}

Tender For Supply Of Arthroscopic Instrument, sevagram-Maharashtra

Mahatma Gandhi Institute Of Medical Sciences has published Tender For Supply Of Arthroscopic Instrument. Submission Date for this Tender is 02-08-2025. Medical Equipment Tenders in sevagram Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

50119699
Tender For Supply Of Arthroscopic Instrument
Tender
Indian
Maharashtra
Sevagram
02-08-2025

Tender Documents

Tender Details

Supply Of Arthroscopic Instrument , Supply Of Arthroscopic Instrument , Arthroscope With Trochar Sheath :30 Degree 4 Mm Compatible With Existing System (Should Be Compatible With Smith & Nephew System) , Arthroscope With Trochar Sheath :70 Degree 4 Mm. Compatible With Existing System Smith & Nephew. , Knee Probe: Callibrated Hand Held Instrument Need Specifically For Knee Arthroscopy , Shoulder Probe: Callibrated Hand Held Instrument Need Specifically For Shoulder Arthroscopy , Acl Reconstruction Drill Bits: Drill Bits Of Size- 6 Offse Of Size - 6.5 Mm. Compatible With Present System Smith & Nephew. , Acl Reconstruction Drill Bits: Drill Bits Of Size- 7Mm, Offse Of Size - 6.5 Mm. Compatible With Present System Smith & Nephew. , Acl Reconstruction Drill Bits: Drill Bits Of Size- 8 Mm, Offse Of Size - 6.5 Mm. Compatible With Present System Smith & Nephew. , Acl Reconstruction Drill Bits: Drill Bits Of Size- 9 Mm, Offse Of Size - 6.5 Mm. Compatible With Present System Smith & Nephew. , Acl Reconstruction Drill Bits: Drill Bits Of Size- 10 Mm, Offse Of Size - 6.5 Mm. Compatible With Present System Smith & Nephew. , Acl Reconstruction Drill Bits: Drill Bits Of Size- 11 Mm, Offse Of Size - 6.5 Mm. Compatible With Present System Smith & Nephew. , Endobutton Reamer : 4.5Mm. Compatible With Existing System Smith & Nephew. , Suture Retriever Cum Grasper.: (Suture Retriever Cum Grasper Specially Design Instruments That Can Retrieve And Can Grasp Suture Optimal Tool For Arthroscopic Tissue Grasping/Reduction, Foreign Body Removal, And Suture Retrieval/Management. The Distal Serrated Tip Of The Jaws Functions As A Tissue And Suture Grasper, While The Proximal Section Of The Jaws Facilitates Slide-Through Suture Retrieving.Autoclavable.) , Knee Scorpion : The Single Portal, Reusable Meniscus Suture Passer With Low Profile 5 Degree Up Curve Tip And 3.2Mm Narrow And 4.6Mm Width Shaft And 13 Cm Shaft Length, It Must Be A Reusable And Autoclavable Device To Be Used With Disposable Needle And Should Be Able To Pass And Retrieve Suture In One Step. The Suture Passer Should Have Ability To Pass 0 Or 2-0 Uhmwpe Suture Or 0.9 Mm Uhmwpe Tapes- , Shoulder Traction System :(3 Point Traction System For Shoulder Positioning In Arthroscopy ) , Fibertape Cutter : (Reusable Suture Cutter Flat With 3.4Mm Diameter Designed Specifically For Cutting Of Uhmwpe Tapes And Total Length 13 Cm) , Acl Zig For All Inside Technique: 1)Universal Handle With Simple Wheel Locking Mechanism For One Handed Adjustment Of Making Hook At Desired Position Should Accommodate Multiple Drill Sleeves For Retrograde Reaming And Antegrade Reaming With Feature Of Side Release Mechanism To Disengage Easily From The Drill Sleeve In Open/Arthroscopic Ligament Reconstruction. 2) Tibial Acl Marking Hook For Retro Construction Drill Guide With 8-10 Mm Wide Tip With 7-8 Mm Pin Exit From Cross Hair Laser Mark. 3) 3.5Mm Stepped Drill Sleeve For Creating Sockets The Drill Sleeve Optionally Can Act As A Depth Stop For Retrograde Drilling. 4) A Racheting Drill Sleeve For Retro Construction Drill Guide, 2.4 Mm For Entry Point In Bony Footprint And Caliberated In Order To Measure Intraosseous Tunnel Lengths During Arthroscopic Ligament Reconstructions. 5) Femoral Foot Print Acl Marking Hook For Retro Construction Drill Guide To Be Used From Lateral Portal For Making Anatomic Tunnel Having 7-8Mm Round Tip To Visualize Socket Before Drilling And Has Boh Options As Right And Left. , Switching Stick And Cannula Dilator For Shoulder Surgery: 1) A Reusable Stainless Steel Stick Of 4 Mm Diameter And 16 Inch Length With Blunt Pointed End To Avoid Damage Of Delicae Structures. 2)A Reusable Sharp Distal End Obturator For Facilitation Of Easy Entry Of 6.25Mm Diameter Cannula In Arthroscopic Portals With Similar Color Coded Handle As That Of 6.25 Cannula Color In Order For Easy Identification. 3)A Reusable Sharp Distal End Obturator For Facilitation Of Easy Entry Of 8.25 Mm Diameter Cannula In Arthroscopic Portals With Similar Color Coded Handle As That Of 8.25 Cannula Color In Order For Easy Identification. , Meniscus Root Repair Zig: Meniscus Root Repair Point-To-Point Guide.It Should Allow To Directly Target Their Drill Location At The Meniscal Root Footprint, While The Over-The -Back Marking Hook Sits Securely Over The Back Of The Tibia To Allow Stable Drilling Tunnel Preparation Can Inbuilt Change 0 To 40 Deg Left Right.

Key Value

Document Fees
Refer document
EMD
INR 20000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail