}

Tender For Construction Of Sosmess (With 45 Rooms For Accommodating Single Living Assistant Sub-Inspectors) At 13Th Bn, Itbp Force, Lingdum, P.O.- Ranka, Gangtok, Sikkim-737101 - Civil, Electrical, E&M Items 2 Earth Work In Surface Excavation Not Exc, Gangtok-Sikkim

Indo Tibetan Border Police Force has published Tender For Construction Of Sosmess (With 45 Rooms For Accommodating Single Living Assistant Sub-Inspectors) At 13Th Bn, Itbp Force, Lingdum, P.O.- Ranka, Gangtok, Sikkim-737101 - Civil, Electrical, E&M Items 2 Earth Work In Surface Excavation Not Exc. Submission Date for this Tender is 01-08-2025. Paver Blocking Tenders in Gangtok Sikkim. Bidders can get complete Tender details and download the document.




Tender Notice

50110327
Tender For Construction Of Sosmess (With 45 Rooms For Accommodating Single Living Assistant Sub-Inspectors) At 13Th Bn, Itbp Force, Lingdum, P.O.- Ranka, Gangtok, Sikkim-737101 - Civil, Electrical, E&M Items 2 Earth Work In Surface Excavation Not Exc
Tender
Indian
Sikkim
Gangtok
01-08-2025

Tender Documents

Tender Details

Tender For Construction Of Sosmess (With 45 Rooms For Accommodating Single Living Assistant Sub-Inspectors) At 13Th Bn, Itbp Force, Lingdum, P.O.- Ranka, Gangtok, Sikkim-737101 - Civil, Electrical, E&M Items 2 Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge:All kinds of soil 3 Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge. All kinds of soil 4 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. 5 Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. 6 Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. 7 Supplying chemical emulsion in sealed containers including delivery as specified.Chlorpyriphos/ Lindane emulsifiable concentrate of 20% 8 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% With Chlorpyriphos/ Lindane E.C. 20% with 1% concentration 9 Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) : Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor:With Chlorpyriphos/Lindane E.C. 20% with 1% concentration 10 Providing and laying in position cement concrete of specified grade1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size) 11 Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20mm nominal size derived from natural sources). 12 Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturers specification. 13 Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with apiece of cloth lightly soaked in kerosene oil. 14 Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. 15 Providing and laying in position ready mixed or site batched design mix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the minimum specified cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level :Concrete of M10 grade with minimum cement content of 220 kg /cum 16 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level.Concrete of M25 grade with minimum cement content of 330 kg /cum 17 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works upto plinth level.Concrete of M30 grade with minimum cement content of 350 kg /cum 18 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site Mof laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for thefollowing grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level.Concrete of M25 grade with minimum cement content of 330 kg /cum 19 Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.All works above plinth level upto floor V level.Concrete of M30 grade with minimum cement content of 350 kg /cum 20 Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). 21 Extra for rendering smooth the top of suspended floors, landings and staircases (treads and risers) with cement mortar 1:2 (1 cement : 2 coarse sand), including a floating coat of neat cement and protecting the surface with a layer of 7.5 cm of earth laid over 15 mm of fine sand in case of suspended floor and bricks laid in mud mortar in case of landings and steps, including subsequent removal and cleaning of the same. 22 Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections. 23 Centering and shuttering including strutting, propping etc. and removal of form for :Foundations, footings, bases of columns, etc. for mass concrete 24 Centering and shuttering including strutting, propping etc. and removal of form for :Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. 25 Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform 26 Centering and shuttering including strutting, propping etc. and removal of form for :Shelves (Cast in situ) 27 Centering and shuttering including strutting, propping etc. and removal of form for :Lintels, beams, plinth beams, girders, bressumers and cantilevers 28 Centering and shuttering including strutting, propping etc. and removal of form for :Columns, Pillars, Piers, Abutments, Posts and Struts 29 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. 30 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. 31 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:Cement mortar 1:4 (1 cement : 4 coarse sand) 32 Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) 33 Providing and laying Autoclaved Aerated concrete (AAC) blocks masonry 150mm/230mm/300 mm thick with Grade- I AAC blocks in super structure above plinth level up to floor V level with RCC band at sill level and lintel level with approved block laying polymer modified adhesive mortar all complete as per direction of Engineer-in-Charge. (The payment of RCC band and reinforcement shall be made for seperately). 34 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level.Cement mortar 1:4 (1 cement :4 coarse sand) 35 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third course of half brick masonry. 36 18 mm cement plaster in two coats under layer 12 mm thick cement plaster 1:5 (1 cement : 5 coarse sand) finished with a top layer 6 mm thick cement plaster 1:6 (1 cement : 6 fine sand). 37 12 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) 38 6 mm cement plaster of mix :1:3 (1 cement : 3 fine sand) 39 Extra for plastering exterior walls of height more than 10 m from ground level for every additional height of 3 m or part thereof. 40 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. 41 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 42 With water thinnable cement primer of approved brand and manufacture on wall surface :Water thinnable cement primer 43 Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour complete, as per manufacturers specification.Two or more coats on new work 44 Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :Two or more coats on new work 45 Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied @ 2.20kg/10 sqm 46 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work 47 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab upto 0.50 sqm 48 Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels Granite of any colour and shade Area of slab over 0.50 sqm 49 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.Granite work 50 Extra for providing opening of required size & shape for wash basin/ kitchen sink in kitchen platform, vanity counter and similar location in marble/ Granite/ stone work, including necessary holes for pillar taps etc. including moulding, rubbing and polishing of cut edges etc. complete. 51 Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete. 52 Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete. 53 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand) Acid and alkali resistant tile 54 Providing and fixing 10 mm thick acid and/or alkali resistant tiles of approved make and colour using acid and/or alkali resisting mortar bedding, and joints filled with acid and/or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in- Charge.In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile 55 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) 25 mm thick 56 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. 57 Providing and laying rectified Glazed Ceramic floor tiles of size 300x300 mm or more (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick Cement Mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including pointing the joints with white cement and matching pigments etc., complete. 58 Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 800 x 1600 mm 59 Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).Sal wood 60 Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters.35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws 61 Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance±1mm), with wall thickness 2.0 mm (± 0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s specification and direction of Engineerin- charge.Extruded section profile size 42x50 mm 62 25 mm thick PVC flush door shutters made out of a one piece Multi chamber extruded PVC section of the size of 762 mm X 25 mm or less as per requirement with an average wall thickness of 1 mm (± 0.3 mm). PVC foam end cap of size 23x10 mm are provided on both vertical edges to ensure the overall thickness of 25 mm. M.S. tube having dimensions 19 mm x 19 mm and 1.0 mm (± 0.1 mm) is inserted along the hinge side of the door. Core of the door shutter should be filled with High Density Polyurethane foam. The Top & Bottom edges of the shutter are covered with an end-cap of the size 25 mm X 11 mm. Door shutter shall be reinforced with special polymeric reinforcements as per manufacturer’s specification and direction of Engineer-in-charge to take up necessary hardware and fixtures. Stickers indicating the locations of hardware will be pasted at appropriate places 63 Providing and fixing factory made uPVC white colour sliding glazed window upto 1.50 m in height dimension comprising of uPVC multi-chambered frame with in-built roller track and sash extruded profiles duly reinforced with 1.60 ± 0.2 mm thick galvanized mild steel section made from roll forming process of required length (shape & size according to uPVC profile), appropriate dimension of uPVC extruded glazing beads and uPVC extruded interlocks, EPDM gasket, wool pile, zinc alloy (white powder coated) touch locks with hook, zinc alloy body with single nylon rollers (weight bearing capacity to be 40 kg), G.I fasteners 100 x 8 mm size for fixing frame to finished wall and necessary stainless steel screws etc. Profile of frame & sash shall be mitred cut and fusion welded at all corners, including drilling of holes for fixing hardwares and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealent over backer rod of required size and of approved quality, all complete as per approved drawing & direction of Engineer-in-Charge. (Single / double glass panes, wire mesh and silicon sealent shall be paid separately). Variation in profile dimension in higher side shall be accepted but no extra payment on this account shall be made.Note: For uPVC frame and sash extruded profiles minus 5% tolerance in dimension i.e. in depth & width of profile shall be acceptable.Three track three panels sliding window with fly proof SS wire mesh (Two nos. glazed & one no. wire mesh panels)made of (small series) frame 92 x 44 mm & sash 32 x 60 mm both having wall thickness of 1.9 ± 0.2 mm and single glazing bead of appropriate dimension (Area of window upto 1.75 sqm). 64 Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with :5.5 mm thick glass panes 65 Providing & fixing ACP Sheet with EPDM rubber gasket in groove of meeting Style clips in Aluminium doors, windows, clerestory windows,Partition all complete with :5.0 mm thick ACP Sheet 66 Providing and fixing Fiber Glass Reinforced plastic (FRP) Door Frames of cross-section 90 mm x 45 mm having single rebate of 32 mm x 15 mm to receive shutter of 30 mm thickness. The laminate shall be moulded with fire resistant grade unsaturated polyester resin and chopped mat. Door frame laminate shall be 2mm thick and shall be filled with suitable wooden block in all the three legs. The frame shall be covered with fiber glass from all sides. M.S. stay shall be provided at the bottom to steady the frame. 67 30 mm thick Fiberglass Reinforced Plastic (F.R.P.) flush door shutter in different plain and wood finish made with fire retardant grade unsaturated polyester resin, moulded to 3 mm thick FRP laminate all around, with suitable wooden blocks inside at required places for fixing of fittings and polyurethane foam (PUF)/Polystyrene foam to be used as filler material throughout the hollow panel, castedmonolithically with testing parameters of F.R.P. laminate conforming to table - 3 of IS: 14856, complete as per direction of Engineer-in-charge. 68 Providing and fixing IS : 12817 marked stainless steel butt hinges (heavy weight) with stainless steel screws etc. complete :125x64x2.50 mm 69 Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete :250x10 mm 70 Providing and fixing bright finished brass night latch of approved quality including necessary screws etc. complete. 71 Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete.125mm 72 Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete. 73 Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868),transparent or dyed to required colour or shade, with nuts and screws etc. complete :300x16 mm 74 Providing and fixing ISI marked brass sliding door bolts with nuts and screws etc. complete 300x16 mm 75 Providing and fixing cup board shutters 25 mm thick, with Pre-laminated flat pressed three layer particle board or graded wood particle board IS: 12823 marked, exterior grade (Grade l Type ll), having one side decorative lamination and other side balancing lamination, including IInd class teak wood lipping of 25 mm wide x12 mm thick with necessary screws and bright finished stainless steel piano hinges, complete as per direction of the Engineer-in-Charge 76 Providing and fixing bright finished brass butt hinges with necessary screws etc. complete :125x85x5.5 mm (heavy type) 77 Providing and fixing bright finished brass parliamentary hinges with necessary screws etc. complete 150x125x27x5 mm 78 Providing and fixing of the MAC/VISTA/Hunter Douglas vertical Roller blinds with shade/screening and material complete with all acessories in all respect as per approved fabric/colour and texture 79 Providing and fixing wooden moulded beading to door and window frames with iron screws, plugs and priming coat on unexposed surface etc. complete :2nd class teak wood 50 x 20 mm 80 Providing and fixing false ceiling at all height including providing and fixing of frame work made of special sections, power pressed from M.S. sheets and galvanized with zinc coating of 120 gms/sqm (both side inclusive) as per IS : 277 and consisting of angle cleats of size 25 mm wide x 1.6 mm thick with flanges of 27 mm and 37mm, at 1200 mm centre to centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50mm long with 6mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required length with nuts & bolts of required size and other end of angle hanger fixed with intermediate G.I. channels 45x15x0.9 mm running at the spacing of 1200 mm centre to centre, to which the ceiling section 0.5 mm thick bottom wedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centre to centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels 0.5 mm thick 27 mm high having flanges of 20 mm and 30 mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25mm long dry wall screws @ 230 mm interval, including fixing of gypsum board to ceiling section and perimeter channel with the help of dry wall screws of size 3.5 x 25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and square edges of the board with recommended jointing compound , jointing tapes , finishing with jointing compound in 3 layers covering upto 150 mm on both sides of joint and two coats of primer suitable for board, all as per manufacturers specification and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed, all complete as per drawings, specification and direction of the Engineer in Charge but excluding the cost of painting with :12.5 mm thick tapered edge gypsum plain board conforming to IS: 2095- (Part I) :2011 (Board with BIS certification marks) 81 Providing and Fixing 15 mm thick densified tegular edged eco friendly light weight calcium silicate false ceiling tiles of approved texture of size 595 x 595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main ‘T’ runner suitably spaced at joints to get required length and of size 24x38 mm made from 0.33 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross “T” of size 24x28 mm made out of 0.33 mm (Minimum) sheet, 1200 mm long spaced between main’T’ at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross ‘T’ of length 600 mm and size 24 x28 mm made of 0.33 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x24X3000 mm made of 0.40 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and laying 15 mm thick densified edges calicum silicate ceiling tiles of approved texture in the grid, including, cutting/ making opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc., wherever required. Main ‘T’ runners to be suspended from ceiling using G.I. slotted cleats of size 25x35x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm G.I. adjustable rods with galvanised steel level clips of size 85 x 30 x 0.8 mm, spaced at 1200 mm centre to centre along main ‘T’, bottom exposed with 24 mm of all Tsections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by Engineer-in-Charge. 82 Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing C wall angle of size20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :GI Metal Ceiling Clip in plain Beveled edge global whitecolor tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation. 83 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-incharge, (for payment purpose only weight of stainless steel members shall be considered excluding fixing accessories such as nuts, bolts, fasteners etc.). 84 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets,gates and similar works 85 Grading roof for water proofing treatment withCement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) 86 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @ 0.70 kg per sqm 87 Providing and applying integral crystalline slurry of hydrophilic innature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI- 212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm. 88 Providing gola 75x75 mm in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 stone aggregate 10 mm and down gauge), includingfinishing with cement mortar 1:3 (1 cement : 3 fine sand) as per standard design :In 75x75 mm deep chase 89 Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stoneaggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. 90 Providing & fixing GRC panel (60mm thick) on external walls as per the architectural drawing. Fixing to be done on external wall including the necessary SS clamps, scaffoldings required etc. complete by specilised vendor in strict supervision of manufacturer as per direction of Engineer-in-Charge. 60 MM THICK 91 Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick colour toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/ beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured. 92 Providing and fixing 12 mm thick frameless toughened glass Door with all hardware of approved brand and manufacture,including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-char 93 Cement concrete pavement with 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), including finishingcomplete. 94 1:5:10 (1 cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal sizederived from natural sources) 95 Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-60mm thick cement concrete paver block of M-35 grade with approved colour, design & pattern. 96 Providing and fixing 6 mm thick frameless toughened glass partation with all hardware of approved brand and manufacture,including providing and fixing top & bottom pivot & spring type fixing arrangement and making necessary holes etc. for fixing required door fittings, all complete as per direction of Engineer-in-char 97 Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid 98 Providing, fixing, testing and commissioning of star white colour vitreous china below / over counter Oval Wash Basin / circular basin (Size 560 x 410 mm or as/architectural detail drawing) with CP brass waste assembly complete including CI / MS brackets duly painted, cutting and making good the walls floors wherever required. 99 Providing, fixing, testing and commissioning of CP brass bottle trap with wall connection pipe for wash basins.32 mm dia 100 Providing and fixing 600 x 450mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete in all respect 101 Providing and fixing C.P. brass towel ring with C.P. brass wall brackets & C.P brass screws complete in all respect 102 Providing and fixing 15mm C.P. copper connecting pipe 450mm long with C.P. brass nuts, washers complete In all 103 Providing and fixing C.P. soap dish of approved make including providing & fixing screws, washers, cutting & making good the walls. 104 Providing and fixing toilet paper holder.C.P. brass 105 Providing and fixing CP brass twin coat hooks fixed on toilet door/wall with CP brass screws, complete in all respect 106 Providing and fixing stainless steel kitchen sink as per I.S.13983 with C.I brackets and stainless steel plug 40mm including painting of fittings and brackets, cutting and making good the walls wherever required complete in all respect Kitchen sink with drain board 510 x 1040 bowl depth 200 mm 107 Providing, fixing, testing and commissioning of C.P. brass single hole sink mixer with CP wall flange, swinging spout complete as required and making good. 15 mm nominal dia. 108 Providing, fixing, testing and commissioning of white glazed vitreous china semi-stall lipped Urinal CI hangers CP spreader, 32/40 mm CP brass domical waste and pipe to wall with CP flange, automatic flushing system with concealed type electic operated, waterproof compact model solenoid valve with built in strainer, flow control mechnaism, stainless steel outer case, pre flush and main flush function and low battery indication, for individual urinals to ensure flushing only when in use, comprising of all plumbing & any other item required to provide satisfactory functioning as approved by the Architects complete including cutting and making good the walls and floors where required. (The gap between fixture and wall to be filled up with approved type poly sulphide sealant) Set of One urinal with flushing system. Urinal of size 580x380x350 mm or as/final architectural drawings. 109 Providing, fixing, testing and commissioning of CP brass bottle trap with wall connection pipe for urinals. 40 mm dia 110 Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth. Granite Stone of approved shade 111 Providing and Fixing, testing & commissioning of ABS Health Faucet (complete with hook and flexible tube min. Length 1.0 m) as required complete in all respect 112 Providing & fixing chrome plated brass battery based infrared sensor operated pillar cock, having foam flow technology. 15 mm nominal bore 113 Providing and Fixing, testing & commissioning C.P.brass wash basin mixer 15 mm nominal bore 114 Providing and Fixing in position 15 mm C.P. brass bib cocks of best quality (as approved by theProject manager). Bib cock long body 115 Providing and fixing & commissioning of position storage type automatic electric water heater pressure/ non pressure type themostratically controlled single phase, vertical wall mounted of approved make (to the approval of Engineer - in - charge) with thermostats, inner container of stainless steel complete with 1 Mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. 25 litre capacity water heater 116 Providing and fixing & commissioning of position storage type automatic electric water heater pressure/ non pressure type themostratically controlled single phase, vertical wall mounted of approved make (to the approval of Engineer - in - charge) with thermostats, inner container of stainless steel complete with 1 Mtr three core flexible cord with plug, non return valve and pressure release valve complete including fixing and testing complete in all respect. 50 litre capacity water heater 117 Providing and Fixing, testing & commissioning of C.P. brass Twin way bib cock of approved quality conforming to IS standards 15 mm nominal bore 118 Providing and Fixing, testing & commissioning of C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. 15 mm nominal bore 119 Providing and Fixing, testing & commissioning of C.P. brass towel rail fixed to rawl plug with C.P. brass screws. (600 mm long) Towel Rail 120 Providing and Fixing, testing & commissioning wall mixer with head shower & shower arm. Divertor + Spout + Shower Head 121 Providing and fixing liquid dispenser including all fittings complete. 122 Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 110 OD 123 Providing, fixing and jointing UV stabilized SWR (Type - B) pipes conforming to IS:13592 including all fittings such as bends, clamps, tees, cowls, clean out plugs, offsets, Y-tees, tees, door fittings, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 160 OD 124 Providing and fixing in position uPVC SWR floor trap conforming to IS:13592 including providing necessary steel support and as per Specification. Making proper connection cutting chase / hole in floors / slabs and bringing the same in proper condition and shape after placing the trap in right position complete as required. The hopper and trap shall be set in cement concrete mix 1:2:4 complete as required. 100 mm inlet and 100 mm outlet. 125 Providing & fixing PVC EXTENSION PIECE for 100 mm dia floor trap formed out of main pipe(Type A) with multiple side inlets, suitable for various dia pipes, side connections, including all fixtures and fittings as per site conditions and as per standard 126 Providing and fixing Heavy Class SS grating with Cockroach proof SS strainer of approved design including setting in floor with cement motor to match with floor finish as per architect requirement suitable for waster and FT. Size 100 mm X 100 mm 127 Providing and fixing Heavy Class SS grating with of approved design including setting in floor with cement motor to match with floor finish as per architect requirement .(for Bacony or floor Drain 128 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 40 mm od uPVC pipe 129 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 50 mm od uPVC pipe 130 Providing & fixing and jointing UV stabilized uPVC pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees,, offsets, Y-tees, tees, clips, clamps, stays etc. conforming to IS-14735, including jointing with rubber gasket fixing in sunk areas, Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/ holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 63 mm od uPVC pipe 131 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 160 mm diameter (I) Single socketed pipes 132 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 110 mm diameter (I) Single socketed pipes 133 Providing, fixing and jointing UV stabilized uPVC rain water pipes conforming to IS:4985 (working pressure 6 kg/sqcm.) including all fittings such as bends, clamps, tees, cowls, clean out plugs etc including Fixing at wall / ceiling level supported by steel clamps & hangers etc. including Cutting, chases/holes in floors / walls / slab and making good the same after pipe have been duly laid and testing complete in all respects. 63mm diameter (I) Single socketed pipes 134 Providing , fixing / installation, testing and commissioning of 110 mm dia straight / offset Push fit type syphon uPVC WC pan connector with neoprene rubber ring and necessary accessories etc., complete. 135 Providing and fixing clean out plug comprising of uPVC caulked to UPVC pipes complete as required. 110 mm dia 136 Providing and fixing clean out plug comprising of uPVC caulked to UPVC pipes complete as required. 160 mm dia 137 Providing and fixing UPVC floor drain for balcony including all fitting and accessories fixed in cement mortar complete in all respect. 63 mm OD x 50 mm OD 138 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: 1:2:4 (1 cement :2 coarse sand: 4 hard stone aggregate 20mm and down gauge). 139 Providing and making Khurras with average minimum thickness of 5 cm Cement Concrete 1:2:4(1 Cement: 2 Coarse Sand: 4 Graded Stone Aggregate 20 mm nominal size) over PVC sheet 1 m x 1 m (PVC 400 microns min. thickness), finished with 12 mm Cement Plaster 1:3 ( 1 Cement : 3 Coarse Sand, admixed with waterproofing compound) and a coat of neat cement, rounding the edges and making & finishing the outlet complete Khurras Size 300 x 300 mm, for 110 OD/160OD outlet with 5 mm thick circular /Square horizontal or vertical C.I. grating. 140 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 15 mm dia nominal bore 141 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 20 mm dia nominal bore 142 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 25 mm dia nominal bore 143 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 32 mm dia nominal bore 144 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work - Exposed on wall 40 mm dia nominal bore 145 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) SDR-11 pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm dia nominal bore 146 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 15 mm dia nominal bore 147 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 20 mm dia nominal bore 148 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 25 mm dia nominal bore 149 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 32 mm dia nominal bore 150 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 40 mm dia nominal bore 151 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 50 mm dia nominal bore 152 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 65 mm dia nominal bore 153 Providing and fixing, testing and commissioning of GI pipes Class-C and fittings conforming to IS:1239 (heavy class) complete with GI fittings (union and clamps including cutting holes in wall, makes chases in wall and making good the same in cement mortar 1 : 2 (1 cement : 2 coarse sand) as directed by Project Manager, complete in all respects for internal works) including pipe supports with galvanised MS slotted angle iron, clamps, spacers as required and making good where required. Internal work - Exposed on wall 80 mm dia nominal bore 154 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 15 mm dia nominal bore 155 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 20 mm dia nominal bore 156 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 25 mm dia nominal bore 157 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 32 mm dia nominal bore 158 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 40 mm dia nominal bore 159 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 50 mm dia nominal bore 160 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 65 mm dia nominal bore 161 Painting of exposed pipes with two or more coats of synthetic enamel paint of approved quality over a coat of red oxide zinc cromate primer including painting of legends in English with direction arrows. 80 mm dia nominal bore 162 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 15 mm dia. 163 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 20 mm dia. 164 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 25 mm dia. 165 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 32 mm dia. 166 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 40 mm dia. 167 Providing & fixing full way lever operated forged brass ball valve of brass body with forged brass hard chrome plated steel ball tested to a pressure not less than 10 Kg / sqcm with threaded / flanged joints complete with nuts, bolts, gaskets, washers etc. 50mm dia. 168 Providing and fixing Solenoid valve with float type sensors suitable for 240 volts with working pressure rating of not less than 5 kg/cm2 with control panel and sensors to open valve when water level is low in tanks and to close when water level is high in water tanks including necessary cables, conduits, upto junction box etc., complete. 25mm dia. 169 Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required. 65 mm dia. 170 Providing and fixing Butter fly valve with nitrile seat and stainless steel stem with lever operation and cast iron body in powder coated finish, suitable for test pressure of 10Kg/sq.mm) with flanges, gaskets and necessary pad locking arrangement complete required. 80 mm dia. 171 Providing and fixing air release valve 15 mm dia 172 Providing and fixing 3 layer HDPE sintex tank on Teerace floor as per specification 3KL 173 Providing and fixing 3 layer HDPE sintex tank on Teerace floor as per specification 5KL 174 Excavating trenches of required width for pipes, cables, etc including excavation for sockets, and dressing of sides, ramming of bottoms, depth up to 1.5m including getting out the excavated soil, and then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc. and disposing of surplus excavated soil as directed, within a lead of 50m Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. 175 Extra over for item no. 1.1 excavating trenches for pipes, cables etc. in all kinds of soil for depth exceeding 1.5 m, but not exceeding 3 m. (Rate is over corresponding basic item for depth up to 1.5 metre) Pipes, cables etc. exceeding 80mm dia. But not exceeding 300mm dia. 176 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes withcollars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. complete 150 mm dia R.C.C pipe 177 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes withcollars jointed with stiff mixture of cement mortar in the proportion of 1:2(1 cement : 2 fine sand) including testing of joints etc. Complete 250 mm dia R.C.C pipe 178 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) up to haunches of S.W./RCC pipes including bed concrete as per standard design : 150 mm dia R.C.C pipe 179 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 20 mm nominal size) up to haunches of S.W./RCC pipes including bed concrete as per standard design : 250 mm dia R.C.C pipe 180 Constructing brick masonry manhole cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix ( 1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making necessary channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 90 x 80 cm and 45 cm deep including C.I. cover with frame (light duty) 455 x 610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg) With F.P.S. bricks with class designation 75 181 Constructing brick masonry manhole cement mortar 1:4 (1 cement : 4 coarse sand) R.C.C. top slab with 1:2:4 mix ( 1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ), foundation concrete 1:4:8 mix (1cement : 4 coarse sand : 8 graded stone aggregate 20 mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with floating coat of neat cement and making necessary channels in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement complete as per standard design. Inside size 120x90 cm and 90 cm deep including C.I. cover with frame (medium duty) 500 mm internal diameter, total weight of cover and frame to be not less than 116 kg (weight of cover 58 kg and weight of frame 58 kg) : With F.P.S. bricks with class designation 75 182 Extra depth for manholes Size 90 x 80 cm (With With F.P.S. bricks with class designation 75) 183 Size 120 x 90 cm (With With F.P.S. bricks with class designation 75) 184 Constructing brick masonry road gully chamber 50x45x60 cm with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal grating with frame complete as per standard design: With F.P.S. bricks 185 Extra depth beyond 45 cm of brick masonry chamber For 455 x 610 mm size With F.P.S. Bricks 186 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design: 100x100 mm size P type With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 187 Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steel bar conforming to IS : 1786 having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufactures permanent identification mark to be visible even after fixing, including fixing in manholes with 30 x 20 x 15 cm cement concrete block 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) complete as per design. 188 Material & labour for constructing R.C.C. Grease trap of size 2000mm x 1200mm x 2500mm deep with RCC walls with inlet & outlet including necessary excavation and foundation concrete 100mm thick in 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate of 20mm nominal size), inside plaster 12mm thick in cement mortar 1:4 (1 cement : 4 coarse sand) finished with a floating coat of neat cement, RCC base slab, roof slab & baffle walls including reinforcement, centering & shuttering including 12mm dia steel bar footrests etc. and SFRC manhole cover and frame of 600mm x 450mm internal dimension conforming to IS: 12592 (total weight of cover & frame shall not be less than 70 kg) 189 Supply, instattation, Engineering, Testing and Commissioning of sewerage treatment plant all items to include providing all materials and its assembly, Labour, Consumables etc. as per standards and specifications, approved shop drawings at site.Sewage Treatment Plant (STP) using Moving Bed Bio Reactor (MBBR) or DRDO based Bio-Digester of capacity 10 KLD in civil construction and releted works including Design, Engineering, and preparation of providing all equipment / Piping etc at site, erection testing and 190 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A 191 Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required. Group A 192 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 193 Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 194 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire (For Light Plug Wiring) 195 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 6 sq. mm + 1 X 6 sq. mm earth wire (For Single Phase DB. From Sub Panel to DB) 196 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 6 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 197 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 10 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 198 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 4 X 16 sq. mm + 2 X 6 sq. mm earth wire (For Three Phase DB. From Sub Panel to DB) 199 Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. 200 Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. 201 Supplying and fixing suitable size GI box with modular plateand cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. 202 Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 A & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. 203 Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required. Upto 450 mm sweep 204 Extra for fixing the louvers/ shutters complete with frame for a exhaust fan of all sizes. 205 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 25 mm 206 Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. 32 mm 207 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Telephone socket outlet 208 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. TV antenna socket outlet 209 Supplying and drawing co-axial TV cable RG-6 …. in the existing surface/ recessed steel/ PVC conduit as required. 210 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 211 Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair 212 Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 6 way, Double door 213 Supply and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator). 8 way, Double door 214 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator).6 way (4 + 18), Double door 215 Supplying and fixing following way prewired TP&N MCB distribution board of steel sheet for 415 volts on surface/ recess complete with loose wire box, terminal connectors for all incoming and outgoing circuits, duly prewired with suitable size FR PVC insulated copper conductor up to terminal blocks, tinned copper bus bar, neutral link, earth bar, din bar, detachable gland plate, interconnections, powder painted including earthing etc. as required.(But without MCB/ RCCB/ Isolator) 8 way (4 + 24), Double door 216 12 way (4 + 36), Double door 217 Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB where 3 phase outlets are required.) TPDB is normally used 4 way (4 + 12), Double door 218 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 219 Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. 220 Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 32 amps 221 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 222 Supplying and fixing following rating, four pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 223 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 25/32 amps 224 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 amps 225 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current upto 300 milliamperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 amps 226 Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32amps 415 volts C curve TP MCB complete with connections, testing and commissioning etc. as required. 227 Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 228 Supplying and fixing 30 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 229 Installation ,Testing, Commissioning of wall bracket /ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connections etc. as required. 230 Supply and installation of Kitchen Chimney with baffle filter, Stainless Steel, i/c Ducts for exhaust upto outer wall, push button operations, LED lights inclusive, noise(<60db), Exhaust area length x width (500 cmx 500cm) Exhaust motor rpm 2000 , V 220 W, >3500 cfmetc of approved brand as per directed by Engineer-in-charge. 231 Supply of 20 watt LED Tube Light rod, 4 long suitable with 40000 burning hours for rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply with aluminium alloy base,, frosted polycarbonate diffusers with power factor >0.90, Total Harmonic Distortion (THD) < 20%, system current - 0.085A, system efficiency > 85% , with operating temp. -10° C to 45° C, Lumen output for LED tube should be > 2000 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED>80% with correlated colour temperature (CCT) of 6500K , minimum burning hour life >40000 hours,LED viewing angle 120 Degree complete in all respect with the entire satisfaction of the Engineer-in-incharge. Supply of Industrial General Purpose 4 long tube fitting suitable to house 1x20w LED tube rod 4 long, Polycarbonate housing , rated voltage 240 V and Ingress protection IP-20 complete in all respect with the entire satisfaction of the Engineer-in-incharge. 232 Bulkhead Light. 233 Wall Bracket Light. 234 Supply of 20 watt LED FLAMEPROOF Tube Light rod, 4 long suitable with 40000 burning hours for rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply with aluminium alloy base,, frosted polycarbonate diffusers with power factor >0.90, Total Harmonic Distortion (THD) < 20%, system current - 0.085A, system efficiency > 85% , with operating temp. -10° C to 45° C, Lumen output for LED tube should be > 2000 lumen and overall lumen/watt of luminaire should be greater than 80%, C.R.I. of LED>80% with correlated colour temperature (CCT) of 6500K , minimum burning hour life >40000 hours,LED viewing angle 120 Degree complete in all respect with the entire satisfaction of the Engineer-in-incharge. Supply of Industrial General Purpose 4 long tube fitting suitable to house 1x20w LED tube rod 4 long, Polycarbonate housing , rated voltage 240 V and Ingress protection IP-20 complete in all respect with the entire satisfaction of the Engineer-in-incharge. 235 Bollared Light. 236 LED exit signage Light. 237 Supply of recess mounting 15 W LED down light with high efficient LED’s, CCT-5700k -500 K,CRI >80,System lumen 100lm/W, Lumens ≥ 1000, single piece pressure die cast powder coated housing with opal diffuser for glare free & uniform lighting, Driver shall be of constant current type, operating temperature from -10 to +45degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 238 Supply of 9 W mirror light with high efficient LED’s, CCT-6500 K,CRI >70, Lumens ≥800, with Ingress protection IP-20, Driver shall be of constant current type, operating temperature from -10 to +45 degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 239 Supply of recess mounting 10 W LED down light with high efficient LED’s, CCT-5700k -500 K,CRI >80,System lumen 100lm/W, Lumens ≥ 1000, single piece pressure die cast powder coated housing with opal diffuser for glare free & uniform lighting, Driver shall be of constant current type, operating temperature from -10 to +45degree celcius, power factor>0.90, rated voltage 220-240V AC working range:- 140-270 V Ac , 50 Hz +_ 5%, AC supply. Surge protection - Inbuilt 2.5KV. Complete in all respect with the entire satisfaction of Engineer-in-Charge. 240 Lamp Post Light. Make- Philips 241 Pendant Light. Make- Philips 242 Supply of 1200mm ceiling fans complete with double ball bearing, motor, blades, canopies, capacitor etc. suitable for operation on 230 volts, 50 Hz., 1 phase, AC supply with 5 star rating complete as required. ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required. 243 Supplying of Plastic Body Ornamental Exhaust Fan heavy duty 230V A.C 50 cycles, 300 mm sweep, 1300 rpm, energy efficient, complete erected in position with all accessories. 