Tender For Work Of Providing Drinking Water To Bhawani Mandi And Sunel Town Including 14 Villages Of Piplad Water Supply Scheme From Rajgarh Dam, District Jhalawar Including 10 Years Oanm After 1 Year Defect Liability Period Under Budget Announcement 2024- - BHAWANNIMANDI & SUNEL TOWN AND 14 VILLAGESOF PIPLAD WATER SUPPLY SCHEME FROM RAJGARH DAM, JHALAWAR Sl. No. Item Description 1 Providing, lowering, laying in trenches, aligning, fixing in position and jointingDuctileIron(DI)ISI markedK-7gradeS&Spipesas per IS:8329-2000 (amendedup todate),withinternalcementmortar lining suitable for potablewater with rubber ring (EPDM)joints as per IS: 5382-1985 including all taxes (Central and local), transportation and freight charges, inspection charges, loading/ unloading charges,including cost of labour and material, specials (Tee, bend etc.) satisfactory hydraulic testing, disinfection, commissioning etc. complete as per technical specifications and direction of Engineer-in-charge. (excluding earth work)Note : Providing and fixing of all requisite specials as per drawing, design and layout are inclusive in RM measurement of the item and shall not be paid separately. 2 450 mm 3 500 mm 4 600 mm 5 Providing and fixing of flanged/ plain ended MS Specials made from MS sheet strips of relevant IS specification of approved thickness by welding,lowering,laying,aligning,fixinginpositionatalllevel/ depths in trenches complete includingall taxes, material,labour, inside lining, outside coating, testingandcommissioning alongwithpipelineaspertechnicalspecifications anddirection of Engineer-in-charge. 6 MS pipespecialsup to600mmdia (withminimum5mmthickness sheet) 7 Supplying & Installing 100 mm diameter sealed diaphragm bourdon type pressure gauge of range 0 to 10 kg.including all jointing material as per specification with safety cover. 8 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and disposal of surplus excavated soil as directed within a lead of 50 Mtr. including required all safety provisions etc.: All kinds of soil 9 Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in trenches of required width and gradient for laying and jointing of pipe line including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5 Mtr. including taking out the excavated soil, and then returning the soil as required in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering etc. and stacking serviceable material for measurements and disposal of unserviceable material as directed, with in a lead of 50 Mtr. including all safety provisions required .: 10 Ordinary rock 11 Dismantling of cement concrete pavement for pipe lineand chambers by mechanical means using pneumatic tools, cutting the peripheral edge by CC cutter, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks as per technical specification and scope of work. 12 Dismantling of flexible pavement for pipe lineand chambers by mechanical means using pneumatic tools, breaking to pieces not exceeding 0.02 cum in volume and stock piling at designated locations and disposal of dismantled materials up to a lead of 1000 meters. Measurement for dismantled trench to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified, re-handling of material/earth to complete the tasks per technical specification and scope of work. 13 Bituminous courses 14 Granular courses 15 Providing and laying in position cement concrete M10 grade nominal mix 1:3:6 (1 Cement : 3coarse sand : 6 graded stone aggregate 40 mm nominal size) in base course complete including all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 16 Providing and laying in position cement concrete in specified grade over prepared base course complete including finishing, curing, all material, labour, machinery, lighting, guarding for road restoration work in trenches of pipe line and chamber work. Measurement for CC work to be madeas per standard trench width specified in tender document and no extra payment shall be made be made for trench width more than specified,complete work as per technical specification and scope of work. 17 Plain cement concrete pavementof M-30 Grade 18 Providing, lowering, aligning, fixing in position and Jointing in pipe line, CI Double Acting Kinetic Air Valve with isolating Sluice Valveof approved makes for following pressure rating & dia complete, confirming to IS: 14845-2000 (amendedup to date) and of following specifications: Body , Cover and Cowl - Grey Cast Iron as per IS:210- FG 200 ,Float - Stainless Steel AISI 304 / IS: 3444 ,Float Guide- HBT1.HP Orifice-HTB2/ SS,Body seat ring - Leaded tin bronze/ SS .Seal ring and face ring - EPDM/NBR ,Ends flanged according to IS 6418,Fastners - CS, Epoxy paint inside outside of food grade safe for drinking water ,Valves including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer in charge.Note: Rates are exclusive of connecting tee, pipe piece and earth work. 19 Class PN 1.0 20 150 mm 21 Providing, lowering, aligning, fixing in position in pipe line at work site, DI D/F Resilient seated (soft seated) Sluice Valves (Gate Valves) , Vacuum tight(bubble tight), straight and pocket less body passage of approved make of following class & dia complete confirming to BS-EN-1171/ AWWA C-509 and of following specifications: Body & bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Wedge of same material as body & shall vulcanisedrubber lined with EPDM (food grade quality) and seals of NBR Face to face dimensions as per BS 5163-89/ IS 14846/2000 (amended up to date) /Din 3202 F4, Stem/ spindle of SS AISI 316/410 Electrostatic epoxy powder(EP-P)/ Fusion bond epoxy ( Non-Toxic- suitable for drinking water) coated with minimum thickness of 250 microns inside and outside, Drilled as per IS 1538. Nut-Bolt confirming to IS:1363 and IS: 1367(Galvanised steel) Insertion rubber of black EPDM 6mm thick. Suitablesupport structure as per directions of EIC, Sluice valves including all jointing & jointing material, labour, testing and commissioning along with pipe line as per Technical Specifications and as per direction of Engineer-in-charge. Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 22 Manually Operated Resilient Seated Sluice Valves of Class PN 1.6 23 450 mm dia 24 400 mm dia 25 500 mm dia 26 600 mm dia. 27 Motorized Sluice Valves with Electric Actuator and integral starter of Class PN 1.0 28 400 mm dia 29 Providing, lowering, aligning, fixing in position in pipe line, DIdouble flanged resilient seated Dual plate check valve of approved make of following Pressure rating & dia complete,as per API: 594/ API: 598 and of following specifications: Body & Bonnet of Ductile cast iron of grade GGG40/GGG50 as per DIN 1693 or GR SG-400/12 as per IS 1865 or equivalent grade as per IS :3896-part2-1985 and subsequent revisions, Disc / plates - SG-400/12 or CF-8M,Face to face dimensions as per API: 594 , Flanges Drilled as per IS:1538. Electrostatic Epoxy Powder(EP-P) / Fusion Bonded Epoxy (Non-Toxic & suitable for drinking water) coated with minimum thickness of 250 micron applied on body and cover inside and outside .Disc seal ring of EPDM/ Neoprene (food grade quality) and disc seal retaining ring of SS/CS. Shaft of SS- AISI- 410 , Hinge SS AISI 316/304,SpringSS AISI 316/304,Bonnet Gasket EPDM ,Bush- Brass with EPDM/NBR O ring seal, Nut-Bolt confirming to IS:1363 and IS: 1367 (galvanised steel) ,Insertion rubber of black EPDM 6mm thick .Suitablesupport structure as per directions of EICincluding jointing & jointing material, labour, testing and commissioning along with pipeline as per Technical Specification & as per direction of Engineer-in-charge.Note: Rates are exclusive of tail piece/ dismantling joints and earth work. 30 Class PN 1.6 31 400 mm dia 32 Providing, lowering, laying, aligning, fixing in position and jointing CI dismantling joint (Suitable for Sluice valves etc.) as per IS specifications complete of the following sizes including all jointing material, cost of all labour, testing and commissioning Technical Specifications and as per direction of Engineer. Class PN 1.0 33 450 mm dia 34 500 mm dia. 35 600 mm dia. 36 Providing, installation, testing and commissioning of following Stain less steel AISI 304 Expansion bellows of 10/16 bar rating with tie rods as per technical specifications and layout drawings including jointing material like nuts, bolts, rubber gaskets etc. complete in all respect as per technical specification and as per direction of Engineer. 37 400 mm dia. 38 500 mm dia. 39 600 mm dia. 40 Construction of RCC pillar for following size of air valves including earthwork excavation,RCC M25 grade for base slab, vertical pillar, including cost of steel reinforcement ,GI (class-B)/MS vertical pipe, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as per direction of Engineer-in-Charge. 41 Air valve pillarfor airvalves size of 150mmdia 42 Construction of RCC Sluice valve chamber for different type of valves including earthwork excavation, 100mm PCC M15as levelling course, RCC M25 grade for base slab, side wall & cover slab , including cost of steel reinforcement , form work, Pre-cast slabs, plastic encapsulated CI/MS Foot Rest, MS flats for the support of pre-cast, proper curing of concrete work complete in all respect as perspecifications and standard drawings and as per direction of Engineer-in-Charge. 43 For Class-A loading 44 Sluice valve chamber of size 1.39m x1.43m x2.245mfor pipe size-from 350-to-450mm 45 Sluice valve chamber of size 1.61m x1.75m x2.85mfor pipe size-from 500-to-700mm 46 SITC of D/F Full bore type Electromagnetic Flow Meter of approved make of following dia and specifications complete: Media : Water (Raw/ Chlorinated) ,Pressure : up to 1.5MPa, Process temp: - 50 deg C, Flow/Meter Tube : SS 304,Electrode : SS AISI 316L /Hastelloy C276/ Tantalum, Lining Material : Hard Rubber/ Neoprene / Poly-urethane (PU) , Flange : SS / CS, Flange Standard & Rating : ANSI 150, Coil housing : SS AISI 304/ Carbon Steel/ Die Cast Aluminium, with anticorrosive paint & provide completely sealed (leak proof) construction as per requirement of IEC 60529, Accuracy : ± 0.5 % M.V.- velocity 0.3 to 10 m/s, Transmitter/ signal convertor Enclosure : Die Cast Aluminium, Power Supply : 80-240 V AC - 50Hz, Output 1 : 4-20 mA, Output 2: Pulse, Communication Output : RS 485/ Heart,Display Type : LCD/ LED Display, Cable Entry : M20 X 1.5, Provision of RAM/PROM to store calibration and configuration parametersand totalizer value during power failure, Protection category- IP 68 for sensor (flow tube) and IP 67 for transmitter/ convertor, including Surge Arrester, if required, and all materials required for making connection etc. complete in all respect as per technical specification and direction of Engineer In-Charge.Note: Rates are exclusive of tail piece / dismantling joints and earth work. 47 EFM 300 mm 48 EFM 600 mm 49 Providing, laying, spreading and compacting of granular sub-base by providing close graded material (Table 400-1), spreading in uniform layers with motor grader on prepared surface, mixing by mix in place method with rotavator at OMC, and compacting with vibratory roller to achieve the desired density, complete as perMoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 50 Grading - I Material 51 Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 52 Scarifying existing granular road surface, including picking up scarified material and stacking of old serviceable material within a lead of 1000 meters complete as per clause 305.4.3 of MoRT&H specification including all labour, machinery, lighting, guarding and maintenance of diversion. 53 Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 54 Providing and applying tack coat on the prepared surface with bitumen emulsion as per IS: 8887 and approved quality @ 0.2 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 55 Providing and laying 50-75 mm compacted thick design mix (approved by Engineer) Dense Bituminous Macadam on prepared surface with specified graded crushed aggregates as per Table 500- 9, 500-10 with bitumen binder set (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required) for base/ binder course including loading of material with F.E. loader, heating and mixing of stone aggregate, filler and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted withelectronic sensor control as per clause 504.3.5 to the required level and grade, compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa to achieve the desired density (approximately 2.3 tonne/cum) complete as per clause 507 of MoRT&Hspecification but excluding primer/tack coat, including all material, labour, machinery, lighting, guarding and maintenance of diversion. 56 Grade-II with Bitumen VG-grade 30 @ 4.25 %, lime filler @ 2% (percent by weight of total mix) 57 Providing and laying 30-45 mm compacted thickness Bituminous Concrete as per design mix (approved by Engineer) on prepared surface with specified grade stone aggregate as per Table - 500-18 with bitumen for wearing course including loading of aggregate with F.E. loader and hot mixing of stone aggregate and bitumen (including Cost of anti stripping compound Minimum 1% in Lime/Cement as per design wherever required) in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensing device (as per clause 504-3.5) to the required level and grade and compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa, to achieve the desired density complete as per clause 509 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion but excluding primer/tack coat. 58 Grade-II with Bitumen VG-grade 30 @ 6% (percent by weight of totalmix) 59 300 mm dia DI DF Diaphragm Type Flow Control/ Pressure Reducing Valve Pilot operated suitable for scada (PN 1.6 ) 60 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 61 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mmnominal size) 62 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mmnominal size) (As per design mix) including Providing /mixing ofsynthetic fibers compulsorily complying with IS 16481:2022 of 06mm/12 mm length to be mixed @ 0.25% by weight of Cement i.e.125 gms per 50 kg Cement up to 900 gms per cum of Concrete/mortar. 63 SITC of star rated Aluminium wound distribution Transformer of following rating 11/0.433KV Delta-Star Connected, Vector Group RUIDP 586 ISOR 2023 Code No Description Unit Rate Rs. Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & losses as defined as per 2014 (Fourth Revision) Level-1 . including standard accessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint, including carrying of pre-commission Testing & Charging of Transformer complete in all respect . The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTL of discom before charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in-charge. For additional technical parameters of products/ work , refer Annexure A attached with this BSR . 64 250 KVA with Off -LTC (+5% to - 10% @ 2.5%) 65 Centring and shuttering with plywood or steel sheet upto two stories( each story of height upto 3.5 metre from floor level) includingstrutting, propping etc. and removal of form for : 66 Foundations, footings, bases of columns, etc. for mass concrete 67 Reinforcement for R.C.C. work at all levels including straightening,cutting, bending, placing in position and binding all complete. 68 Thermo-Mechanically Treated bars 69 Supply, Testing & Commissioning of Vertical Turbine pump motor set of specified duty parameters & guaranteed efficiency of following MOC with specified capacity horizontal foot mounted TEFC squirrel cage induction motor, working on three phase AC supply with 50 Hz ± 3%, 415 V ± 10%, rated speed 1450 RPM along with column and bowl assembly, discharge head, base channel/RSJ etc. complete as per relevant IS. M.O.C.: Impeller & Sealing Rings:CF8M, Bowl & Suction Bell: CI FG 260 IS: 210 with 2% Ni , Shaft with coupling: SS 410, Column Pipe: M.S. ERW, Mechanical Seal (above 30 kW), Base Plate: MS, Line Bearing: Thordon type, Suction Strainer: S.S. 70 133 kw to 315 kw 2 Nos 225 KW 71 SupplyinganddrawingPVCinsulated&sheathedsolid/stranded copperconductormulticorecontrolcableISImarked(IS:1554)of 1.1kVgradeofapprovedmakeasperchapterE11,inexisting surfaceorrecessedconduit/casingcappingincludingmaking connections etc. as required. 72 4 core, 1.5 sq. mm. armoured 73 8 core, 1.5 sq. mm. armoured 74 8 core, 2.5 sq. mm. armoured 75 12 CORE, 1.5 sq. mm. armoured 76 PlateEarthlingasperIS:3043withcopperEarthplateofsize 600mmx600mmx3.0mmbyembodying3to4mtr.Belowthe ground level with 25 mm dia. G.I. ‘B’ class watering Pipe including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and C.C.finishedchambercoveredwithhingedtypewithlocking arrangementC.I.Cover,C.IFrameofsize300mmx300mm completewithalternatelayersofsaltandcoke/charcoal,testingof earth resistance as required. 77 Pipe Ear thing as per IS: 3043 with perforated 3.0 Mtr. Long, 40 mm dia.‘B’classG.I.Pipeincludingallaccessorieslikenut,bolts, reducer,nipple,wiremeshedfunnel,andC.C.finishedchamber coveredwithhingedtypewithlockingarrangementC.I.Cover,C.I. Frame of size 300mm x 300 mm and embodying the pipe complete withalternatelayerssaltandcoke/charcoal,testingofearth resistance as required. 78 S & Laying following size ‘B’ Class G.I.Pipe confirming to IS: 1239 P-1 (1990) with accessories for laying earth conductor/ strip/ cable in ground/ surface/ recess as required. 79 50 mm dia. 80 Providing,installation,testingandcommissioningofDiaphragm Type Pressure Gauges Dial size 150 mm glycerin filled shatterproof glass,Overrangeprotection:125%ofmaximumpressure,Material ofsensorandotherwettedparts:SStype316,Housingmaterial: Die cast aluminum 81 SITCofSoftStarterswithpanelsuppliedbymanufacturer conforming to applicable standards with logic inputs & outputs, relay outputsandanalogueoutputs,pluginI/Oconnections,displayof electricalparameters,stateofload&operatingtime,RS485serial link for connections to Modbus. 82 225 KW 83 Design,Manufacture,Supply,Installation, TestingandCommissioningofIndoortypePLC Panelofsizeapprox.800mmX500mmX 2000mm(LBH),Fabricatedoutofmin.2mm thickCRCAsheetcompletewithlatest configuration,necessaryprogrammingsoftware forPLC&SCADAandcomprisingofall accessories not limited to the following: DI 30No. DO 26No. AI 6No. AO 2No. MCB 16A DP 2No. MCB 6A DP6No. SMPS 100-240VAC/ 4.5A / 24 VDC 1No. Selector Switch (Auto/Manual) & Local / Remote2No.Control Relays1Lot Annunciatorwith24WindowsNOtoNCType MicroprocessorBased,WindowSize75*42mm, 110VAC, with1No.Electronic Hooter1No. Control Transformer 200VA1No. Emergency STOP Push Button1No. Panel Cooling Fan & Filter2No. Panel Light with Door Switch, 7W1No. Control Indication Lamp for 24VDC, 220VAC3No.Push Button3No. Power Wiring+Control Wiring + Control TB/ Fuse 2A,TB etc1Lot PanelHardware,lugs,terminations,ferruls, name plate Ect.1Lot UTILITY SOCKET 16A, 3 PIN2No. HMI Display 10 Inch, Colour1No. Isolators Dual Output, 24VDC1Lot 84 SITCofIntelligentManageableEthernetSwitchesproviding24x 10/100/1000FastEthernetports-and2dualpurposeuplink (provisionforCopper/FibreGigaconnectivity)withLANbased Software.TheLANbasedS/Wsupportsenhancedintegrated security,includingNetworkAdmissionControl(NAC),advanced qualityofservice(QoS),availabilityandscalablemanagementto enable new converged applications 85 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kAbreakingcapacity(B/C/Dtrippingcharacteristicaspertypeof loadandsiterequirement)4KVimpulsewithstandvoltage,ISI markedIS8828(1996)/conformingtoIEC60898-12002,IEC 60947-2,lowwattlosses,tripfreemechanisum,energylimitingofclass3asperIEC,minimumphaseterminationcapacityof 35sq.mm. , conductor line load reversibility , IP 20 contact protection andfittedinexistingdistributionboard/sheets,minimumelectrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A&aboveratingincludingmakingconnections,testingetc.as required. OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports&AllasperpreapprovedbyEngineerin-charge.Foradditionaltechnicalparametersofproduct/workrefer Annexure A attached with this BSR 86 Triple pole MCB(With B/C curve trippingCharacteristics), 6 A to 32 A rating 87 50/63 A rating 88 125 A rating 89 Four pole MCB (With B/C curve tripping Characteristics), 6 A to 32 A rating 90 Double pole MCB(With B/C curve tripping Characteristics) , 6 A to 32 A rating 91 Providing&FixingofselfhealingIP20MPPtypeshuntcapacitor (banks) conforming to IS:13340-41 /IEC :831-1&2 OR IEC : 60831-1&2inexistingpanelorparallelwithloadterminals,thecapacitor shallbefittedwithdischargeresistors,pressuresensitive disconnector(PSD)andshallhavedissipationfactorlessthan 0.0025 at 50 Hz, Operating loss less than 0.30 Watt per KVAR. Min overcurrentcapacity1.8timesratedcurrent&peakinrushcurrent min.300timesofratedcurrent,llifeexpectancygreaterthan 100000hrs(tempclass-25D)in440V/480VCapacitorandfor 525 V should life expectancy minimum 1,65,000 hrs (temp class - 25 D)including making connections, testing etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 92 HeavydutyThreephase440V,50Hzcylindricaltypecapacitor (Bank) 93 Providing& Fixing of IP54 microprocessor based 3CT’s for all 3 phasesensingcompensationpowerfactorcorrectionrelaySize 139mm x 139 mm, Operating Voltage 415/440 V, IEC / EN 61000-6-(2&4)having3CTsensing,sensitivityupto50milliamp secondarycurrent,selfanalysingautoc/ksettingaccordingto targeted power factor setting, the relay shall have digit displayunit fordisplayofrealpowerfactor,targetedpowerfactor,lag/lead capacitorswitchingstatus,alarmoutputforundercurrent,over current, insufficient compensation, communication interface with RS 485,indication of switching onunits, auto/manual status, and shall haveoverloadprotection,novoltrelease,havingmultiparameter like KW, KVA, KVAR, RMS Value, step switching time 2 sec to 1800 sec. Lead & Lag parameters, metering facility and3 no. Class- 0.5 Cast ResinCT ( refer CT specs in this chapter )for sensing the relay includingmakingcoonectionwith1.5Sq.mmcopperwireetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 94 6 to 8 stage 95 12 to 14 stage 96 Providing&Fixingof440Volt3polecapacitor(AC6B)duty contactor with 3 no. early make and post break auxiliary contacts in serieswithquickdischargedampingresistors/reactorstolimitthe inrush current as per PWD specification for electrical Works,IS/IEC 60947-4-1:2000,insulationvoltage1000V,impulsewithstand voltage8KV,Dinrailmountingtypeincludingmakingconnections, testingetc.asrequired.suitableforfollowingcapacitycapacitor bank.All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexureA attached with this BSR . 97 50 KVAR 98 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/freestandingfloormounteddustandverminproof compartmentalisedcubicalpanelasspecificationsandOther parameters requiredas per point (a) ,(b), (c),(d, (e), (f), (g), (h) as below:-(a)ThicknessofCRCAsheetshallbe2.0mm,cablealley compartmentshavingconcealedhingedtypedoorswithkeytype lock with / withoutdetachable extension type structure. Removable 3mm.thicksheetsteelglandplateswithappropriatesizeof knockouts for cables shall be provided(b)completepanelshallundergoaprocessofdegreasing,Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.ThepanelhavingPEfoam/Neoprenerubbergasketofnotlessthan 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) nterconnectionbetweenbusbarandswitchgears/cableshall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried outwith1.5Sq.mm,Earthwirewith2.5Sq.mmandCTwith2.5 sq.mmflexiblecopperwireonly.Alljoints/interconnectionsof copper bus bar shall be dully tinned . Clearance between main bus barandrisers/metalpartsshallbeatleast10mmadditionalto widthofbusbarBusbarisinsulatedbyHeatShrinkablesleeves. Earth and Neutral bus bar shall be half of the size of phase bus bar. (CostofBusbar/FlexiblewireforInterconnectionbetweenMain connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)FloormountedpanelshallbemountedonBaseframeofISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute)shallbemeasuredbetweenphases,betweenphaseand neutralandbetweenphaseandearth.bothbeforeandafterhigh voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out. (h) only outer surface area on all sides shall be measured & panel to befabricatedonlyfromCPRIapprovedfabricatoronly(CPRITest certificates to be submitted)All as per preapproved byEngineerin-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . busbar and Switchgearis to be Paid Extra ) (d)WiringbetweencomponentswithinswitchgearandIncoming/ outgoing cableshall be done through the terminal block only. Directconnection shall not be permitted.Each terminal block shall be onepiece moulded, barrier type, 650 volt grade, complete with washers, heads,studswithtwonutsandidentificationstripsandshallhaveadequate continuous current rating. For tap-offs, adjacent terminalswithshortingstripsshallbeused.10%Spareterminalblocksshall be provided. Wire identification on marking strip shall correspond tothedesignationofthewiringdiagrams.Allwireterminalsontheequipmentshallalsobemarkedwithdesignationcorrespondingtothose of the wiring diagram. (e)Allwiringshallbeenclosedinplasticchannelsandneatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee 99 SupplyingandfixingofAluminium(IEC60105ISO209-1,2)/ Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwithstandardshortcircuitwithstandcapacity,hightensilenuts and bolts spring washers in existing panel including bending , cutting inrequiredshapeandsizeandcolourcodingwithheatshrinkable PVCsleeves.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 100 Electrolytic grade Aluminium bus bar 6010 grade 101 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/Frequencymeter/KWHmeter/MultiFunctionMeter/ Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96mmincludingmakingconnectionbyPVCinsulatedcopper conductorwithPVCsleeves/channeletc.asrequired.Allasper preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 102 Three phase with universal Auxiliary supply + AMP + HZ + PF + KW +KVA+KVAR+KVARH+KWH+DUALENERGY+ ENERGY+THD-I, THD-V & RUN HRS + MD with RS485 103 Providing&FixingofBISapprovedCurrentTransformerasper PWD specification for electrical Works ,ISI marked as perIS 2705-1992/conformingtoIEC60044-1,withsecondaryterminalofCT shallbebroughtoutsuitabletoaterminalblockwhichshallbe easieraccessiblefortestingandterminalconnection,withall necessarysupportinexistingpanelincludingconnectionetc.as requiredCurrenttransformerRingTypeTapeWound/ResinCast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified.ISF<=5,Cucrosssectionofsecondarywire1.5sqmm (minimum),includingallnecessarysupportinexistingpanel includingconnectionetc.asrequired.Allasperpreapprovedby Engineerin-charge.AllasperpreapprovedbyEngineerin-charge. Foradditionaltechnicalparametersofproducts/work,refer Annexure A attached with this BSR . 104 C T Class 1, Ratio 400/5 to 1200/5, Burden 15 VA 105 Providing & Fixing ofCam operated rotary (Auto/manual) switches onexistingpanelwith2wayandoffpositionusinghighgrade engineeringmaterialtointernationalstandardswithcamassemblyinsulationofglassfilledpolyamidewithhightrackingindex.For reliable and stable electrical and mechanical endurance double butt contactswithsilverbi-metaloncoppershouldprovidedcontact assemblyis of operating temp range-25 degree C to55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanicallyminimum50000operations@300cycles/hourand electrically10,000operationsat100%rateddutyfor100cycles/ hourincludingmakingconnectionetc.asrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 106 10 AMP 107 16AMP 108 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947withintegralcircuit,IP65abovepanel&IP20terminal block,Approx.bodydiaforpanelnot lessthen20mm,lengthmin. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per preapprovedbyEngineerin-charge.Foradditionaltechnical parametersofproducts/work,referAnnexureAattachedwith this BSR . 109 Red/yellow/Blue 110 Red/Gree/ white Colour 111 Red/Green 112 Providing&FixingofflushheadpushbuttonactuatorsIEC60947withintegralcircuit,IP65abovepanel&IP20terminalblock, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze forLed,PCBcontactsshallbeofbrass(tinplated),impulsedielectrictestedfor2.5KV,includingconnectionetc.asrequired.AllasperpreapprovedbyEngineerin-charge.Foradditional technicalparametersofproducts/work,referAnnexureA attached with this BSR 113 Non luminous type 114 Providing & Fixing of Electricalinsulating rubber matts as per PWD specification for electrical Works, ISI marked confirming to IS: 15652 /2006 withonesideantiskidabberationmarksandpastingthe matwithsyntheticrubberadhesiveasrequired.Allasperpre approved by Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 115 11 KV,Class B 2.5 mm thick with proof voltage 22 KV AC (rms) and Break Down Voltage45 KV AC (rms) 116 SITCof3/4polecurrentlimitingMouldedcasecircuitbreaker (MCCB)madeofflameretardent&heatresistantmaterialhaving followingcurrentrating,shortcircuitbreakingcapacityat440/415 V,50Hz;O/L&S/Csettings,conformingtoIS/IEC60947P-2 :2003withfrontfaceandcentralisedadjustable,tripfree mechanisum,truecontactpositionindicator,lineload interchangeability, designed for both horizontal&vertical mounting withoutanyadverseeffectonelectricalperformance,suitablefor operationupto55degreeandwithoutderatingupto40degree,pollution degree 3, having positive isolation capability, push(test) totrip,triptimelessthen10msunders/ccondition,Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock&rotaryhandle,includingmakingconnectionsetc.as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in-charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 117 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 118 Extended Rotary Handle 119 Mechanical Interlocking kit 120 Auxiliary + Trip alarm contact 121 Spreaders for 400A, 4 Pole MCCB 122 Providing&LayingP.V.C./XLPEinsulated&P.V.C.sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - Iof1.1KVwithH4-Gradeelectrolyticaluminiumconductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC /Hume/Stoneware/PVCpipe/openduct/cabletrench/Cable tray(withcabletie)includingtestingetc.asrequiredoffollowing size.OEMmusthaveitsowninhouseNABLaccrediated LaboratoryfortestingprocedureasperIS:10810.Foradditional technicalparametersofproduct/workreferAnnexureAattached with this BSR 123 300 SQMM,3.5 CORE 124 120 SQMM,3.5 CORE 125 4.0 SQMM, 3 CORE 126 50 SQMM, 3 CORE 127 Supply,Fabricating&installingfollowingsizesofperforatedHot dippedGalvanizedironcabletray(Galvanizedthicknessnotless then 50 microns) with perforation not more then 17.5% in convenient sectionincludinghorizontalandverticalbends,reducerstees,cross membersandotheraccessoriesasrequiredanddulysuspended fromtheceilingwithGIsuspendersincludingGIbolts&nuts, fastners,supportsetc.asrequired.Allasperpreapprovedby Engineer in-charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 128 100mm x 50mm x 1.6mm 129 150mm x 50mm x 1.6mm 130 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4-GradeelectrolyticaluminiumconductorconfirmingtoIS:8130 class-2ofpurity>99.6%,InsulationScreening:Extruded SemiconductingCompoundfollowedbyhelicallywrappedCopper Tape,round/flatstriparmouringofcables,Inner/outersheath PVCtypeST-2confirmingtoIS:5831inexistingRCC/Hume/ Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in houseNABLaccrediatedLaboratoryfortestingprocedureasper IS:10810AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 131 3 core 95.0 Sq.mm 132 Providing&makingheatshrinkabletypeindoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test reportshouldbeasperIS13573:2011whichcoveredallsequence fortable2forterminationkitandtable3forstreightthroughjoint inclusive thermal & dynamic short circuittest, humiditytest, soil fog test.CrosslinkingshallbedoneoutsidefactorywithE-beam/ peroxidetechnology.ExtrusionprocessshallbeinhouseOEM withinsamevicinity.includingtestingetc.asrequiredoffollowing sizes. All as per pre approved by Engineer in-charge. For additional technicalparametersofproducts/work,referAnnexureA attached with this BSR . 133 3 core 50/70/95 Sq.mm 134 3 core 50/70/95 Sq.mm 135 Supply&Layingfollowingsizeearthstripinhorizontalorvertical runinsurfacebymeansofEarthstripDMCInsulatorincluding riveting/soldering/welding,Jointingshallbedonebyoverlapping andwith2setofBrass(forCustrip)/GI(forGIStrip)nutbolt& springwasherspacedat50cmmakingconnectionetc.as required.AllasperpreapprovedbyEngineerin-charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 136 25mm x 6mm G.I. ( Hot Dipped) Strip 137 32mm x6mm G.I. ( Hot Dipped) Strip 138 50mm x 6mm G.I. ( Hot Dipped) Strip 139 Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level. M10 grade Nominal Mix 1: 3: 6 (1 cement : 3 coarse sand : 6 graded stoneaggregate 20mm nominal size). 140 Providing and laying in position specified grade of cement concrete for all RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix 141 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers (if required ) excluding the cost of centering, shuttering and reinforcement for Walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. M20 grade Nominal Mix / Design Mix 142 Providing and laying in position specified grade of cement concrete for RCC structural elements upto floor five level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement for Beams, suspended floors, roofs, griders having lopes up to 15º, landings, balconies, shelves, chajjas, lintels, bands, plain windows sills, staircases and spiral staircases etc. M20 grade Nominal Mix / Design Mix 143 Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings, strap beam, raft , bases of columns etc. 144 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc. 145 Centering & shuttering with plywood or steel sheets including strutting, propping bracing both ways with steel propsand removal Suspended floors, roofs, landings, staircases, balconies, girders, cantilevers, bands, coping bed plates,anchorblocks,sills,chhajjas,lintel,beam, plinth beam etc.of formwork for upto floor five level for_Columns, pillars, posts and struts etc. 146 Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor three level.(Original producers who manufactura billet directly from iron ores and roll the billets to produce steel conforming to IS:786) Thermo-mechanically Treated bars (Tata, SAIL) 147 Random Rubble stone masonry forwith hard stone in foundation and plinth in Cement Sand mortar above 30 cm thick wall in : Cement Mortar 1 : 6 (1-Cement : 6-Sand). 148 5.2 Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in : 5.2.1 Cement mortar 1 : 4 (1 cement : 4 coarse sand) Cum. 5196.00 149 Plaster on new surface on walls in cement sand mortar 1:4 including racking of joint etc. complete fine finish : 20 mm thick 150 6 mm cement plaster to ceiling of mix 1 : 3 (1 cement : 3 fine sand). 151 Providing and applying white cement based puttyover plastered surface to prepare the surface even and smooth completeNew Plastered Surface (three or more coats) 152 Finishing walls with textured exterior paint of required shade as per approved colour complete as per manufacturers specifications including primer coat and protecting coat including scaffolding and safety provision. Trowel Finish av. thickness 2000 to 2500 microns. 153 Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. 154 Painting with syntheticenamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work. 155 O&M cost for 10 year 156 For the 1st Year of O&M after DLP 157 For the 2nd Year of O&M after DLP 158 For the 3rd Year of O&M after DLP 159 For the 4th Year of O&M after DLP 160 For the 5th Year of O&M after DLP 161 For the 6th Year of O&M after DLP 162 For the 7th Year of O&M after DLP 163 For the 8th Year of O&M after DLP 164 For the 9th Year of O&M after DLP 165 For the 10th Year of O&M after DLP