}

Tender For Comprehensive Operations And Maintenance In Respect Of Civil, E&M And Horticulture Works For Aiims Vijaypur, Jammu, Campus For 2 Years, vijaypur-Jammu And Kashmir

All India Institute Of Medical Sciences has published Tender For Comprehensive Operations And Maintenance In Respect Of Civil, E&M And Horticulture Works For Aiims Vijaypur, Jammu, Campus For 2 Years. Submission Date for this Tender is 28-07-2025. Horticulture Tenders in vijaypur Jammu And Kashmir. Bidders can get complete Tender details and download the document.




Tender Notice

50179117
Tender For Comprehensive Operations And Maintenance In Respect Of Civil, E&M And Horticulture Works For Aiims Vijaypur, Jammu, Campus For 2 Years
Tender
Indian
Jammu And Kashmir
Vijaypur
28-07-2025

Tender Documents

Tender Details

Tender For Comprehensive Operations And Maintenance In Respect Of Civil, E&M And Horticulture Works For Aiims Vijaypur, Jammu, Campus For 2 Years; 1 Providingservices for attending complaints of day to day maintenance carrying outcarpentryworksuchasrepairingof wooden/aluminiumdoor,window,ventilator, partitions etc. and othermisellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM). Carpenters (05 Nos Per day) 2 Providingservices for attending complaints of day to day maintenance carrying outmasonryworkand other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM).Masons (06 Nos Per day) 3 Providingservices for attending complaints of day to day maintenance carrying outplumbing work and other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM).Plumbers all working days between 9 AM to 5 PM (05 Nos Per day) 4 Providingservices for attending complaints of day to day maintenance carrying outplumbingwork and other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 5 PM to 9 AM).Plumbersfor Night Duty(02 Nos Per day) 5 Providingservices for attending complaints of day to day maintenance carrying outsewagework and other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM).All working days between 9 AM to 5 PM(04 Nos Per day) -- Sewermans(Semi Skilled) 6 Providingservices for attending complaints of day to day maintenance carrying outsewagework and other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 5 PM to 9 AM) - Sewermans(Semi Skilled)For Night Duty (02 Nos Per day) 7 Providingservices for attending complaints of day to day maintenance carrying outlabourwork and other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM).Beldars (20 Nos Per day) 8 Providingservices for attending complaints of day to day maintenance carrying outcarpentrywork and other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM).-Sweepers (20 Nos Per day) 9 Making arrangement for up keep & running of service centre (24 hours) in central service centrebydeployinggraduatepersonfor EnquiryClerkcumComputeroperaterat servicecentreforreceiving&recordingthe complaints in complaint register & to assign to the workers & making abstract after attending the complaints at the end of the day on all days ofthemonthi/conholidaysandwatchand ward of service centre.(03 Nos Per day) 10 Providingservices for attending complaints of day to day maintenance carrying outpainting work and other related misellaneous nature of complaints/works,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM).Painter (02 Nos Per day) 11 Providingservices for attending complaints of day to day maintenance carrying outcarpentrywork and other related misellaneous nature of complaints,includingthecostofT&Pbut excludingthecostofmaterialswhichshallbe issued by department as per direction of Engineer-in-charge.(Allworkingdaysbetween 9 AM to 5 PM).Supervisor (02 Nos Per day) 12 Providingservicesof helper to trades man for attending complaints of day to day maintenance work(Allworkingdaysbetween 9 AM to 5 PM).Helper for service center (02 Nos Per day) 13 Supply only Twisted steel/ deformed TMT bars Fe-500D 14 Supply only Structural steel such as tees, angles channels and R.S. joists 15 Supply only Kota stone slab 20 mm to 25 mm thick (semi-polished) 16 Supply only Kota stone slab 25 mm thick (rough chiselled) 17 Supply only Red sand stone slab 45 mm to 50 mm thick (un-dressed) 18 Supply only Mirror of superior make glass 60x45 cm 19 Supply only G.I. pipes 15 mm diameter 20 Supply only G.I. pipes 20 mm diameter 21 Supply only G.I. pipes 25 mm diameter 22 Supply only G.I. pipes 32 mm diameter 23 Supply only G.I. pipes 40 mm diameter 24 Supply only G.I. Union 15 mm nominal bore 25 Supply only G.I. Union 20 mm nominal bore 26 Supply only G.I. Union 25 mm nominal bore 27 Supply only G.I. Union 32 mm nominal bore 28 Supply only G.I Union 40 mm nominal bore 29 Supply only Plasticised P.V.C. connection pipe with brass union 30 cm long 15 mm bore 30 Supply only Unplasticized P.V.C. connection pipe with brass union 45 cm long. 15 mm bore 31 Supply only Vitreous China flat back wash basin 630x450 mm 32 Mineral Fiber Ceiling Tile 600x600 mm 33 Supply only Common burnt clay F.P.S. (nonmodular) bricks class designation 7.5 34 Supply only Double charge vitrified tile polished finish of any Size 35 Supply only 600x120 mm glass shelf with anodised aluminium angle frame, C.P. brass brackets and guard rail of standard size 36 Supply only Vitreous china flat back wash basin 550x400 mm 37 Supply only Dash fastener/Chemical fastener 38 Supply only Chromium plated brackets (curtain rods) 25 mm diameter. 39 Supply only Galvanised wire mesh of average width of aperture 1.4 mm and nominal diameter of wire 0.63 mm 40 Supply only Aluminium hanging floor door stopper with twin rubber & stopper 41 Supply only Hydraulic door closer tubular type Aluminium section body-80 kg 42 Supply only Acid and alkali resistant tiles any size, 10 mm thick 43 Supply only Stainless steel kitchen sink - without drain board 610x510 mm bowl depth 200 mm 44 Supply only Semi Rigid PVC waste pipe for sink and wash basin 32 mm diameter with length not less than 700 mm i/c PVC waste fittings 45 Supply only Semi Rigid PVC waste pipe for sink and wash basin 40 mm diameter with length not less than 700 mm i/c PVC waste fittings 46 Supply only PVC waste pipe flexible pipe (coil shaped) with fittings32 mm diameter with length not less than 700 mm 47 Supply only Rectangular shape 600x450 mm precast R.C.C. manhole cover with frame - L.D. - 25 48 Supply only Rectangular shape 500x500 mm precast R.C.C. manhole cover with frame - M.D. - 10 49 Supply only Circular shape 560 mm diameter precast R.C.C. manhole cover with frame - H.D. - 20 50 Supply only C.P. Brass long body bibcock 15 mm 51 Supply only C.P. Brass angle valve 15 mm 52 Supply only Aluminium T or L sections 53 Supply only Flushing Cistern P.V.C. 10 litre capacity (low level) (White) (with fittings, accessories and flush pipe) 54 Supply only Flushing Cistern P.V.C. 10 litre capacity (low level) (White) (with fittings, accessories and flush pipe) 55 Supply only 15 mm C.P. brass tap with elbow operation lever 56 Supply only Precast R.C.C. grating with frame 500x450 mm horizontal grating 57 Supply only Double action hydraulic floor spring with stainless steel cover plate 58 Supply only 125 mm grating with waste hole 59 Supply only Aluminium U beading 60 Supply only Prelaminated particle board with both sides decorative lamination, flat pressed 3 layer & graded (medium density) Grade I, Type II conforming to IS : 12823 (exterior grade) 12 mm thick 61 Supply only Ceramic Glazed Tiles 1st quality any size in all shades designs except White, Ivory, Grey, Fume Red Brown etc. 62 Supply only P.T.M.T. extension nipple 15 mm diameter 63 Supply only P.T.M.T. extension nipple 20 mm diameter 64 Supply only P.T.M.T. extension nipple 25 mm diameter 65 Supply only Acrylic exterior paint 66 Supply only CPVC Pipe 15 mm diameter 67 Supply only CPVC Pipe 20 mm diameter 68 Supply only CPVC Pipe 25 mm diameter 69 Supply only CPVC Pipe 32 mm diameter 70 Supply only CPVC Pipe 50 mm diameter 71 Supply only CPVC Pipe 65 mm diameter 72 Supply only Autoclaved aerated cement (AAC) blocks 73 Supply only Aluminium round shape handle (anodised AC 15)outer diameter 100 mm 74 CP Shower Head 75 Supply only Stone Aggregate (Single size) : 20 mm nominal size 76 Supply only Stone Aggregate (Single size) : 10 mm nominal size 77 Supply only Portland Cement (OPC-43 grade) 78 Supply only SS316 Grade 2 ball bearing hinges 102x76x3 mm (HG1153ASS) with screws etc. complete in all respect as per manufacturers specifications and as directed by Engineer-in-charge 79 Supply only SS316 Aldrop of 2501x16 mm with screws 80 Supply only SS316 grade tower bolt 250x10 mm of approved make 81 Supply only SS316 grade tower bolt 150x10 mm of approved make 82 Supply only SS316 grade tower bolt 450x10 mm of approved make 83 Supply only SS316 grade D type handle 150 mm of approved make 84 Supply only SS316 grade D type handle 300 mm of approved make 85 CP Sensor Piller Cock 86 CP Sensor Mixer Cock 87 CP Health Facuet 88 Laminated Glass 6 MM Clear Toughend Glass + 1.52 MM PVB + 6MM Clear Toughened Glass 89 Full size float mirror 90 Vision Panel of 6 mm thickness 91 Laquered Glass of 6 mm thickness 92 Toughened clear glass 6 mm thick 93 3D hinges for UPVC doors 94 2D hinges for UPVC doors 95 Lock cylinder for UPVC doors 96 Supply only 35 mm thick IS certified flush door laminated both sides of approved make 97 Supply only Acrylic distemper 1st quality, having VOC content less than 50 grams/litre 98 SGU glass 6 mm thick ST 436 reflective toughened glass 99 Supply only Premium plastic acrylic emulsion of interior grade, having VOC content less than 50 grams/litre 100 Supply only White cement-based putty 101 Supply only Synthetic enamel paint in black or chocolate shade 102 Supply only Synthetic enamel paint in all shades except black or chocolate shade 103 Supply only Acrylic Exterior Primer 104 Supply only Coarse sand (zone III) 105 Supply only Fine sand (zone IV) 106 Supply only C.I. bracket for wash basin and sinks 107 Supply only C.I. cover and frame 300x300 mm inside 108 Supply only C.I. cover without frame 300x300 mm inside i/c cover of 4.50 kg 109 Supply only Rectangular cover 455x610 mm with frame (low duty) 110 Supply only Rectangular cover 455x610 mm without frame (low duty) 111 Supply only S.C.I. soil, waste and vent single socketed pipe 1.80 metres long:100 mm diameter. 112 Supply only Polyethylene water storage tank with cover and suitable locking arrangement 113 Supply only White plastic seat (solid) with lid C.P. brass hinges and rubber buffers 114 Supply only 100 mm S.C.I. trap with 100 mm inlet and 100 mm outlet 115 Supply only C.P. waste Jaali (For wash basin & Kitchen sink ) 32 mm nominal bore 116 Supply only Vitreous China pedestal type water closet 117 Supply only C.P. Brass bibcock 15 mm 118 Supply only Neoprene/EPDM rubber gasket 119 Supply only 15 mm nominal bore and 45 cm length PVC connection pipe with P.T.M.T. Nuts 120 Supply only Stainless steel screws 50 mm 121 Supply only Stainless steel screws 40 mm 122 Supply only Stainless steel screws 30 mm 123 Supply only Stainless steel screws 20 mm 124 Supply only Stainless steel butt hinges (Heavy Weight) 125x64x1.9 mm IS: 12817 marked 125 Supply only Stainless steel butt hinges (Heavy Weight) 100x60x2.5 mm IS: 12817 marked 126 Supply only Stainless steel butt hinges (Heavy Weight) 75x50x2.5 mm IS: 12817 marked 127 DGU Glass outer 6 mm thick KT 440 reflective toughened glass + 12 mm air gap + inner 6 mm thick clear toughened glass 128 SS 316 Grade Wiremesh for SS safety door 0.5 mm 129 SS 316 Grade Wiremesh for UPVC door 0.5 mm 130 Supply only Revolving Door hinges of SS 316 grade for Handicapped toilet door shutter 131 Supply only SS 316 Grade concealed flush bolt for fire doors 132 Supply only of approved make manufactured SS 316 Grade D Type 150 mm pull handle with 22 MM dia fixed with SS screws etc. complete in all respect as per manufacturer specification and as directed by Engineer-in-charge 133 Supply only Chlorinated Polyvinyl - chloride (CPVC) pipe 20 mm outer diameter 134 Supply only Chlorinated Polyvinyl - chloride (CPVC) pipe 25 mm outer Diameter 135 Supply only Chlorinated Polyvinyl - chloride (CPVC) pipe 32 mm outer diameter 136 Supply only of approved make manufactured SS 316 Grade D Type 300 mm pull handle with 22 MM dia fixed with SS screws etc. complete in all respect as per manufacturer specification and as directed by Engineer-in-charge 137 Supply only of approved make manufactured SS 316 Grade Mortice dead lock 138 Supply only panic trim for fire door complete in all respect as per manufacturer specification and as directed by Engineer-in-charge 139 Supply only Superior copal varnish 140 Supply only Superior spar varnish 141 Supply only Gypsum of approved make 142 Supply only First class teak wood in scantling 143 Supply only 18 mm thick Italian Marble stone slab, of approved shade 144 Supply only Silicon based Joint Sealant for Tiles 145 Supply only Epoxy based sealing Compound 146 Supply only C.P. Brass toilet paper holder of standard size 147 Supply only Floor mounted white vitreous China double trap syphonic WC with 10 litre cistern and all fittings & fixtures, seat cover etc 148 Supply only fly ash 149 Supply only Epoxy adhesive 150 Supply only CP Bottle trap 151 Supply only CP Soap Dish/holder 138x102x75 mm 152 Supply only Vitrified Tiles 153 Supply only Calcium Silicate tegular edged ceiling tiles 595x595 mm and 15 mm thick on edges 154 Supply only Stainless steel (SS304 grade) adjustable friction window stays 205x19 mm 155 Supply only Stainless steel (SS 304 grade) adjustable friction window stay 255x19 mm 156 Supply only Stainless steel (SS 304 grade) adjustable friction window stay 355x19 mm 157 Supply only Stainless steel (SS 304 grade) adjustable friction window stay 510x19 mm 158 Supply only Stainless steel (SS 304 grade) adjustable friction window stay 710x19 mm 159 Supply only Epoxy Grout 160 Provision for brooms and other sweeping materials 161 Supply of aluminium die cast body tubular type universal Fire Rated hydraulic door closer (2 Hrs fire Rated) (door weight upto 60 kg), with speed adjustment along with necessary accessories and screws etc. complete of Approved Make. 162 Supply of aluminium die cast body tubular type universal Fire Rated hydraulic door closer (2 Hrs fire Rated) (door weight upto 120 kg), with speed adjustment along with necessary accessories and screws etc. complete of Approved Make. 163 Supply of approved make manufactured Stainless Steel Mortice Lever handle D type , Mortice Sash lock with 65 mm CD & 50 mm Backset along with key Cylinder fixing Option & Euro Profile Cylinder both side key 60 mm (19MM)) with SS screws etc.complete in all respects as per manufacturers specifications & as directed by Engineer in charge 164 Supply of approved make manufactured Mortice Dead lock 50 mm (S.S. 316) Backset along with key cylinder fixing Option with SS screws etc.complete in all respects as per manufacturers specifications & as directed by Engineer-in-charge. 165 Providing approvedmake manufactured Shaft Lock (SH320) Back set 32mm and dead bolt stroke 18mm ,total length of lock 61mm and key turn operated complete in all respects as per manufacturers specifications & as directed by Engineer-incharge- SS 316 grade 166 Supply of approved make manufactured Door Buffer wall mounted stopper 22 mm dia,75 mm long (DBWC (22)) with Cover fixed with SS screwsetc. Complete in all respects as per manufacturers specificatios & as directed by Engineer-incharge 167 Supply of the G.I. metallic powder Coated GI ceiling tiles In size 600mm x 600 mm x 0.6 mm & colour RAL 9003 white & having perforation of 1.8 dia circle witha backing of factory pressed black non woven tissue the epoxy powder coat should electro statically be applied in a controlled environment as per approved make & as directed by Engineer-incharge 168 Supply of the Aluminium ceiling tiles In size 600mm x 600 mm x 0.6 mm & colour RAL 9003 white & having perforation of 1.8 dia circle witha backing of factory pressed black non woven tissue the epoxy powder coat should electro statically be applied in a controlled environment as per approved make & as directed by Engineer-incharge 169 Supply of 10 mm thick Calcium Silicate Board made with Calcareous & Siliceous materials reinforced with cellulose fiber manufactured through autoclaving process as per approved make & as directed by Engineer-incharge 170 Supplying of Moisture Resistant (MR) Gypsum Board of size 12.5 mm thickness, tapered edge, confirming to IS: 2095 (Part 1) / ASTM C1396, manufactured with water-repellent additives in the core, faced with moisture-resistant green-coloured paper on both sides. The board shall be factory-finished, properly stacked, and transported with care to avoid any damages, all complete as per manufacturers specifications and as directed by Engineer-in-Charge. 171 Supplying of Cement Bonded Particle Board (Bison Board) of approved make, of thickness 10 mm / 12 mm / 16 mm / 18 mm (as specified), conforming to IS: 14276, manufactured from wood particles bonded with cement and additives to enhance moisture resistance, termite resistance, and fire-retardant properties. The board shall be factory-made, flat, smooth, and free from warps or defects, suitable for internal and external applications. The boards shall be delivered at site properly stacked, all complete as per manufacturer’s specification and direction of Engineer-in-Charge. 172 Supply of Anti-Bacterial paint of approved make as per manufacturer’s specifications. The paint shall be water-based 100% acrylic emulsion with anti-bacterial and anti-fungal properties, tested as per relevant ASTM or IS standards, and shall be capable of resisting microbial growth on dry paint film. 173 Kitchen Cabinet SS 316 Channel 174 SS 316 Grade Soft close hinges 175 Cupboard Soft close hinges of SS 316 Grade 176 Cupboard D type handle 150mm of SS 316 Grade 177 Cupboard lock SS 316 grade 178 Cupboard Channel 179 Supply of Vitrified Anti skid tile of approved make & as directed by Engineer-incharge 180 SS 316 H type handle 600 mm 181 Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound) content less than 50 gram/litre, of approved brand and of required shade and colour complete to give and even shade, Old work (one or more coats). Annual Repair Work (Civil) 182 Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Annual Repair Work (Civil) 183 Finishing walls with Acrylic Smooth exterior paint of required shade, Old work (One or more coat applied @ 0.90 ltr/10 sqm).Annual Repair Work (Civil) 184 Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.Annual Repair Work (Civil) 185 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade One or more coats on old work 186 Cleaning and desilting of gully trap chamber, including removal of rubbish mixed with earth etc. and disposal of same, all as per the direction of Engineer-in-charge. 187 Cleaning of chocked sewer line by diesel running vehicle mounting hydraulic operated high pressure suction cum jetting sewer cleaning machine fitted with pump having 4000 litres suction capacity and 6000 litres water jetting tank capacity including skilled operator, supervising engineer etc. for cleaning and partial de-silting of manholes and de-chocking of sewer lines. De-chocking and flushing of sewer line from one manhole to another by high pressure jetting system of 2200 PSI for sewer line from 150 mm dia upto 300 mm dia for all depth. 188 Cleaning of under ground sump, Over Head R.C.C. Tank ( independent staging) including disposal of silt and rubbish, all as per direction of Engineer-in-Charge. The cleaning shall consistfollowing operations:- (i)Tank shall be emptied of water by pumping & bottom shall be cleaned of silt and otherdeposits. (ii) Entire surface area of the sump shall then scrubbed thoroughly with wire brush etc. and pressure washed with water. (iii) Chlorination of RCC internal surface by liquid chlorine. (iv) The treated surface shall be dried using air jetting and all loose particles shall be removal from the surface .(v) Finally the surface shall be treated with ultraviolet radiation etc. as per direction of Engineer-in-Charge. 189 Disposal of building rubbish/malba/similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. 190 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 191 12 mm cement plaster of mix : 1:6 (1 cement: 6 fine sand) 192 Providing and applying 12 mm thick (average) premixed formulated one coat gypsum lightweight plaster having additives and light weight aggregates as vermiculite per liter respectively conforming to IS: 2547 (Part- 1 & II) 1976, applied on hacked / uneven background such as bare brick/block/ RCC work on walls & ceiling at all floors and locations, finished in smooth line and level etc. complete. 193 Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) 194 Providing and laying autoclaved aerated Concrete (AAC) blocks masonry with 100 mm / 125 mm thick with Grade 1 AAC blocks of density 551 to 650 Kg/cum conforming to IS:2185 (Part 3) in super structure above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse sand ). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars at every third course of masonry work. 195 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in with Cement mortar 1:6 (1 cement : 6 coarse sand) 196 With water thinnable cement primer on wall surface having VOC content less than 50 grams per litre. 197 Providing and fixing ready made 304 grade stainless steel Modular kitchen basket and accessories such as right angle basket (Plain Cup & Saucer, plant, Partition, Bottle rack, Thali, Cutlery) kitchen utensil basket, Dinner set basket, kitchen grain basket, Multipurpose basket as per site requirement including finishing (wherever required) and fittings. The same shall be fixed with necessary stainless steel nuts & bolst, Stainless Steel screws & telescopic channel etc. as per direction of Engineer-in-charge. (For payment purpose only weight of Stainless steel basket shall be considered excluding weight of all fixing accessories such as nuts, bolts, fasteners telescopic basket channels etc.) 198 Façade cleaning two times in a year ( one annually and one as and when required) 199 Day to Day Maintenance of Horticulture Worksfor 24 monthsComplete maintenance of the entire garden features having as per yardstick in the garden area i.e. lawn trees,shrubs.,herbs, edge, flower beds, foliage, creepers, etc. including hoeing, and weeding. pruning, replacement of plants. gap filling, watering, mowing of lawn, grass cutting by lawn mover and brush cutter, removal of garden waste, applying insecticide, pesticide & fertilizers(whenever required) top dressing of lawn with good earth and manure and maintenance of other garden related works as directed by office-in-charge (Cost of Good Earth, Manure, Fertilizer, Insecticide. Pesticide will be provided by the Department & lawn mover and brush cutter with fuel and other T&P material/articles shall be provided by the contractor.) and as per direction of officer in charge 200 Permanent office accommodation. (1 Mali for 1.25Acre) 201 Flats (1 Mali for 1.35 Acre) 202 Clearing grass and removal of therubbishfor 24 months up to a distance of 50m outside the periphery of the area cleared. 203 Complete maintenance of trees (Outside garden features) for 24 months. Jobs like making of basin at regular intervals i/c watering, weeding, pruning & application of fertilizer, etc (excluding the cost of material which shall be supplied by the department and other T & P materials/articles shall be provided by the contractor) and as per direction of officer in charge. 204 Trees for 250 Nos (up to 4 & up to 3 year Slow & Fast growing group) trees 205 Complete maintenance of shrubs (outside garden features)for 24 months, jobs like making of basin at regular interval i/c watering, weeding, pruning & application of fertilizer etc. (excluding the cost of material which shall be supplied bythe department) and as per direction of officer in charge. 206 Cutting of Hedge/Edge including removing of cut material, cleaning, hoeing of hedge/Edge bed watering, manureing and applying insecticides and fungicides etc. (excluding the cost of material which shall be supplied by per sqm the department) and as per direction of officer in chargefor 24 months. 207 Maintenance of cement potted plants at ground floor in flats and ground floor bungalow, office complex including application of good earth, manure, insecticide, pesticide and fertilizer, removing of dry parts by pruning, cleaning dry leaves and displaying in appropriate place and replacement of broken pots, colouring of pots and change of location of pots and replacing with fresh plants as and when required (materials provided by the department) as per direction of officer in charge for 24 months. 208 Maintenance of potted plants, earthern pots in display at multistored office, buildings, flats and ground floor bungalow, office complex including application of good earth, manure, insecticide, pesticide and fertilizer, removing of dry parts by pruning, cleaning of dry leaves and displaying in appropriate place and replacement of broken pots, colouring of pots & change of location of pots and replacing with fresh plants as and when required (materials provided by the department)as per direction of officer in charge for 24 months. 209 Removal of garden waste by TATA 407 or equivalent including loading/unloading and carriage upto 1km lead, complete disposal upto designated place as per direction of officer-in-charge. 210 Material (Horticulture) for 24 monthsSupply of chemical fertilizer 211 N.P.K. (19.19.19) 212 Supply of Organic fertilizer 213 Neem Cake 214 Vermicompost 215 Provision of mortality replacement for 24 months 216 Trees 217 Shrubs 218 Provision for replacement of cement pots for 24 months 219 Supplying and stacking of good earth at side including royalty and carriage upto 5 km complete (earth measured in stacks will be reduced by 20% for payment) for 24 months 220 Supplying and stacking of well decayed cattle manure at site including royalty and carriage upto 5km lead complete (Cattle manure measured in stacks will reduced by 8% for payment) for 24 months 221 Provision for plants i.e. pesticides/fungicides/neem oil (Lumpsum for 24 months) 222 Provision for sessional flowering plants (Lumpsum for 24 months) 223 A. Internal & External Electrical InstallationProviding services of highly skilled Supervisor for upkeep the record up to date & look after for all the available staff involved as per terms & conditions attached for all above specialized/O.E.M. services at site for supervising above services during general duty hours of 9AM to 5 PM on all working days including Sundays and holidays .a) Supervisor -02 Nos. (01 for north parcel + 01 for south parcel) 224 Providing services of Computer Operator at service center on all working days during general shift from 9AM to 5PM. Job includes the assistance of official work to concerned JE/AE/EE, maintenance of service center records, day to day monitoringof complaint status, compilation of various reports of E&M Services etc. (The Computer with all accessories office furniture and space shall be provided by the Department free of cost). a) Computer Operator 02 Nos-[01 in the office of AE(E)/JE(E) & 01 in the office of EE(E)]. 225 Day to day maintenance ofinternal EI, light fittings, MCB DBs and external street light and cabling in three shifts on all working days i/c sundays and holidaysas reqd. as per terms & conditions and inventory attached .a) Wireman - 18 nos.(3+3) no. each in three shift for north and south parcel).b) Helper - 18 nos.(3+3) no. each in three shift for north and south parcel). 226 Substation & DG SetOperationand routine preventive maintenance services of 11/0.433 KV Sub station equipments i/c H.T & L.T Panels, APFC Panels & DG sets in three shifts on all working days i/c Sundays & Holidays etc. complete as required as per terms & conditions attached complete as required .a) Electrician - 12 nos. (2+2)each in three shift for north parcel & south parcel.b) Helper -12 nos. (2+2) each in three shift for north parcel & south parcel. 227 LiftsOperation, Rescue management and complaint reporting to OEM forMicroprocessor controlled variable frequency single speed passengers, hospital and goods/stretcher liftsinstalled in different buildingscomplete as reqd. as per terms & conditions on all working days i/c sundays & holidays. (Sitting inside lift car is NOT under scope) (as per duty chart attached). a) Lift operator - 24 nos. at north parcel & 21 nos. at south parcel 228 Fire Fighting System, Water Supply Pumps and STPOperation and routine maintenance of Fire Fighting System &Water Supply Pumpsround the clock on all working days i/c Sundays & holidays as per terms & conditions attached complete as required. Total operator: 12 nos.Total Helper: 12 nos. a) Operator- 08 nos.[ (2+2)each in two shifts, north parcel & south parcel].b) Helper - 08 nos. [(2+2)each in two shifts, north parcel & south parcel.]c) Operator- 02 nos.[(1+1)each in night shift, north parcel & south parcel.]d) Helper - 02 nos.[(1+1) each in night shift, north parcel & south parcel.]e) Operator - 2 nos For STP in General shift STPf)Helper - 02 nos. for STP in General shift STP 229 Fire Alarm, BMS, LAN, WiFi, CCTV, Access Control, Audio-Visual& EPABX SystemOperation and routine maintenance of Addressable Fire Detection system, Building Management System (BMS), LAN, CCTV system, Access Control System, Audio-visual System, EPABX and other low voltage systems i/c all connected equipments and accessories as per terms & conditions daily on all workingdays including sundays and holidays etc. complete as reqd. a) Technician- 09 nos [(3) nos. each in 3 shift]b) Helper- 09 nos(03 nos. each in 3 shift) 230 HVAC Operation of 5 x 800 TR, 1 x 200 TR capacity AC plants and Ventilation system with fans i/c allied equipments,hot water generator,Precision ACs - 5 Nos. and connected AHU’s as per details enclosed (Round the clock) in three shiftsdaily on all workingdays i/c Sundays and holidays as per terms & conditions attached complete as required. a) Supervisor - 01 no. in general shift (9am to 5pm)b) Operator- 06 nos(02 in each shift)c) Helper- 06 nos(02 in each shift)d) Operator- 01 no (General shift- 9am to 5pm)e) Helper- 01 no (General shift- 9am to 5pm) 231 Medical Services Providing services for operation & up keep of Medical Services Systems installed as per list attached on all workingdays including Sundays and holidays as per terms and conditions attached complete as reqd. a) Supervisor - 01nos. (for north parcel)b) Manifold Technician (Gas Steward) 06 nos. (2nos. each in 3 shifts).c) Gas/Pump mechanic- 02 nos. (01 no.each in twoshifts) d) Manifold room Attendent(Helper)-01no. in general shift (9am to 5pm) 232 Operated and routine maintenance of AWLS in two shifts & PTS in three shift on all working days i/c sundays & holidays as per terms and conditions attached complete as requiredOperator - 07 nos.Helper- 07 nos.AWLS a) 02 nos. Operator for AWLS in each shift i.e. two shiftsb) 02 nos. Helper for AWLS in each shift i.e. two shifts.PTSa) 01 nos. Operator for PTS in each shift i.e. three shifts for PTS.b) 01 nos. helper for PTS in each shift ie. three shifts for PTS. 233 Material & SparesDuring maintenance Providing and replacemet of following electrical accessories suitable for existing different type fitting, fan/Exfan & switch box etc. as required. (Labour already included in Appendix - E) 234 2.5/3.5 mfd condensers 235 Ceiling rose, 3 pin, 5 amps ISI marked 236 Stepped type Modular Fan regulator (2 module) 237 Modular blanking plate 238 6 pin 25 amp modular type socket ISI Marked 239 Modular bell push, ISI marked 240 20/25 modular SPMCB, ‘C’ curve 241 Modular base & cover plate for 1 module 242 Modular base & cover plate for 2 module 243 Modular base & cover plate for 3 module 244 Modular base & cover plate for 4 module 245 Modular base & cover plate for 6 module 246 Modular base & cover plate for 8 module 247 Modular base & cover plate for 12 module 248 S.P. 5/6 A, one way modular switch, ISI marked 249 S.P. 5/6 A, two way modular switch, ISI marked 250 3 pin 5/6 A modular socket outlet, ISI marked 251 S.P. 15/16 A, one way modular switch, ISI marked 252 6 pin 15/16 A modular socket outlet, ISI marked 253 Telephone Socket outlet modular type 254 T.V. Socket outlet modular type 255 Call bell/ buzzer, single phase 256 UTP 4 Pair CAT 6 LAN Cable 257 PVC Batten - 25mm/32mm 258 6 amps. to 32 amps. ratings, SPMCB, “C” curve, 10 kA breaking capacity 259 6 amps. to 32 amps. ratings, SPN MCB, “C” curve, 10 KA breaking capacity 260 6 amps. to 32 amps. ratings, DP MCB, “C” curve, 10 KA breaking capacity 261 Single pole, blanking plate 262 100 A, 16 KA,TPMCCB 263 125 A, 16 KA,TPMCCB 264 150 A/160A, 16 KA,TPMCCB 265 250 A, 25 KA,TPMCCB 266 125 A, 36 KA, FPMCCB 267 200 A, 36 KA, FPMCCB 268 250 A, 36 KA, FPMCCB 269 400 A, 50 KA,FPMCCB 270 40 amps., 2 pole isolator 271 63 amps., 2 pole isolator 272 40 amps., 4 pole isolator 273 63 amps., 4 pole isolator 274 40 amps. ratings, SPN MCB, “C” curve, 10 KA breaking capacity 275 63 A ratings, SPN MCB, “C” curve, 10 kA breaking capacity 276 63 A ratings, TPN MCB, “C” curve, 10 kA breaking capacity 277 1.5 sqmm. FRLS Copper conductor cable 278 4.0 sqmm. FRLS Copper conductor cable 279 6.0 sqmm. FRLS Copper conductor cable 280 10 sqmm. FRLS PVC insulated, single core copper conductor cable 281 16 sqmm. FRLS PVC insulated, single core copper conductor cable 282 Co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid protected with PVC sheath 283 1 pair, 0.5 mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, telephone cable 284 2 pair, 0.5 mm dia annealed copper conductor, FRLS PVC insulated, unarmoured, telephone cable 285 Heat Detectors of electronic Rate of Rise cum fixed tempreature (Dual Thermistor) type with mounting base complete with all connection etc. 286 Smoke Detector with built in LED, mounting base complete with all connection etc. 287 Manual call boxes of PVC Type in surface/recess with s complete with glass and push module (model NF/MCP/glass) 288 Response indicator on surface/recessed MS Box having two LED’s metallic covers complete with all connections etc. 289 Fire alarm sounders (electronic) with facility to make announcement, mounted in M.S. Box (16 SWG) with hinged cover plate & suitable for operation with amplifier i/c line matching ttransformer etc 290 Fire alarm sounders (electronic) with facility to make announcement, mounted in A.B.S. Box with hinged cover plate & suitable for operation with amplifier i/c line matching ttransformer etc. 291 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos.blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM,350 RPM (tolerance as per IS : 374-2019), THD less than 10%, i/c electronic regulator unit for speed control and all remaining accessories including safety pin,nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply i/c allaccessoires /fittings /supports etc. 292 LED batten fitting of not more than 20 watt, 1200 mm long (Nominal size) suitable for G13 lamp holders, made of Al./ CRCA powder coated housing with 1 no. LED tube, Luminaire having system output >= 2000 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), CRI (Ra) > 80, luminaire life >= 50000hrs@L70, having THD < 20%, PF > 0.9, complete in all respect suitable for operation on 230V, single phase AC supply. 293 LED batten fitting of not more than 10 watt, 600 mm long (Nominal size) suitable made of Al./ CRCA powder coated housing, Luminaire having system output >= 1000 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), CRI (Ra) > 80, luminaire life >= 25000hrs@L70, having THD < 20%, PF > 0.9, complete in all respect suitable for operation on 230V, single phase AC supply, i/c fixing of fixture on ceiling/ wall etc. including connection with 1.5 sqmm. FRLS Copper conductor single core cable i/c earthing etc. as required. 294 Surface mounting Round/Square shaped (as per site requirement) professional LED downlighter fitting of not more than 12 watt, Luminaire having system output >= 1200 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), die cast aluminium housing with high efficiancy diffuser for glare free light output, CRI (Ra) > 80, luminaire life >= 50000hrs@L70, IP 20 or better protection complete in all respect i/c inbuilt BIS approved Electronic driver suitable for operation on 230V, single phase AC supply, having THD < 10%, PF > 0.9, surge protection level >= 2.5 kV, completesuitable for operation on 230 V, 50 Hz,1-ph. AC supply. 295 Surface mounting LED Bulkhead fitting of not more than 10 watt, Luminaire having system output >= 1000 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), die cast aluminium housing with high efficiancy diffuser, CRI (Ra) > 80, luminaire life >= 50000hrs@L70, IP 65 or better protection complete in all respect i/c inbuilt BIS approved Electronic driver suitable for operation on 230V, single phase AC supply, having THD < 10%, PF > 0.9, surge protection level >= 2.5 kV, complete suitable for operation on 230 V, 50 Hz,1-ph. AC supply. 296 Wall bracket luminiare made of SS finish body with textured glass/PC diffuser suitable for upto 9 watt led bulb with B22/E27 basei/c supplying of 7watt or better led bulb having lumens output 630 lumens or more, efficacy of bulb >=90 lumens/Watt, suitable for directoperation on 230V, 50 Hz, 1-ph, AC supply. 297 300 mm sweep, 900 rpm, Copper wound motor, double ball bearing type heavy duty exhaust fan conforming to IP-55 range, along with louver & shutter, having power consumption not more than 55W, Air Delivery>=1145 m3/hr, complete with all accessories suitable for direct operate on 1-ph, 230V, 50 Hz, A.C. supply. 298 250 mm sweep fresh air-fan, having Power Consumption <=45 Watt, Air Delivery >= 720 CMH, complete suitable for operation on 230 V, 50 Hz,1-ph. AC supply in the existing opening/ventilation window etc.. 299 Upgradation & Maintainance, I/C Additions & AlterationsWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box andarthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required 300 Group A 301 Group B 302 Group C 303 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required.4 X 10 sq. mm + 2 X 6 sq. mm earth wire 304 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 305 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 306 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 307 Rewinding of Ceiling/Exhaust Fan motor (starting and running winding) including all necessary material and the motor is to be wound taking no. of coils, turns and pitch as it was originally wound with required size super enamelled wire with E class insulation material and making connections i/c credit cost of dismantled material at site etc. as required. 308 1200/1400 mm sweep 309 300 mm sweep Exhaust Fan 310 Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 311 3 x 1.5 sq. mm 312 3 x 4 sq. mm 313 6x 4 sq. mm 314 3 x 6 sq. mm 315 6 x 6 sq. mm 316 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required.2 Pair 317 Supplying and drawing co-axial TV cable RG-6 grade, 0.7 mm solid copper conductor PE insulated, shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. 318 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 319 20mm 320 25mm 321 32mm 322 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 323 5/6 A switch 324 2 Way 5/6 Switch 325 15/16 A switch 326 3 pin 5/6 A socket outlet 327 6 pin 15/16 A socket outlet 328 Telephone socket outlet 329 TV antenna socket outlet 330 Bell Push 331 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm 332 Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 333 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 334 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. 335 1 or 2 Module 336 3 Module 337 4 Module 338 6 Module 339 8 Module 340 12 Module 341 Supplying and fixing following Modular base & cover plate on existing modular metal boxes etc. as required. 342 1 or 2 Module 343 3 Module 344 4 Module 345 6 Module 346 8 Module 347 12 Module 348 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 349 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 350 Supplying and fixing call bell/ buzzer suitable for single phase, 230 V, complete as required. 351 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/recessed steel/ PVC conduit as required. 352 1 run of Cable 353 2 run of Cable 354 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providng and fixing 2 nos. 3 pin 5/6 A modular socket outlet and 2 nos. 5/6 A modular switch, connections etc. as required. (For light plugs to be used in non residential buildings). 355 Supplying & fixing suitable size GI box wih modular plate and cover in front on surface or in recess including providing and fixing 25 A modular socket outlet and 25 A modular SP MCB, C curve including connections, painting etc. as required. 356 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted includingearthing etc. as required. (But without MCB/RCCB/Isolator) 357 12 way, Double door 358 16 way, Double door 359 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required.(as per existing MCCB ) 360 200 A, 16 KA,TPMCCB 361 315 A, 35 KA,TPMCCB 362 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 363 4 way (4 + 12), Double door 364 6 way (4 + 18), Double door 365 8 way (4 + 24), Double door 366 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 367 4 way (4 + 12), Double door 368 8 way (4 + 24), Double door 369 Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 370 Single pole 371 Double pole 372 Supplying and fixing DP sheet steel enclosure on surface/ recess along with 25/32 A 240 V C curve DP MCB complete with connections, testing and commissioning etc. as required. 373 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V C curve TP MCB complete with connections, testing and commissioning etc. as required. 374 LT/HT CableWorkSupplyingof one number PVC insulated and PVC sheathed / XLPE aluminium armoured UG power cable of 1.1 KV grade Conforming to IS 7098 Part-1/1988 with upto date ammendments of following size. 375 2 X 10 sq. mm 376 2 X 16 sq. mm 377 3½ X 35 sq.mm 378 3½ X 50 sq.mm 379 3½ X 70 sq.mm 380 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL/ HDPE pipe as required. 381 Upto 35 sq. mm 382 Above 35 sq. mm and upto 95 sq. mm 383 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. 384 Upto 35 sq. mm 385 Above 35 sq. mm and upto 95 sq. mm 386 Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surfaceetc. as requred. 387 Upto 35 sq. Mm (clamped with 1mm thick saddle) 388 Above 35 sq. mm and upto 95 sq.mm (clamped with 25x3mmMS flat clamp) 389 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. 390 Upto 35 sq. Mm (clamped with 1mm thick saddle) 391 Above 35 sq. mm and upto 95 sq. Mm (clamped with 25x3mm MS flat clamp) 392 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 393 2 X 10 sq. mm 394 2 X 16 sq. mm 395 3½ X 35 sq. mm 396 3½ X 50 sq. mm 397 3.5 x 70 Sqmm 398 Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 399 3½ X 35 sq. mm 400 3½ X 50 sq. mm 401 3½ X 70 sq. mm 402 Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal) 403 Tracing and locating of underground LT cable fault by means of fault location sensing machine including pointing out the exact place of fault complete etc. as required at site. 404 Tracing and locating of underground HT cable fault by means of fault location sensing machine including pointing out the exact place of fault complete etc. as required at site. 405 Supply and Top up of Transformer/ Power Oil duly dehydrated in the existing transformer complete etc as reqd. 406 Dehyderation of transformer oil of using Dehyderation machine to reach the dielectric strengths to the desired level (min 50KV/mm) etc as reqd. 407 2500KVA transformer (05nos) (Make- VOLT amp) 408 1000 KVA transformer (06 nos.) (Make- VOLT amp) 409 Supplying, fixing, testing and commissioning of butterfly valve of PN 1.6 rating with bronze/gunmetal seat duly ISI marked complete with nuts, bolts, washers, gaskets conforming to IS 13095 of following sizes as required 410 80 mm dia 411 100 mm dia 412 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following sizes as required :100mm dia 413 Providing, installation, testing and commissioning of non-return valve of following sizes confirming to IS:5312 complete with rubber gasket, GI bolts, nuts, washers etc.as required40mm 414 Supplying and fixing 63 mm dia, 15 m long RRL hose pipe with 63 mm diamale and female couplings duly bound with GI wire, rivets etc. conforming to IS 636 (type-A) as requiredStainless steel (Grade 304) 415 Supplying & fixing 63 mm dia steel short branch pipe with 20 mm nominal internal diameter size nozzle conforming to IS 903 suitable for instantaneous connection to interconnect hose pipe coupling as required :Steel branch pipe 416 Providing, fixing, testing & commissioning of 15mm dia quartzoid bulb type sprinklers of rating 68 degree centigrade with required accessoriesPendent Sprinkler 417 Supplying and fixing first-aid Hose Reel with MS construction spray painted in post office red, conforming to IS 884 complete with the following as required. 20 mm nominal internal dia water hose thermoplastic (Textile reinforced) type -2 as per IS: 12585 20 mm nominal internal dia gun metal globe valve & nozzle. Drum and brackets for fixing the equipmets on wall. Connections from riser with 25 mm dia stop gun metal valve & M.S. Pipe and socket30 m/36m 418 Providing and fixing in pressure switch in M.S. Pipe line including connection etc as requried. 419 Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: One or more coats on old work) ( i.e. Painting of various metalic surface i/c scraping old paint from HT Panel, LT Panel, Transformer, Feeder Pillar, DBs, Loose Wire Box etc as reqd. 420 Supplying, Installation, Testing & Commissioning of 300 mm sweep, 900 rpm, Copper wound motor, double ball bearing type heavy duty exhaust fan conforming to IP-55 range, along with louver & shutter, having power consumption not more than 55W, Air Delivery>=1145 m3/hr, complete with all accessories suitable for direct operate on 1-ph, 230V, 50 Hz, A.C. supply, including making the hole to suit the size of the above fan, making good the damage, connection, earting etc. as required. 421 Supplying, installation, testing & commissioning of 250 mm sweep fresh air-fan, having Power Consumption <=45 Watt, Air Delivery >= 720 CMH, complete in all respect suitable for operation on 230 V, 50 Hz,1-ph. AC supply in the existing opening/ventilation window i/c including making the hole to suit the size of the above fan, making good the damage, connection, earting etc. as required. 422 Supplying, installation, testing and commissioning of Surface mounting LED Bulkhead fitting of not more than 10 watt, Luminaire having system output >= 1000 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), die cast aluminium housing with high efficiancy diffuser, CRI (Ra) > 80, luminaire life >= 50000hrs@L70, IP 65 or better protection complete in all respect i/c inbuilt BIS approved Electronic driver suitable for operation on 230V, single phase AC supply, having THD < 10%, PF > 0.9, surge protection level >= 2.5 kV, complete suitable for operation on 230 V, 50 Hz,1-ph. AC supply directlyi/c connections with 1.5 sqmm., PVC insulated, FRLS copper conductor, single core cable etc. as required. 423 Supplying, Installation, Testing & Commissioning of surface mounting Round/Square shaped (as per site requirement) professional LED downlighter fitting of not more than 12 watt, Luminaire having system output >= 1200 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), die cast aluminium housing with high efficiancy diffuser for glare free light output, CRI (Ra) > 80, luminaire life>=50000 hrs @L70, IP 20 or better protection complete in all respect i/c inbuilt BIS approved Electronic driver suitable for operation on 230V, single phase AC supply, having THD < 10%, PF > 0.9, surge protection level >= 2.5 kV, completesuitable for operation on 230 V, 50 Hz,1-ph. AC supply i/c connections with 1.5 sqmm., PVC insulated, FRLS copper conductor, single core cable etc. as required. 424 Supplying, Installation, Testing & Commissioning of Wall bracket luminiare made of SS finish body with textured glass/PC diffuser suitable for upto 9 watt led bulb with B22/E27 base i/c supplying of 7watt or better led bulb having lumens output 630 lumens or more, efficacy of bulb >=90 lumens/Watt, suitable for directoperation on 230V, 50 Hz, 1-ph, AC supply i/c connections with 1.5 sqmm., PVC insulated, FRLS copper conductor, single core cable etc. as required. 425 Supplying, installation, testing and commissioning ofLED Flood light fitting of not more than 90 watts, Luminaire having system output >= 11000 lm, Luminaire efficacy>=125 lm/W, CCT = Range 3000K to 5700K (as required and approved by E-in-C)), Powder coated die cast aluminium housing, CRI (Ra) > 70, luminaire life >= 50000hrs@L70, conforming to IP 66 or better complete in all respect i/c inbuilt BIS approved Electronic driver suitable for operation on 230V, single phase AC supply, having THD < 10%, PF > 0.9, complete with mounting of fixture on the existing pole bracket of pole/ building parapet etc. complete with necessary mounting accessories as per site requirement including connection with 1.5 sqmm. FRLS Copper conductor single core cable and earthing etc. as required. 426 Supply, Installation, Testing and Commissioning of LED batten fitting of not more than 20 watt, 1200 mm long (Nominal size) suitable for G13 lamp holders, made of Al./ CRCA powder coated housing with 1 no. LED tube, Luminaire having system output >= 2000 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), CRI (Ra) > 80, luminaire life >= 50000hrs@L70, having THD < 20%, PF > 0.9, complete in all respect suitable for operation on 230V, single phase AC supply, making connection with 1.5 sqmm. FRLS Copper conductor single core cable i/c earthing etc. as required. 427 Supply, Installation, Testing and Commissioning ofLED batten fitting of not more than 10 watt, 600 mm long (Nominal size) suitable made of Al./ CRCA powder coated housing, Luminaire having system output >= 1000 lm, Luminaire efficacy>=100 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), CRI (Ra) > 80, luminaire life >= 25000hrs@L70, having THD < 20%, PF > 0.9, complete in all respect suitable for operation on 230V, single phase AC supply, i/c fixing of fixture on ceiling/ wall etc. including connection with 1.5 sqmm. FRLS Copper conductor single core cable i/c earthing etc. as required. 428 Supply, Installation, Testing and Commissioning of recess/surface mounting LED Luminaire of nominal size 595mmx595mm Luminaire having system output >= 3300 lm, Luminaire efficacy>=110 lm/W, Colour temperature = (Range 3000K to 5700K (as required and Approved by E-in-C)), CRCA/ Aluminium housing with high efficiancy diffuser for glare free light output, UGR<19, CRI (Ra) > 80, luminaire life >= 50000hrs@L70, IP 20 or better protection complete in all respect i/c inbuilt BIS approved Electronic driver suitable for operation on 230V, 50Hz, single phase AC supply, having THD < 10%, PF > 0.9, surge protection level >= 2.5 kV, connection with 1.5 sqmm. FRLS Copper conductor single core cable i/c earthing etc. as required. 429 Supply, Installation, Testing and Commissioning of 24 port POE managed layer-2 Network Switch with 24 x 10/100/1000 Base-Tauto-sensing PoE+ ports,PoE+ budget: 380W or higher, 4dedicated 100/1000 Base-X Fiber SFP ports,Bandwidth: 56Gbps non- blocking,PoE budget: 190W, Mean TimeBetween Failures, PoE Timer should be configurable onports,PoE Power allocation on per port. VLAN: 256,IEEE802.3at PoE+,Access Control Lists (ACLs) L2/L3 L4,Configurable Management VLAN Admin access control viaRadius and TACACS+,Web-based graphical user interface( etc as required. 430 Supply, Installation, Testing and Commissioningof of 15U Wall mounted Communication rack with glassdoors, handles, lock, Top and Bottom Cable entries, Supportsfor mounting rack on wall , Cable managers, one Fan,Equipment mounting hardware, power supply box for supplyngpower to switches, fans etc along with earth continuity kit,Mcb, indicator, moulded power supply cable, 600 MM Depthetc. as required. 431 Supply, Installation, Testing and Commissioningof loaded 24 port CAT 6A UTP, Transparent shutter jack panel, 1U height, Black with cable support bar, clear label marks and earthing plug for CAT6A cable termination at rackend ready to use complete in all respect etc. as required at site. 432 Supply, Installation, Testing and Commissioningof Cat 6 Patch Chord of 1 meter length ready to use complete in all respect etc. as required at site 433 Supply of all-in-one recording, viewing and management solution for network surveillance systems for up to 32 channels, Pre-installed, pre-configured IP storage solution, with optional support of RAID-1, Dedicated storage operating system delivers robust , secure operation, Advanced user and alarm management, Intel® Core™ i3-10100E(6 MB Intel® Smart Cache,3.20 GHz),8GB DDR4-2666 1RX8 LP SODIMM, compact mini tower,2 Trays:3.5-inch SATA 3,max 18TB per HDD slot maximum supported,6 USB ports;Intel onboard graphics (Three digital outputs),Microsoft Windows Server IoT 2022 for Storage UL, CE Certified.2 x RJ45 Gigabit Ethernet LAN ports (teamed);Operating temperature (°C) 0°C to +40°C; Operating relative humidity, noncondensing (%) 8 - 90%.32 Channel NVR (Windows Based) 434 Supply, Installation, Testing and Commissioning of 6 TB Surveillance Hard Disc with high data redundancy for long time data storage complete in all respect etc. as required at site. 435 Supply, Installation, Testing and Commissioning of 55 LED 4K UHD Professional Slim LED Screeen having refresh rate @60 htz, HDR10 + support ,4K AI upscaling feature,bluetooth 5.0 or better connectivity, 3xHDMI port, 1xUSB, 2-Channel 20 watt speaker,IP Control feature and suitable for AC220-240V~ 50/60Hz with auto powersaving mode and with all related accessories i/c remote and stand etc. all complete as per direction of Engineer-in-charge. 436 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 437 1 run of Cable 438 2 run of Cable 439 Supply of Core Switch with 24 SFP+/SFP ports, 4 QSFP+ ports, 2 expansion slots, redundant fans, 2 AC power supplies, 2 power cords, 4-post rack mount kit,and front to back air ow,Switching capacity: 720 Gbps (unidirectional)/1.44 Tbps(bidirectional),Layer 2/Layer 3 throughput (maximum with 64 byte packets):1,071 Mpps (wire speed),etc as required.Approve Make (Juniper,Cisco, Extreme,Cambium ) 440 Supply of 10g Duplex sfp+ Optical Transceiver with Core size/cladding9/125 µm, Distance up to 10 km, etc as required Approve Make (Juniper,Cisco, Extreme,Cambium) 441 Supply of armoured 6 core Single mode OS2 (9/125 Micro), Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel music wire embedded in side sheathing as strength member forswitch connectivity. Cable should be ROHS compliant and as per IEC60749-1 with product warranty of 25 years.Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 442 Supply of 6F SM loaded LIU with LC adaptor plates, pigtel cables, Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, Powder Coaded 1.2mm steel sheet metal, 1U etc complete as required. LIU should be in accordance with YD/T 778-2006 Optical Distribution Frame & YD/T 1272.1- 2003 Optical Fiber Connector Part 1: Type LC and should have 25 years of product warranty.Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 443 Supply of LC-LC singlemode OS2 (9/125) duplex, LSZH fiber patch cord for LIU to switch connectivity. Patch Cord should have aramid yarn as strenght member with 1000 time mating cycle. Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 444 Supply of CAT 6A UTP LSZH Cable, 23 AWG solid copper conductors in accordance to TIA/EIA 568 C.2 (Category 6a) & ISO/IEC 11801 2nd ed(Class Ea), UL Approved, tested @500 Mhz, with HDPE insulation of individual conductor and over all Dia of 7.2 mm for Connectivity of Hub room to End Point. Grey ColorApproved Makes:Derwiser/Nexans/Siemon/Systimax/Legrand 445 Supply of CAT 6A UTP Universal (both tool & toolless) information outlet (I/O) in accordance with ANSI TIA 568 C.2, IEC 60603-7-4 2nd Edition, ISO/IEC TR 11801-9901- 2014, ROHS Compliant. The I/O should have minimum 750 mating cycle and 200 insertion cycle, for Data, Voice, & Wi-Fi at user end. Approved Makes:Derwiser/Nexans/Siemon/Systimax/Legrand 446 Supply of CAT 6A UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 2 Mtr for rack side switch to end user connectivity. Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 447 Supply of 1, 2 and 4 port face plate, British Style with Shutter, 2 Plate system clear finish with transparent labelling, ROHS Compliant, in accorandce with standards like ANSI/TIA-568-C.2, ISO/IEC 11801:2002 AMMD.2:2010, YD/T 926.3-2009 & ISO/IEC 60603-7 white for I/O fixing at user side. Approved Makes:Derwiser/Nexans/Siemon/Systimax/Legrand 448 Supply of 22U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Approved Makes: Der Wiser/MTS/Rittal/APC/APW/Valrack 449 Supply of 4MP MFZ Varifocal Dome Camera With 1/2.8” Progressive Scan CMOS,Maximum Resolution 2592 x 1520, Lens 2.7 ~ 13.5 mm, DC-Iris F1.6 , Minimum Illumination Color 0.006Lux @F2.0,IR Range Smart IR, 60 m, 04 IR LEDs,,Signal-to-Noise Ratio >55 db minimum,Electronic Shutter Range Auto/Manual, 1/3 ~ 1/100,000,Dynamic Range 140 db minimum,Back light compensation BLC, HLC, WDR,3D Noise Reduction, Inbuilt Analytics Smart Motion Detection, Tampering, Intrusion, Multi Loitering, People Counter, Tripwire, Abandoned object, missing object, audio detection,4 configurable windows,8 Region of Intrest, Compression,3D digital noise reduction (ON/OFF) color, brightness, sharpness, contrast, white balance, exposure control, backlight compensation/WDR, Local Storage up to 1 tb Alarm 02In & 01 Out,2-Way Full Duplex Audio,ONVIF Profile S, G, T & M,IP66/67 & IK10,FCC PART 15B, EN 55032CE (EN 50130-4)UL 62368-1, EN 62368-1 CE (EN 63000) Etc as required (Approve Make: Bosch, Honeywell, Axis, Pelco )) 450 Supply, of survelince 4 tb hard disk Performance class 5400 RPM Load/unload cycles 300,000,Annualized workload rating 360TB/yr 451 Supplying, Installation and Testing and Commissioning of Client Workstation a) Processor - Intel Core 17-10700K or latest CPU (Intel Quick Sync Supported) b) Memory -- Minimum 16 G c) Hard disks - 500GB SSD Disk (d) OS- Windows e) Network Card - 1Gbps network card f) 4GB Graphics with 2 display support @4k resolution etc. complete as required.(Make - Dell/IBM/HP) 452 DG Set (Comprehensive Maintenance) Comprehensive maintenance of DG sets of various capacity complete with alternator AMF panel & battery chargers including carrying out the periodic maintenance as per schedule i/c installation and fixing ofB-Check Kit, Oil, Coolant,Air Filter etc.including cartage charges and cost of B-Check kit as indicated in item given below complete i/c attending complaints during any breakdown /fault and rectify the same immediately for healty functionality of DG Set etc as required. (The Work shall be carried out Only by OEM of respective DG Set or their Authorized Service Agent) a. B-Check KITb. Inhibitor Corrorion /Coolentc. Element Air Cleanerd. Gasket, Rocker Lever Cover e. Valvoline /Petronas Urania Engine Oilof required quantityf. Element CRN Resisterg. Element bypass filterh. Separator fuel water i. Element Lub. Oil Filter, Fuel Filterj. Air Filter 453 2000 KVA HTDG sets. (05nos.) Make - CumminsSEPARATOR,FUEL WATER - 03 nos/ for each DG set 454 FILTER,LUBRICATING OIL - 04 nos/ for each DG set 455 RESISTOR,CORROSION - 02 nos./ for each DG set 456 ELEMENT, AIR CLEANER - 4 nos./ for each DG set 457 INHIBITOR,CORROSION - 10 nos./each DG set 458 FOIL SEALED TEST STRIPS CC2602B - 01 nos./ for each DG set 459 VALVOLINE PREMIUM BLUE 7800 PLUS 1/210 LTR - 400L/ for each DG set 460 CLEAN MASTER ENGINE AND GENSET PARTS CLEANER - 02 nos./for each DG set 461 RUST GUARDIAN INSTANT RUST FIGHTER - 02nos./ for each DG set 462 HAND CLEANX WATERLESS INDUSTRIAL HAND CLEANER - 01nos./ for each DG Set 463 FREIGHT CHARGES - 01nos./ for each DG set 464 AMC FOR 2000 KVA FOR 5 NO. DG SET 465 1010KVA HT DG sets (02nos.) Make - Cummins for B-Check 466 SEPARATOR, FUEL WATER - 02 nos./ for each DG set 467 ELEMENT, OIL BYPASS FILTER - 02 nos./ for each DG set 468 ELEMENT, LUB OIL FILTER- 04nos./ for each DG set 469 INHIBITOR, CORROSION 5 LITERS -01nos./ for each DG set 470 CLEAN MASTER ENGINE AND GENSET PARTS CLEANER - 03nos./ for each DG set 471 KIT AIR CLEANER ELEMENTS (K, QSK, V SERIES) - 02 nos./ for each DG set 472 STRIP TEST -01 nos./ for each DG set 473 VALVOLINE PREMIUM BLUE 7800 PLUS 1/210 LTR - 175L/ for each DG set 474 RUST GUARDIAN INSTANT RUST FIGHTER -03nos./ for each DG set 475 HAND CLEANX WATERLESS INDUSTRIAL HAND CLEANER-01 nos./ for each DG set 476 FREIGHT CHARGES 477 AMC FOR 1010 KVA FOR 2 NO. DG SET 478 500KVA LT DG sets (02nos.) Make - Cummins 479 B CHECK KIT FOR CPCB-II, KTAA19, WITHOUT TEST STRIPS -01nos./ For each DG set 480 KIT AIR CLEANER ELEMENTS (K, QSK, V SERIES) -01nos./ For each DG set 481 INHIBITOR,CORROSION - 02nos./ for each DG set 482 FOIL SEALED TEST STRIPS CC2602B -01nos./ For each DG set 483 VALVOLINE PREMIUM BLUE 7800 PLUS 1/55 LTR - 55L/for each DG set 484 CLEAN MASTER ENGINE AND GENSET PARTS CLEANER -01nos./ For each DG set 485 FREIGHT CHARGES -01nos./ For each DG set 486 AMC FOR 500 KVA FOR 2 NO. DG SET 487 250 KVA LT DG sets (02nos.)Make - Cummins 488 B CHECK KIT FOR CPCB-II, KTAA19, WITHOUT TEST STRIPS -01nos./ For each DG set 489 KIT AIR CLEANER ELEMENTS (K, QSK, V SERIES) -01nos./ For each DG set 490 INHIBITOR,CORROSION - 02nos./ for each DG set 491 FOIL SEALED TEST STRIPS CC2602B -01nos./ For each DG set 492 VALVOLINE PREMIUM BLUE 7800 PLUS 1/55 LTR - 40L/for each DG set 493 CLEAN MASTER ENGINE AND GENSET PARTS CLEANER -01nos./ For each DG set 494 FREIGHT CHARGES -01nos./ For each DG set 495 AMC FOR 500 KVA FOR 2 NO. DG SET 496 Comprehensive & Maintenance of Centralised & Portable RO System 497 Annual Comprehensive Maintenance of 2 X 3000 LPH centralized RO System complete with motor pumping set i/c carrying out the periodic maintenance as per schedule i/c providing & fixing of difference consumable parts like membrane, sediment flux & Dosing chemical, etc. as required of Ion exchange makefor 24 months 498 Annual repair/services of Portable RO ( Kent crystal star, 20 LPH, 11 litre storage tank) 499 Refilling of fire Extinguishers Installed in the North and South parcel of AIIMS Vijaypur, Jammu 500 Refiling of Fire Extinguisher ABC Type capacity6.0 kg 501 Refiling of Fire Extinguisher Co2 Type capacity 4.5 kg 502 Less credit for following old/dismantled materials(Items Nos 503 to 567 as under). 503 1 run of Cable 504 2 run of Cable 505 Supply of Core Switch with 24 SFP+/SFP ports, 4 QSFP+ ports, 2 expansion slots, redundant fans, 2 AC power supplies, 2 power cords, 4-post rack mount kit,and front to back air ow,Switching capacity: 720 Gbps (unidirectional)/1.44 Tbps(bidirectional),Layer 2/Layer 3 throughput (maximum with 64 byte packets):1,071 Mpps (wire speed),etc as required.Approve Make (Juniper,Cisco, Extreme,Cambium ) 506 Supply of 10g Duplex sfp+ Optical Transceiver with Core size/cladding9/125 µm, Distance up to 10 km, etc as required Approve Make (Juniper,Cisco, Extreme,Cambium) 507 Supply of armoured 6 core Single mode OS2 (9/125 Micro), Corrugated ECCS Armor, HDPE (UV) Sheathing, Theoxtropic gel filled OFC cable with 2 Nos steel music wire embedded in side sheathing as strength member forswitch connectivity. Cable should be ROHS compliant and as per IEC60749-1 with product warranty of 25 years.Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 508 Supply of 6F SM loaded LIU with LC adaptor plates, pigtel cables, Spilce tray, cable holder and 4 nos of cable entry exist point with rubber gurment along with the LIU, Powder Coaded 1.2mm steel sheet metal, 1U etc complete as required. LIU should be in accordance with YD/T 778-2006 Optical Distribution Frame & YD/T 1272.1- 2003 Optical Fiber Connector Part 1: Type LC and should have 25 years of product warranty.Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 509 Supply of LC-LC singlemode OS2 (9/125) duplex, LSZH fiber patch cord for LIU to switch connectivity. Patch Cord should have aramid yarn as strenght member with 1000 time mating cycle. Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 510 Supply of CAT 6A UTP LSZH Cable, 23 AWG solid copper conductors in accordance to TIA/EIA 568 C.2 (Category 6a) & ISO/IEC 11801 2nd ed(Class Ea), UL Approved, tested @500 Mhz, with HDPE insulation of individual conductor and over all Dia of 7.2 mm for Connectivity of Hub room to End Point. Grey ColorApproved Makes:Derwiser/Nexans/Siemon/Systimax/Legrand 511 Supply of CAT 6A UTP Universal (both tool & toolless) information outlet (I/O) in accordance with ANSI TIA 568 C.2, IEC 60603-7-4 2nd Edition, ISO/IEC TR 11801-9901- 2014, ROHS Compliant. The I/O should have minimum 750 mating cycle and 200 insertion cycle, for Data, Voice, & Wi-Fi at user end. Approved Makes:Derwiser/Nexans/Siemon/Systimax/Legrand 512 Supply of CAT 6A UTP, LSZH Patch Cord as per ANSI/TIA/EIA 568C.2 and UL 94-V-0, ROHS Compliant, patch cord 2 Mtr for rack side switch to end user connectivity. Approved Makes: Derwiser/Nexans/Siemon/Systimax/Legrand 513 Supply of 1, 2 and 4 port face plate, British Style with Shutter, 2 Plate system clear finish with transparent labelling, ROHS Compliant, in accorandce with standards like ANSI/TIA-568-C.2, ISO/IEC 11801:2002 AMMD.2:2010, YD/T 926.3-2009 & ISO/IEC 60603-7 white for I/O fixing at user side. Approved Makes:Derwiser/Nexans/Siemon/Systimax/Legrand 514 Supply of 22U wall mount rack with fans , 2 cable managers , satationary shelf , 2 Nos. of hardware pkts.Approved Makes: Der Wiser/MTS/Rittal/APC/APW/Valrack 515 Supply of 4MP MFZ Varifocal Dome Camera With 1/2.8” Progressive Scan CMOS,Maximum Resolution 2592 x 1520, Lens 2.7 ~ 13.5 mm, DC-Iris F1.6 , Minimum Illumination Color 0.006Lux @F2.0,IR Range Smart IR, 60 m, 04 IR LEDs,,Signal-to-Noise Ratio >55 db minimum,Electronic Shutter Range Auto/Manual, 1/3 ~ 1/100,000,Dynamic Range 140 db minimum,Back light compensation BLC, HLC, WDR,3D Noise Reduction, Inbuilt Analytics Smart Motion Detection, Tampering, Intrusion, Multi Loitering, People Counter, Tripwire, Abandoned object, missing object, audio detection,4 configurable windows,8 Region of Intrest, Compression,3D digital noise reduction (ON/OFF) color, brightness, sharpness, contrast, white balance, exposure control, backlight compensation/WDR, Local Storage up to 1 tb Alarm 02In & 01 Out,2-Way Full Duplex Audio,ONVIF Profile S, G, T & M,IP66/67 & IK10,FCC PART 15B, EN 55032CE (EN 50130-4)UL 62368-1, EN 62368-1 CE (EN 63000) Etc as required (Approve Make: Bosch, Honeywell, Axis, Pelco )) 516 Supply, of survelince 4 tb hard disk Performance class 5400 RPM Load/unload cycles 300,000,Annualized workload rating 360TB/yr 517 Supplying, Installation and Testing and Commissioning of Client Workstation a) Processor - Intel Core 17-10700K or latest CPU (Intel Quick Sync Supported) b) Memory -- Minimum 16 G c) Hard disks - 500GB SSD Disk (d) OS- Windows e) Network Card - 1Gbps network card f) 4GB Graphics with 2 display support @4k resolution etc. complete as required.(Make - Dell/IBM/HP) 518 DG Set (Comprehensive Maintenance) Comprehensive maintenance of DG sets of various capacity complete with alternator AMF panel & battery chargers including carrying out the periodic maintenance as per schedule i/c installation and fixing ofB-Check Kit, Oil, Coolant,Air Filter etc.including cartage charges and cost of B-Check kit as indicated in item given below complete i/c attending complaints during any breakdown /fault and rectify the same immediately for healty functionality of DG Set etc as required. (The Work shall be carried out Only by OEM of respective DG Set or their Authorized Service Agent) a. B-Check KITb. Inhibitor Corrorion /Coolentc. Element Air Cleanerd. Gasket, Rocker Lever Cover e. Valvoline /Petronas Urania Engine Oilof required quantityf. Element CRN Resisterg. Element bypass filterh. Separator fuel water i. Element Lub. Oil Filter, Fuel Filterj. Air Filter 519 2000 KVA HTDG sets. (05nos.) Make - CumminsSEPARATOR,FUEL WATER - 03 nos/ for each DG set 520 FILTER,LUBRICATING OIL - 04 nos/ for each DG set 521 RESISTOR,CORROSION - 02 nos./ for each DG set 522 ELEMENT, AIR CLEANER - 4 nos./ for each DG set 523 INHIBITOR,CORROSION - 10 nos./each DG set 524 FOIL SEALED TEST STRIPS CC2602B - 01 nos./ for each DG set 525 VALVOLINE PREMIUM BLUE 7800 PLUS 1/210 LTR - 400L/ for each DG set 526 CLEAN MASTER ENGINE AND GENSET PARTS CLEANER - 02 nos./for each DG set 527 6 amps. to 32 amps. ratings, SPMCB 528 6 amps. to 32 amps. ratings, SPNMCB 529 6 amps. to 32 amps. ratings, DPMCB 530 AMC FOR 2000 KVA FOR 5 NO. DG SET 531 100 A, TPMCCB 532 125 A, TPMCCB 533 150 A/160A, TPMCCB 534 250 A, TPMCCB 535 125 A, FPMCCB 536 200 A, FPMCCB 537 250 A, FPMCCB 538 400 A, FPMCCB 539 VALVOLINE PREMIUM BLUE 7800 PLUS 1/210 LTR - 175L/ for each DG set 540 RUST GUARDIAN INSTANT RUST FIGHTER -03nos./ for each DG set 541 HAND CLEANX WATERLESS INDUSTRIAL HAND CLEANER-01 nos./ for each DG set 542 FREIGHT CHARGES 543 40 amps. ratings, SPN MCB 544 63 A ratings, SPN MCB 545 63 A ratings, TPN MCB 546 1.5 sqmm. single core copper/Al conductor cable 547 4.0 sqmm. single core copper/Al conductor cable 548 6.0 sqmm. single core copper/Al conductor cable 549 10.0 sqmm. single core copper/Al conductor cable 550 16.0 sqmm. single core copper/Al conductor cable 551 FREIGHT CHARGES -01nos./ For each DG set 552 AMC FOR 500 KVA FOR 2 NO. DG SET 553 250 KVA LT DG sets (02nos.)Make - Cummins 554 B CHECK KIT FOR CPCB-II, KTAA19, WITHOUT TEST STRIPS -01nos./ For each DG set 555 KIT AIR CLEANER ELEMENTS (K, QSK, V SERIES) -01nos./ For each DG set 556 INHIBITOR,CORROSION - 02nos./ for each DG set 557 FOIL SEALED TEST STRIPS CC2602B -01nos./ For each DG set 558 VALVOLINE PREMIUM BLUE 7800 PLUS 1/55 LTR - 40L/for each DG set 559 CLEAN MASTER ENGINE AND GENSET PARTS CLEANER -01nos./ For each DG set 560 1200 mm sweep BLDC/ old ceiling fan 561 Batten fitting (4 Ft) 562 Batten fitting (Upto 2 Ft) 563 Surface mounting downlight fitting 564 Bulkhead fitting 565 Wall bracket Fitting 566 300 mm sweep, exhaust fan 567 Fresh air-fan (Upto 250 mm sweep)

Key Value

Document Fees
Refer document
EMD
INR 4634600.0 /-
Tender Value
INR 36.34 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail