| 1 | Cleaning the septic tank/ sludge chamber of any depth/ area/ condition incl taking out stagnated sludge or any other material mixed with the sludge etc. deposited in the septic tanks, filling in closed container and depositing in excavated pit, covering the pit at least 500m beyond nearby living accn or area as marked by station controlling authority with earth after depositing sludge, sprinkling fresh lime on covered pit and around septic tanks/ soakage wells to make it hygienic complete all as specified and directed.Note:- (i) Cost of pumping with mechanical sewage pump, excavation of earth pit and fresh lime shall be deemed to include in the rate quoted. (ii) Charges of covered container incl its transportation shall be deemed to include in the rate quoted. (iii) Depth of liquid sludge in the septic tank will be determined and recorded before commencement of work by any Engg conventional method in the presence of Engr-in charge and Contractor. |
| 2 | Comprehenshive maintenance and cleaning of sewage system including sewage lines, manholes, soakage wells/soak-pits, gully traps, septic tanks attending bloakages in WCs/ WHBs/Drains etc by employing necessary resources including T&P, complete all as specified and directed. The location/ building/complex where work is to be carried out consist of the following:-(a) All OTM and Md Accn at Jutogh Cantt. .Notes:- (i) The Contractor will employe a Supervisor. The Supervisor so employed shall report to the concerned JE daily to give feed back and also to receive day to day sewage complaints and necessary instructions for smooth running of the contract. (ii) He will carry out normal maintenance to sewage system as required at site. (iii) For any default/delay in attending the complaints recovery shall be effected as per contract conditions provided here-in-after. (iv) T & P as requiered for the work shall be arranged by the contractor without any extra cost to the deptt. (v) Supervisor engaged by the contractor shall take all necessary preventative safety measures and adequate precautions to avoid any health hazard and department shall not be held responsible for any unwanted incidence. |
| 3 | Comprehenshive maintenance and cleaning of sewage system including sewage lines, manholes, soakage wells/soak-pits, gully traps, septic tanks attending bloakages in WCs/ WHBs/Drains etc by employing necessary resources including T&P, complete all as specified and directed. The location/ building/complex where work is to be carried out consist of the following:-(a) All OTM and Md Accn at MH Shimla,Sanjauli,Kufri & Shimla. .Notes:- (i) The Contractor will employe a Supervisor. The Supervisor so employed shall report to the concerned JE daily to give feed back and also to receive day to day sewage Complaints and necessary instructions for smooth running of the contract. (ii) He will carry out normal maintenance to sewage system as required at site. (iii) For any default/delay in attending the complaints recovery shall be effected as per contract conditions provided here-in-after. (iv) T & P as requiered for the work shall be arranged by the contractor without any extra cost to the deptt. (v) Supervisor engaged by the contractor shall take all necessary preventative safety measures and adequate precautions to avoid any health hazard and department shall not be held responsible for any unwanted incidence. |
| 4 | Cleaning ofdrainof any shape and size ofremoving sludge, soil, mud, grass and vegetation roots removing from site to distance exc 50 m etc., complete all as specified and directed. |
| 5 | M&L for cutting of grass, shrubs, vegetation, bush weed by brush cutter operated slasher where ever required including removing waste of material obtained from cutting and cleaning (both side) from the edge of drain& bldg surrounding area and removal of spoil beyond 250 mtr but not exceeding 500 mtr and deposited where as directed complete all as specified and as directed.Notes:- (i) Contractor will arrange his own 02 brush cutter machines and minimum 02 operator & 02 helper with POL per day comprises of 08 hours working including lunch break of 0.50 hours. (ii) The minimum output of brush cutter for one day is 150 Sqm, hence area of 150 Sqm will be after removal of spoil up to the entire satisfaction.(iii) Site for brush/grass cutting will be given by MES authority as per their requirement through out the contract period. |
| 6 | Removing spot blockage of WC/ Nahani trap/ gully trap incl cleaning of sewage line/ manholes up to and incl 1st manholes and disposal of material obtaining from cleaning to a distance exc 200m, complete all as specified and directed. |
| 7 | Repair to trap leakage/ seepage of EWC \"P\"/ \"S\" trap by filling hollow space with white/ grey cement as per site requirement, complete all as specified and directed. |
| 8 | Excavation in trenches in hard /dense soil n exc 1.5 m wide and n exc 1.5 m in deep for pipes etc and for manholes not exc 10 Sqm on plan and not exc 1.5 m deep and getting out complete all as specified and directed. |
| 9 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. |
| 10 | Removing excavated material exc 200m but not exc 250 m and depositing where directed etc complete all as specified and directed. |
| 11 | Demolition and breaking up to 150mm dia drain pipes below ground level (salt glazed stoneware, AC or reinforced concrete and PVC) set in cement mortar incl PCC at any depth complete all as specified and directed. |
| 12 | M&L for salt glazed stone ware drain pipe laid in trenches and jointed all as specified (internal dia of pipe 150mm bore pipe) complete all as specified and directed. |
| 13 | M&L for 150mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors and tested including fittings of same grade, complete all as specified and directed. |
| 14 | M&L for PCC 1:4:8, type D-2, using 40 mm graded crushed stone aggregate as in concrete bed to drain pipes laid to falls in trenches in any depth including packing under and haunching against the sides of 150 mm bore (salt glazed ware, AC, reinforced concrete) pipes with concrete after the pipes are laid and tested, complete all as specified and directed. |
| 15 | Cutting into existing manholes for connecting new drain making good to pipes and rendering, cutting out existing benching for forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B-1 finished smooth good to pipe complete to match with the existing works all as specified and directed for 150mm dia pipe, complete all as specified and directed. |
| 16 | Taking up or down 15mm bore, steel water tubing & connections complete all as specified and directed. |
| 17 | S&F steel water tubing medium grade galvanised with all fittings and fixed complete to walls, ceiling or laid in floors of 15mm bore, complete all as specified and directed. |
| 18 | M&L for cutting chases, pinning in brick walls making good to facings where required and pointing in cement motar 1:3, to ends or edges of landings, steps, cills, sunshades, shelves, lintels, etc and cutting chases for concealed water tubing or concealed conduit wiring etc. and making good, cutting n exc. 10cm girth, complete all as specified and directed. |
| 19 | S&F in repair stop valve/Angle cock/concealed fancy type cast copper alloy 15mm bore screwed down high pressure chromium plated concealed type, complete all as specified and directed. |
| 20 | S & F in repair 15mm bib tap cast copper alloy chromium plated with crutch or butterfly handle screwed down screwed for iron pipe or for brass ferrule and fixed complete all as specified and directed. |
| 21 | S&F in repair Brass with CP finished,Jet spray with flexible pipe of suitable length fixed to 15mm bore pipe (faucet) complete all as specified and directed. |
| 22 | S&F in repair vitreous china wash hand basin white flat back or angle back type size 600mm x 480 mm white inclwaste pipe and prop stopper but incl cutting for and pinning in ends of brackets or erecting stand fixed,complete all as specified and directed. |
| 23 | Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone work and precast concrete articles, complete all as specified and directed. |
| 24 | M&L for brick work with sub class \"B\" bricks old size straight or curved on plan built in CM 1:4, complete all as specified and directed. |
| 25 | M&L for brick work with sub class \"B\" bricks old size straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete but except brick/ stone, complete all as specified and directed. |
| 26 | M&L for brick work with sub class ‘B’ bricks in one brick thick honey comb walling, built in Cement mortar 1:4, complete all as specified and directed. |
| 27 | M&L for walling of random rubble stone masonry, brought upto courses, well bonded, bedded and solidly hearted built in cement mortar 1:6including raking or cutting outjoints complete all as specified and directed. |
| 28 | All as per item No 27.00 above but \"except stone\", complete all as specified anddirected. |
| 29 | M&L for 15mm thick Rendering in CM 1:4 mixed with water proofing compound on brick work or concrete surfaces finished even and smooth without using extra cement, complete all as specified and directed.complete all as specified. |
| 30 | Supply only integrated water proofing compound, complete all as specified and directed. |
| 31 | M & L for broken brick bat loose filling in soakage pits/filter beds etc., complete all as specified and directed. |
| 32 | Demolition of cement concrete is reinforced (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided, complete all as specified and directed. |
| 33 | M&L for Precast reinforced concrete 1:2:4, type B-1 using 20 mm graded crushed stone aggregate as in cover slabs set in cement concrete 1:4 placed in position over manholes etc including use and waste of necessary formwork complete all as specified and directed.Note: - Reinforcement and handles shall be measured and paid seperately. |
| 34 | M&L for TMT bars 10mm dia and over cut to length bent to shape required and binding with ms wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 35 | M&L for TMT bars 6 to 8mm dia and over cut to length bent to shape required and binding with ms wire (annealed) not less than 0.9 mm dia or securing with clips, complete all as specified and directed. |
| 36 | Dismantling of 100mm cast iron or reinforced concrete drain pipe, jointed in cement mortar and taking out of trenches/floor/wall if required, complete all as specified and directed. |
| 37 | S&F for 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed. |
| 38 | S&F for 100 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall, complete all as specified and directed. |
| 39 | S&F in repairs CI bends (any radius) diminishing pieces or tapers (large bore measured) 100 mm dia with oval access door, complete all as specified and directed. |
| 40 | Dismantling 75 mm Cast iron or reinforced concrete drain pipes, jointed in cement mortar and taking out of trenches/floor/wall if required, complete all as specified and directed. |
| 41 | S&F for 75 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, laid in trenches or in floors, complete all as specified and directed. |
| 42 | S&F for 75 mm bore cast iron soil, waste and vent pipes in any length with or without ears, with cement joints, fixed to wall, complete all as specified and directed. |
| 43 | S&F in repairs CI bends (any radius) diminishing pieces or tapers (large bore measured) 75 mm dia with oval access door, complete all as specified and directed. |
| 44 | Taking down PVC pipe of any dia and description including all fitting, complete all as specified and directed. |
| 45 | S&F PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and directed. |
| 46 | S&F for PVC (SWR) pipes 110mm dia single socketed, in any length with rubber ring joints, laid in trenches, complete all as specified and directed. |
| 47 | S&F PVC\"S\" traps of 110 mm bore pipe, complete all as specified and directed. |
| 48 | S&F PVC SWR cowl 110 mm bore pipe, complete all as specified and directed. |
| 49 | S&F PVC (SWR) bends any radius 110 mm, complete all as specified and directed. |
| 50 | S&F PVC (SWR) bends any radius 110 mm dia provided with access door, complete all as specified and directed. |
| 51 | S & F PVC (SWR) junction single, (Single T) equal or unequal 110 mm dia complete all as specified and directed. |
| 52 | S&F PVC (SWR) couplers 110 mm dia complete all as specified and directed. |
| 53 | S&F for PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, laid in trenches or in floors, complete all as specified and directed. |
| 54 | S&F for PVC (SWR) pipes 75mm dia single socketed, in any length with rubber ring joints, fixed to wall, complete all as specified and directed. |
| 55 | S&F PVC (SWR) bends any radius 75 mm dia, complete all as specified and directed. |
| 56 | S&F PVC (SWR) bends any radius 75 mm dia provided with access door, complete all as specified and directed. |
| 57 | S&F PVC (SWR) couplers 75 mm dia, complete all as specified and directed. |
| 58 | S & F PVC (SWR) junction single, (Single T) equal or unequal 75 mm dia, complete all as specified and directed. |
| 59 | S&F 75mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement, complete all as specified and directed. |
| 60 | S&F in repair wash down water closet (pedestal pattern) complete with vitreous China wash down water closet pan (pedestal pattern) white (excluding fixing bolts flushing cistern and flush pipe) etc., complete all as specified and directed. |
| 61 | S & F in repair plastic water closet seat cover, closed pattern with flat bottom and cover and mild steel chromium plated of aluminium hinging device, complete all as specified and directed. |
| 62 | S&F in repairs vitreous china squatting pan, Orrissa, pattern, size 580 x 440 mm white with integral foot rest including trap set and including concrete etc (excluding flushing cistern and flush pipe, complete all as specified and directed. |
| 63 | S&F in repairs 10 litres capacity PVC low level valve less symphonic action type flushing cistern white with inlet, ball valve, float and handle including brackets and flushing pipe or PVC pipe 32 mm dia etc., complete all as specified and directed. |
| 64 | S&F in repair PVC connection 15 mm dia and 45cm long with 2 Nos brass nuts at both ends, complete all as specified and directed. |
| 65 | S& F in repair 32mm dia PVC waste pipe for wash hand basin and kitchen sink of length 900mm long with PTMT nuts complete all as specified and directed. |
| 66 | S&F in repair CP grating doom 100mm dia complete all as specified and directed. |
| 67 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. |
| 68 | M&L for Non - skid Ceramic coloured tiles 7 to 8 mm thick (square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.11 Sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match the tile including 15 mm thick screed bed or bedding layer of cement mortar 1:6, complete all as specified and directed. |
| 69 | M&L for glazed ceramic-coloured tiles 350x250x7mm/ 300x200x7mm thick laid pattern as in skirting dado riser to steps etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the colour tile laid over and including 10mm thick rendering in CM 1:4 complete all as specified and directed. Note: Colour of tile will be approved by GE. |
| 70 | Demolition of cement concrete in ground floors and paving’s n exc 15 cm thickness (below or above ground level, complete all as specified and directed. |
| 71 | M&L for PCC 1:2:4, type B-1, using 20mm graded crushed stone aggregate as in surface channel/ drains inside the manholes and the like incl weathering, slightly rounded or chamfered angles and throating as directed including use and waste of necessary formwork complete all as specified and directed. |
| 72 | M&L PCC 1:3:6, type C-2, using 40mm graded crushed stone aggregate as in foundation of man hole, plinth courses etc including formwork complete all as specified and directed. |
| 73 | M&L for 1:2:4, type B-1, using 20 mm graded crushed stone aggregate as in bands, coping plinth coarse etc including necessary formwork, complete all as specified and directed. |
| 74 | M&L 75mm thick PCC 1:4:8, type D-2, using 40mm graded crushed stone aggregate as in subbase of flooring, complete all as specified and directed. |
| 75 | M&L for chequered cement concrete tiles pre polished with lacquer finish 30cmx30cmx22-25mm thick, over 20mm thick screed bed in CM (1:6) set jointed and pointed in neat cement slurry as in floors and steps etc with grey cement and pigment complete all as specified and directed. |
| 76 | Demolition of cement concrete unreinforced of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 77 | Supply only Liquid water proofing compound, complete all as specified and directed. |
| 78 | M&L for rendering/ screed bed 15mm thick in CM 1:3 in (Sunken slab) with water proofing compound as per manufacturer instruction\"s surface shall be finished even and smooth without extra cement, complete all as specified and directed.Note:- Water proofing compound will be measured and paid separately. |
| 79 | M&L for applying evenly a tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per Sqm including cleaning surfaces etc complete as in sunken portion, complete all as specified and directed. |
| 80 | M&L for PCC 1:5:10, type E-2, using 40mm graded crushed stone aggregate as in filling and mass aggregate complete all as specified and directed. |
| 81 | S&FRCC precast factory made perforated type M-20 design mix, H D Drain cover 1000x450x100mm, incl nessary pcc for packing & joint fillings etc., complete all as sepecified and directed. |
| 82 | S&FRCC precast factory made type M-20 design mix MH covers without frame size 900x600x100mm etc complete all as sepecified and directed. |
| 83 | S&FRCC precast factory made type M-20 design mix MH covers without frame size 1200x300x100mm etc complete all as sepecified and directed. |
| 84 | Dismantlingwrought iron or mild steel work of any description not otherwise provided complete all as specified. |
| 85 | S&F Framed work as in steel gate, in such as grills gratings etc with ends of bars shouldered and or riveted or forged into spikes;framed guard bars barred iron doors ladders framed balusters walk ways railings frame work of water tanks and similar work conforming to Fe 290.Gde -E-165 including all fittings and fixtures etc., complete all as specified and directed. |