Upgradation Work On Turnkey Basis At Timber Pond Area Including O .M At Shalimar, Howrah -- 1 UP-GRADATION WORK (CIVIL) TIMBER POND 2 Detailed survey,Design, Drawing & Detailing as mentioned below :a. GA drawing i)Architectural drawing and detailing for Civil structures, if requiredb. All short of Civil drawing incl. structuraldetailingc.Detailed survey of adjacent area with Auto Level &Total Stationd. As-built drawing (All drawing should be submitted both in hard and soft copies along with PDF & Auto Cad files) 3 Detailed Soil investigation:Soil investigation consisting with subgrade CBR, soil characteristics, index property of soil, permeability, proctor test, field compaction test, Sub soil exploration of 150mm dia conducting standard penetration test as per IS 2131-1981(minimum 3 bore hole) with in the proposed Land of Timber pond 4 Health Study of the existing Dry Dock including Survey, Preliminary Health Audit Report and Detail Health Audit Report. ( 40% payment will be released on completion of preliminary Study and Survey including submission of Preliminary Health Audit Report to engaging Dept. and remaining 60% payment will be released after stisfactory completion of Details study including submission of Detail Health Audit Report along with subsequent test report and plan/drawings to engaging dept.) 5 Yard Maintenance Service (O & M): For Dressing, cleaning and cutting of vegetations, shrubs or bushes of the entire area within the boundary at periodic interval or as when required.Keep the dry dock mud free, dewatering including required temporary pumping arrangement and the dock keep dry.Note:The details scope under this item as per SOTR Cl. No. 2.3 6 2 high-skilled electricians round the clock for operation and maintenance of the Electrical Substation (06nos X 12months)Note:The details scope under this item as per SOTR Cl. No. 2.3 7 2 semi-skilled operators round the clock for water and fire main system throughout the yard which also includes pump operation (06nos X 12months) Note:The details scope under this item as per SOTR Cl. No. 2.3 8 2 housekeeping staff (unskilled) for general cleanliness of the yard, offices and stores (02nos X 12months)Note:The details scope under this item as per SOTR Cl. No. 2.3 9 2 High-Skilled Security personnel at a time for perimeter security includingthe waterfront round the clock i.e. in 3 (three) shift (06nos X 18months) Note:The details scope under this item as per SOTR Cl. No. 2.4 10 Supplying at site composite geotextile bags of size 1.00 m x 0.70 mcomprising UV stabilized needle punched 200 gsm polypropylene nonwoven geotextile as inner liner and 300 gsm UV stabilized woven polypropylene geotextile as outer liner as per specification, double stitched at two ends with polypropylene or equivalent yarn including cost of transportation by all means and other incidental charges complete. 11 Labour charges for filling Geo-textile bags with filler materials (sand), machine stitching the open end of the bag with thread as per design and placing the same on slope or dumping from bank within initial lead of 150m and all lifts including carriage and hire charges of all materials and equipments but excluding the cost of filler materials as directed by the Engineer-in-Charge. i) Bag size 1.00m x 0.70m of capacity 0.1325 cum/bag 12 Supply of Silver sand at site for filler of Geo-textile bags 13 Surface Dressing of the ground in any kind of soil including removing vegetation inequalities not exceeding 15 cm depth and disposal of the rubbish within a lead upto 75 m as directed 14 Clearing compound premises of shurbs, plants, jungles etc.by cutting and removing as directed (Specific permission of Engineer-in-Charge prior to execution will be necessary) 15 Dismantaling all types of masonry excepting cement concrete plain or reinforced, stacking serviceable materials at site and removing rubbish as directed within GRSE Premises. 16 Dismantling all types of plain cement concrete works, stacking serviceable materials at site and removing rubbish as directed within a lead of 75 m. 17 Dismantling R.C. floor, roof, beams etc. including cutting rods and removing rubbish as directed including stacking of steel bars 18 Removal of rubbish,earth etc. from the working site and disposal of the same beyond the compound, in conformity with the Municipal / Corporation Rules for such disposal, loading into truck and cleaning the site in all respect as per direction of Engineer in charge 19 Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). (a) Small plant of girth of exposed stem upto 75 mm. lift upto 6 mtr. 20 Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). b) Medium size plant of girth of exposed stem above 75 mm.but not exceeding 150 mm. lift upto 6 mtr. 21 Uprooting and removing plants from the surface of walls parapet etc and making good damages. (Repairing of damages to be paid separately). C)Large plant of girth of exposed stem above 150 mm. but not exceeding 225 mm. lift upto 6 mtr 22 Earth work in excavation including cleaning away vegetation, surbs, etc. if any, for foundation, trenches, drains in earth, soil of all types (ordinary /hard soil) in both dry and wet conditions, sand, graveland soft murum, including dewatering, dressing of sides and ramming of bottom and remonal of excess earth/soiletc. all complete as specified and as directed.(Mode of measurement shall be nett as per drawing). 23 Earth work in filling in foundation trenches or plinth with good earth, in layers not exceeding 150 mm. including watering and ramming etc. layer by layer complete. (Payment to be made on the basis of measurement of finished quantity of work)a) With earth obtained from excavation of foundation. 24 Suplying and laying Single Brick Flat Soling of picked jhama bricks including ramming and dressing bed to proper level and filling joints with local sand. 25 Filling in foundation or plinth by silver sand in layers not exceeding 150 mm as directed and consolidating the same by thorough saturation with water, ramming complete including the cost of supply of sand. (payment to be made on measurement of finished quantity) 26 Supplying and laying Polythene Sheet (150gm / sq.m.) over damp proof course or below flooring or roof terracing or in foundation or in foundation trenches 27 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes. 28 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (6mm nominal size) excluding shuttering and reinforcement,if any, in gound floor as perrelevant IS codes. 29 Supplying tor steel reinforcement (of approved manufacturer) of tested quality of any diameter upto 32mm dia Fe 500 confirming to IS:1786 for reinforced concrete work in all sorts of structures at all depth and height including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge black annealed wire at every intersection, complete as per drawing and direction. 30 Ordinary Cement concrete (mix 1:1.5:3) with graded stone chips (20 mm nominal size) excluding shuttering and reinforcement if any, in ground floor as per relevant IS codes. 31 Supplying ready mixed concrete of M 25 Grade with well graded stone chips of 20 mm nominal size containing designed quantity of cement per Cu.m of wet concrete produced in computerised batching plant under controlled condition using approved super plastisizer, designing concrete mix following I.S. 10262 and I.S. 456, transporting the mix with agitation in transit mixer to work site depositing the mix on a platform erected for the purpose at requiredlevels of concreting and then placing the mix in its final location of form work, compacting and curing the same complete as per specification & direction of the Engineer-in-charge including computerised batching plant transit mixer with all accessories vibrators etc. In foundation & Superstructure with approved Pump 32 Hire and labour charges for waterproof steel/plyboard shuttering of any shape 33 Extra for staging beyond 4 m in any floor (Mode of measurement: area in plan x mean height of staging upto soffit of shuttering above initial 4 m) 34 Rendering the Surface of walls and ceiling with White Cement base WATER PROOF wall putty of approved make & brand.(1.5 mm thick) 35 Brick work with 1st class bricks in cement mortar (1:4) in Foundation 36 Brick work with 1st class bricks in cement mortar (1:4) in Superstructure 37 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) 38 Plasterwith sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary .[including cost of chipping over concrete surface if requiredWith 1:4 cement mortar , 20 mm thick plaster 39 Plasterwith sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary .[including cost of chipping over concrete surface if requiredWith 1:4 cement mortar , 15 mm thick plaster 40 Plaster with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary [including cost of chipping over concrete surface] With 1:4 cement mortar , 10 mm thick plaster 41 Neat cement punning about 1.5mm thick in wall, dado, window sill, floor etc 42 Applying One Coat Exterior grade Acrylic primer of approved quality and brand on plastered or cencrete surface old or new surface, ,including scaffolding / staging where necessary 43 Protective and Decorative Acrylic exterior emulsion paint of approved quality(Two Coat)Super Protective 100% Acrylic Emulsion.,,including scaffolding/staging where necessary 44 Priming one coat on timber or steel or other metal surface with synthetic oil bound primer of approved quality including scaffolding, smoothening surfaces by sand papering etc. 45 Two coat Painting with best quality synthetic enamel paint of approved make and brand on steel or other metal surface including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary 46 Applying Interior grade Acrylic Primer of approved quality and brand on plastered or cencrete surface old or new surface (a) One Coat i) Water based interior grade Acrylic Primer ,including scaffolding/staging where necessary 47 Applying Acrylic Emulsion Paint of approved make and brand on walls and ceilingii),including scaffolding/staging where necessary (Two coats) 48 Supplying fitting and fixing 600 mm ( ±30 mm) diametre R.B.T (Reinforced Barbed Tape) Concertina fencing on wall top using concertina coils stretched to approx.6 meters length at site clipped with two nos. of horizontal R.B.T strands which will be tensioned and fixed with the vertical M.S angle iron posts by means of security fasteners (such as C clips, R.B.T clips etc 49 Drum Sheet Walling 1.40m (av.) high on Sal-bullah /Eucalyptus bullah piling 10 cm dia. and 3.25m long driven 1.75m (av.) below G.L. and 75cm centre to centre including fitting fixing 3 nos. of half bullah pieces (from 10 cm dia) and drum(empty bitumen) sheet (approved condition) of height 1.5m , cutting and straightening drum sheet (each joint must have lap length of min.50mm) including cost of necessary nails, bolts, nuts etc. and providing 2 to 3m long half bullah ties of 10cm dia. @ 2.25 m centre to centre fixed with 10 cm dia. bullah posts driven 1.5m below G.L. including cost of all materials and one coat of coal tarring to all bullah etc. complete as per direction.(i) Using Eucalyptus bullah 50 Supplying and laying true to line and level Double Charge Vitrified Tiles of approved brand conforming to IS 15622: 2006 (Group B I a) and tested as per IS 13630:2006 (relevant parts) [Non-modular sizes for tiles with Water Absorption (av.) ≤ 0.08 %] in floor, skirting etc. using polymerised adhesive of 6mm thick layer applied directly over finished artificial stone floor/Mosaic etc without any backing course and joints grouted with admixture of white epoxy grout materials of approved brand including spacer -2mm as directed and removal of wax coating of top surface of tiles with warm water and polishing the tiles using soft and dry cloth upto mirror finish complete including the cost of materials,Iabour and all other incidental charges complete as per direction of Engineerin- Charge. 51 80 mm thick interlocking designer concrete paver block M-40 grade for hightraffic zone, bus terminus, industrial complex, mandi houses etc. as per IS: 156582006 (over 20-40 mm medium sand bed on 250mm thk WBM/ WMM base course & 250 mm thk bound gnaular/ granular sub-base course & filling the interstices of blocks with fine sand by brooming & subsequent watering including cost of sand for sand bed but excluding cost of base, sub-base course & subgrade preparation.) complete as per direction of Engineer-in-Charge 52 Supplying, spreading and consolidating an uniform and homogeneous mixture of Stone Dust and Sand (mixed in proportion of 3 : 1 by volume and by any approved method as per direction of Engineer-in- Charge) to the required thickness in layers at 97% Proctor Density (not less than 1.7 gm/cc) with powerroller to proper gradient and camber, including watering as necessary, lighting, guarding, barricading and making adequate earthen bundh where necessary to protect the edges and curing with water for 2 to 3 days, mending cracks and depressions by rolling where necessary complete as per Specification including all incidental charges of roller, cost of fuel & lubricants.The compaction factor is 0.67.Note: Rolling should also be done before spreading of mixture of stone dust and sand 53 Supplying, fitting & fixing of partly glazed partly panelled or fully glazed single leaf Aluminium swing door of all aluminium sections viz door frame ( top and side frame), shutter( top rail, bottom rail, lock rail, door vertical) , glazing clip made of Aluminium Alloy Extrusions conforming to IS: 733-1983 and IS: 1285-1975, annodized conforming to IS:1868- 1983, fitted with all other accessories viz. EPDM gusket,cleat, angle screws, handle,door stopper. including labour charges for fitting and fixing of aluminium door with door spring,/aluminium hinges, glass / Panel board all complete as per architectural drawings and direction of Engineer-incharge,10-12 Micron thickness Annodizing film colour powder coating 54 Supplying bubble free float glass ( clear)of approved make and brandconforming to IS: 2835-1987; 6mm thick 55 Godrej Hydraulic door closer fitted and fixed complete Heavy type 56 Supplying Godrej mortice lock chromium plated with keys 6 levers including fitting & fixing complete 57 M.S. structural works in columns, beams etc. with simple rolled structural members (e.g. joists, angle, channel, rail section conforming to IS: 226, IS: 808 & SP (6)- 1964,hollow sections (square or rectangularshape) conforming to IS: 806-1968 & IS:1161-1998),tabular sections conforming to IS: 806-1968 & IS: 1161- 1998 connected to one another with bracket, gussets, cleats as per design, direction of Engineer-in-charge complete including cutting to requisite shape and length, fabrication with necessary bolting, metal arc welding conforming to IS: 816- 1969 & IS: 1995 using electrodes of approved make and brand conforming to IS:814- 2004, haulage, hoisting and erection all complete. The rate includes the cost of rolled steel section, consumables such as electrodes, gas and hire charge of all tools and plants and labour required for the work including all incidental chages such as electricity charges, labour insurance charges etc. 58 Supplying , fitting and fixing single skin color coated trapezoidal profile for wall cladding, Roof shall be made of 0.45mm BMT (Base Metal Thickness) 0.50mm TCT ( Total Coated Thickness excluding paint), G550 ( minimum 550 yield strength), of Zincalume metallic coating (IS15965) with high Solar ReflectanceIndex (SRI) value for better cooling as per thermatch technology, 1000-1015mm effective cover width with five major corrugation, 28mm high rib spaced at 203mm c/c with subtle square fluting in the pan and the end rib shall have anti-capillary groove & return leg. The steel sheet shall be fastened with 40 micron zinc coated or 25 micron zinc-tin alloy coated, hex- head, self-drilling screw as per IS 3566-2002 class 3 fastener. The base steel shall be coated with zinc-aluminum alloy Zincalume (AZ150)(i.e,55% Al, 43.4% Zinc, 1.6% Si) minimum of 150g/m2 coating total on both sides, pre-painted with colorbond XRW (exterior roofing, walling) paint system of 35 micron super Durable Polyester paint (SDP) with stable inorganic pigment with no lead contents confirming IS15965. The sheet shall be free from defects and have brand marking of the manufacturer giving product details on the back of the sheet at regular interval confirming genuinity of the material. In Roof, Ridge, valley and Wall with 0.50 mm thick sheet) 59 Supplying bubble free float glass of approved make and brand conforming to IS: 2835-1987. xiii) 12mm thick cleared toughened glass coforming to IS: 2553-1992(Part-II) 60 Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre tocentre, horizontal & vertical tubes joining with cup & lock system with M.S.tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after .The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineer-in-charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding.Note: -Necessary deduction for scaffolding in the existing item if included to be done. 61 Supplying, fitting & fixing UPVC pipes A- Type and fittings conforming to IS:13592-1992 with all necessary clamps nails,bends,tees, trapsas required including making holes in walls, floor etc. cutting trenches in any soil through masonry concrete structures etc if necessary and mending good damages including joining with jointing materails (Spun Yarn, Valamoid/Bitumen/M-Seal etc) complete.UPVC Pipes:110 mm. Dia 62 Anodised aluminium barrel / tower / socket bolt (full covered) of approved manufactured from extruded section conforming to I.S. 204/74 fitted and fixed with cadmium plated screws:75mm long x 10mm dia. bolt. 63 Levelling and Compacting original ground (Sub Grade) by power roller of capacity 80Kn to 100 Kn including filling in depression occour during rolling to obtain the desired dry density 64 Providing, laying, spreading and compacting stone aggregates of specific sizes including spreading in uniform thickness, hand packing, rolling with vibratory roller 8-10 tonnes in stages to proper grade and camber, applying and brooming requisite type of screening / binding materials to fill up the interstices of coarse aggregate, watering , including cost of all materials and hire and labour charges of all men and machinery and compacting to the required density, as per Clause 404 of Specifications for Road & Bridge Works of MoRT&H (5th Revision). Grading-2 Aggregate (53 mm to 22.4 mm@ 1.21cum) Using Stone Screening Type B (11.2 mm@0.24 cum) and binding materialstone dust mixed with grit @0.08cumBy Manual Means 65 MS (IS-2062) Holding down bolt (duly hot dip galvanised) with 100 x 100 x 6 mm plate washer at bottom, MS Insert Plates and packing the hole with cement concrete or cement grout as directed.20 mm dia bolt,450 mm long 66 C.I. sluice valve 150 mm dia. with flanged ends drilled to as per I.S. 1358/62 and having all cast iron components as per I.S. 780/71 solid forged bronze inside screw spindle having ultimate tensile strength not less than 4.72 MT per sq. cm. Spindle nut valve and seat faces of hard wear resisting, manufactured from best quality gunmetal conforming to I.S. 780/71, painted black all over with asphalt base paint tested to 21 kg (hydraulic pressure) per sq. cm., valve opening to anticlockwise direction, fitted and fixed complete. 67 Supply fitting and fixing of Stainless Steel Single Headed Hydrant Valve, 63mm (2 ½ inch) Female instantaneous Coupling, Oblique type, with Gun Metal Blank cap. ISI marked: as per IS: 5290 Coupling size: 63mm Female single outlet type #A# (Flow: 900 LPM at 7kg/cm2). O.D. 200 mm. I.D. 75 mm. Valve body, Bonnet, Stop Valve, Check Nut and Instantaneous Female Outlet is to be made of Stainless Steel Grade 1 of 4 of IS: 3444 Valve Spindle is to be made of SS confirming to IS: 6603. Hand Wheel is to be made of MS confirming to IS: 1030. Washers, Gaskets are to be made of Rubber confirming to IS: 937. Spring is to be made of SS Wire confirming to IS: 6528. Flange is of 4 holes on 160 mm PCD. 68 Writing and block letters/digits painting including logo on the entrance Gatewith approved enamel paint by EIC on metal/plastered/wooden surface in English,Hindi,Bangali (Rate include all charges for completing the work) 69 40 mm. thick damp proof course with cement concrete (1:1.5:3) (with graded stone chips 20 mm nominal size) with water proofing compound of approved brand @ 0.2% weight of cement including cost of materials over two coats of non toxic acrylic polymer modified cementitious waterproofing slurry coat complete [cost of water proofing compound and non toxic paint to be paid seperately) for underground water retaining structures. 70 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile & finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by synthetic adhesive & grout materials etc. In Floor colour decorative area of each tiles above 0.09 SQm With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m 71 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of key stones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouring oxide if required to match the colour of tiles including roughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.In Wall colour decorative area of each tiles above 0.09 SQm With Sand Cement Mortar (1:4) 20 mm thick & 2 mm thick cement slurry at back side of tiles using cement @ 2.91 Kg/Sq.m & joint filling using white cement slurry @ 0.20kg/Sq.m 72 Supplying, fitting & fixing granite tiles 10mm to 12mm. thick in columns, wall, facia etc. with 15 thick [avg] cement mortar (1:2) including making suitable arrangements to hold the stones properly by brass / copper hooks including pointing in cement mortar (1:2) (1 white cement : 2 marble dust) with admixture of pigment matching the stone shades all complete as per direction of the Engineer-in-charge including cost of all materials, labours, scaffolding, staging ,curing and roughening of concrete surface complete. [Using cement slurry at back side of tiles@ 4.4 kg/sq.m & white cement slurry for joint filling @ 1.8 kg/sq.m]Area of each slab upto 0.2 Sq.m 73 Supplying, fitting and fixing Marble Slab/tile of 15 to 18 mm thickness in floor, lobby, stair, landing & treads etc. over 20 mm (av.) thck base of Cement mortar (1:2) laid with whitecement slurry @ 4.4 kg/Sq.m before placing marble & jointed with white cement slurry @ 2.0 kg/Sq.m with necessary pigments including grinding and Granite polishing as perdirection of Engineering -in -Charge in Ground Floor. {White cement and Pigment to be supplied by the Agency](a) With Makrana plain pink / Adranga Pink / Garbh Gulabi /Udaypur Pink / Udaypur green / Black Bhalsana(ii) Area of each slab/tile exceeding 0.3sq.m. but notexceeding 0.6 sq.m. 74 Rendering the surface of walls and ceiling with white cement based wall putty of approved make and brand(1.5mm thick) 75 Acrylic Distemper to interior wall, ceiling with a coat of solvent based interior grade acrylic primer (as per manufacturers specification) including cleaning and smoothning of surface. Two Coats 76 Supplying 1.5mm thick M.S. sheet fitted and fixed on one or both faces of M.S./ W.I. gate etc. with point welding at not more than 150mm apart complete in all respect as per design including cost of all labour and materials 77 M.S.or W.I. Ornamental grill of approved design joints continuously welded with M.S, W.I. Flats and bars of windows, railing etc. fitted and fixed with necessary screws and lugs in ground floor.(i) Grill weighing above 10 Kg./sq.mtr and up to 16 Kg./sq. mtr 78 Wood work in door and window frame fitted and fixed in position completeincluding a protective coat of painting at the contact surface of the frameexluding cost of concrete, Iron Butt Hinges and M.S clamps. (The quantum shouldbe correted upto three decimals). d) Sal : Local 79 Supplying solid flush type doors of commercial quality, the timber frameconsisting of top and bottom rails and side styles of well seasoned timber 65mmwide each and the entire frame fitted with 37.5mm wide battens places both waysin order to make the door of solid core and internal lipping with Garjan orsimilar wood veneers using phenol formaldehyde as glue etc. complete, includingfitting, fixing shutters in position but excluding the cost of hinges and otherfittings in ground floor.a) 35 mm thick shutters (single leaf) 80 Supplying, fitting and fixing fibre reinforced polymer (FRP) Composite doorframe as per approved section with glass fibre reinforced plastic moulded skinsand a special sandwich core, so as to impart monolitaheic composite structure asper approved technology of Department of Science and Technology (DST) tosafisfy IS: 4020 door testing performance criteria..(ii) 66mm x 70mm 81 Supplying, fitting & fixing fibre reinforced polymer (FRP) Composite doorshutters as per approved design with glass fibre reinforced plastic moulded skins and a special sandwich core, so as to impart monolitaheic composite structure as per approved technology of Department of Science and Technology (DST) to satisfy IS:4020 door testing performance criteria. In ground floor.(ii) 25 mm thick 82 Supplying,fitting & fixing of 2-Track / 3-Track Aluminium slidingWindow of all Aluminium sections(including louvered section) viz. window frame (top,bottom & side frame), shutter (top, bottom, side & interlock member) made of aluminium alloy extrusions conforming to IS 733-1983 & IS 1285-1975, annodisedconforming to IS 1868-1983, fitted with all other accessories viz. PVC roller, EPDM gasket, maruti lock, screws etc. including labour charges for fitting & fixing of aluminium 2-track/3-track sliding window with fixing of glass (excluding cost of glass) all complete as per architectural drawings and direction of Engineer-in-charge. 