Tender For Additional Lighting System & Miscellaneous Electrical Works In Main Plant Area For Rapp-8.; 1 Supply & Installation of 25mm GI conduitincluding supply & installation of all accessories like bends, elbows, couplers, flexible conduits, hospital saddles, spacers , Lead Sleeves &Screwsetc., and other accessories required to complete the job on wall/ column/ ceiling etc. as per specification and drawings. (The running length shall be measured along the centre line including bends, fittings etc. along the run installed, but excluding the hidden length of conduits and lengths of pull boxes and junction boxes)Note:TheInstallation chargequotedshallincludesupplyofaccessorieslikebends, flexible conduits, elbows, couplers, hospital saddles, spacers,Lead Sleeves & Screws etc. 2 Supply of 25mm GI conduit 3 Installation of 25mm GI conduit 4 Supply & Installation/ termination/ connection of 4.0Sq.mm copper wire including Lugs and Ferrules etc. Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 5 Supply of 4sqmm copper wire 6 Installtion of 4sqmm copper wire 7 Supply & Installation,termination,connection of 14 SWG GI grounding wire including supply and installation of copper clamps, connection to earthing terminals, Junction boxes, pull boxes etc., as per technical specification and drawings. Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 8 Supply of 14SWG GI WIRE 9 Installation of 14SWG GI WIRE 10 Supply & Installation of 5A, Decorative type lighting control switch lighting control switchfor lighting system including supply and installation of screw with necessary drilling etc. as required.Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 11 Supply of 5A Lighting control switch 12 Installation of 5A Lighting control switch 13 Supply & Installation of following types ofjunction boxesfor25mm GI conduit in Lighting/ receptacle/ space heating system including supply and installation of anchor fasteners, mounting brackets, support structure, hardware etc. (wherever required) along with necessary welding, drilling, painting etc. Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 14 Supply of Junction Box 15 Installation of Junction Box 16 Supply of Pendant mounted batten type 40W LED luminaires with extruded aluminium housing or equivalent, suitable diffuser, suitable driver, complying with all relevant standards. Minimum lumen output - 4800 lumens. Type-BNote: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 17 Supply of 40W LED Luminaire 18 Installation of 40W LED Luminaire 19 Supply & Installation of Batten type 40W LED luminaires with PC housing with base of extruded aluminium or equivalent, suitable diffuser, suitable driver, complying with all relevant standards. It shall be of dustproof type and shall be provided with suitable arrangements for surface and suspension mounting. Minimum lumen output - 4800 lumens. TYPE-DNote: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 20 Supply of 40W LED Luminaire 21 Installation of 40W LED Luminaire 22 Supply & Installation of 36W LED recessed mounted decorative luminaires with CRCA housing or equivalent, suitable diffuser, suitable driver, complying with all relevant standards. Minimum lumen output - 3600 lumens. The dimension of fixtures shall be 2x2 feet approximately. TPYE-ENote: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 23 Supply of 36W LED Luminaire 24 Installation of 36W LED Luminaire 25 Supply & Installation of 80W LED low bay luminaires with pressure die cast aluminium housing or equivalent, suitable diffuser, suitable driver, complying with all relevant standards. It shall be provided with suitable surface and suspension mounting arrangements. Minimum lumen output - 9600 lumens. TYPE-H3.Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 26 Supply of 80 LED Luminaire 27 Installation of 80 LED Luminaire 28 Supply & Installation of 6ACRCA sheet steel receptacle shall be industrial type, IP-42, 3 pin , single phase, 50Hz, 240V AC supply.All receptacles shall be supplied with MCB and plug tops as per relevant IS.Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 29 Supply of 6A Receptacle 30 Installation of 6A Receptacle 31 Supply & Installation of 16ACRCA sheet steel receptacle shall be industrial type, IP-42, 3 pin , single phase, 50Hz, 240V AC supply.All receptacles shall be supplied with MCB and plug tops as per relevant IS.Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 32 Supply of 16A Receptacle 33 Installation of 16A Receptacle 34 Supply & Installation of 63ACRCA sheet steel receptacle shall be industrial type, IP-42, 4 pin & neutral, 3 phase, 50Hz, 415V AC supply. All receptacles shall be supplied with MCB and plug tops as per relevant IS.Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 35 Supply of 63A Receptacle 36 Installation of 63A Receptacle 37 Installation of ELB , Site Installation works (Erection, preparation of area/ EP where the equipment is to be installed, installation, carrying out pre-commissioning checks, Testing and commissioning includingstorage, handling, loading/unloading, transportation at site,etc. and handing over offollowing Electrical Equipments including supply and installation of Embedded parts (wherever required), anchor fasteners, base frames, mounting brackets, support structures, hardware etc. (as required) along with necessary welding drilling, painting etc. of different modules conforming to requirement of tender specification and GA drawings.Note: The Installation charges quoted shall include supply of all accessories and hardware mentioned above. 38 Dismantalling , loading, transportation, unloading andRe-Installation ofStructural steel High Mastlighting tower of30 Mtr. height . Average transportation distance from existing location to designated location isapproximately1500 M at main plant area of RAPP-7&8. The scope alsoincludes Re-installation of HPSV/LEDlighting fixturecomplete with all accessoriesOther detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 39 Dismantalling of High MastTower from Existing Foundation 40 Loading, Shifting and unloading ofHigh Mast Tower 41 Re-Installation ofHigh MastTower onfoundation 42 Supply & Installation of photo cell unit: Supply & installation of photo cell unitwith 3 Phase 04 wire 32 amp power contactor unit panelfor lighting control. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 43 Supply: 44 Installation: 45 Installation,Termination & Connection of2Cx 2.5 mm2 Copper Conductor control cableforlighting control. Other detailsare as per Technicalspecification and direction of Engineer-In-Charge . 46 Laying of Cable : 47 Glanding, Termination & Connection: 48 Laying of Cable 4C X 25 sq mm cable:Laying of 1100 V gradestranded shaped AL conductor XLPEinsulation extruded, PVC inner Sheathed, GS Strip/Wire armoured and overall PVCsheathedcablein trenches /burried in ground. .The cable shall be supplied by NPCIL on free issue basis. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 49 Supply , Glanding, Termination and Connection of cable gland (Including Lugs): Supply , Glanding, Termination & Connection of1100 V gradeXLPEinsulated armoured aluminium cable, including supplyand installation of Double compression nickle plated brasscable glands and crimping type aluminium lugsas per Specification . The Rate quoted shall be inclusive of cost of double compression cable gland & aluminium lugs. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 50 Supply of Cable Gland with Lug for4CX25 sq mmCable 51 Glanding, Termination and Connection of 4CX25 sq mm Cable (with Lugs) 52 Supply, Installation ,Termination & Connection of1.1 KVvoltage grade 5C *2.5mm2 EPR insulated PCP sheathed trailing cable for high mast tower. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 53 Supply of Cable: 54 Laying of Cable : 55 Termination & Connection: 56 Supply and Installation of 8 SWG GI wire:Supply and Installation of 8 SWG GI wire for Equipment earthing along with cable/conduit. The scope includessupply and installation of all hardware and consumables required for successfully completion of the job. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 57 Supply of 8 SWG GI wire: 58 Installation of 8 SWG GI wire: 59 Supply and Replacement of lighting fixtures (70W HPSV Bulkhead) : Supply and replacement of lighting fixtures of 70W HPSV Bulkhead with LED lighting fixtures in Turbine Building (approax height of fixture is 3-4mtrs) including replacement of wire (approx 1.5mtr), flexible conduit (approx 1.5mtr), lug along with their termination. Other detailsare as per Technicalspecification and direction of Engineer-In-Charge. 60 Supply of LED lighting fixture : LED bulkhead luminaires with die cast aluminium housing or equivalent, suitable diffuser, suitable driver, suitable for wall mounting arrangement, complying with all relevant standards. Minimum lumen output 6600 lumens 61 Replacement of lighting fixtures as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 62 Supply and Replacement of lighting fixtures (70W HPSV Well Glass) : Supply and replacement of lighting fixtures of 70W HPSV Well Glass with LED lighting fixtures in Turbine Building (approax height of fixture is 3-4mtrs) including replacement of wire(approx 1.5mtr), flexible conduit (approx 1.5mtr), lug along with their termination. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 63 Supply of LED lighting fixture : LED well glass luminaires with pressure die cast aluminium housing or equivalent, suitable diffuser, suitable driver, complying with all relevant standards. Minimum lumen output - 6600 lumens 64 Replacement of lighting fixtures as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 65 Supply and Replacement of lighting fixtures (160W MLL lamp) : Supply and replacement of lighting fixtures of 160W MLL lamp with LED lighting fixtures in Turbine Building (approax height of fixture is 3-4mtrs) including replacement of wire(approx 1.5mtr), flexible conduit (approx 1.5mtr), lug along with their termination. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 66 Supply of LED lighting fixture :LED flameproof fixtures with Ex’d’ type enclosure suitable for gas group IIA & IIB, cast aluminium housing or equivalent, diffuser of toughened glass, corrosion resistant finish, suitable driver, complying with all relevant standards. Cable entry for the fixtures shall be provided with flame proof cable glands suitable for termination of 3core 1100V grade 2.5mm2 copper XLPE insulated armoured cables. For plugging off unused entries flame proof plugs shall be used. Minimum lumen output 12600 lumens. 67 Replacement of lighting fixtures as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 68 Supply and Replacement of lighting fixtures (150W HPSV lamp): Replacement of 150W HPSV lamp lighting fixtureswith LED lighting fixturesin Turbine Building ( approx height of fixture is 6-7 mtrs) including replacement of wire(approx 1.5mtr), flexible conduit (approx 1.5mtr), lug along with their termination. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 69 Supply of LED lighting fixture : LED medium bay luminaires with pressure die cast aluminium housing or equivalent, suitable diffuser, suitable driver, suitable surface and suspension mounting arrangements, complying with all relevant standards. Minimum lumen output 27000 lumens 70 Replacement of lighting fixtures 71 Supply and Replacement of lighting fixtures (250 W HPSV lamp) : Replacement of 250 W HPSV lamp lighting fixtureswith LED lighting fixturesin Turbine Building (approax height of fixture is 10-11mtrs) including replacement of wire (approx 1.5mtr), flexible conduit (approx 1.5mtr), lug along with their termination. Other detailsare as per Technicalspecification and direction of Engineer-In-Charge. 72 Supply of LED lighting fixture : LED floodlight luminaires with pressure die cast aluminium housing or equivalent, diffuser of toughened glass, suitable driver, complying with all relevant standards. Minimum lumen output 28200 lumens. 73 Replacement of lighting fixtures 74 Supply and Replacement of lighting fixtures (400 W HPSV lamp) : Replacement of 400 W HPSV lamp lighting fixtureswith LED lighting fixtures in Turbine Building at roof trust including replacement of wire (approx 1.5mtr), flexible conduit (approx 1.5mtr), lug along with their termination. Other detailsare as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative. 75 Supply of LED lighting fixture : LED high bay luminaires with pressure die cast aluminium housing or equivalent, suitable diffuser, suitable driver, suitable surface and suspension mounting arrangements, complying with all relevant standards. Minimum lumen output 47000 lumens 76 Replacement of lighting fixtures as per Technicalspecification and as per direction of Engineer-In-Charge or his authorized representative.