244 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness 245 Supplying and installing following size of perforated Hot DippedGalvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 300 mm width X 50 mm depth X 1.6 mm thickness 246 MAIN LT PANEL-1 Design, fabrication, assembly, wiring and supply of front operated dead front cubicle type compartmentalised as per Form 3B, rear access free standing, dust and vermin proof (IP 42 ingress protection) main switchboards suitable for use at 415 volts, 3 phase 4 wire 50 Hertz system suitable for a symmetrical fault level of 25 kA at 415 volts, fabricated from 2 mm thick CRCA MS sheets with hinged, gasketted (metal based neoprene) and lockable doors having structural reinforcement with suitable angle/channel/T/flat sections including 3 mm thick gland plates on top and bottom and including lifting hooks and including GI earth strip of required size with 2 nos earthing terminals and including powder coated paint finish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications, as required and as below. (Note:The contractor may select the next higher fault rating of MCCB if it is not readily available ,without any extra cost ,as the figure indicated within the bracket are required maximum fault level of the panel.) A INCOMER FRPM EXISTING SUPPLY;- 1 No. 400A 4P MCCB (36 KA) with electronic releases (O/C, S/C, E/F) 1 Set - digital multifunction meter (showing harmonics along with all other electrical parameters such as voltage, current, Hz, KW, KWHr, PF.) 1 Set - 0-500V, digital Voltmeter with selector switch, 3 No. phase indicating LED lamp to show the incoming power with control SP MCB. 3 nos. indicating LED lamps for On/Off/ Trip with protective SP MCBs. 1 Set of CTs of the ratio630/5A for APFC Relay, Burden 15 VA ,1 Set of CTs of the ratio630/5A for APFC Relay, Burden 15 VA, 1 Set of CTs of the ratio630/5A with class 0.5 Accuracy for Metering, burden 15 VA , 1 Set of CTs of the ratio630/5A with class 0.5 Accuracy for Metering, burden 15 VA, 1 Set of. 400/5A , 15 VA, 5P10 CTs for Protection, 300 amps TPN Aluminium Busbar. BUSBARS - All busbars and interconnections shall be of suitable size Al strips current density of Al shall not be more than 0.8 Amps/ sq.mm. OUTGOINGS- 12 Nos. 63A (36kA) 4P MCCB., 4 Nos. 40A (36kA) 4P MCCB. ,4 Nos.32A (36kA) TPN MCB, 2 Nos.32A (10kA) DP MCB, MAIN LT PANEL as described above. Design, manufacture, supplying, fixing in position, testing and commissioning of the following front operated cubicle type, front access 2mm thick mild steel sheet, free standing, dust and vermin proof, switchboard with IP42 protection with hinged and lockable doors complete with interconnections, tinned copper crimping lugs, bonding to earth and painting, suitable for use at 415 volts, 3 phase 4 wire 50 Hz system and suitable for a fault level of 25 MVA symmetrical at 415 volts. 247 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium3.5 C x 185 sq. mm 248 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. AluminiumSupplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 120 sq. mm 249 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 50 sq. mm 250 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 185 sq. mm 251 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 120 sq. mm 252 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 50sq. mm 253 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 16 sq. mm 254 Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. Aluminium 3.5 C x 10sq. mm 255 Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 256 Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. 257 Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. 258 Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required. 259 Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required. 260 Providing and fixing of lightning conductor finial, made of 25 mm dia 1200 mm long, copper tube, having single prong at top , with 85 mm dia 3 mm thick copper base plate including holes with insulation etc. complete as required. 261 Providing and fixing Copper Lightning Tape in Horizontal/Vertical Run: Providing and fixing copper tape 20mm X 3 mm thick on parapet or surface of wall for lightning conductor complete as required. 262 Providing and fixing Testing Joint for Copper Lightning Conductor: Providing and fixing testing joint made of 32 mm X 6 mm thick copper strip, 125 mm long with 4 nos. of tinned brass bolts, nuts, check nuts and spring washers etc. complete as required. 263 Providing and laying G.I. tape 32 mm X 6 mm from earth electrode directly in ground as required. 264 Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, central processing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 ± 5% V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two Loop Panel. 265 Supplying, installation, testing & commissioning of repeater panel wih 320 character/ Touch screen LCD display with inbuilt reset, acknowledge and silence switches complete as required. 266 Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 267 Supplying, installation, testing & commissioning of response indicator on surface/recessed MS Box having two LED, metallic cover complete with all connections etc as required. 268 Supplying, installation, testing & commisssioning of intelligent addressable programmable sounder complete as required. 269 Supplying, installation, testing & commissioning of fault isolator complete with base as required. 270 Supplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required. 271 Supplying, installation, testing & commissioning of addressable fire control module complete as required. 272 Supplying, installation, testing & commissioning of addressable phone control module complete as required. 273 Supplying, installation, testing & commissioning of addressable manual call point complete as required. 274 Supplying, installation, testing & commissioning of addressable horn cum strobe complete as required. 275 Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 276 Supplying, installation, testing & commissioning of fire fighter phone jack complete as required. 277 Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 278 Supplying, installation, testing & commissioning of 1.5/3/6W ceiling speaker complete as required. 279 Supplying, installation, testing & commissioning of ceiling/wall mounted loud speaker, 3/1.5 Watt in ABS enclosure complete as required. 280 Supplying, installation, testing & commissioning of digital audio amplifier 50 Watt, 25V rms operating at 240 volt AC supply complete as required. 281 Supplying, installation, testing & commissioning of Voice command keypad 6 zone, with microphone assembly complete as required. 282 Supply, installation, testing and commissioning of 25 mm Outer dia CPVC PIPE with end caps including making air sampling opening of appropriate dia on appropriate interval and all accessories as required,(rate for area protected in sqm). 283 Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 284 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Two pair, 2-core, 1.5 sqmm 285 Supplying and fixing 25 mm dia MS flexible pipe with PVC coating along with all ancillaries and accessories like coupler etc. as required.

Key Value

Document Fees
Refer document
EMD
INR 2210141.0 /-
Tender Value
INR 12.10 Crore /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail