}

Tender For Repair Maintenance Of Oh Lines Gods La And Other Connected Works At Vaious Locations At Af Stn Singarsi Under Age I Af Singarsi, Shillong-Meghalaya

Military Engineer Services has published Tender For Repair Maintenance Of Oh Lines Gods La And Other Connected Works At Vaious Locations At Af Stn Singarsi Under Age I Af Singarsi. Submission Date for this Tender is 04-08-2025. Overhead Line Tenders in Shillong Meghalaya. Bidders can get complete Tender details and download the document.




Tender Notice

50162291
Tender For Repair Maintenance Of Oh Lines Gods La And Other Connected Works At Vaious Locations At Af Stn Singarsi Under Age I Af Singarsi
Tender
Indian
Meghalaya
Shillong
04-08-2025

Tender Documents

Tender Details

Tender For Repair Maintenance Of Oh Lines Gods La And Other Connected Works At Vaious Locations At Af Stn Singarsi Under Age I Af Singarsi; 1 Supply and fixing in repair for steel tubular swaged pole complete with cast iron base plate, finial taper plug, bolts, nuts & screws as specified type 410 SP 55, 11 metres long including two coats of aluminium paint over a coat of red oxide primer after preparation of surfacesincluding taking out old damaged pole complete all as specified and as directed. Note: Excavation, filling, and foundation concrete will be measured paid separately. 2 Supply and fix in repair HT 33 KV out door type gang operated air-break switch suitable for horizontalmounting motorised along with opening/closing paneltype complete with 9 insulators and with earth switch upto 200/400 Amps 3 Supply , fixing and testing post top insulator in three series including necessary connection with 33 KV distribution system completeall as specified. Note : Each insulator of 3 series shall be of 33 KV rating. 4 Supply , fixing and testing disc type insulator in three series including necessary connection with 33 KV distribution system completeall as specified. Note : Each insulator of 3 series shall be of 33 KV rating. 5 Supply and fixing in replacement ofswitch air break, HT11 KV gang operated vertical/horizontal type triple pole mechanically operated, mounted on 09 insulator and steel frame, with operating mechanism worked from ground level, for current rating upto 400 amps as per IS-9921 includingtaking down old unserviceable GOD complete all as specified and directed 6 M&L for GI cable route indicator of total height 1.2 m duly written HT CABLE on oval plate to be fixed with PCC with 150 mm depth in ground complete all as specified and as directed by Engrs-In-Charge.Note: Cost of PCC for fixing of route indicator to be catered in this item rate 7 M&L in repair and servicing / overhauling of 33 KV HT OCB installed at 33 KV MRSincludng repair / replacement of old damaged contactor, push button,contact lever, bush, sealing etc all complete to make the 33 KV HT OCB fully functionalall complete all as directed by Engineer- in- Charge .Note : Oil to be use for TOP UP shall be included in quoted rates and any other items left out but required to make OCB fullly functional shall be included in quoted rate 8 M&L for replacementResin cast current transformer outdoor type of ratio 100-50/5A, class 1.0, 5P10 , burden :15 VA,shall be matching with the existingmake of 33 KV OCB or as approved byEngr- in-charge. 9 M&L for replacmentof Potential Transformer from 33 KV MOCB outdoor type ratio 33000/110 volt, 200 VA, Cl 1, 36 HSV KV, 70/170 IL KV, 50 Hz ftestingcompletewithload testing as specifiedby Engr-in-Charge. 10 Supply only Control wiring with size of 2.5 sqmm 8 core, PVC coppercable for indicating lamp , control protection system etc suitable for 33KV shall be matching with the existingmake of 33 KV OCB or as approved byEngr- in-charge. 11 Supply and fixing in replacement of lighting arresterexpulsion type suitable for 33 KV complete with all fitting transmission class, discharge capacity of 65 KAincluding taking down old unserviceable switchescomplete, all as specified & directed by Engr-in-charge. 12 Supply and fixing in replacement of lighting arresterexpulsion type suitable for 11 KV complete with all fitting transmission class, discharge capacity of 65 KAincluding taking down old unserviceable switchescomplete, all as specified & directed by Engr-in-charge. 13 M&L Air break (switch) insulator for 33000 voltssuitable for current rating 600 amps all complete all as directed by Engr-in-Charge 14 M&L Air break (switch) insulator for 11000 voltssuitable for current rating 200 amps all complete all as directed by Engr-in-Charge 15 Supply and fixing in replacement cross arms, bracings, supports, clamps, back plate fabricated from structural steel sections such as channels, angles, flat iron including 16mm dia bolts, nuts, washers, welding, bending, cold or hot drilling holes for bolts/insulators in any shape and size as directed and inclusive of one priming coat of red oxide zinc chrome, one under coat and one finishing coat of aluminium paintcomplete including taking down old unserviceable cross arms complete all as specified and directed by Engineer-in-Charge. 16 M&L in repair of 11 KV HT Change over 400 amp for proper change over of HT electc supply including complete servicing, repair / replacement of old damaged gear, change over handle, push button, pinen, contact lever, bush, sealing etc all complete to make the HT Change over proper functioning all complete all as directed by Engineer- in- Charge 17 M&L Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelledwhite, with letters, figures andconventional skull and bones insignal red colour and fixed withM.S. clamps, bolts and nuts ofapproved size, for LT, 20x15cmsize all complete 18 Supplying and laying HDPE pipes (ISI marked) 100mm bore with connecting accessories, laid under road/ drain/fixed on wall etc forprotection of HT cables complete all as specified and as directed 19 M&L for repair of LT and HT Panels by required welding, cutting, grinding, revetting with proper arrangement for door opening, hinges, providng proper insulation and colour coding for bus bar, cable entry and exit through cable glandincludingapplying two coats of synthetic enamel paintof suitable for existing matching colour by sprayingincluding preparation of old surfaces, removing & cleaning of oil/greasing complete all as specified and as directed. 20 Supply, fixing , 33 KV (yard) power grid bus bar structure at MRS 33/11 KV alongwith connecting hollowaluminium bus tube of 40 mm nominaldia as per IPS 40 mm for 33 KV operating voltage and of current carryingcapcity 400Ampsincluding necessary connections with electrical equipment/ system by means of bolts, nuts, check nuts, washers clamps , expansion jointsand painting with insulated paint of R.Y.Bcolour coding etc and testing complete all as directed by the Engr-in-Change.Note: Nut bolts, grease, jumper, lugs. painting etc shall be included in quoted rates. 21 Surface dressing not exc. 15cm deep in soft/loose soil and cleaning away all grass vegetation, saplings, shrubs, brushwood, undergrowth roots, and trees not exc. 30cm girth in surrounding of transformers, LT panels, 02/04 pole structures etc. at various sub-stn/ E/M installations and removing rubbish upto a distance exc. 200m but n.exc. 250m outside of periphery of the area under clearance complete all as directed by the Engr-in-Charge. 22 Supply and fix cable joint kit for 11 KV grade cable for outdoor termination, heatshrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size95 sqmm all as specified and directed by EIC. 23 Supply and fix cable joint kit for 11 KV grade cable for indoor termination, heatshrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size95 sqmm all as specified and directed by EIC. 24 M&L for straight throughheat shrinkcable jointing kit for 11KV ( Earthed ) grade cable for type joint completewith jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm complete all as specified and directed by Engineer-in-Charge. 25 Supply, spread & levelling aggregate of guage/ size 40 to 80 mm size around the transformer, HT two pole structure, HT four pole strcture etc in the existing33 KV MRS including clearing and cutting of vegetation, prunning of trees all complete. 26 Supply and layingin replacement of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured electric power cable (heavy duty) with aluminium conductor(multistranded), 95 Sqmm 3 core , 11000 volts grade connected with suitable size brass cable gland and aluminium lugs of required size,laid in trenches or passing through pipes including testing after laying, including taking up old unserviceable cable complete of following size all as specified and directed by Engineer-in-Charge. 27 Supply and laying in replacement of un-reinforced precast concrete cable cover, class HV, type 1 with peak, size 300mm x 180mm x 40 mmincluding taking down old unserviceable cable cover complete all as specified and directed by Engineer-in-Charge. 28 M & L road cutting of size (30x45) cm width and depth 30 cm width 45 cm depth for laying of cables incl making good the road with necessaryreturning filling and bituminious portion with concret and bituminious mixture and cemented portion with PCC in 1:2:4 , 15 cm thick from top and matching the surfaces with existingall as directed. 29 Excavationintrenchesnotexceeding1.5 M wideandnotexceeding1.5 Mindepthandgettingoutin soft/loose soilor hard/densesoilfortakingup orlaying ofcableallasspecifiedanddirected. 30 Supply and layingdry riversand laidintrenches 8cm below the cable and 15cm above the cable and punned to 18cmascablecushioningandcoveringcomplete all as specified and directed by Engineer-in-Charge.Note:- Punned quantity will be measured paid at this item. 31 Removing excavatedmaterialnotexceeding50 Manddepositingwheredirectedatalevelnotexceeding 1.5 Mabovestartingpoint all as specified and directed by Engineer-in-Charge.. 32 Returning, filling inincludingspreading, leveling, wateringandwellramminginlayersnotexceeding25 cm in soft /loose soil or hard/dense soil all as specified and directed by Engineer-in-Charge. . 33 M&L PCC 1:4:8type D 2 (using 40mm gradedstone aggregates) as in foundation of electric poles etc all as specified and directed. 34 M&L PCC 1:2:4 type B 1 (using 20mm graded stone aggregate) as in benching / copping around poles including use of necessary form work complete all as directed. 35 M&L in replacement for Earthing complete with galvanised steel earth plate electrode of size 600x600x6mm thick burried in a pit to a depth of 2.25mtrs below ground level with top edge of earth plate at a depth of not less than 1.50 meters below ground level, earth plate packed on all sides with charcoal dust mixed with salt to a thickness of 15cm, connected with earthing lead of 32mm x 6mmgalvanised iron strip, watering pipe 20mm dia light grade and water filling funnel and mess complete all as shown in plate No 4 of MES Schedule part II to the earthing test point, including PCC Work complete includingprotection pipe 40 mm dia light gradeall as specified and directed by Engr-in-Charge.(Note :- The earth strip/lead up to 7.5 m shall be deemed to be included quoted unit rate.) 36 Materials and Labour for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required for 32X6 galvanised iron strip using porcelain clit/post insulators,including brazing if required complete all as specified and directed. 37 Schedule of Credit

Key Value

Document Fees
INR 500 /-
EMD
INR 38000.0 /-
Tender Value
INR 18.90 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail