for one hour in every 12 hours. The set shall be mounted on a common bed plate with antivibration mounting and alternator shall be suitable for LT AL XLPE cables connection and alternator shall be suitably modified and similarly provision shall be made in the canopy to take out AL XLPE cables DG Set Compatible for synchronising Panel 35 KVA 302 Supplying and laying ofaluminium conductor PVC insulated armoured served sheathed cable 1100 volts grade at the depth of 750 mm bellow ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on side and on top .On surface the cable run shall be fixed on MS clamps etc.of suitable size or as directed bythe Engineer-Incharge ,complete in all respect.The armouring of the cable shall be properly connected with the earth conductor by clamps etc. Following size size 35 sq mm x 3-1/2core 303 Supplying and making cable end terminations with brasscompression gland and aluminium lugs for following size of PVC insulated PVC sheathed/XLPE aluminium conductor cable of 1.1 KV grade, completeas required.3½ X 35 sq. mm (32mm) 304 Supply, Installation, Testing & Commissioning of Armoured 06 Core Singlemode (OS2) 9/125 Fiber Cable, ITU G 652.D, G657A1, Outdoor ECCS Armored Fiber Cable with PBT Loose Tube Filled With Thixotropic Jelly. Uni-Tube, Glass Yarn, Water Swellable Tape Under Armor UV-HDPE Jacket Approved Makes. Derwiser/Nexans Siemen Sistiman 305 Supply, Installation, Testing & Commissioning of 6 Port IU x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummer/Glands to close any open entry, Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices, Tube for open fibers, Thes, Panel shall be Powder Coated with Min 12mm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1, IEC-60754-1. Insertion loss <= 0 35 dB. Return Loss >= 50. Attenuation 1310/1550 10 3/0 2 dB/KM. Repeatability <= 02DB 1000 Tunes Mating Cycles, RoHS Complied. Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 306 Supply. Installation, Testing & Commissioning of 24 Port 10 x 19 LIU Loaded with Singlemode 052 LC Adapters & LSZH Pigtails along with Splice Trays, Min 4 No of Circular Cable Entry with Rubber Groummet Glands to close any open entry. Cable Holders for Cable Entry Inside Panel, Heat Shrink Tubes for Splices. Tube for open fibers. Ties, Panel shall be Powder Coated with Min | 2trm Metal Sheath, 30 Years Channel Warranty Factory Loaded LC Type LSZH Pigtails should meet IEC 61034-1 IEC-60332-1. IEC-60754-1, Insertion loss <= 0 35 dB, Return Loss >= 50. Attenuation 1310/1550 03/02 dB/KM. Repeatability <= 0 2DB 1000 Times Mating Cycles, RoHS Complied, Meets ANSI/TIA 568 3-D Approved Makes Derwiser/Nexans/Stemon/Systimax 307 Supply. Installation, Testing & Commissioning of fiber patch cord. LC-LC Spiral steel armored 9/125mm OS2 singlemode round cord (4.0 +/- 0.mm).Duplex approved makes Derwiser/Nexans/Stemon/Systimax 308 Supply. Installation, Testing & Commissioning of Cat 6A, 23 AWG (0 57.003mm) Bare Copper Solid Conductor UTP Unshielded LSZH Jacket, ANSI/TIA 568 C2 Category 6A, Cable shall not have any kind of Non Metallic Barrier Tape or Metallic Shield inside. Connectivity of Hub room to End Point Approved Makkes Derviser/Nexans/Stemon/Systimax 309 Supply, Installation, Testing & Commissioning of Category 6A RJ45 Unshielded Modular Jack. ISO/IEC 11801 2nd edition, EN 50173-1, ANSI/TIA/EIA 568-C 2 Category 6A, IEC 60603-7 (603-7). Universal 110 Impact Tool & Tooless (Both) Termination, Min 500Mhz Bandwidth, Without Any OEM Proprietary Tool Termination for Data, Voice, & Wi-Fi at user end Approved Makes Derwiser Nexans Siemon Systimax 310 Supply, Installation. Testing & Commissioning of loaded 24 port CAT 6A UTP. Transparent shutter ack panel, IU height, UL-94V-0, cicar label marks and earthing plug for CAT6A cable termination at rack end No Approved Makes Derwiser Nexans Siemon Systimax 311 Supply, Installation. Testing & Commissioning of Cat6A Putch Cord [TP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm. 1 Meter. Operating Temperature -20 to +60 Deg C Patch cord | Mtr for rack side swatch to jack panel connectivity Approved Makes. Derwiser/Nexans/Stemon/Systimax 312 Supply, Installation, Testing & Commissioning of Cat6A Patch Cord UTP Unshielded LSZH 24AWG Patch Cord, Diameter < 62mm, 3 Meter. Operating Temperature -20 to +60 Deg C Patch cord 2 Mtr for rack side switch to end user connectivity Approved Makes Derwiser Nexans/Siemon/Systimax 313 Supply, Installation, Testing & Commissioning of 1, 2 and 4 port Style (Square) Keystone TypeShuttered Faceplates for 1/0 fixing at user side Approved Makes Derwiser/Nexans Stemon/Systimax 314 Supply, Installation, Testing & Commissioning of 42 U (600W/1000D) floor mount rack with fans, 2 cable managers, salationary shelf, 2 Nos of hardware pkts Approved Makes Derwiser MIS Rata/APC/APW 315 Supply, Installation, Testing & Commissioning of 22 U floor mount rack with fans. 2 cable managers satationary shelf. 2 Nos of hardware pkts Approved Makes Derwiser/MTS/Rital/APC/APW 316 Supply, Installation. Testing & Commissioning of 15t/ wall mount rack with fans, 2 cable managers. satationary shelf. 2 Nos of hardware pkts Approved Makes Der Wiser/MIS/Rittal/APC/APW 317 Supply, Installation, Testing & Commissioning of Core Switch with switching capacity of 12 Tbps, forwarding performance of 1000 Mpps with 24x 1/10G SFP+ ports expandable to 40 SFP+ ports with 4x 40G QSFP+ ports from day 1, dual hot swappable internal power supply, Stacking/Virtual Chasis support upto 9 Switches with bandwidth 140 Gbps, 64K IPv4 and IPv6 Routes and 30K multicast routes MAC Address 250K, Jumbo frame 9000 bytes should support Routing protocols (KIPng OSPF v3, IS-IS v6, BGPv6) with 1 year support Should be Common Criteria/NDPP/NDCPP certified & IPv6 Logo Certified OEM should be Leader in Forrestor SDN & Gartner Data Centre latest report Approved make - Cisco / Juniper / Impulse / Nexxus/Arista 318 Supply, Installation, Testing & Commissioning of 12 Port POE+ Access Switches with switching capaticy of 200 Gbps, forwarding performance 150 Mpps, having 24 x 10/100/1000BASE-1 Pol-plus(RJ45) with minimum PoE budget of 370 W, with 4 x 10G SFP+ uplink ports Should support min 4GB internal DRAM, 8GB internal Flash memory, 64K MAC address Should have Static Routing. Neighbor discovery, system logging. Telnet, SSII, SNMP, Network Tune Protocol (NTP), Domain Name System (DNS) and IPv6 features from day I and should support OSIF, VRRP, OSPFv3 and PIM Approved make - Cisco/Juniper / Impulse/Nexxus/Arista 319 Supply, Installation. Testing & Commissioning of fiber Modules 10G BASE Approved Make Cisco/Juniper / Impulse/Nexxus/Ariste 320 Supply. Installation, Testing & Commissioning of Wireless Indoor Access Point Combined data rate support Dual SGHz 4.8Gbps, 8021lax, 24 GHz/5GHz 4x4 4SS WiFi 6, data rate upto 2400 Mpbs. Four 2.4GHz omnidirectional antennas with 4 dBi peak gain, Four 5GHz omnidirectional antennas with 6 dBi peak gain, vBLE 16-element Directional Antenna Array Omn: Bluetooth Antenna Transmit Beamforming and Maxımal Ratio Combining the WLAN Access Point solution should have integriaed dynamic packet capture, WIPS, Dedicated Third Radio, detection of rougue and 1 honeypot Access Point detection, able to create WxLAN policies The solution should be artifical intelligence based self healing soltion Bluetooth LE and loTsensor support Humidity Pressure Temperature, should also support Asset Tracking if required in future without any change in Hardware Omni-directional Bluetooth Antenna, superbeacon mode with iBeacon and Eddystone, OFDMA & BSS Coloring support Operating temp 0 to 40 degree. Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse/Nexxus/Arista 321 Supplying Installation Testing & Commissioning of Wifi & Dual Band Ax 1800 (WAVE2, MU MIMO, 802 11AX (2x2)) with 2 5 Gbps Poe+ Port Mesh Access Point as required at site. Approved Make Cisco/Juniper / Impulse/Nexxus/Arista/Netgear 322 Supply. Installation, Testing & Commissioning of Wireless Controller Should be Artificial Intelligence (AI) driven Microservices based architecture. The Solution should support 802.11ac primarily and should be backward compatible to 802 | In/a/b/g The solution should also support 802 | lax with Guest Portal support, support WIPS, Rouge AP detection and Honeypot AP detection, able to provide insights based on Time to connect, successful connect, coverage, capacity, AP Uptime, Roaming and throughput able to integrate with varous authentication mechanism including the RADIUS servers, able to handle interference and shift the communication on another channel automatically if, needed, support Dynamic Packet capture to enhance troubleshooting Microservice based Architecture should be scalable to handle around 5000 APs or more in future, Should have a virtual assistant to troubleshoot deeper and facilitate investigation of existing or future issues in the Wi-Fi network Artificial Intelligence feature should be manageble from Wireless to Switching devices Wireless OEM should be leader in Gartner Wired Wireless & Data Centre latest reports Approved Make Cisco/Juniper / Impulse / Nexxus/Arista 323 Providing and fixing T-iron frames for doors,windows and ventilators of mild steel Tee-sections,joints mitered and welded with15*3mmlugs 10 cmlong embededded in cement concreteblocks 15*10*10cmof 1:3:6 ( 1 cement : 3 course sand :6 graded stone aggregate 20 mm nominal size ) orwithwooden plugs and screwsor rawlplugsand screws or with fixing clipsorwith bolts and nutsas require including fixing ofnecessarybut hingesand screws and applying a priming coat of approved steel primer. 324 ANGLE IRON90*90*6 mm 325 T-SECTION 90*90*6 326 HOLD FAST40*6 FLAT 327 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. G.I. Pipe(80 MM DIA)

Key Value

Document Fees
INR 5310 /-
EMD
INR 570000.0 /-
Tender Value
INR 2.85 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail