Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #50106698

Tender For Repair / Maintenance Of Lt Ug Cable, Capacitor Panel, Lt Panel And Allied Works At Mankhurd Area And Day To Day Maint (B/R Items) To Bldgs At Naval Station Thane Under Ge (Nw) Mankhurd

Issued by Statutory Bodies & Commissions/Committees · mankhurd, Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
31 Jul 2025
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
mankhurd → Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Repair / maintenance Of Lt Ug Cable, Capacitor Panel, Lt Panel And Allied Works At Mankhurd Area And Day To Day Maint (B/R Items) To Bldgs At Naval Station Thane Under Ge (Nw) Mankhurd

BOQ

Name of Work: REPAIR / MAINT OF LT UG CABLE, CAPACITOR PANEL, LT PANEL AND ALLIED WORKS AT MANKHURD AREA AND DAY TO DAY MAINT (B/R ITEMS) TO BLDGS AT NAVAL STATION THANE UNDER GE (NW) MANKHURD.
Sl. No. Item Description
1Petty repairs to wooden joinery works such as Resecuring or easing and adjusting of doors, tower bolts, handles, windows kitchen cabinets in any size, refixing hinges,repair/replacement of wiremesh and glass panes etc by providing glue nails and screws to the satisfaction of user and rectifying other misc minor carpentary works assigned by the Engineer In charge. (Note : Replacement of builders hardware if required will be provided by the department .)Note item No 1 and 2: (a)Rep of contractor will collect details of complint from departmant.The contractor will be alloted complaint on daily basis and sufficient resources will be deployed by him/her for completion of day to day comaplaint within 24 Hrs from the time of reporting.Any delay beyond above mentioned time limit suitable penalties as mentioned in relavant clause of Contract.(b)A detailed log of complaints with completion/ non-completion remarks from users/MES will be maintained by the contractor and same will be updated on daily basis in consulatation with Engr-in-Charge or JE detailed by him.
2(c)The contractor will make suitable arrangment for emergent complaints and will notify auth rep/Engr-in-Charge about extraordinary circumstances for probable non-completion or delay in rectification of complaints beyond state time limit set for disposal of complaint.In case of any dispute the decision of accepting officer will be final and binding in this regard.(d)The quoted rated deems to be inclusive of transportation and other expenses required for the resource deployment at the complaint site around scattered portion under GE(NW) Mankhurd.(e) The contractor will maintain suitable inventories and range of spares required to meet the complaints as same will be reviewed peridically by Engr-in-charge to streamline complaints disposal system.
3All as per No.1 abouve but Petty repairs to plumbing/internal water supply works such as repair to leaking bib taps, pillar taps, mixers stop cocks by tightening and providing spindle,washer repairs to float valves, low leveled cisternto the satisfaction of user as assigned by the Engineer In Charge.
4Taking down cement plaster on brick or concrete surfaces etc, including raking out joints, hacking for key, scrubbing own with water, etc complete all as specified and directed.
5M & L for rendering 15 mm thick in CM 1:6 on brick walls or concrete surfaces finished the surfaces even & smooth incl 1mm thick sagol finish including preparation of old surfaces in patches for repairs at anyplaces inside the bldg complete all as specified and directed.(The work will be in carried out in patches as directed)
6M & L for rendering 20 mm thick in CM 1:4 on brick walls or concrete surfaceslaid in two layers, Ist layer 15mm thick and finishing layer 5mm thick including mixed with integral water proofing compound @ 2% by weight of cement content of finishing layer finished fair and even without using extra cement, including all necessary scaffolding/staging as required including preparation of old surfaces in patches for repairs at any places outside the bldg complete all as specified and directed.(The work will be in carried out in patches as directed)Note : The rate of WPC is deemed to be included in this item. Bidders quoted the rate accordingly.
7M& L preparing new surfaces of wallsapplying two coat of oil bound distemper over one coat of primer complete all as specified & directed
8Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces.
9S&F in repairs Stainless steel Friction hinges for Cupboard etc complete all as specified and as directed by the Engineer in charge.
10S&F stainless steel wire cloth 0.36mm mm nominal dial of wire and average width or aperature 1.40mm for fixing to wooden door/ window shutters in any position with new beads/ steel section as required for securing including dismantling of old jalli and painting to match with existing complete all as specified and as directed.
11Taking down chowkat or frame with shutter (without taking off shutter from the frames) not exceeding 1.5 Sqm each complete as specified and directed.
12Taking down chowkat or frame with shutter (without taking off shutter from the frames), exc 1.50 sqm but not exc 4.0 sqmeach complete as directed
13Taking down shutters of any description,exc 1 Sqm and n.exc 2 sqm eachcomplete all as specified and directed
14Taking down shutters of any description,exc 1 Sqm and n.exc 2 sqm eachand refixing it in the same opening complete all as specified and directed
15M&L for 2nd class Hard wood plain, solid, straight chowkats and frames, wrought, framed, rebated on the solid, rounded or chamfered,put together with glue, pinned at joint complete all as specified and directed.
16S&F,2nd class hardwood 35mm thick Plain, framed,panelled shutters (any number of panels), with panels of timber flat on both sides (feather edged), or of veneered particle board medium density, wood particle board with commercial face veneers: supplied and fitted to chowkats complete all as specified and directed.
17S&Ffor 35 mm thick flush shutters, solid core construction with blockboard core and plywood face panels, commercial type on both sides and fitted to chowkhats complete all as specified and as directed.
18S & F 2nd class hardwood, glazed and skelton shutter, 35mm thick, open rebated and prepared to receive glass, gauze etc,divided into square with plain, chamfered or rounded mitered and rebated sash bars, edges of framing plane, chamfered or rounded, fitted with cut and mitered bead for securing glass, gauze etc, size of member of shutters as specified in SSR Part -I, section 8, class 8.24(a) (Door shutter), supplied and fitted to chowkats all as specified and directed.
19S&F for Solid PVC door frame of size 50mm x 47 mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supplying & fixing in opening as per spcification & drawing etc, complete all as specified and as directed.
20M&L for factory made solid PVC panel type PVC door shutter 30mm thick consisting of frame made out of MS tubes for top and bottom rails MS frame shall be covered with moulded plain colour PVC \"C\" channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail and bottom rails, panelling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles and rails with suitable PVC sheet beading and jointed together with solvent supplying and fixing in the frame at site as per specifications and drawing given under SSR Part II 2010 complete all as specified and directed. Make : SYNTEX/SHALIMAR/RAJSHRI
21S&F for Factory made solid PVC Moulded door shutter , 28 to 30 mm thick (stiles), with 2,4 or 6 raised panel design with 2mm th. Moulded PVC sheet on the front face & 2mmplain coour PVC sheet on back face, supplying & fixing in frame at site as per specification & drawing with wood free EPS etc, complete all as specified and as directed.
22M&L Preparation of new or untreated painted wood andwooden based surfaces of any description not other wise described over 10 centimetre width or girth and applying Two coats of synthetic enamel paintover a coat ofpink primer complete all as specified and as directed.
23M & L for 20 to 25mm machine cut,polished Cuddapahstone slab, in single piece, in window cill, riser of steps, skirting, dado and pillar and similar work,laid over and including backing coat, in CM 1:4, 10 mm thick,jointed with grey cement slurry mixed with pigment to match the shade of the slab including taking down/dismantling old one complete all as specified and as directed
24Taking down existing aluminium joinery of any description (frame/ shutters) with all fittings (but excluding grills) complete all as specified and directed.
25S&F standard aluminum section powder coated in partition / frame and door shutter, sliding windows / ventilators and places otherwise not specified cut to size, jointed with cadmium plated steel screws, including rubber beading or gaskets for fixing glass or wire cloth or Bakelite sheet and all necessary fittings, hinges, screws, plugs, locking arrangements for windows, Nylon ball bearing etc completed all as specified and directed (Aluminum section shall be of make Jindal / Hindalco / Indalco).Note :- Weight of Aluminum sections for frames and shutters shall be only considered for payment.Cost of other consumables required for the item shall be deemed to be included in the quoted rate.However glass panes / Bakelite sheet / wire cloth / mortice lock / locking stay / floor spring / floor door stopper only will be measured and paid separately under respective items as supply only.Fixing by element of these items shall be deemed to be included in quoted rate.
26S&F in repairs aluminium anodised grill DG-104/DG-10210 mm dia of extruded aluminium section of suitable size and frame including fixing with U clip or F section beading complete with all fitting and fixture and drilling required in RCC section in rectangular or arch type balcony opening of the building complete all as specified. incl taking down old existing any description
27Supply only 4.80mm thick glass ordinary quality plainnot exc 0.5 Sqm each pane withincluding wooden/rubber beading or gasket for aluminium sectioncomplete all as specified.
28Supply 12 mm thick prelaminated particle, board, interior grade, prelaminated both sides with decorative choice laminations, fixed with screws to aluminiumframe workcomplete all as specified.
29Supply only stainless steel wire cloth of 0.36 mm nominal dia of wire and average width of aperture 1.40 mm , fixed in aluminium windows complete all as specified and directed.
30S&F bands, straps supports or stay heavy for large gates, hook and pintle hinges clamps, hold fasts, wall tiles, hooks for hanging fans and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
31S&F in repair 100 mm long stainless steel butt hinges fixed with stainless screw
32S&F aluminum anodised barrel tower bolts of extruded section of size 150 mm length
33S&F aluminum anodised barrel tower bolts of extruded section of size 200 mm length
34S&F in repair 150 mm extruded aluminum alloy handles, fabricated type anodised
35S&F in repairaluminum anodised sliding door, bolts with hasp and staple ( bolt type ) and fixing clip of sheet, cast or extruded section and fixing bolts and sliding bolts of extruded section or cast aluminum alloy, length of bolts 250 mm.
36M&L for providing cement concrete type C1, 1:3:6, using 20mm graded stone aggregate as in bed block for hold fast, coping etc including necessary form work complete all as specified and directed.
37Taking down carefully aluminium sliding window shutters from the frames or chowkhat and supply and fixNew locking arrangement in place of old oneand re-fixing the sameshutersin existing position etc, complete all as specified and directed
38Taking down carefully existing aluminium sliding window shutters,(glass/wire mesh) /frame not exc 1.0 Sqm each and re-fixing the shutters in existing position, after repairing complete all as specifiedand directed.
39Taking down carefully existing aluminium sliding window shutters,(glass/wire mesh) /frame exc 1.0 Sqm and not exc 04 Sqm each and re-fixing the shutters in existing position, after repairing complete all as specifiedand directed.
40Taking down carefully existing aluminium sliding window shutters, taking down of existing broken 4 mm thick plain sheet glass from aluminium sliding window shutters including existing rubber gasket complete, supply and fixing5 mm thick plain sheet glass with and including provision of new rubber gasket and re-fixing the shutters in existing position, complete all as specifiedand directed.
41Taking down carefully existing aluminium sliding window shutters, taking down of existing stainless steel wire mesh from aluminium sliding window shutters including existing rubber gasket complete, supply and fixingstainless steel wire mesh of dia 0.36 mm and average width of aperture 1.40 mm with and including provision of \"U\" clip, re-fixing the shutters in existing position, complete all as specifiedand directed.
42S&F in repairs wash hand basin, vitreous china white of size 550x 400mm excluding taps, waste chain and plug and porcelain stopper but including brackets,32mm waste fitting and waste pipe of 32 mm bore, brass, chromium plated for glazed ware wash basin and 15mm dia pillar tapschromium plated fancy type etc complete all as specified and directed.
43S&F in repair low density polyethene pipes (LDPE) 32mm of pressure rating 6 Kg/cm2 fixed to walls or laid in floors etc.
44S&F in repairs 15mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
45S&F in repairs 20mm bore GI tubing, medium grade with and including all fittings and fixed to walls and ceilings or laid in floors, complete all as specified and as directed.
46S&F in repair for gun metal globe or gate valves with iron wheel head , screwed both ends for iron pipe & fixed of size 20mm bore complete all as specified and directed.
47S&F 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls including dismantling of existing pipes of any type any size all complete all as specified and directed.
48All as per item no. 46 above, but 75mm bore
49S&F 110mm bore PVC (SWR) branch piece single (Single Y ) equal or unequal
50All as per item No 51 above but110 mm dia bend
51S &F PVC (SWR) branch piece,single(single Y) 75mm boreequal or unequal
52S &F PVC (SWR) bends, 75mm bore, any radius
53M&L non skid colouredceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.06 Sqm but not exceeding 0.16 Sqm, as in floorsoverscreed bed or bedding layer of morar 15 mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface including dismantling of stone slabs / tiles laid bedded and pointed in any mortar of any description or tickness in floors, aprons etc complete all as specified and as directed.
54M&L for coloured glazed ceramic tiles 300x450x6 to 7mm thick set and jointed in neat cement slurry and pointed with coloured cement as in skirting/dados including 10mm thick rendering in CM 1:4 as in backing coats of tiles finished the surfaces rough to receive tiles etcincluding dismantling of stone slabs / tiles laid bedded and pointed in any mortar of any description or tickness in floors, aprons etc complete all as specified and as directed.
55M&L non skid colouredceremic tiles 7 to 8 mm thick (Square/rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, as in floorsoverscreed bed or bedding layer of morar 15 mm in cement mortar 1:6 set and jointed in neat cement slurry and pointed in white or coloured cement to match the surface incl dismantlling floor herth or wall tiling incl removal of cement mortar bedding (but not backing) removing serveable tiles store & rubbishcomplete all as specified and as directed.
56Demolition of lime concrete or lean concrete from sunken floor including floor tiles, hacking of surfaces after cleaning with wire brush (floor and adjoining walls) and disposing off debris outside MD land, complete all as specified and directed.
57M & L forfilling of lean concrete 1:5:10 type E2 (using 40 mm graded stone aggregates ) in sunken portion, as per requirement, complete all as specified and directed.
58M&L for PCC 1:2:4, type-B, using 20mm graded stone aggregated as in sub base of floors and for any other propose in any location including mixed with WPC @ 2% by weight of cement, complete all as specified and directed.Note: The rate of WPC is deemed to be included in this item.Bidders quoted the rate accordingly.
59M & L for special treatment for sunken portion of WCs/Bath & toilet etc executed in following stages :Stage 1:Providing 15mm thick plaster in CM 1:3 mixed withwater proofing chemical of Dr.Fixit or Shalicrete \"R\" of STP Ltd in the proportion/quantity all as per manufacturer\"s instructions.State 2 : Primer-Mix Tarfelt LM of STP Ltd (diluted with water in ratio 1:1) @ 250 gms/sqm and apply the primer on the plastered surfaces.Stage 3 : Application of 1st coat of Tarfelt LM of STP Ltd (without dilution with water) @ 1Kg/Sqm by brush all as per manufactuer\"s instructions.Stage 4:Laying fyber glass cloth (weight not less than 50gram/ Sqm) over the 1st coat while the coated surface is still sticky.Stage 5:After 6 to 7 hours interval, apply second coat i.e. final coat of Tarfet LM of STP Ltd (without Dilution with water) @ 1kg/ Sqm by brush as per manufacturer\"s instructions.Stage 6:Providing 10mm thick protective plaster in CM 1:3 mixed with STP No. 1 @ 250ml/50 Kg cement all as per manufacturer\"s instructions.Stage 7: Carryout ponding test for 48 hours to ensure water tightness of repaired sunken portion. NOTES :(i)Mode of measurement: Actual area treated (floor and adjoining walls) will be measured and paid .(ii) The above treatment shall be got executed through applicator of manufacturer and necessary authenticated documents on account of above shall also be produced by the contractor.
60S&F in repairs PVC floor trap 75mm dia out let including grating connecting jointing to waste pipe with lead jointing and taking out existing unserviceable traps by hacking out concrete joints and making good of surfaces complete all as specified and as directed .
61S&F in repairs Vitreous China squatting pan “Orissa ” pattern size 580 X 440mm, white, with integral foot rests (excluding flushing cistern and flush pipe )including connecting to trap and to flushing pipe, etc including making good to dismantled portion of floors with P:C:C typeB-0complete all as specified and directed.
62S&F in repairs Vitreous China urinals, half staff urinal, complete including providing and fixing plus, bedding urinal against wall in cement mortar 1:2 securing urinal to plus with and including 60mm long brass screws, pointing around urinal back in cement; fixing with brackets, flush pipe, grating and Union for discharge pipe complete all as specified and directed.
63S&F in repairs Vitreous china wash down water closet pan “Pedestal Pattern” colouredwith wcseat cover coloured closed pattern with flat bottom and mild steel chromium plated or aluminized hingingdevice including pvc flush pipe and joints etc and connection to drain, flushing, pipe, anti-syphonagepipe, and fixing arrangements with fixing bolts etc ,complete all as specified and directed
64M & L for 12mm Plywood, grade BWP, type BB fixed with screws to timber frame work , fixed with screws to timber frame work including beadings etc, complete including dismanlting boarding any description fixed in any position with nails all as specified and as directed.
65M&L for 18mm thick MDFboard for Kitchencabinet/cup board shutter/Partation/Shelves etc in required size at site made out of 18mm thick MDFboard both side decorative lamination PVC sheet complete all required etc.The panels shall be fabricated using adhesive and secure as required.All edges shall be covered with 2mm thick edge bonding taps or 90⁰ edge bent finish as per manufacturers instructions including dismanlting boarding any description fixed in any position with nails all as specified and as directed.
66Supply onlychromium plated shower roses 125mm size with or without swivel joint including fixing to steel pipe or union etc.complete all as specified and directed.
67Supply onlysoap dishcomplete all as specified and directed.
68Supply only Toilet paper holder complete all as specified and directed.
69Supply only Health faucet with 1 mtr tube & hook complete all as specified and directed.
70Supply onlytwo way Bib cock long body with wall flangefitted by 15mm bore complete all as specified and as directed
71Supply only CP corner glass with brass bracket screws etc complete all as specified and directed.
72Supply only CP angle cock 15mm bore fancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
73Supply only CP bib tap 15mm bore fancy type with crutch or butterfly handle, screwedfor iron pipe or for unions and fixed complete all as specified and directed.
74Supply only 15 mm boreStop valves, cast copper alloy screwed pressure, with crutch of butterfly handle, screwed both ends for iron pipe for unions and fixed complete all as specified and directed.
75Supply only waste fitting of 40 mm borebrass, chromium plated for glazed ware for sink coulpling etc complete all as specified and directed..
76Supply onlywaste pipe fittings for WHB/ sink32mm bore fixed to wash hand basin/sinks coupling length pipe 0.90 mtrs each complete all as specified and directed..
77Supply only 15mm size PVC connection with PTMT nuts 450mm length.complete all as specified and directed.
78Supply onlystainless steel grating in round shape 100mm dia complete all as specified and directed.
79Supply only plastic water closet seat cover as per reqd colour with flat bottom and cover and mild steel chromium plated or aluminium hinging deviceetc complete all as specified and directed..
80Supply and fix in repair 10 ltr, PVC, valveless, syphonic action type, flushing cistern, low level/ high level including inlet, ball valve, float and handle including brackets with and including PVC flush pipe 32 mm bore, connecting to WC etc, complete all as specified and directed.
81S&F in repair for CP fancy type concealed stop cock 15mm borefancy type chromium plated.with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
82S&F in repairwall mixer with provision for overhead shower with 115 mm long bend pipe on upper side,connecting legs & wall flanges complete all as specified.
83S&F in repairCP pillar taps15mm bore cast copper alloy, chromium plated fancy type complete all as specified and directed.
84S&F in repair sinks with drainage board made of stainless steel 1mm thick kitchen or laboratory with plugs, washers and wastes including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 460mm boul size 405mm x 354m x 203mm.
85S&F in repair PVC bib taps taps of PTMT any colour high pressure screwed for iron pipe and fixed.(Minimum weight 15mm-110gms
86S&F for towel rail brass chromium plated, 20mm dia, D type, 60cm long between flanges, complete all as specified. Make: Jaquar Cat Part No.ACN 1111SM or equivalent in Make as per Appx `E\" to Particular specification.
87M&L for peg set of six, stainless steel of suitable length, complete all as specified.
88S&F for rotational moulded polyetheylene water storage tanks (cylingrical verticlal with closed top) of 1000 ltr capacity, hoisted and fixedrepair in position including 20 mm dia float valve, dismantling existing water tank.
89S & F in repair Bib tap CP fancy type long body 15 mm bore with will crutch or buttewrfly handle screwed down screwed to iron pipe complete with all fittings all as specified and directed. Make Cera,Parryware, ESSCO.
90S&Fbevellededge mirrorof 600x450selected quality mounted on 6 mm thick AC building boardcommercialplyand fixed to wooden plugswith chromium plated screws ad cup washers complete all as specified and directed.
91S&F for mirror cabinet PTMT of 400mm x 500 mmwith megnetic looking arrangements fixed with and inclduling wooden plugs with chromium plated brass screws.Make: Prayag Cat Part No 554 or equivalent.
92Excavation in trenches not exceeding 1.50 m wide and n.exc 1.5 m in depth for foundation of poles, cable etc, not exc 10 sqm on plan and getting out in soft/loose soil including taking out brick protection etc complete all as specified and directed.
93Returning, filling in, including spreading, leveling, wateringand well ramming in layers not exc 25cm thick complete all as specified and directed.
94Removing excavated materials (soils) not exc. 50m and depositing where directed at a level not exc. 1.5m above the starting point complete all as specified and directed.
95M & L for sand cushioning by spreading in trenches crushed sand by gently by punning down manually as in cable protection all as specified and as directed by Engineer -in-charge.
96Supply and laying un-reinforced precast concrete cable cover class LV, type-I, flat size 250 mm x 150 mm x 40 mm laid in trenches all as specified.
97Supply and Layingor fixing or passing through pipe, XLPE/PVC insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade cross sectional area 95 Sqmm 3.5 core in trenches,along the wallincluding necessary connection and providing cable lugs as required includingdisconnection/taking down of existing unsvcable all as specified.
98-Ditto- all as per item No 96 above here-in-before but 70 Sqmm 3.5 Core -do-
99-Ditto- all as per item No 96 above here-in-before but 50 Sqmm 3.5 Core -do-
100-Ditto- all as per item No 96 above here-in-before but 35 Sqmm 3.5 Core -do-
101-Ditto- all as per item No 96 above here-in-before but 25 Sqmm 3.5 Core -do-
102-Ditto- all as per item No 96 above here-in-before but 16 Sqmm 4 Core -do-
103-Ditto- all as per item No 96 above here-in-before but 10 Sqmm 4 Core -do-
104M&L for cutting existing road/hard standing not exc 45x45 cm in wide & depth getting out excavated material for laying GI tube ;returning filling & well rammaing wateringfinish suraface 10 cm from top using PCC 1:3:6; including removal of surplase soil all as directed by Engr-in-Charge.
105M&L for straight through joint (HEAT SHRINKABLE TYPE KITS) for underground cable including joint kits and labour complete for making joints suitable for LT, XLPE/ PVC sheathed armoured heavy duty cable with aluminium conductor 3.5/4 core up to to 50 Sqmm incl taking down existing terminal joints.
106-Ditto- all as per item No 104 here-in-before but 3.5/4 core 70 Sqmm to 120 Sqmm size -do-
107-Ditto- all as per item No 104 here-in-before but 3.5/4 core 150 Sqmm to 185 Sqmm size -do-
108-Ditto- all as per item No 104 here-in-before but 3.5/4 core 185 Sqmm to 400Sqmm size -do-
109S& F in replacement of GI pipe medium grade 40 mm dia for laying in ground, along the pole in coping, road crossing etc for cabe protectionincluding necessary fittings , clamps for supports, etc all as directed by Engineer in charge.
110Supply and fixPower Capacitors of Rating 25 KVAR 415 Voltin repairs Naturally air cooled Double dielectric heavy duty, MPP type440 Volt 50 HZ Watt Less Power Capacitors wattage not more than 0.5 Watt per KVAR conforming to IS 13340 and 13341 ISI Marked all as specified.
111All as per item No 109 above but Power Capacitors of Rating 20 KVAR 415 Volt
112All as per item No 109 above but Power Capacitors of Rating 15 KVAR 415 Volt
113All as per item No 109 above but Power Capacitors of Rating 10 KVAR 415 Volt
114All as per item No 109 above but Power Capacitors of Rating 7.5 KVAR 415 Volt
115All as per item No 109 above but Power Capacitors of Rating 5 KVAR 415 Volt
116M&L for preparation of old painted surfaces of pre-stressed concrete pole upto 11/9 mtr long by scarping old paint and applying two coats of cement base paint including numbering of pole with black oil paint painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
117M&L for preparation of old painted surfaces of Steel Tubular pole upto 9 mtr long by scarping old paint and applying two coats of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and yellow stripes each 30 Cm apart up to 1.5mtr height including marking of MES No with black paint on the pole all as directed by Engineer in Charge.
118Equipment and labour for servicing of ACB including drawing/taking out from LT Panel, cleaning the Contacts,checking the breaker accessories, replacing the burnt out control wiring, burnt fuse units, old unsversiable spring units for proper function and carrying out ratio testby applying primary injection all for LT ACB 630 Amps to 800 Amps and refixing the breaker in position and testing all as directed by Engineer in Chare at siteNote : The Contractor shall brought all T & P and testing equipments.
119Supply and fix in repairs power factor controller relay 8 Stage RPM 8, 415 volts, 50 cycles suitable for manual / automatic operation with indication for each stage, power factor adjustment setting knob / screw,display. Make : L & T / SCHNIDER/ ABB/ C&S
120S & Fin repair LT 3 Phase Digital ammeter with built in selector switch and connecting including CT & necessary wiring if required complete all as specified.
121S & F in repair Digiital 3 phase 440 Volts VAF PF (Voltage, Current, Frequency & Power Factor) meter with built in selector switch and connecting including CT & necessary wiring if required complete all as directed.
122M & Lfor testing of APFC panel for proper functioning in manual & auto mode, including re-wiring theburnt outwires, replacing the wiring ducts/casing Capping, fuse units and cleaningand testing complete all as specified and directed.
123Supply and Fix in replacement of Contactor Three Pole 415 volts 25 Amps AC 3 Rating,Conforming to Type MNX 25 & Cat No - CS94110 of L & T or Equivalentt from Schnider Electric, ABB including add on Blocks suitable for driving POWER Capacitors, including making addition/Alternation to existing Wiring/circuit system complete all as specified and directed.
124All as per item No 122 above but Contactor Three Pole 415 volts 32 Amps AC 3 Rating Conforming to Type - MNX 32. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
125All as per item No 122 above but Contactor Three Pole 415 volts40Amps AC 3 RatingConforming to Type- MNX - 40. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
126All as per item No 122 above but Contactor Three Pole 415 volts50 Amps AC 3 Rating Conforming to Type-MNX - 50. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
127All as per item No 122 above but Contactor Three Pole 415 volts70 Amps AC 3 Rating Conforming to Type- MNX - 70. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
128All as per item No 122 above but Contactor Three Pole 415 volts110 Amps rating Conforming to Type- MNX - 110. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
129All as per item No 122 above but Contactor Three Pole 415 volts140 Amps AC 3 Rating Conforming to Type- MNX140. Make : L & T or equivalent from Schnider Electric, ABB/ C&S
130S & F in repair MCCB 400 Amps, 36 KA Triple Pole 415 Volts including connecting up complete in existing panel with Lugs/Glands all as specified and directed.
131All as per item No 129 above but MCCB 250 Amps, 25 kA Triple Pole 415 Volts
132All as per item No 129 above but MCCB 200 Amps, 25 kA Triple Pole 415 Volts
133All as per item No 129 above but MCCB 125 Amps, 16 kA Triple Pole 415 Volts
134All as per item No 129 above but MCCB 100 Amps, 16 kA Triple Pole 415 Volts
135All as per item No 129 above but MCCB 63 Amps, 16 kA Four Pole 415 Volts
136All as per item No 129 above but MCCB 40 Amps, 16 kA Four Pole 415 Volts
137Supply and Fix in repairs Change Over FP ON Load with advanced Neutral of current rating 250 Amps 415 Volt IN Sheet Steel Enclosure of 2mm thickness in open construction, panel mounted type with base plate for mounting in panel, including taking down of old Change over and reconnecting the cabes with proper glands.Make: Indo Asian /ABB/Havells/ Standerd
138Supply and fix in repair add on Blocks suitable forPower contactors of range 25 Amps to 140 amps (MNX 25 to MNX 140 including making addition/Alternation to existing Wiring/circuit system all of Make- L&Tor equivalent from Schnider Electric/ABB/ C&S
139Supply and Fix in repairs Push buttons complete of colour red/ green with NO/NC elements, operating on 230 V, 50Hz, AC supply complete all as specified and directed.
140Supply and Fix in repairs Selector Switch 3 Positionsuitable for LT panels, operating on 230 V, 50Hz, AC supply complete all as specified and directed.
141S & F in repairs LED based complete(R Y B ) for mounting on LT panel, operating on 230 V, 50Hz, AC supply complete all as specified and directed.
142S & F in repair Closing coil 415 V/230 V for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed.
143S & Fin repair Shunt Release 415 V/230 for ACB of rating from 630 Amps to 800 Amps complete all as specified and directed.
144M & L for rewiring of old burnt out copper wiring in LT Panels/LT Feeder, replacing of cable Glands, cable lugs, bus bar link, connectors, insulators, door hinges, panel door locks & scrapping of old paints & applying two coats of paint all as specified and directed.
145Dismantling and taking down the existing defective street light fitting/Garden lights/Building security light of any type and any capacity from steel tubular pole, opening the street light fitting, checking the serviceability of spare parts including replacement of defective parts such as electric drivers andconnectors after repairing including refixing on pole including connecting & testing complete all as directed by Engr-in-Charge. [Note:- Electronic drivers and LEDwill be measured and paid separately].
146Supply and fix in repair of Cable junction box IP 66/69 \"weather proof\" (with knockouts for cable entry) box of size 155 x 210 x 92 mm with connector/terminal, Din Rail, GI clamps made out of GI flat of size 25 mm X 3 mm channelincluding providing detachable GI 3 mm thick plate inside looping box as cable gland plate and including cable glands as required at size and making connections all as specified and directed by Engineer –in –Charge. Make - Hensel /National/Sintax
147M&L for locating of faults of LT UG cable XLPE upto 400 sqmm sized by using computerised/ primary current inection method including cutting and removing the faulty portion of the cable and jointing with suitable cable joint and testing after jointing all as required and directed at site.Note: (i) Excavation,earth work,sand cushing, PCC cover etc will be measured and paid seperately.(ii) Cable joint will be measured and paid seperetely.(iii) Additional lenth of cable required at site for jointing will be measured and paid seperately.
148M&L in repairs of Earthing complete with M.S. galvanized earth plate electrode 600 x 600 x 6 mm thick buried directly in ground (earth pit not less than 2.25 M deep below normal GL) with top edge of the plate not less than 2.50 M below normal GL, connected to Galvanized earth strip 32x6mm upto 7.5 mtr with protection pipe by means of bolts, nuts, check nuts & washers of GI or steel incl excavation, PCC (1:3:6) type C-1 chamber with RCC cover (1:2:4) type B0, 40 mm thick reinforced with 6 mm dia bar, 3 Nos. both way, 40mm dia light grade GI protection pipe, funnel with wire mesh,watering pipe of size 20 mm dia med. grade, lugs, main Earthing lead upto 7.5 mtr incl. Charcoal dust, salt etc. all as shown in electrical plate No. 3 of SSR Pt-I 2009 specification.
149S&F in repairs GI strip size 32 x 6 mmall as directed including welding brazing and taking down of old strips as required at site
150M & L spray painting inside, outside complete tothe LT panel boards outdoor type of size not exceeding 2.0 Mtrwidth 2.5 mtr in height and 0.75 mtr in depth with single coat of synthetic enameled paint of superior quality and approved colour after preparation of steel surface.
151Supply and fix in repairs Indoor type vermin and weatherproof totally inclosed cubical type front operated, sufficient ventilation on sides cubicle type fabricted out of 2mm thick CRCA sheet duly treated with seven tank process and painted epoxy powder coated siemens greycolour and with industrial type built in locking arrangement. The Panel indoor type cubical panel board IP 52 free standing floor mounted(CPRI approved manufacturers).The panel to be prewired with PVC insulated copper conductors appropriate current carrying capacity for connecting the incoming and out going MCCBs and MCBs. including disconnecting the LT panel and taking down the unserviceable cables and including MCBs. Energy meters of the panel shall be taking down and kept in safe custody for re-installation of site. Disconnecting the incoming and out going cable connection and dismantling the unserviceable conventional type industrial meter board and removing from site for further disposal and making Lt UG cable connectioncomplete of suitable sizeand comprising of following items:-
152(a)INCOMER (i)MCCB 63 Amps 415V 16 kA 4 pole - 1 No.(b) OUTGOING(i)MCB SPN 40 Amps \"C\" Series - 4 No.(ii)MCB SPN 20 Amps \"C\" Series - 2 No.(iii) Space for fixing of single phase electronic meter - 5 Nos.(c) BUS100 Amps TPN with colour coded heat shrinkable sleeve(d) METERING & INDICATIONi) Digital VAF meter with selector switch & 3 Nos ofCT\"s -1 Setii) Indication lamps for R,Y,B phases -1 Set (Set of Three)e) Internal wiring with suitable size of PVC insulated stranded copper conductor cable duly crimped with copper lugs & ferruled.
153Supply and fix in repairs stainless steel cable glands required for cable entry in Panel of size from 10 sqmm to 50 sqmm etc. complete all as specified and directed.
154-Ditto- all as per item No 151 above here-in-before but for 70 sqmm to 120 sqmm complete all as specified and directed.
155-Ditto- all as per item No 151 above here-in-before but for 150 sqmm to 300 sqmm complete all as specified and directed.
156Supply and fix in repairs alluminium cable lugs of size 16 sqmm to 50 sqmm for cable connection etc complete all as specified and directed.
157Supply only CTC/ CRC solution spray to remove out the moisture and corrosion content from electrical equipement complete all as specified and directed.
158Supply only cotton waste industrial type for cleaning of electrical equipment , Panel board etc complete all as specified and directed.
159M&Lin repairs for 24 Hrs240 V FM1 Quartz type Time switches astronomical type (Having longitude and latitude of Indian cities in memory) timer for controlling street lights contactors complete all as directed by Engr-in - Charge .Make :-Legrand/ L&T/Indo Asian as approved by GE
160Supply and fixing post top lantern LED type 20 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
161Supply and fixing post top lantern LED type 40 watt 230 watt volts AC outdoor type with decorative post top for 360 degree indirect light IP 65 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed in EIC. Make:- HAVELLS/ PHILLIPS/ JAQUAR/ WIPRO.
162Supply and fix electronic meters temper proof LCD display with polycarbonate cover 230 V, 10 - 60Amp suitable for single phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T/Indo Asian
163Supply and fix electronic meters temper proof LCD display with polycarbonate cover 415 V, 10 - 60Amp suitable for three phase, accuracy class-I 50Hz, conforming to IS 13779, IP-54, with parameters to show data, time, current reading, load, PF, voltage and KWH complete all as directed by Engr-in - Charge .Make - L&T/Indo Asian
164M&L for testing of old earthing using calibrated earth tester & submitting result to Engr -in -charge all as directed.Note : (i) Watering of earthing with 2 Buckets (30Ltrs) water mixed with salt (total 20Kg) shall be carried outone day before the testing & the cost of the same shall deemed included in unit rate quoted.
165Supply & fix in repairs GI funnel suitable for GI/ Copper earthing complete all as specified and directed.
166Supply only in repairs Industrial salt suitable for renewal of GI/ Copper earth plate complete all as specified and directed.
167Supply only in repairs Industrial Charcoal suitable for renewal of GI/ Copper earth plate complete all as specified and directed.
168M & L in repairs/ replacement of broken old us PCC earth chamber alongwith PCC cover of size 600 x 600 mm complete all as specified and directed.
169S&F for Multistandarded Copper Conductor PVC insulated, 1100 volts grade cable of 3 Core 1.5 Sqmm size for interconnection of cable looping box to street Light Fitting fixed on the pole including taking down old unsv cable, complete all as specified and directed.
170Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc of size 20mm for Street light Poles complete all as specified and directed.
171A Supply and fixing LED street light fitting 60 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
172S&F in repair of building Security lightfitting 35 Watt made up of pressure die cast alluminium body with mid power LED as lighting sources and PC cover having Top opening separate driver compartment with IP66 protection and impact resistance of IK07including fixing arrangements and taking down old rusted bracket fittings completeall as per directed by Engr- in – charge. Make : Make:- BAJAJ/ PHILLIPS/ JAQUAR/ WIPRO/ HAVELLS.
173S& F in replacement of GI steel tubing medium grade 40 mm dia and length up to 1.5 meter bent to shape of offset angle upto 45degree for fixing of security /street light fittings including MS clamps made of 32mm x5mm flat iron, nuts , bolts, etc all as directed by Engineer in charge
174Supply & Fix 8/9watts LED Bollard Garden light fittings with efficient high outputLED, Pressure die cast powder coated housing with PC diffuser , driver nuts, bolt, washers, base plate, foundation0.3 Meter x 0.3 Meter x 0.3Meter by PCC 1:2:4 type B-1 using 20 mm graded stone aggregates of size including excavation and earthwork, including mounting arrangementupto 2.00 mtr height with medium grade GI tubing of suitable dia 50mm alongwith MS angle bracket/framed covers, clamps complete all as specified and directed. Make - Havells or Equivalent from Bajaj/ Crompton
175Supply & Fix switch piano single poleflush type 5A,240 V one way.
176Supply & Fix Bell push flush type 5 amp, 230 Volts
177Supply & Fix switch socket combination 2 in 1 ,5Amps multipurpose flush type.
178Supply & Fix switch socket combination 2 in 1,3 pin, 5 and 15 Ampsflush type universal.
179Supply & Fix Ceiling rose surface bakelite three terminal, 240 V.
180S & F in repairs Ceiling fan regulator electronic stepped type, AC, 230 Volts, flush type.
181Supply and fix bell ding dong AC 230 V single pole.
182Note : A SUM OF RS 46904.00 TOWARDS SCHEDULE OF CREDIT SHALL BE DEDUCTED TO ARRIVE THE CONTRACT SUM

AI Tender Summary

OUR REF NO 50106698
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE Ref. Documents
LAST DATE 31-07-2025
Authority
Authority Name Military Engineer Services
Work Description Tender For Repair / maintenance Of Lt Ug Cable, Capacitor Panel, Lt Panel And Allied Works At Mankhurd Area And Day To Day Maint (B/R Items) To Bldgs At Naval Station Thane Under Ge (Nw) Mankhurd
Basic Detail
Tender No 8470/E8
Bidding Type Tender
Location
City mankhurd
State Maharashtra
Key Dates
Publish Date 10 Jul 2025
Submission Date 31 Jul 2025
Open Date 02 Aug 2025
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 1 Lakhs
Exemption Not Available
Document List
BOQ_805551.xls
Tendernotice_1.pdf
3d1cd012-de4a-4067-9563-d0d1aca70d35.html
8470General.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 10, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 31, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Aug 02, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_805551.xls

pdf

Tendernotice_1.pdf

html

3d1cd012-de4a-4067-9563-d0d1aca70d35.html

pdf

8470General.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders