Construction Of Beautification 6No. Bijoynagar, Dhar Er Pukur Par Under Ward No. 21- 1 Supplying Eucalyptus-bullah piles at work site,including dressing and making one end pointed.(ii) 125mm diameter 2 Labour for driving Sal-bullah / Eucalyptus bullahpiles by monkey in sorts of soil including hoisting and placing piles in position, protecting the pile head with iron ring and cutting and shaping heads before and after driving and including hire and labour for necessary driving appliances and all tackles.(ii) 125mm diameter. 3 Bailing or pumping out water from foundationtrenches. 4 Reinforcement for reinforced concrete work in all sorts of structures including distribution bars, stirrups, binders etc initial straightening and removal of loose rust (if necessary), cutting to requisite length, hooking and bending to correct shape, placing in proper position and binding with 16 gauge-black annealed wire at every intersection, complete as per drawing and direction. (a) For works in foundation, basement and upto roof of ground floor/upto 4 m. (i) Tor steel/Mild Steel. (i) In Foundation 5 Hire and labour charges for shuttering with centering and necessary staging upto 4 m using approved stout props and thick hard wood planks of approved thickness with required bracing for concrete slabs, beams and columns, lintels curved or straight including fitting, fixing and striking out after completion of works (upto roof of ground floor). 6 Ordinary Cement concrete (mix 1:1.5:3) withgraded stone chips (20 mm nominal size)excluding shuttering and reinforcement ifany, in ground floor as per relevant IS codes(i) Pakur Variety(ii) In Ground Floor 7 Ordinary Cement concrete (mix 1:2:4) with graded stone chips (20mm nominal size) excluding shuttering and reinforcement,if any, in ground floor as per relevant IS codes.a) Pakur Variety 8 Brick work with 1st class bricks in cement mortar (1:6) (a) In foundation and plinth 9 125 mm. thick brick work with 1st class bricks in cement mortar (1:4) in ground floor. 10 Plaster (to wall, floor, ceiling etc.) with sand and cement mortar including rounding off or chamfering corners as directed and raking out joints including throating, nosing and drip course, scaffolding/staging where necessary (Ground floor).[Excluding cost of chipping over concrete surface](i) With 1:6 cement mortar(C) 15 mm thick plaster 11 Neat cement punning about 1.5mm thick in wall,dado,window sill,floor etc.NOTE:Cement 0.152 cu.m per100 sq.m. 12 Supplying ftting and fixing windows and ventilators with or without integrated grills conforming to IS 1038-1975 and manufactured from rolled steel sections conforming to IS 7452-1974 with non-friction projecting type, box type hinges, glazing clips, lugs locking bracket, handle plate etc, including hoisting in position, straitning if required, fixing lugs in cement concrete ( 4:2:1) with stone chips 19 mm down cutting holes and mending good damages to match with existing surface complete in all respect excluding glazing.(iv) M.S. integrated grill as per approved design integrated with steel window or ventilator, joints continuously welded with M.S. flats and bars. 13 Supplying, fitting & fixing 1st quality Ceramic tiles in walls and floors to match with the existing work & 4 nos. of keystones (10mm) fixed with araldite at the back of each tile &finishing the joints with white cement mixed with colouringoxide if required to match the colour of tiles includingroughening of concrete surface, if necessary or by syntheticadhesive & grout materials etc.(B) Wall(i) Coloured decorative 14 Priming one coaton steel or other metalsurfacewithsyntheticoilboundprimerofapproved quality including smootheningsurfaces by sand papering etc. 15 Painting with best quality synthetic enamel paint of approved make and brand including smoothening surface by sand papering etc. including using of approved putty etc. on the surface, if necessary:I) On steel or other metal surface :With super gloss (hi-gloss) -Two coats (with any shade except white) 16 Applying exterior grade acrylic primer of approved quality and brand on plastered or concrete surface old or new surface to receive distemper/ acrylic emulsion paint including scrapping and papering the surface throughly completeas per manufacturess specification and as per direction of EIC 17 Protective and Decorative acrylic exterior emulsion paint of approved quality as per manufacturess specification and as per direction of EICtobe applied over acrulic primer as required. The rate includes cost of materials, labour,scaffolding and incidental charges but excluding the cost of prime 18 Supplying & laying as per IRC-SP:063-2004 paver unit of any shade of approved quality as per relevant IS code, laid inpattern as directed in pavement, footpath, driveway (paver block only), etc including necessary underlay complete in all respect with all labour and material. [Border concrete if necessary to be paid separately].a) 25 mm thick Tiles as per IS: 1237-2012 for footpath,ramp,staircase of public building(over 25 mm thick (Avg) Cement mortar (1:3) & Cement Slurry @ 4.4 kg/Sq.m at back side of Block. Cement for Mortar & Slurry to be supplied by Department). 19 Coal tarring :(b) Two coats. 20 Add 18.00% GST 21 Add 1.00% CESS