| 1 | ABT meter with facility for AMR and compliant to CEA technical standard for Special Energy Meter (SEM) |
| 2 | Supervisory Interface cubicles (SLC) panel for mountain MFTs, relays etc |
| 3 | Data Converter Unit (DCU) |
| 4 | 24 Port L-3 LAN Switch for Management LAN |
| 5 | Copper Control Cable 12 Core x 2.5 sq.mm |
| 6 | Laptop for maintenance |
| 7 | Router cum firewall |
| 8 | Anti Virus Software for all machines |
| 9 | Information Storage & Retrivel (ISR) with redundancy |
| 10 | ISR Server with Auxilary Memory and Data Historian Sever |
| 11 | Report development and Generation Software |
| 12 | SAN Box |
| 13 | SAN Management Server |
| 14 | NAS Box |
| 15 | Tape Library |
| 16 | Tower type Videowall |
| 17 | Multi-Point Conferencing Unit |
| 18 | Common Meter Reading Instrument (CMRI) |
| 19 | Web Server Application |
| 20 | Host based IDS for all machines & Software for Data Replica server |
| 21 | Software for Centralised Management System |
| 22 | Software for Web Server |
| 23 | Document Management System & Identity Management System |
| 24 | EMS Functions :Power System Applications |
| 25 | State Estimation , Contingency Analysis, Optimal Power Flow, Outage Scheduler , Load Forecasting and Inflow Forecasting |
| 26 | PART B :IMPLEMENTATION OF SUBSTATION AUTOMATION SYSTEM (SAS) |
| 27 | Remote Terminal Unit and its accessories |
| 28 | Remote Terminal Unit |
| 29 | RTU base equiqment comprising panels, racks, sub-racks,Power Supply modules, Communication modules, interfacing equipment, required converters & all required items/accessories including complete wiring for all modules. |
| 30 | Splitter for RTU Communication |
| 31 | SCADA for SAS |
| 32 | MODEMs |
| 33 | Weather sensor |
| 34 | OLTC transducer |
| 35 | Heavy Duty Relay |
| 36 | Contact Multiplaying Relay (CMRs) |
| 37 | Time Synchronisation equipment without display |
| 38 | CPU |
| 39 | Analog Input Module |
| 40 | Digital InputModule |
| 41 | Digital OutputModule |
| 42 | LDMS system along with software |
| 43 | Furniture for LDMS system (one table and one chair) |
| 44 | Inverter |
| 45 | Comprehensive Integration of new bays in the RTU & control centres (Main, Back-up & ERLDC) including supply of MFT, cables, CMR etc/any hardwares |
| 46 | Power Cable |
| 47 | DCPS to DCDB (2 Core, 20 mm2) |
| 48 | DCDB to battery Bank (2 Core, 20 mm2) |
| 49 | DCDB to RTU Panel(2 Core, 2.5 mm2) |
| 50 | ACDB to RTU panel (4 Core, 2.5 mm2) |
| 51 | Cables for each C&R panels connection with RTU |
| 52 | RTU Panel to C & R Panel(14 Core, 2.5 mm2) |
| 53 | Cat 6 for MFT/ ABT Meter |
| 54 | 2.5mm/7C-DI Lv Side (copper) |
| 55 | 2.5mm/4C for DO (Trip/Close)(copper) |
| 56 | Conduit |
| 57 | Test Equipment for RTU |
| 58 | Master Station cum RTU simulator & Portocol Analyser |
| 59 | Laptop PC for above software tools alongwith interfacing hardware |
| 60 | SDH Equipment (STM - 4 MADM, upto 3 MSP protected direction) |
| 61 | Base Equipment (Common Cards, Cross-connect/ Control cards, Optical base card, Power Supply cards, power cabling, other hardware & accessories including sub-racks, patch cords, DDF etc. fully equipped including Cabinet etc. |
| 62 | Optical Interface S4.1 |
| 63 | Optical Interface L4.1 |
| 64 | Optical Interface L4.2 |
| 65 | Optical Line Interface <150KM |
| 66 | Optical Line Interface upto 250 km |
| 67 | E1 Interface Card (Minimum 63 nos) |
| 68 | Ethernet interface 10/100 Mbps with Layer-2 switching (Minimum 16 nos) |
| 69 | Drop & Insert Multiplexer |
| 70 | 2 wire (sub/sub) voice channel card |
| 71 | 2 wire (sub/exch) voice channel card |
| 72 | 4 wire (E&M) voice channel card |
| 73 | Asynchronous Sub Channel data card |
| 74 | Synchronous Data Card (Nx64 kbps), minimum 4 channels per card |
| 75 | Synchronous Data Card Nx64 kbps |
| 76 | Router Board with min 4 Ports |
| 77 | Digital Access Cross Connect Switch (DACS) , 16x16 ports matrix, full equipped for minimum 16E-1 ports |
| 78 | Equipment Cabinets for SDH equipment, primary multiplexer, drop/insert and DACS |
| 79 | Software/Hardware (remote) |
| 80 | Software/Hardware (craft terminal) |
| 81 | Digital Protection Coupler suitable for integration and operation through OPGW System with required Cables, complete in all respect. |
| 82 | Pre Connectorized Optical Fibre Patch Cords (10 mtrs)-Pack of six(6) patch cord |
| 83 | IP Phone |
| 84 | GPRS based Modem for data connectivity from RTU to SLDC (For Control Location) |
| 85 | Industrial grade 16 ports serial server,230V AC Power Input (19\" Rack mount type) |
| 86 | Ethernet Module |
| 87 | Wan Router cum firewall for connectivity with ISP |
| 88 | 6U rack |
| 89 | For remote location (Grid Sub-Stations) |
| 90 | RTU site equipments: Industrial grade GPRS based Cellular server, one RS232 Port, one no.10/100 Ethernet port,IP 30 Protected Case support DTU functions, routing Firewall |
| 91 | 48V DC to 12V DC Supply |
| 92 | Fiber Optic Approach Cable and Accessories |
| 93 | Fibre Optic approach cable, 24 Fibre (DWSM) |
| 94 | Hardware set for above 24 fibre, Fibre Optic Approach Cable |
| 95 | Joint Box (24Fibre) as per technical requirement |
| 96 | G.I Pipe 4\" Heavy Duty |
| 97 | Laying of 48/24 OPGW cable on 220KV, 132KV,66KV including splicing fixing of hardware accessories |
| 98 | Laying of PLB HDPE pipe O.D. 40mm |
| 99 | Services related to data integration |
| 100 | Integration with control centres on ICCP |