10-12 Micron thickness Annodizing film Natural white 83 Supplying, fitting and fixing M.S. clamps for door and window frame made of flatbent bar, end bifurcated with necessary screws etc. by cement concrete(1:2:4) as per direction. (Cost of concrete will be paid separately)(a) 40mm X 6mm, 250mm Length 84 Iron butt hinges of approved quality fitted and fixed with steel screws, with ISImark (viii) 100mm. X 75mm. X 3.50mm 85 i) Iron hasp bolt of approved quality fitted and fixed complete (oxidised) with16mm dia rod with centre bolt and round fitting. (b) 250mm long 86 Anodised aluminium barrel / tower / socket bolt (full covered) of approvedmanufactured from extruded section conforming to I.S. 204/74 fitted and fixedwith cadmium plated screws: (v) 150mm long x 12mm dia. bolt. 87 Supplying, fitting and fixing Half round channel with or without outlet asrequired set in cement concrete (6:3:1) with jhama chips complete.(Payment of concrete will be paid seperately) (b) White vitreous chinaware 88 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992(A) (i) Single Socketed 3 Meter Length (b) 110 mm 89 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 UPVC P trap(LH,RH),110mm. 90 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992xii) Door Bend (LH) & (RH) (b) 110 mm 91 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 (B) Fittings iv) Door Tee(LH) & (RH) (b) 110 mm 92 Supply of UPVC pipes (B Type) & fittings conforming to IS-13592-1992 UPVC vent cowl,75mm. 93 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line includingall specials. No separate payment will be made for accesories, specials.(b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 15 mm 94 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories,specials viz. socket, bend, tee, union, cross, elbo, nipple,longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes,fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line includingall specials. No separate payment will be made for accesories, specials.(b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 20 mm 95 Supplying, fitting and fixing CPVC (Chlorinated Polyvinyl Chloride) pipes of approved make conforming to IS-15778: 2007 . with all necessary accessories, specials viz. socket, bend, tee, union, cross, elbo, nipple, longscrew, reducing socket, reducing tee, short piece etc.fitted with holder bats clamps, including cutting pipes, fitting, fixing etc. complete in all respect including cost of all necessary fittings as required,jointing materials in any position above ground. (Payment will be made on the centre line measurements of total pipe line includingall specials. No separate payment will be made for accesories, specials.(b) For Concealed Work (i) CPVC Pipes Class-1,SDR-11 25 mm 96 Supplying, fitting and fixing 18 mm thick marble partition slab with chawk doongri marbel square cut, both sides polished with two front corners rounded and edges polished. 97 Supplying, fitting and fixing E.W.C. in white glazed vitreous chinaware of approved make complete in position with necessary bolts, nuts etc. (a) With P trap 98 Supplying, fitting and fixing Closet seat of approved make with lid and C.P. hinges, rubber buffer and brass screws complete. Plastic (hallow type) white 99 Supplying, fitting and fixing 10 litre P.V.C. low-down cistern conforming to I.S. specification with P.V.C. fittings complete,C.I. brackets including two coats of painting to bracket etc. white 100 Supplying P.V.C. water storage tank of approved quality with closed top with lid (Black) - Multilayerd) 2000 litre capacity 101 Supplying, fitting and fixing Flat back urinal (half stall urinal) in white vitreous chinaware of approved make in position with brass screws on 75 mm X 75 mm X 75 mm wooden blocks complete. (ii) 470 mm X 280 mm X 340 mm 102 Supplying, fitting and fixing white vitreous china best quality approved make wash basin with C.I. brackets on 75 mm X 75 mm wooden blocks,C.P. waste fittings of 32 mm dia., one approved quality brass C.P. pillar cock of 15 mm dia., C.P. chain with rubber plug of 30 mm dia., approved quality P.V.C. waste pipe with C.P. nut 32 mm dia., 900 mm long approved quality P.V.C. connection pipe with heavy brass C.P. nut including mending good all damages and painting the brackets with two coats ofapproved paint. (ii) 550 mm X 400 mm size 103 Supplying,fitting and fixing approved brand 32 mm dia.P.V.C. waste pipe,with PVC coupling at one end fitted with necessary clamps.900mm long 104 Supplying,fitting and fixing approved brand P.V.C. CONNECTOR white flexible, with both ends coupling with heavy brass C.P. nut, 15 mm dia.,600mm long 105 Supplying, fitting and fixing dome shaped C.P. waste grating for urinals32mm. 106 Supplying, fitting and fixing Chromium plated stop cock. 107 Supplying, fitting and fixing Chromium plated bib cock. 108 Supplying, fitting and fixing CP pillar cock. 109 Hand Shower(Health Faucet) with 1mtr Fexible Tube with Wall Hook(Equivalent to Code No.573 & Model -ALLIED of Jaquar or similar) 110 Supplying, fitting and fixing shower of approved brand and makeChromium plated overhead Rain shower (Square), size-180x180mmwith revolving joint (Model Code No. F7010501 of CERA or equivalent) 111 Supplying, fitting and fixing complete Bottle waste trap (Heavy Quality) PTMT Bottle trap 32 mm with connecting pipe ( Prayag or equivalent) 112 Supplying, fitting and fixing gunmetal wheel valve of approved brand and make tested to 21 kg per sq. cm. (for water lines only). ,25mm 113 Supplying, fitting and fixing gunmetal wheel valve of approved brand andmake tested to 21 kg per sq. cm. (for water lines only). ,15mm 114 Supplying, fitting and fixing bevelled edged mirror 5.5 mm thick silver redas per I.S. 3438 / 1965 together with brass C.P. hinges. 600x450mm. 115 Supplying, fitting and fixing porcelain soap tray of approved make.,150x150mm. 116 Supplying, fitting and fixing towel rail with two brackets made with aluminium25mm. dia.,450mm long 117 Supplying, fitting and fixing C.I. square jalli ,150mm. 118 Construction of septic tank of different capacities as per approved drawing with 1st class brick work in cement mortar (1:4) including two 560 mm dia. R.C.C. manhole cover(heavy type)of approved make supplied, fitted and fixed in the 100mm thick R.C.C (1:1.5:3) top slab with necessary fittings, 20mm thick cement plaster (4 : 1) with neat cement finish to the internal surfaces and 15 mm thick cement plaster (4 : 1) to outside wall upto 200 mm below G.L floor finished with 25 mm thick grey artificial stone over 100 mm thick R.C.C(1:1.5:3) bottom slab including supplying, fitting and fixing all necessry specials, fittings, S.W. tees, C.I. foot rest etc. including excavationearth in all sorts of soil, shoring, bailing out and pumping out water as necessary, ramming, dressing the bed and fefilling the sides of the tanks with earth, removing spoils, filling up the chamber with clear water, removing foreign materials from thechamber and including constructing attached inspection pit as per approved drawing and connecting all necessary pipes, joints etc. with internal plaster work and artificial stone flooring is to be done with admixture of water proofing compound @ 0.5% byweight of cement with all costs of labour and materials.v) For 100 users With SAIL/TATA/RINL 119 Construction of circular soak well 2.5 metre deep in all types of sandy soils with dry brick work upto 1.6 metre from the bottom having 150 mm intermediate cement brick work (1:4) band all round and cement brick work (1:4) upto 0.90 metre from top with 20mm thick cement plastering (1:4) to inside face upto the depth of cement brick work, 15mm thick cement plaster (1:4) on outer face from top of the well upto G.L. and 6 mm thick cement plaster (1:4) on top of the R.C.C. cover slab including filling bottom 1.00 metre of inside of the well with brick metal (50 mm to 63 mm size) including R.C.C. cover slab of 100 mm thick with cement conc (1:1.5:3) with stone chips with necessary reinforcement and shuttering including one 560 mm dia. R.C.C. manhole cover (heavy type)of approved make supplied, fitted and fixed in the cover slab with necessary fittings, making nacessary arrangements for pipe connections, excavation of well including shoring, dewatering and removing the exess earth from the premises as per direction complete in all respect with all costs of labour and materials.With 250 mm thick dry brick work and 250 mm thick cement brick work (1:6) and 1.00m inside dia. (SAIL/TATA/RINL) 120 Installation of 1 No 250 mm x 150 mm dia Tubewell along with providing, testing and commissioning of Submersible pumpsetLabour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system including hire charges and labour for supplying of suitable dia. Casting pipes upto full depth of tube well with necessary sockets, tools and plants, staging, force pumping set and making necessary arrangements for boring and also cost of withdrawing the casing pipes and lowering pipes, stainers, blind pipes etc. complete. (The casing pipe should have a minimum 50 mm gap in between the outside of the tube well pipe and the casing pipe).a) For depth upto 250 meter for 150 dia. Tube well with top enlargement of 250 mm dia. i) First 50 metre 121 Installation of 1 No 250 mm x 150 mm dia Tubewell along with providing, testing and commissioning of Submersible pumpsetLabour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system including hire charges and labour for supplying of suitable dia. Casting pipes upto full depth of tube well with necessary sockets, tools and plants, staging, force pumping set and making necessary arrangements for boring and also cost of withdrawing the casing pipes and lowering pipes, stainers, blind pipes etc. complete. (The casing pipe should have a minimum 50 mm gap in between the outside of the tube well pipe and the casing pipe).a) For depth upto 250 meter for 150 dia. Tube well with top enlargement of 250 mm dia. ii) Next 50 metre 122 Installation of 1 No 250 mm x 150 mm dia Tubewell along with providing, testing and commissioning of Submersible pumpsetLabour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system including hire charges and labour for supplying of suitable dia. Casting pipes upto full depth of tube well with necessary sockets, tools and plants, staging, force pumping set and making necessary arrangements for boring and also cost of withdrawing the casing pipes and lowering pipes, stainers, blind pipes etc. complete. (The casing pipe should have a minimum 50 mm gap in between the outside of the tube well pipe and the casing pipe).a) For depth upto 250 meter for 150 dia. Tube well with top enlargement of 250 mm dia. iii) Rest 50 metre 123 Installation of 1 No 250 mm x 150 mm dia Tubewell along with providing, testing and commissioning of Submersible pumpsetLabour for boring through any type of soil for sinking tube well of required dia. With top enlargement by rig boring system including hire charges and labour for supplying of suitable dia. Casting pipes upto full depth of tube well with necessary sockets, tools and plants, staging, force pumping set and making necessary arrangements for boring and also cost of withdrawing the casing pipes and lowering pipes, stainers, blind pipes etc. complete. (The casing pipe should have a minimum 50 mm gap in between the outside of the tube well pipe and the casing pipe).a) For depth upto 250 meter for 150 dia. Tube well with top enlargement of 250 mm dia. iv) For additional depth beyond 150 m 124 Supplying, fibre glass reinforced Epoxy resin slotted of 1 mm slot width in 6.1m length of approved make and as per direction of the Engineer - in - Charge. 150 mm dia.6.0 mm wall thickness 125 Supplying, fitting & fixing heavy type bell mouth PVC reducing socket. 200 mm X 250 mm 126 Supplying, fitting and fixing G.I. cap at top. 300 mm 127 Supply and delivery of UPVC pipe (CD) conforming to IS 12818:2010. (CIPET Certified)150 mm dia 128 Supply and delivery of UPVC pipe (CD) conforming to IS 12818:2010. (CIPET Certified) 250 mm dia. 129 Lowering the tube well assembly (UPVC Casing pipe ,well pipe, strainer along with UPVC accessories) vertically in a position with proper lowering arrangement by applying necessary jointing compound including labour cost for subsequent gravel packing and machine operation cost etc. 130 Washing and developing tube well with air compressor pump and engine for 8 (eight) hours continuous pumping per day with necessary arrangements for testing the yeild in gallons per hour with V notch including hire and labour charges for all tools and plants and scaffolding as required complete in all respect. 131 Labour for making arrangement for showing vertically test including the cost for hire charges of tools and plants, scaffolding labour etc. all complete. 132 Collecting sample of water for physical bacteriological and chemical test from any depth at any time during execution of work including hire and labour charges for tools and plants and sterilising the equipments, paying all charges and fees, testing etc, complete in all respect as per direction and as per IS 10500 parameters. 133 Packing the annular space between the outside of the tube well pipes & strainers and the bore with pea size washed gravel of approved quality having sizefrom 2 mm to 5 mm or the size aproved by the Engineer - in- charge including cost of materials labour and equipment complete. 134 Packing the annular space between the outside of the housing pipe &the bore with puddled clay balls of approved size as per direction of the Engineer - in- charge with cost of materials & labour complete. 135 Providing & fixing bottom plug as required for 150 mm dia PVC pipe including cost of materials & labour with fixing in position complete for sealing the bottom of assembly. 136 Supplying, fitting and fixingof M.S. Housing clamp 250 mm dia. 137 Supplying, fitting and fixing of M.S .Centre guide (Special Type) 138 Geophysical investigation of the aquifer by electro logging system with all tools & plants as necessary including supply of necessary report. 139 Supply and delivery of CIDF sluice valve (Special type) PW-1.00 of different dia make with CI double flanged non rusting spindle sluice valves conforming to IS 14846 -2000 with latest emended having body dome/bonnet and cover of C.I.Gr-F.G 210mtr. spindle of IS-6603 G.R- 12/Gr-13 non-magnetic, nuts seat rings are of Gunonetal as per IS:318 LTB-2 flanges and drilled to IS:1538 Part IV & VI valves are suitable for max. working pressure of 10kg/cm2(seat test) and body tested to 15kg/cm2. 100 mm dia. 140 Sluice valve chamber with C.I. heavy cover with locking arrangement, (weight not less than 25 kg) (size of chamber 450 mm X 600 mm inside upto 900 mm depth) 250 mm thick cement brick walls (6:1), 150 mm thick cement concrete (6:3:1) bed with stone chips, 20 mm thick cement plaster (6:1) for inside wall and 15 mm thick cement plaster (4:1) for outer walls including rounding corners 141 Construction of different dia Sluice valve / Air Valve /Washout chamber in the different sizes for village road where light traffic run and for main road where heavy traffic run as per as dept. approved drawing with 25cm brick work (1:6) over cement concrete (4:2:1) over a single B/F soling over 150mm thick sand filing in foundation including earth work in excavation and disposal of excess earth from work site with RCC cover slab (1:1.5:3) 100mm / 150mm thick slab on top of chamber with 1% reinforcement in RCC cover slab with necessary opening for operation of valve all complete including cost of labour and meterial as per departmental drawing ( Reinforcement type :Other manufacturers not specified) 142 Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately). 50 mm dia. medium quality. 143 Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately). 40 mm dia. medium quality. 144 Supplying, fitting and fixing in position G.I. pipes of TATA make for underground works with all necessary accessories,specials viz.socket, bend, tee, union, cross, elbow, nipple, short piece etc.including cost of all materials,jointing materials ,cutting pipes,making threads,cutting trenches upto 1.5 metre below surface in all sorts of soil and refilling the same as directed with two coats of painting on G.I. pipes and specials with bituminous paint complete in all respect. (Payment will be made on the centre line measurement of the total pipe line including all specials No separate payment will be made for accessories, specials.Payment for painting will be made seperately). 25 mm dia. medium quality. 145 Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for non-pressure underground Drainage, Sewerage & Cross drainage application.300 mm internal dia. 146 Supplying & laying Double Wall Corrugated (with external annular corrugation and smooth internal walls) High Density Polyethelene Pipes conforming to IS 16098 (Part-II):2013 having Stiffness Class of SN 8 with Ring Stiffness not less than 8.00 KN/Sqm. and Impact Resistance TIR value not more than 10% including necessary jointing materials for non-pressure underground Drainage, Sewerage & Cross drainage application.250 mm internal dia. 147 Constructing Inspection pit of inside measurement 600mm X 600mm X upto 600mm (depth) with 250 mm thick 1st. class brick work in cement mortar (1:4) on all sides, bottom of the pit consisting of 100 mm thick cement concrete (1:3:6) with stone chips over a layer of jhama brick flat soling, 15 mm thick (1:4) cement plaster to inside walls and out-side walls upto G.L. and 20 mm.thick (1:4) plaster to bottom of the pit, providing necessary invert with cement concrete (1:3:6) with stone chips as per direction, neat cement finishing to entire internal surfaces, top of the pit covered with 100 mm thick R.C.C. slab (1:1.5:3) with stone chips and necessary reinforcements upto 1% and shuttering including 6 mm thick cement plaster (1:4) in all external surfaces of the slab and one 560 mm dia. R.C.C. manhole cover of approved make supplied, fitted and fixed in the slab with necessary fittings, necessary earthwork in excavation in all sorts of soil, filling sides of the pit with earth and removing spoils after work complete in all respect with all costs of labour and materials. With Pakur variety. (SAIL/TATA/RINL) 148 UP-GRADATION WORK (ELECTRICAL) TIMBER POND 149 Scope of Work for DISCOM Connection & Related Statutory Approvals:The scope of work shall include obtaining all necessary permissions, clearances, and statutory approvals from CESC (DISCOM) for availing 11kV power supply connection for the proposed substation. This shall cover but not be limited to:1. Submission of all requisite documents, drawings, and applications to CESC as per prevailing guidelines and as per recent IE/CEA guideline and rule .2. Liaison and coordination with DISCOM(CESC) officials for site inspection, sanction load approval, and meter installation.3. Procurement and installation of all instruments/equipment as per DISCOM and statutory requirements (such as CT/PT, Energy Meter, AB Switch, GOAB, LA, Cable, etc.).4. Arrangement of statutory approvals from Regional Electrical Inspector (REI) and/or Central Electricity Authority (CEA) wherever applicable.5. Obtaining final charging permission and energisation clearance from DISCOM and statutory bodies.6. Any incidental expenses, statutory fees, and liaison charges associated with the above shall be in the vendor’s scope.The vendor shall be solely responsible for completing the entire process in compliance with applicable rules, regulations, and safety norms. 150 Job of Complete design & engineering, preparation of drawings, Single Line Diagrams (SLD), electrical calculations, and all related technical documentation required for the construction of a substation along with its outgoing distribution system with Installation, Testing and Commissioning. The vendor shall be responsible for: 1) The scope of Work includes Installation site survey in details.2) Preparation and submission of design calculations, technical specifications, and datasheets.3) Preparation of all relevant drawings including layout drawings, SLDs, GA drawings, and schematic diagrams.4) Submission and approval of all documents to the client(GRSE) & consultant(ICA) before execution.5) Incorporating any revsions or modifications as required during the review and approval process.6) Providing final as-built drawings and documentation upon completion. 7)Preparation of Final detailed project report (DPR) along with all certificate. 151 Involving Independent Certification Agency(ICA) for Approval of Design, Documents, BOQ, Witness the FAT (Factory Acceptance Report) before dispatch of materials at OEM premises & SAT (Site Acceptance Test) at site during Erection, Testing & Commissioning of the Project. 152 Point wiring in GI Conduit with Modular type Switch:- Wiring for light point / exhaust fan point / call bell point with 1.5 Sq mm FRLS PVC insulated copper conductor, single care cable in surface / recessed GI conduit, with modular switch, Modular Plate, Suitable GI box and earthing the point with 1.5 Sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Make of modular switches as per make list. (Make Modular Switch Sockets:- MK (Blenz), Legrand (Arteor)/ Schneider(Zencello)/ Havells- Cabttery-Premium) 153 Supplying and fixing offollowing Modular switch/ socket for modular plate & switch box including connections but excluding modular plate etc. as reqd. (Make Modular Switch Sockets:- MK (Blenz), Legrand (Arteor)/ Schneider(Zencello)/ Havells- Cabttery- Premium) 5/6 amps switch(60 nos) 15/16 amps switch (20 nos) 154 Supplying and fixing offollowing Modular switch/ socket for modular plate & switch box including connections but excluding modular plate etc. as reqd. (Make Modular Switch Sockets:- MK (Blenz), Legrand (Arteor)/ Schneider(Zencello)/ Havells- Cabttery- Premium) 3 pin 5/6A(30 nos) & 15/16A(10 nos) socket outlet 155 Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required.6 Module (200mmX75mm) 156 Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required8 Module (125mmX125mm) 157 Supply and fixing of following size/ modules, GI box along with modular base & cover plate for modular switch/ regulator in recess, including connection as required 12 Module (200mmX150mm) 158 Supplying & fixing of 3 pin, 5 amp Ceiling rose on including connection as required 159 Supplying and fixing brass batten/angle holder including connection with Supply, fitting, fixing & testing of 10W/12W LED Bulb in existing holders. (Make:- Philips/ Trilux/Wipro/Havells). etc. as required. 160 Supplying and fixing following way, horizontal type three pole & neutral, sheet steel, MCB distribution board, 415V, on surface/ recces , complete with tinned copper bus bar, neutral bar, earth bar, din bar interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/Isolator) Make- Legrnd/Siemens/ L&T.6 way (4+18) Double door 161 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way , Double door 162 Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, C curveMiniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make- Legrnd/Schneider/Siemens/ L&T- U Version.Single Pole(6A-70nos,10A-50nos,16A-30nos) 163 Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, C curveMiniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make- Legrnd/Schneider/Siemens/ L&T- U Version Double Pole (10A-15Nos,16A-10 nos 164 Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, C curveMiniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make- Legrnd/Schneider/Siemens/ L&T- U Version Triple Pole(25A-5 nos & 32 A-10 Nos) 165 Supplying & fixing 5 amps to 32 amps rating 240/415 volts 10 kA, C curveMiniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make- Legrnd/Schneider/Siemens/ L&T- U Version Four Pole(32A-10nos) 166 Supplying & fixing & connection of40A rating double pole (Single Phase & Neutral) 240 V, Resudual Curren Circuit Breaker (RCCB) , having a sensitivity suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and ccurrent 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.Make- Legrnd/Siemens/ L&T- U Version. 167 Supplying and fixing & connectionof 20 Amps, 415 Volts, TPN Industrial type, socket out lets, with 4 pole and earth, metal enclosed plug top alongwith 20 Amps.C curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket 0ut let and complete with connections, testing and commissioning etc. as required.Make- L & T, Legrand, Schneider/Siemens 168 Supplying and fixing & connectionof 30 Amps, 415 Volts, TPN Industrial type, socket out lets, with 4 pole and earth, metal enclosed plug top alongwith 30 Amps.C curve, TP MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the shocket 0ut let and complete with connections, testing and commissioning etc. as required.Make- L & T, Legrand, Schneider, Siemens 169 Supply, Erection, testing & commissioning of SDF 63A TPN 4P, 415V AC Open Execution & SS Enclosure, CE Handle DIN Type SFU with necessary connection. 170 Supply & fixing of M.V. danger notice plate of 200 mm x 150 mm, made of mild steel, at least 2 mm thick, and vitreous enamelled white on both sides, and with inscription in single red colour on front side as required. 171 supply,fixing Earthing with G.I. Earth Pipe 4.5 meter long, 40 mm dia including accessories and providing masonary enclosure with cover plate having locking arragement and watering pipe etc. with charcoal/cock and salt as required. (FOR LIGHTNING ARRESTER) 172 supply,fixing Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. 173 supply,fixing Earthing with Copper Earth Plate 600 mmx600 mmx3 mm thick including accessories and providing masonary enclosure with cover plate having locking arragement and watering pipe of 2.7 meter long etc. with charcoal/cock and salt as required.2 nos. Neutral Pits for Each Transformer 174 Supplying and laying 50 mm X 5 mm copper strip at 0.50 meter below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) 175 Supplying and laying 50 mm X 6 mm GI strip at 0.50 meter below ground/surface as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) 176 Supplying & fixing 20mm dia 2 mtr long G.I spike type Earth Rod 177 Supplying and laying 25 mm X 3 mm GI strip at 0.50 meter below ground/surface as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required(Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) 178 Supply, testing,Laying and commissioning of following type of1100V grade XLPE insulated, armoured aluminium cable as per specification and SLD 3.5 Core 400 Sq. mm 179 Supply, testing,Laying and commissioning of following type of1100V grade XLPE insulated, armoured aluminium cable as per specification and SLD 3.5 Core 150 Sq. mm 180 Supply, testing,Laying and commissioning of following type of1100V grade XLPE insulated, armoured aluminium cable as per specification and SLD 3.5 Core 50 Sq. mm. 181 Supply, testing,Laying and commissioning of following type of1100V grade XLPE insulated, armoured aluminium cable as per specification and SLD 3.5 Core 25 Sq. mm. 182 HT Cable: Supplying of Unearthed/earthed armoured, aluminium conductor XLPE power cable of 11 KV grade confirming to IS 7098 (Part II) amended upto date as per the following size: 3x300 sqmm.(Actual requirement of length to be taken as per site requirement) 183 1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. 3.5 Core 400 Sq. mm(82mm) 184 1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. 3.5 Core 150 Sq. mm.(50mm) 185 1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. 3.5 Core 50 Sq. mm.(35mm) 186 1.1 KV Cable End Termination:-Supplying and making indoor cable end termination with brass double compression gland and aluminium lugs for following size of PVC insulated XLPE Al. Ar. Cable of 1.1 KV grade as required. 3.5 Core 25 Sq. mm.(28mm) 187 supplying and making indoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required For 300 Sq.mm11kv HT cable 188 Supply Installation, testing and commissioning of 40 Watt 4 ft LED fitting complete with all accessories including supplying and fixing ball and socket arrangement, 2 Nos. down rods of 20 mm dia X 1.6 mm thick steel conduit upto 30 cm length, painting and wiring the down rods and connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. 189 Supply, fitting, fixing and testing of LED BOX Type 2X20W (1x40W) NEXT (1200mm) (suspended Type) with Advance optical PC material for excellent and smooth light output, CRI>80, uniform distribution,lumen output should be minimum 4000,Lifetime of 30,000 burning hours@L70, comply to 3KV surge test(avoiding damage caused by input voltage fluctuation and lightning strike) and high-pot test(4KV) compliance of CE,KEMA, RoHS, REACH, Color Temperature should be6500k ,Power Factor >.9,THD<10 ,Working Temp -20 to 45D Celsius, LM 79 and LM 80 reports need to be submitted with all accessories. Make Philips /Trilux/WIPRO 190 Building Outer Light (45/48W LED) :- Supply, fitting, fixing and testingof building outer lighting luminaire aerodynamically shaped single piece pressure die-cast Aluminum luminaire with high power LEDs as light source and electronic driver (IP65), along with 45/48W LED Lamp,(4000K)as Energy savingas per drawing prescribedreflector and heat resistant toughened flat glass cover, with 5ft long 40mm dia G.I. pipe with 3 Nos. of iron clamps , anchor nut bolts with double washers as per direction of E/I or consultant as per drawing prescribedreflector and heat resistant toughened flat glass cover (IP-65) (Make:- Philips/ Trilux/Wipro). 191 POLE LIGHT:Supply, erection, Testing & commissioning of outdoor type 200W LED Flood Light, 220V-240V, IP56 with 7mtrs Hight Octagonal Light Pole and Connection of 2nos LED Flood Light each pole 192 HIGH MAST LIGHT:Supply, erection, Testing & commissioning of outdoor type 350W LED Flood Light, 220V-240V, IP-56 with 25mtrs Height High Mast Light Pole and Connection of 8nos LED Flood Light each High Mast & Provide sufficient LA at the top of High mast 193 Supply Installation Connection of LED Flood Light 100 Watt 194 Supply of 1400mm sweep ceiling fans complete with, motor, blades, down rod, suitable for operation on 230 volts, 50 Hz., 1 phase, AC supply connection with 1.5 sq.mm PVC Copper wirecomplete as required ISI minimum air delivery of 280 CFM/M, 2 years warranty. Fan shall be provided or approved by engineer incharge) Make- Havells/ Atomberg / CROMPTON./reputed Company 195 Supply of 300mm 230V AC Exhaust Fan 300mm(Meta Body- Heavy Duty) exhaustfandouble ball bearingas required. Make- Havells /Usha/Crompton.GEC 196 MAIN LT PANEL (PCC PANEL) OF SUB- STATION BUILDING: Supplying, designing, manufacturing, installation, un loading at site, shifting in location, testing and commissioning in correct alignment position, effecting proper connection of all incomer and outgoing ofMain LT Panel (PCC PANEL), floor mounting with Base Channel size - 100 mm x 100 mm x 6 mm (for as per Tested Assembly (TA) PANEL NORMS with aproper lifting arrangement or as perIEC 61439-1 & 2 standard and IEC 61641 for Internal Arc.Note:- The Contractor may select the next higher fault rating of ACCB/MCCB if it is not readily available, without any extra cost, as the figure indicated within the bracket are required maximum fault level of the above panels. 197 A.P.F.C. Panel (Capacitor Bank) :-Supplying, designing, manufacturing, installation, un loading at site, shifting in location, testing and commissioning in correct alignment position, effecting proper connection of all incomer and outgoing of APFC Panel of capacity 550 KVAR @ 415V. The stage ratings shall beas mentioned in SLD.The APFC Panel shall be fully type tested at an Independent Laboratory and shall comply to IEC 61439-1&2 and IEC 61921. The APFC Panel shall beIP31 type,weather, dust and vermin proof suitable for humidity up to 95%. Average daily temperature: +35°C max, Ambient temperature: -5°C to 45°C, Maximum altitude: 2000 m. The equipment shall be manufactured as directed by the Engr-in-Charge and shall comprising of the following: Shop drawings shall be approved by Consultant. The APFC floor mounting with Base Channel size - 100 mm x 100 mm x 6 mm with aproper lifting arrangement or as perIEC 61439-1 & 2 standard.Note:- The Contractor may select the next higher fault rating of ACCB/MCCB if it is not readily available, without any extra cost, as the figure indicated within the bracket are required maximum fault level of the above panels. 198 11 KV VCB (HT SWITCHBOARD) ( THREE PANEL) ONE INCOMER & TWO OUT GOING- INDOOR DUTY : Supply, designe, manufacturing, installation, unloading at site, shifting to location, inspection, installstion, testing & commissoning of three Panel (one incomer + two outgoing) indoor duty of HT Panel (VCB) totally enclosed sheet steel clad floor mounting, vermin proof, fully interlocked vertical isolation, extensible, horizontal draw out, air insulated, metal clad switchboard having double isolation features complete with circuits as detailed below. The switchboard would be complete with necessary PVC insulated copper bus bars, small wiring, labels, cable eyes, cable termination to receive XLPE cables, foundation bolts and suitable for operation on 11 kV 3 phase, 50 cycle, earthed system with a rupturing capacity of comprising of 400A/26.3kA/3 Sec. as per IEC-62271-200 (CT ratio IS: 2705 ) at 11 kV Panel as per SLD and specification as required. Make:- Kirloskar Electric/Crampton/L & T/Siemens/Schneider.For that all arrangements shall be done by the contractor scope. 199 1500 KVA INDOOR (OIL COOLED, COPPER WOUND) TRANSFORMER 11/0.433KV (OCTC) : Supply, designe, manufacturing, installation, unloading at site, shifting to location, inspection, installstion, testing & commissoning of) of continuous rating of 1500 KVA 11/0.433KV,OCTC oil Cooled, copper wound indoor Transformer as per IS:2026 including HV termination box with air filled cable box suitable for 11KV 1 Run 3 Core 300 Sq mm XLPE AL./AR./C and LV termination box with air filled cable box suitable for 1.1KV 6 Run 3.5CoreSq mm Al./AR.XLPE PVC insulated cable etc as required. Make:- Voltamp Transforemrs Ltd./ Kirloskar Electric Co. Ltd /POWER STAR/Crompton Greaves/Siemens Ltd.Before Deliver Factory Inspection of 11 KV/0.433KV Oil Cooled 1500 KVA Indoor Transformer (IS-2026)shall be carried out in presence of Engineering inchargeof GRSE and ICA. (Elec.) for that all arrangements shall be made by the contractor. 200 Battery Charger Unit with Battery & Battery Rack: - Supply, design, manufacturing, instgallation, unloding at site, shifting in location, commissioning and testingof 1 No Automatic float cum boost (50 Amp) battery charging equipment suitable for 110V, 200AH, VRLA with value regulated SMF lead acid 110V (55 cells) 200AHbattery type 55 UPST200 ofwith stand and standard accessories, conforming to degree of protection IP – 42, sheet steel enclosure 14 SWG thick, with automatic voltage regulation, current limiting circuitry, auto cut facility, smooth filter circuit switches, ammeter & voltmeter on DC side, RYB indicating lamps (LED type) on AC side complete in all respect with float and boost / buck charging, switchgear, Earthing, powder coated etc as required including one no. distribution board having 63 Amps DP MCCB as incomer and 12 Nos. 20/16A DP MCBs (D.C. duty) as outgoing complete as required and as per technical specifications. Make:-Baid Power Services Pvt Ltd, , Amar Raja Power System Ltd, HBL, & LIVE LINE,MAKE Battery- Exide/Quantum/HBL.Note:- All technical Data Sheet and GA Drawing of battery charger shall be approved by consulatant before final delivery. Inspection of the same shall be carried out at companys factory before delivery. 201 Supply,complete Installation,Testing & Commissioning of 1.5 KVA UPS system for emergency lighting,signage etc 202 Sub-Station Auxiliaries:-(CONTROL CABLES):- Supply, laying, testing of 650V/1100V grade copper conductor 2xyHFFR XLPE insulated sheathed Unarmoured multicore control cable for various control requirement, including GI spacer, saddle for support end termination with cable gland, cable lugs, 20/25 mm dia PVC conduit of 2 mm thicketc, complete as specified in Sub-Station Area. (Confirming to IS 7098 (Part-1) 1988(Make:- LAP / Fenolex / Havells) 2 C x 1.5 Sq mm 2XYHFFR 203 Sub-Station Auxiliaries:-(CONTROL CABLES):- Supply, laying, testing of 650V/1100V grade copper conductor 2xyHFFR XLPE insulated sheathed Unarmoured multicore control cable for various control requirement, including GI spacer, saddle for support end termination with cable gland, cable lugs, 20/25 mm dia PVC conduit of 2 mm thicketc, complete as specified in Sub-Station Area. (Confirming to IS 7098 (Part-1) 1988(Make:- LAP / Fenolex / Havells) 3 C x 1.5 Sq mm 2XY HFFR 204 Sub-Station Auxiliaries:-(CONTROL CABLES):- Supply, laying, testing of 650V/1100V grade copper conductor 2xyHFFR XLPE insulated sheathed Unarmoured multicore control cable for various control requirement, including GI spacer, saddle for support end termination with cable gland, cable lugs, 20/25 mm dia PVC conduit of 2 mm thicketc, complete as specified in Sub-Station Area. (Confirming to IS 7098 (Part-1) 1988(Make:- LAP / Fenolex / Havells) 4 C x 1.5 Sq mm 2XY HFFR 205 CABLE TRAY: Supply, erection Testing & commissioning of 300 mm or pre fabricated hot deep galvanised Iron Ladder type cable tray for LT cable with proper supporting arrangement 206 CABLE TRAY: Supply, erection Testing & commissioning of 450 mm or pre fabricated hot deep galvanised Iron Ladder type cable tray for LT cable with proper supporting arrangement 207 CABLE TRAY: Supply, erection Testing & commissioning of 100 mm or pre fabricated hot deep galvanised Iron Ladder type cable tray for LT cable with proper supporting arrangement 208 LA: Supply,Installation Testing & commissioning of Heavy Duty Lightning Arrester(LA) suitable for 11kV/33kV/66kV(as required),outdoor type,station class metal oxide confirming to IEC 60099-4/IS 3070 with Earthing arregment and Surge counter. 209 Providing a mat made of elastomeric polymers Material (Class-B) one mtr. wide and 2.5 mm thick to withstand 15 KV dielectric strength AS PER IS 15652 : 200. 1000 mm x 600 mm x 12 mm thick chequered Rubber Mattingof tested quality to with stand 15KV dielectric strenght as per IS:5424 210 Supply of 440V grade Rubber Hands Gloves. As per IS:4770. 211 Supply of of Maintence tool kit with 1 pair 11 KV rubber hand gloves of approved make, as per IS:4770. 212 Supply of First Aid Box with all necessary materials and medicine as approved by Indian Red Cross / St. Johns conforming to IS:2217. 213 Supply and fixing of Shock Treatment Chart with glass in Aluminium frame and to be fixed on wall in Bengali and English. 214 Supply and fixing position the approved single line diagram framed in 1000 x 800 mm size glass frame and installed in main switch room. 215 Fire Extinguisher:-Supplying, commissioning and fixing of Carbon dioxide (Co2) type fire extinguisher of 4.5 Kg. Capacity duly charged confirming to IS: 2828. Make:- Minimax,Real value/Firex/Deflame. 216 Supplying and Fixing 3 Nos. 9 Ltr capacity G.I. buckets duly painted white inside and red oxide paint out side and written FIREwith white paint and filled with dry sand and mounted on MS angle iron bracket of size 50x50x6mm thick and 1200mm long including grouting in wall/floor etc. as required confirming to IS:2546-1974. 217 Supply, laying, testing of 650V/1100V grade armoured copper cable 2xyHFFR XLPE insulated sheathed Unarmoured multicore control cable for various control requirement, including GI spacer, saddle for support end termination with cable gland, cable lugs, 20/25 mm dia PVC conduit of 2 mm thicketc, complete as specified in Sub-Station Area. (Confirming to IS 7098 (Part-1) 1988(Make:- LAP / Fenolex / Havells) 4 C x 2.5 Sq mm 2XY HFFR 218 Supply, laying, testing of 650V/1100V grade armoured copper cable 2xyHFFR XLPE insulated sheathed Unarmoured multicore control cable for various control requirement, including GI spacer, saddle for support end termination with cable gland, cable lugs, 20/25 mm dia PVC conduit of 2 mm thicketc, complete as specified in Sub-Station Area. (Confirming to IS 7098 (Part-1) 1988(Make:- LAP / Fenolex / Havells) 4 C x 6 Sq mm 2XY HFFR 219 Supply, laying, testing of 650V/1100V grade armoured copper cable2xyHFFR XLPE insulated sheathed Unarmoured multicore control cable for various control requirement, including GI spacer, saddle for support end termination with cable gland, cable lugs, 20/25 mm dia PVC conduit of 2 mm thicketc, complete as specified in Sub-Station Area. (Confirming to IS 7098 (Part-1) 1988(Make:- LAP / Fenolex / Havells) 4 C x10 Sq mm 2XY HFFR 220 Supply, installation, testing and commissioning of 2 HP submersible borewell pump set complete with DOL starter, suitable control panel with MCB, necessary power and control cabling (including 2.5 sqmm 3.5C armoured cable from pump to starter, 4.0 sqmm 2C cable from starter to power source), earthing arrangement with GI pipe/plate and GI strip, mounting frame, cable glands, lugs, and other necessary accessories as required for complete operation 221 Supply, installation, testing, and commissioning of 100 HP dewatering pump set including suitable starter panel with motor protection, power and control cabling with termination, suction and delivery pipeline with valves , MS base frame with anti-vibration mounts, earthing arrangement, and all necessary accessories for complete functional operation 222 Supply, installation, testing and commissioning of 1 HP centrifugal water supply pump set complete with suitable DOL starter/control panel, power and control cabling with terminations, earthing arrangement, suction and delivery pipelines with valves and NRV, foundation arrangements, and all necessary accessories for complete functional operation for Municipality storage tank 223 Main lighting DB:Design, fabrication, supply, installation, testing & commissioning of Main Lighting Distribution Board (MLDB) suitable for 415V, 3 Phase, 4 Wire, 50 Hz AC supply system, floor-mounted, totally enclosed, dust & vermin proof, made of CRCA sheet steel of min 2.0 mm thickness, powder coated with Siemens grey shade both inside & outside, IP-54 protection.with I/C-400A MCCB,O/G-MCCB-3 nos 32A,3 nos 25A,2 nos 16A and Place for Various rating MCB(4P,3P,2P,1P as Required) Make of MCCB/MCB - L & T, Legrand, Schneider/Siemens