}

Temporary Electrical Installation And Working Light In Connection With Durga Puja Co Ordination Meeting 2025 Under Mesd, Pwd., kolkata-West Bengal

Public Works Department has published Temporary Electrical Installation And Working Light In Connection With Durga Puja Co Ordination Meeting 2025 Under Mesd, Pwd.. Submission Date for this Tender is 28-07-2025. LED Light Tenders in kolkata West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50183587
Temporary Electrical Installation And Working Light In Connection With Durga Puja Co Ordination Meeting 2025 Under Mesd, Pwd.
Tender
Indian
West Bengal
Kolkata
28-07-2025

Tender Documents

Tender Details

Temporary Electrical Installation And Working Light In Connection With Durga Puja Co Ordination Meeting 2025 Under Mesd, Pwd.- 1 Supply and drawing of the following sizes pvc insulated and unsheathed multistranded copper wire on hire basiswith carrying cost at the sites and dismantling as per direction of EIC including socketing,glanding and necessary finishing as required for 2 days 2 7/0.036 Sqmm Single Core Copper Wire 3 3/0.029Sqmm Single Core Copper Wire 4 Supply and drawing of the following sizes pvc insulated and unsheathed multicore aluminium armoured cable on hire basiswith carrying cost at the sites and dismantling as per direction of EIC including socketing,glanding and necessary finishing as required for 2 days 5 4CX35 sq mm cable 6 4C X 25 Sqmmcable 7 4CX16 sq mm 8 Providing and installation on Hire basis 500VTPN MS with rewirable fuse/HRC fusefixed on angle iron frame incl providing necy inter connection wiring, 2 nosof earthing with earthing attachment and dismantling as directed by EIC after the programme (for 2 days) 9 415V, 32 A 10 415V, 63A 11 Providing and installation on hire basis power BDB/TPNMCBDB 440V , 100/125Amp 4 Pole MCB isolator as incomer with 32Amp or 64 Amp per way(min 4 Way) out going connection, with all arrangement in a outdoor type pillar box incl interconnection with proper socketing and dismantling as direcyted by EIC after the programme (for two days) 12 Providing and installation on hire basis 500 V, 63Amp/32Amp 4 Pole MCB fixed on sheet metal box with proper socketing and dismantling as direcyted by EIC after the programme (for two days) 13 Providing and Fixing on hire basisfollowing LED Flood lightfittings complete with all accessories(like Clamps, nuts and bolts as required) and dismantling as directed by EIC after the programme (for 2 days) 14 Minimum 200 Watt LED Flood fittings. 15 Providing on hire basis 5A/15A plug socket complete with necy wiring in 3 x 1.5 sq.mm single core copper wire and dismantling as directed by EIC after the programme (Avg Run- 3mtr ) 16 Providing on hire basis 600 mm sweep Air Circulator Fan complete incl. transportation, loading unloading and dismantling after programme as per direction of EIC (2 days) 17 Maintenance, operation and Guarding arrangement of the installation of temporary lighting round the clock by 3 skilled labour& 3 helper per day throughout the period. (1 skilled labour and 1 helper per shift) 18 Transportation charge for the materials from Companys godown to Site and return back to godown after use. 19 Special Terms and conditions for Temporary E.I. Work 1) Earthing should conform to IS specification. Earth Continuity wire should not be broken / Jointed. Single Earth continuity wire should be used from Earth Bus-Bar to the installation.2) Main Electrical Panel Should be earthed by two nos. of separate earthing.3) MCB / Rewirable Fuse type Distrubution Board should be installed with proper Trip Current setting / fuse wires. However, MCB type DBs are preferable.4) No Part of the Electrical Circuit in the pandal / Structure shall be within 12 inches of any decorative cloth / paper.5) Ordinary Flexible wires should not be used. Only new PVC insulated & sheathed wires (Bearing ISI mark) or PVC insulated wires of FRLS (Fire Resistant Low Smoke) type (ISI Marked) are allowed.6) All cable ends should be properly sockedted.7) All joints shall be made with porcelain insulated connectors. Twisted & lapped joints shall be avoide. But Joints are strictly not allowed in the dias.8) Cables / Wires should run along outside the Dias.9) Ceiling fan (s) / Electrical fittings must not be suspended from the ceiling of Dias. Pedestal fans are not allowed on the Dias. However, Pedestal fans may be installed outside dias, but the body of the fan must be properly earthed. 20 10) T/L fittings shall be of box type (Indoor commercial type). Any kind of open type fittings must be avoided.11) Each A.C. Machine should be connected with a separate circuit and earthing should be provided by separate single earth contunuity wire from Earth Bus-bar.12) P.A. System and Microphone shoud be earthed.13) Sufficient quantity of Fire Extinguishers and First Aid Box should be provided.14) If the DGs are not placed at site on time pro rata rate will be reduced from bill.15) No additional charges will be paid for any unwanted incidents like theft, willfull damage etc.

Key Value

Document Fees
Refer document
EMD
INR 10000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail