Tender For Rdss Ed-Udhampur--Plant And Equipment Supply Including Inland Transportation And Other Services-1 8 Mtr. Long Pole (ST-410 SP15) 2 9 Mtr. Long Pole( ST-410 SP33) 3 9 Mtr. Long RS Joist Pole(152x152) 4 11 Mtr. Long Pole(ST-410 SP56) 5 30 mm² ACSR Conductor 6 100 mm² ACSR Conductor - Dog 7 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 8 63 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 9 100 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 10 400 kVA (11/0.433-0.250KV;50Hz), Copper Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 11 630 kVA (11/0.433-0.250KV;50Hz), Copper Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 12 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (Compatible with existing VCB at 33/11 KV Sub-station ) 13 11KV Adaptor Panel (if required) 14 12 kV 3.6 MVAR Capacitor Bank with VCB Panel with complete arrangement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 15 11kV, Three core 185 mm2 Aluminium roundwire/flat Armoured XLPE Cable , FRLS ( one spare cable) 16 11kV, Three core 120 mm2 Aluminium roundwire/ flat Armoured XLPE Cable , FRLS ( one spare cable) 17 120 mm² AB (HT) Cable ( 3 x 120 + 1 x 95 mm²) 18 95 mm² AB (HT) Cable (3x95+1x70 mm²) 19 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 70 mm²) 20 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) 21 300 mm² Single Phase Cable,1.1KV Grade, Unarmoured PVC Insulated Stranded Conductor FRLS type 22 240 mm² Single Phase Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type 23 70 mm² Single Phase Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type 24 25 mm² Single-Core Cable,1.1kV Grade, PVC InsulatedStranded Conductor FRLS type 25 Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymerhousing 26 11 kV Horn Gap Fuse Set 3-Phase 200A 27 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 28 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting 29 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance320mm 30 16kN Shackle Insulators with fitting 31 Aluminium Jointing Sleeves 32 Aluminium Paint 33 Anti-Climbing Device with Clamps 34 Cable Termination Kits (indoor/outdoor) for 11KV 3Cx120 sqmm XLPE 35 Cable Termination Kits (indoor/outdoor) for 11KV 3Cx185 sqmm XLPE 36 Danger Plates with Clamps 37 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 38 Galvanized Nuts and Bolts 39 GI Channel X-arm including clamps and braces 40 GI Channel/Angle/Flat of sizes including clamps 41 GI Pipe 150 mm dia 42 GI Rod 20mm 2.5 mtr long through GI Strip. 43 GI U-Clamps for Shackle Insulators 44 GI V cross-arm with top Bracket including clamp 45 Guard netting 46 Heat Shrinkable Outdoor Cable Termination Kit (95 sqmm HT AB) 47 Heat Shrinkable Outdoor Cable Termination Kit (120 sqmm HT AB) 48 Insulating Piercing Connetors 49 LT Distribution Box for 100 kVA DTR with MCCB forincomer & Outgoing Circuits 50 LT Distribution Box for 400 kVA DTR with MCCB forincomer & Outgoing Circuits 51 LT Distribution Box for 63 kVA DTR with MCCB forincomer & Outgoing Circuits 52 LT Distribution Box for 630 kVA DTR with MCCB (As per Technical Specification) 53 LT Line Spacers 54 LT 3 Phase Distribution Box (Metallic) with Busbar for service connection including GI clamps ( Pole mounted) 55 LT Single Phase Distribution Box (Metallic) with Busbar for service connection including GI clamps ( Pole mounted) 56 Mid Span Straight Throgh Jointing Kit for 11 kV ABC (120 sqmm) 57 Painting/Hardware & Support with numbering of pole - For RS Joist Pole 58 PG Clamps 59 PG Clamps for 100 mm² ACSR Conductor 60 Red Oxide Paint 61 Cable route marker 62 Straight Through Cable Jointing Kit for 120 mm2 LT AB cable 63 Straight Through Cable Jointing Kit for 70 mm2 LT AB cable 64 Straight Through Joints for cables (11kV 3Cx120 sqmm) 65 Straight Through Joints for cables (11 KV 3Cx185 sqmm) 66 Strain Hardware 67 Sundry items like aluminium lugs, Jumpers, binding Tape 68 Suspension/Tension Clamp with eye hook 69 Transformer Bed 70 warning Tape 71 Wedge Connectors / PG Clamps 72 Sign Board 73 4Cx35 sqmm PVC cable from AB Cabling tapping to three phase Pole DB 74 2Cx25 sqmm PVC cable from AB Cabling tapping to single phase Pole DB 75 HDPE Pipe (150 mm Diameter) 1 8 Mtr. Long Pole (ST-410 SP15) 2 9 Mtr. Long Pole( ST-410 SP33) 3 9 Mtr. Long RS Joist Pole(152x152) 4 11 Mtr. Long Pole(ST-410 SP56) 5 30 mm² ACSR Conductor 6 100 mm² ACSR Conductor - Dog 7 25 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 8 63 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 9 100 kVA (11/0.433-0.250KV;50Hz), Aluminium Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 10 400 kVA (11/0.433-0.250KV;50Hz), Copper Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 11 630 kVA (11/0.433-0.250KV;50Hz), Copper Wound Distribution Transformer of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment 12 11 kV VCB Panel Board (12 kV, 1250A, 25 kA, indoor) with O/C, E/F relays (IEC61850), Mimic Diagram, Voltmeter, Ammeter, Annunciation Windows with annunciation relays, 3-phase Tri-vector meter -5 Amps, DLMS Compliant with RS-485 port (Compatible with existing VCB at 33/11 KV Sub-station ) 13 11KV Adaptor Panel (if required) 14 12 kV 3.6 MVAR Capacitor Bank with VCB Panel with complete arrangement for conection with 11 kV incomer panel , Series Reactor, Isolator, RVT, Surge Arrestors, HT Cable with termination Kits, Control Cables, CRCA Cubicle Panel etc with structure, foundation & accessories. 15 11kV, Three core 185 mm2 Aluminium roundwire/flat Armoured XLPE Cable , FRLS ( one spare cable) 16 11kV, Three core 120 mm2 Aluminium roundwire/ flat Armoured XLPE Cable , FRLS ( one spare cable) 17 120 mm² AB (HT) Cable ( 3 x 120 + 1 x 95 mm²) 18 95 mm² AB (HT) Cable (3x95+1x70 mm²) 19 120 mm² AB (LT) Cable ( 3 x 120 + 1 x 70 mm²) 20 70 mm² AB (LT) Cable ( 3 x 70 + 1 x 16 + 1 x 50 mm²) 21 300 mm² Single Phase Cable,1.1KV Grade, Unarmoured PVC Insulated Stranded Conductor FRLS type 22 240 mm² Single Phase Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type 23 70 mm² Single Phase Cable,1.1KV Grade, PVC Insulated Stranded Conductor FRLS type 24 25 mm² Single-Core Cable,1.1kV Grade, PVC InsulatedStranded Conductor FRLS type 25 Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymerhousing 26 11 kV Horn Gap Fuse Set 3-Phase 200A 27 11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp 28 11kV Polymeric composite Disc Insulator 12kV,minfailing load 45kN, Lightening Impulse 75kV Positive and 80kV Negative, creepage distance 320mm with fitting 29 11kV Polymeric composite Pin Insulator 12kV, 5kN, Lighting Impulse 75kV Positive and 80kV Negative, creepage distance320mm 30 16kN Shackle Insulators with fitting 31 Aluminium Jointing Sleeves 32 Aluminium Paint 33 Anti-Climbing Device with Clamps 34 Cable Termination Kits (indoor/outdoor) for 11KV 3Cx120 sqmm XLPE 35 Cable Termination Kits (indoor/outdoor) for 11KV 3Cx185 sqmm XLPE 36 Danger Plates with Clamps 37 Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for connection of transformer body,G.O Set & lightening arrestor as per IS 2629/85, GI nuts & bolts,refilled with earth enhancement materials and earth Chamber made of brick masonary with RCC slab cover. 38 Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete 39 Galvanized Nuts and Bolts 40 GI Channel X-arm including clamps and braces 41 GI Channel/Angle/Flat of sizes including clamps 42 GI Pipe 150 mm dia 43 GI Rod 20mm 2.5 mtr long through GI Strip. 44 GI U-Clamps for Shackle Insulators 45 GI V cross-arm with top Bracket including clamp 46 Guard netting 47 Heat Shrinkable Outdoor Cable Termination Kit (95 sqmm HT AB) 48 Heat Shrinkable Outdoor Cable Termination Kit (120 sqmm HT AB) 49 Insulating Piercing Connetors 50 LT Distribution Box for 100 kVA DTR with MCCB forincomer & Outgoing Circuits 51 LT Distribution Box for 400 kVA DTR with MCCB forincomer & Outgoing Circuits 52 LT Distribution Box for 63 kVA DTR with MCCB forincomer & Outgoing Circuits 53 LT Distribution Box for 630 kVA DTR with MCCB (As per Technical Specification) 54 LT Line Spacers 55 LT 3 Phase Distribution Box (Metallic) with Busbar for service connection including GI clamps ( Pole mounted) 56 LT Single Phase Distribution Box (Metallic) with Busbar for service connection including GI clamps ( Pole mounted) 57 Mid Span Straight Throgh Jointing Kit for 11 kV ABC (120 sqmm) 58 Painting/Hardware & Support with numbering of pole - For RS Joist Pole 59 PG Clamps 60 PG Clamps for 100 mm² ACSR Conductor 61 Red Oxide Paint 62 Cable route marker 63 Straight Through Cable Jointing Kit for 120 mm2 LT AB cable 64 Straight Through Cable Jointing Kit for 70 mm2 LT AB cable 65 Straight Through Joints for cables (11kV 3Cx120 sqmm) 66 Straight Through Joints for cables (11 KV 3Cx185 sqmm) 67 Strain Hardware 68 Sundry items like aluminium lugs, Jumpers, binding Tape 69 Suspension/Tension Clamp with eye hook 70 Transformer Bed 71 warning Tape 72 Wedge Connectors / PG Clamps 73 Sign Board 74 4Cx35 sqmm PVC cable from AB Cabling tapping to three phase Pole DB 75 2Cx25 sqmm PVC cable from AB Cabling tapping to single phase Pole DB 76 HDPE Pipe (150 mm Diameter) 77 RCC (1:2:4) Platform of size (8 ftx8 ftx 6ft) with all associted materials for 400 KVA DTR 78 Cement bottoming 1:2:4 mix as per REC standards 0.45cum /pole 79 Cement bottoming 1:2:4 mix as per REC standards0.5cum /pole 80 Cement bottoming 1:2:4 mix as per REC standards 0.6cum/pole 81 Brick Masonary Chamber 900x900x1050mm with RCC top slab, Cast Iron cover in CI Frame (38Kg) for laying underground cable 82 Reinstatement of roads (100 m x .7 m x 0.2 m thick) = 14 cums for laying underground cable 83 Mechanical transport beyond 20kms of sand for laying of underground cable in open trench method 84 Head load beyond 100 mtrs of sand for open trench method 85 Excavation in any type of soil including backfilling, laying of bricks and sand bedding for open trench method 86 Extension of substation control room building (if required) to provide additional space for new outgoing feeder panel/s. This includes all civil, electrical and associated works. Each extension shall be approximately 36 sqm (6x6 m). 87 Cable Laying through HDD method in any type of soil 88 RCC protective cover of size 300 mm (width) x 300mm (Length) x 60 mm (Thickness) in open trench method for laying underground cable