| 1 | M/L for Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard and dense soil. |
| 2 | M/L for Returning, filling in, including spreading, levelling, watering and well ramming in layersnot exc 25 cm in hard and dense soil |
| 3 | M/L for Reinforced Cement Concrete Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete.M-20(20mm graded aggregates) |
| 4 | M/L for Reinforced Cement Concrete Walls, retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses. M20(20mm graded aggregates) |
| 5 | M/L for Formwork to sides of concrete foundations, footings, bases ofcolumns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter withflat & fair finished surface.(316.72+80.39) |
| 6 | M & L for mild steel TMT bars of 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips; Complete all as specified and as directed by the Engineer-in-Charge. |
| 7 | S/F welded steel wire fabric supplied and fixed complete to wood or steel members (wt. per square metre Exc. 4 Kg.) |
| 8 | Supply and Fixing for Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lengths i.e. within 20mm of the length indicated ) Fe-410 W (Gde-E-250 quality B) |
| 9 | M/L for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width and setting in mortar,complete Set in cement mortar 1:4 Type B1 1:2:4 (20mm graded aggregates) |
| 10 | M/L for Rendering 15mm thick on fair faces of brick work or concrete surfaces with cement plaster 1:4 and finish the surface even and smooth without using extra cement including coat.(204.80+58.32+41.12) |
| 11 | Hiring of JCB\"s including Driver, fuel and other necessary items for cleaning and dumping of waste material in lorry from work execution siteas per direction of Engg. In Charge. |
| 12 | Hiring of tripper lorry including Driver, fuel and other necessary items for shifting of waste material from work execution site to 500m away at inside Factory as per direction of Engg. In Charge. |
| 13 | Supplying and laying of CPVC pipes 25mm outer diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 14 | Supplying and laying of CPVC pipes 50mmouter diameter SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified. |
| 15 | M&L 6 Way module modular metal flush box |
| 16 | M&L 6 module white modular cover plate with frame |
| 17 | M & L of Modular switch 1 way 6A, 1 module |
| 18 | M & L of Modular switch 1 way 16A, 1 module |
| 19 | S & F of Socket, 6A - 2/3 pin combined 2 module, |
| 20 | S & F Socket 6A/16A - 2/3 pin combined 2 module, |
| 21 | M & L for One lightpoint or one fan point controlled one switch with cables 2.5 sq. mm size wiring with copper conductor cables FRLS in PVC Conduict PVC single core sheathed cable |
| 22 | M&L For Sub main wiring along with single core earthwire with2x 6.0 SQ MM in PVC Insulated Copper conductor with 1x6.0 mm earth wire with Suitable PVC conduit pipe &accessories. As directed by the Engineer-in-charge. |
| 23 | M&L For Sub main wiring along with single core earthwire with2x 4SQ MMin PVC insulated Copper conductor with 1x4 sq. mm earth wire with Suitable PVC conduit pipe &accessories. As directed by the Engineer-in-charge. |
| 24 | Supply and Fixing of De-watering (Sewage) Pump, ETERNA 1500 CW+, 2 HP, Three Phase, 415 Volts, Size 50mm SPEED (RPM) 2840, DISCHARGE : 6 LPS, PUMP SHAFT S.S. TERNA 1500 CW+ or equivalent or as approved by Engineer-in-charge(Make: KIRLOSKAR ,CROMPTON, V-GUARD, ETC as approved by Engineer-in-charge |
| 25 | Supply and FIxing of Openwell Submersible Pump, 2 HP, Single Phase, 210 Volts, Size 32mm X 25mm with Control Panel SPEED (RPM) 2800, DISCHARGE :3.35 LPS, or equivalent or as approved by Engineer-in-charge(Make: KIRLOSKAR ,CROMPTON, V-GUARD, ETC as approved by Engineer-in-charge |
| 26 | Cleaning of septic tank (sump) by dewatering and sludge removing with vehicle, labour and equipment of size 40ft * 20ft* 4ft -3 No.s and taking out away minimum 10km from the factory premises. |
| 27 | M/L forChain link MS galvanisd fencing of size 0.075m*0.075m*4mm dia. GI wire fencing with galvanised weight of 240 GSM. Complete all as specified and directed by the E-I-C.(3.5kg/sq.m) |
| 28 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire.(3.5kg/sq.m) |
| 29 | Applying Two coats of Synthetic enamel paints (Berger/Asian/ICI) over preparation of new surfaces on steel surfaces of any description, over aluminium red oxide primer, above 10 cm in width or girth. |
| 30 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, in hard densesoil |
| 31 | M & L for P.C.C.in foundations filling and mass concrete 1:4:8 Type D2 , with 40mm graded aggregate,. |
| 32 | M & L for mild steel Round bars of 10 mm dia and over, cut to length, bent to shape required, Fe-410-W (Gde.E-250)quality-A or Fe 290 (Gde-E-165)including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia. or securing with clips; Complete all as specified and as directed by the Engineer-in-Charge. |