| 1 | Dismantling of interlocking tiles of any description and any thickness and removing from site complete all as specified and directed. |
| 2 | Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness. (Below or above ground level) and removing rubbish off premisses of MOD land not exc 500 m complete all asdirected. |
| 3 | M&L for Plain cement concrete (1:4:8) type D-2 using 40mm graded stone agregate as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge. |
| 4 | M&L for brick work using sub class B brick curved or straight on plan exc 6 mtr mean radius built in CM (1:6) including demolition ofBrick/stone works masonry, built in cement mortar or cement limemortar including all quoins, arches, pillars etc but excludingashlar facing, dressed stone work andpre-cast concrete articles complete all as specified and as directed by Engr-in-Charge. |
| 5 | Material & labour for 15 mm thick rendering on other than fair faces of brick work or concrete surfaces,inCM(1:4)surface finished even and smooth without using extra cement complete all as specified and directed. |
| 6 | M&L for preparation of new plasterredsurfaces of any description, not other wise described over 10cm width or girth and apply two coat of synthetic enamel paint over a coat of pink primer complete all as specified and directed. |
| 7 | M&L for anti fungus 60 mm thick factory made machine pressed precast concrete interlocking paver block with grey cement and pigment any shape and size confirming to IS 15658-2006, M35 Grade, laid over sand complete all as specified and directed.NOTE :- Make & pattern as approved by GE.Sand shall be measured and paid seperately under respective item. |
| 8 | All as per item 7 here-in-before but except tiles .(Interlocking tiles shall be used as obtained from Item No 1 here-in-before) |
| 9 | M & L for sand filling under floors or in foundations including watering and consolidation as required complete all as specified and directed. |
| 10 | M & L for plain cement concrete 1:2:4 type B-1, using 20 mm graded stone aggregate as in surface channel or drain complete all as specified and directed. |
| 11 | Digging out roots (any dia or girth), filling holes and leveling off ground, stacking of serviceable material and removing of unserviceable material and clearing site complete all as specified and directed. |
| 12 | Supply and fix PVC(SWR)Pipes75 mm bore,single socketed in any length with rubber ring joints, fixed to walls, laid under floors etc.as in waste and rain water pipes complete all as specified & directed. |
| 13 | S&F steel work in tubular trusses including special shaped washer etc complete using ERW or induction butt welded tubes confirming to I.S. 1161-1998 |