Regarding Inviting Quotations For Preparing Price Lists Of Various Types Of Equipment For Implementing Inlet And Outlet Parameters Ocems System In Stp And Etp Within The Area Of Pimpri Chinchwad Municipal Corporation- Regarding inviting quotations for preparing price lists of various types of equipment for implementing inlet and outlet parameters OCEMS system in S.T.P. and E.T.P. within the area of Pimpri Chinchwad Municipal Corporation. 2 PLC - Supply, installation, testing, and commissioning of a PLC Panel equipped with a 7 HMI for monitoring ofWater Quality parameters and required communication interface, SCADA interfaces, telemetry interfaces,hardwares, controls, cables and all required accessories tocommunicate with all field instruments i.e Analytical instruments ( pH,BOD,COD,TSS, Ammonical Nitrogen, Total Nitrogen).The panel shall be an outdoor-type.The PLC Shall be Compatible with Siemens TIA portal for data interfacing. The PLC should be able send data to centralised SCADA and should send data to local PC (local plant scada) to display data etc., complete and as per the directions of Engineer-in-charge - Detailed Quotation Notice Attached 3 Scada Software - Supply, installation, testing and commissioning of SCADA Software (SCADA Screen Development) etc., complete and as per the directions of Engineer-in-charge - Detailed Quotation Notice Attached 4 Cetralized Computer Station - Supply, installation, testing and commissioning ofSewerage Water Command and Control Centreincluding Centralized Computer Station etc.,complete and as per the directions of Engineer-incharge -Detailed Quotation Notice Attached 5 Maintenance free chemical Earthing system - Supply, installation, testing and commissioning of maintenance free chemical Earthing system with copper rod of sufficient length not less than 2 Meter etc. complete and as per the directions of Engineer-in-charge. The rate is inclusive of all but excluding GST - Detailed Quotation Notice Attached 6 4G LTE Dual SIM Modem - 4G LTE Dual SIM ModemSupplying, installing, testing and commissioning of DUAL SIM GPRS communication modem. It shall be fixed inside PLC based panel with proper connections having equivalent specification and compatible with system in size and performance - Detailed Quotation Notice Attached 7 Sim Card - Updating PLC panel with 4G SIM service without static IP (per month basis) and compatible with system in size and performance to existing panel etc. complete and as per the directions of Engineer-in-charge - Detailed Quotation Notice Attached 8 Real Time Water Quality Monitoring System - Supply, Installation, Commissioning of Real Time Water Quality Monitoring System (RTWQMS) of Physico-chemical parameters, Compatible with latest MPCB and CPCB guidelines.1. pH,2.BOD,3.COD4.TSS5. Ammonical Nitrogen 9 Consumable for Sensors - Supply, Installation, Commissioning of Consumables and spares for reviving preinstalled xylem WTW IQ Sensor Net NH4 (Varion plus AN/N comp SET NH4 & NO3) sensors. Make – Xylem. 10 Consumable for Sensors - Supply, Installation, Commissioning of Consumables and spares for reviving preinstalled xylem WTW IQ Sensor Net pH (Sensolyt SEA) Make – Xylem. 11 Consumable for Sensors - Supply, Installation, Commissioning of Consumables and spares for reviving preinstalled xylem WTW IQ Sensor Net CarboVis® Carbon Sensors rate should include the price of Calibration sleeve. Make – Xylem. 12 Replacement of individual sensor - Supply, Installation, Commissioning of Consumables and spares for reviving preinstalled xylem WTW IQ Sensor Net Sensolyt 700 IQ ( pH sensor) Make – Xylem. 13 Replacement of individual sensor - Supply, Installation, Commissioning of Consumables and spares for reviving preinstalled xylem WTW IQ Sensor Net Ammolyt Plus 700 IQ, Amonical nitrogen sensor. Make -Xylem. 14 Replacement of individual sensor - Supply, Installation, Commissioning of Consumables and spares for reviving preinstalled xylem WTW IQ Sensor Net Carbovis 705 IQ TS sensor ( COD, BOD ,TSS sensor) Make – Xylem. 15 IQ Sensor net Terminal/ Controller - Supply, Installation, Commissioning of IQ Sensor Net Terminal / ControllerMIQ/TC 2020 3G ( only controller / Converter unit) , Make - Xylem 16 Power Supply Module - Supply, Installation, Commissioning of MIQ/PS- Power supply module, Make – Xylem. 17 Analog Output Module - Supply, Installation, Commissioning of MIQ/C6- Analog output module ,Make – Xylem 18 SACIQ Cable - Supply, Installation, Commissioning of Cable for Sensors (SACIQ - 15,0) Make – Xylem. 19 Data Loger - Supply, Installation, Commissioning of Data logger for data transfer to Required location through API , Must have wifi / GSM/ GPRS conectivity, Should be compatible with MIQ/TC 2020 3G (Xylem), Make – Xylem. 20 4 to 20 mA Analog signal splitter - IN 24 VDC / 230 VAC. INPUT: 4-20MAOUTPUT: 4-20MA ( 2 NOS), 4-20MA SIGNAL SPLITTER, 4 to 20 mA analog signal splitter to be installed in panel for provision of giving two 4 to 20 mA anolog signal from single source. 21 Hook Up of automated STP SCADA system - Hooking up of Existing SCADA with centralised SCADA system.:Designing, supplying, installing and commissioning of interfacing software ,hardware, modem, at existing STP to interface the same with central system at Chinchwad SBR. The Exisitng SCADA system is Siemens WinCC TIA portal V20. The details of STP plant SCADA system should be reflected on Centralised SCADA at real time basis. complete as directed by Engineer- incharge and as per detailed specifications 22 SCADA client package (3 client licence) - Supply, integrating, testing and commissioning of SCADA Software client for Siemens WinCC TIA portal Version 20. Three clients package for View only runtime access which will be integrated with centralised main SCADA software installed at Chinchwad SBR STP . These Client Package should be with perpetual licence which will be used for remote monitoring. The rate should include SCADA Screen Development , integration with main scada and required accesories as per the directions of Engineer-in-charge. Make - Siemens 23 Kepware Perpetual licence OPC software - Kepware OPC software should support supports both OPC DA and OPC UA standards. It must offer support to various downloadable device drivers, enabling connectivity with numerous industrial devices and protocols. It should be Windows-based server supporting latest windows edition and upgradable with upcoming updates. Major part of it should offer features like Communications Path Redundancy and Device Pairs Redundancy to eliminate single points of failure and ensure reliable communication.OPC UA must provide secure communication using SSL/TLS encryption and digital certificates, ensuring secure data exchange between devices.Proposed OPC Connectivity Suite should allow server to manage data from different OPC standards (DA, UA, and XML-DA) from a single instance.It should fulfil objective of Scalable unified architecture, providing the flexibility to combine drivers and consume multiple protocols in a single server. The license provided should be perpetual and has no expiry with unlimited support from supplier. 24 Modbus Module - Supply, Installation, Commissioning of MIQ/MOD 3- Modbus Module , Make - Xylem