Tender For City Beautification Works At Bundi - Rebid - 1 Civil Work 2 Cutting of trees, including cutting of trunks, branches and removal of stumps, roots, stacking of serviceable material with all lifts and up to a lead of 1000 mtrs and earth filling in the depression/pit to required compaction as per oRT&H specification clause 201. (Measurment of girth to be done at height of 1 m above ground level)Girth from 300 mm to 600 mm 3 Clearing and grubbing road land including uprooting rankvegetation, grass, bushes, shrubs, saplings and trees girth up to 300 mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to a lead of 50 metres from road boundary including removal and disposal of top organic soil not exceeding 150 mm in thickness as directed by Engineer.In area of light jungle 4 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding herever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer. 5 Lime Concrete, cement concrete grade M-10 (1:5:10) and below 6 Prestressed /Reinforced cement concrete with separating, cleaning, straightening and cutting of bars 7 Dismantling Brick / Tile work In cement mortar 8 Rubble stone masonry in cement mortar. 9 Dressing of earth work in surface excavation including cutting and filling upto 30cm depth including disposal of excavated earth upto 50m and lift upto 1.5 m. 10 Earth work in excavation in foundation, trenches etc. including dressing of sides and ramming of bottoms, including getting out the excavated material, refilling after laying pipe/ foundation and disposal of surplus excavated material at a lead upto 50m suitable site as per direction of Engineer for following depths, below natural ground / Road top level.In all types soils/ saturated soil such as moorum, sand, sandy silt, clay, black cotton soil, kankar, etc.Depth upto 1.5 m 11 Add extra for over all depth of excavation above 1.5 m and upto 3.0m over item no 4.10.1.1 12 Earth filling with available surplus soil excavated from foundations and taken only from outside of building plinth in layers not exceedin 20cm in depth, consolidating each deposited layer including ramming and watering and consolidation with lead up to 50 m and lift upto 1.5 m. 13 Compensation for earth, taken from private land with all lead and lift (Land to be arranged by private negotiations by the Contractor) [MOST Specification : Clause 301 to 305] 14 Carriage of Materials by mechanical transport including loading, unloading and stacking ::Earth upto 10 Km 15 Supplying Chlorpyriphos/ Lindane emulsifiable concentrate of 20% in sealed containers including delivery as specified. 16 Diluting and injecting Chlorpyriphos/ Lindane E.C. 20% with 1% concentration for POST-CONSTRUCTIONAL anti-termite treatment (excluding the cost of chemical emulsion) :Along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc. 17 Water Quality Analysis– Collecting representative sample and Physical & Chemical testing of Parameter from NABL approved laboratory as per CPHEEO manual: PH, TDS, Electrical Conductivity (EC), Taste & Odour, turbidity, magnesium, Total hardness, total alkalinity, chloride, Dissolved Oxygen (DO), sulphate, nitrate, fluoride, Calcium, Iron, Pesticide, Manganese, Cooper, Aluminium, Residual Chlorine, Zinc, phenolic compound, Arsenic, Cadmium, Chromium, cyanides, lead, selenium, Mercury. 18 Ambient Air Quality Monitoring- For parameters – PM-2.5 & PM-10, SO2, NO2, CO from NABL approved laboratory and submission of report complete in all respect 19 Ambient Noise Quality Monitoring - To Identify sources of noise, Noise due to traffic/transportation of vehicles, Noise due to heavy equipment operations, Duration and variations in noise over time etc. the equivalent noise levels shall be monitored (Lday and Lnight in Leq dBA) from NABL approved laboratory and submission of report complete in all respect. 20 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). 21 Centring and shuttering with plywood or steel sheet upto two storiesor height upto 7.5 metre above plinth level including strutting, propping etc. and removal of form for 22 Foundations, footings, bases of columns, etc. for mass concrete. 23 Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. 24 Columns, Pillars, Piers, Abutments, Posts and Struts 25 Suspended floors, roofs, landings, balconies and access platform 26 Providing and laying in position specified grade of reinforced cement concrete excluding the cost of centring, shuttering, finishing and reinforcement - All work upto plinth level : 1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size). (As per design mix) 27 Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. upto two stories excluding cost of centring, shuttering, finishing and reinforcement1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) (As per design mix) 28 Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement:M-20 Grade Concrete (1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size) -As per design mix) 29 Reinforcement for R.C.C. work at all levels including straightening, cutting, bending, placing in position and binding all completeThermo-Mechanically Treated bars 30 Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : Cement mortar 1:6 (1 cement : 6 coarse sand) 31 Half brick masonry with FPS bricks of class designation 75 in superstructure above plinth level upto two stories. Cement mortar 1:4 (1 cement :4 coarse sand) 32 Random rubble masonry with hard stone in foundation and plinth :Cement mortar 1:6 (1 cement : 6 coarse sand) 33 Extra for random rubble masonry with hard stone in superstructureabove plinth level and upto two stories. 34 Extra for random rubble masonry with hard stone in : Square or rectangular pillars 35 Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete: 36 Steel work welded in built up sections/ framed work including cutting,hoisting, fixing in position and applying a priming coat of approvedsteel primer using structural steel etc. as required. 37 In gratings, frames, guard bar, ladder, railings, brackets, gates andsimilar works. 38 40 mm thick rubbed stone flooring over 20 mm (average) thick base of cement mortar 1:5 (1 cement :5 coarse sand) with joints 3mm thick, side buttered with cement mortar 1:2 (1 cement : 2 stone dust) admixed with pigment to match the shade of stone and pointing with same mortarWhite sand stone 39 Kota stone slab flooring 25mm thick over 20 mm (average) thick base laid over andjointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :Area of each slab 2001 to 5000 sqcm 40 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 0.63 mm thick with zinc coating not less than 275gm/m² 41 Supplying and fixing rolling shutters of approved make, made of required size M.S. laths interlocked together through their entire length and jointed together at the end by end locks mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete including the cost of providing and fixing necessary 27.5cm long wire springs grade No.2 and M.S. top cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with 1.20 mm thick top cover 42 Providing and fixing 1st quality standard white, grey, ivory, fume red brown, light green, light blue and other light shades glazed tiles confirming to IS : 13753 & IS :15622 of size 200mm x 300mm in walls, floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (excluding the cost of cement plaster on walls and pillar). 43 Providing and fixing 1st quality MAT finished ceremic tile size 300x300mm confirming to IS : 13755 and IS : 15622 colour such as white, grey, ivory, fume red brown, light green, light blue and other light shades in floors, steps, pillars etc. laid on a bed of neat cement slurry finished with flush pointing in the white cement mixed with pigment to match the shade of the tile complete (including the cost of cement mortar bed 1:4). 44 Extra for using Marble printed / Granite shade or dark shadetiles instead of white, grey, ivory, fume red brown, light green, light blue and other light shades in glazed tiles and MATfinished tiles. 45 Extra for using size above 200x300mm in glazed tiles and for using 400mm x 400mm MAT finished tiles in place of 300mm x 300mm size. 46 Providing and fixing factory made uPVC door frame made of uPVC profile section having an overall dimension as below (tolerance ± 1mm) with wall thickness 2.0mm ± 0.2mm, corners of the door frame to be mitred and welded of plastic, galvanized brackets and stainless steel screws. The hinge side vertical of the frames reinforced bygalvanized M.S. tube of size 19 X 19mm and 1mm ± 0.1mm wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturers specification and direction of Engineer-in-charge Extruded section Profile size 48x40 mm 47 30 mm thick factory made Polyvinyl Chloride (PVC) door shutter made of styles and rails of a uPVC hollow section of size 60x30 mm and wall thickness 2 mm ± 0.2 mm with inbuilt decorative moulding edging on one side. The styles and rails mitred and joined at the corners by means of M.S. galvanised/ plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 25x20 mm and 1 mm ± 0.1 mm wall thickness. The lock rail made up of H section, a uPVC hollow section of size 100x30 mm and 2 mm ± 0.2 mm wall thickness fixed to the shutter styles by means of plastic/ galvanised M.S. U cleats. The shutter 48 Providing and fixing Granite stone slab mirror polished and machine edge cut in walls, pillars, steps, Shelves, Sills Counters, Floors etc. laid on 12mm (Av.) thick base of cement mortar 1:3 (1 cement : 3 coarse sand) jointing with white cement mortar 1:2 (1white cement : 2 marble dust) with pigment to match the shade of the marble slab including grinding, rubbing and polishing complete.Green / Black Above 3601 Cm2 Slabs 49 Stone work (machine cut edges) for wall lining etc. (veneer work) backing filled with a grout of 12mm thick cement mortar 1:3 (1cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing by means of cramps which shall be paid for separately) : White sand stone - Exposed face machine cut and table rubbed with rough backing. 40 mm thick 50 Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand) including making the necessary chases in stone and holes in walls wherever required. 51 Stone work, plain in copings, cornices, string courses and plinth courses,upto 75 mm thick in Cement mortar 1:6 (1 cement : 6 coarse sand) including pointing with white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade. White sand stone 52 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 20 mm cement plaster of mix :1:6 (1 cement : 6 fine/ coarse sand) 53 Cement plastering including T&P, scaffolding, material and complete labpour, including cost of water, curing, racking of joints etc. with 12 mm cement plaster of mix : . 1:6 (1 cement : 6 fine/ coarse sand) 54 Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete 55 Distempering with 1st quality acrylic washable distemper (ready mixed) of approved manufacturer and of required shade and colour complete. as per manufacturers specification. Two or more coats on new work. 56 Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade New work (Two or more coats applied @ 1.43 ltr/ 10 sqm. over and including base coat of water proofing cement paint applied @ 2.20 kg/ 10 sqm). 57 Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : Two or more coats on new work 58 Random rubble dry stone Kharanja (soling) under floor. 59 Providing laying, spreading and compacting stone aggregates of specific sizes as per Table 400-7 to Water Bound Macadam specification including spreading in uniform thickness; hand packing, rolling with power roller 8-10 tonnes, in stages to proper grade and camber, applying and brooming requisite type of screening (Table 400-8) binding materials to fill up the interstices of coarse aggregates, watering (with water browser) and compacting to required density, making necessary earthen bund to protect edges as per clause 404 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion complete. Crusher broken - Grade-II (63-45mm) 60 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 50mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined.Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. 61 80mm thick 62 S & Laying following size ‘B’ Class G.I. Pipe confirming to IS: 1239P-1 (1990) with accessories for laying earth conductor/ strip/ cable inground/ surface/ recess as required.125 mm dia 63 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work :80 mm dia. nominal bore 64 Constructionofembankmentwithapprovedmaterialobtainedfrom borrowpitwithallliftsandleads,transportingtosite,spreading, gradingtorequiredslopeandcompactingbyvibratoryroller8-10 tonnetomeetrequirementoftable300-2includingcostof compensationforearthtakenfromprivatelandcompleteasper MoRT&H specification clause 305. (Lead taken upto 5 km) 65 Providing and laying Pitching on slopes laid over prepared filter media including boulder apron laid dry in front of toe of embankment complete as per drawing and Technical specifications and as per clause 2504 of MoRT&H Specification. With R.R. Stone/ bolder, weighing not less than 40 kg, thickness not less than 150mm, Specific gravity not less than 2.65. 66 Supplying and fixing machine cut dressed 75 mm Pink sand stone (Bansi Paharpur) dasa/ coping wth ornamental shape having moulding and PAN Shape engraving as per required pattern with engraving depth of 5 mm (average) in single piece of length 90 cm to be laid on cement mortar 1:4 (12 to 20mm thick) including pointing with admixture of pigment matching with the stone shade. 67 Ornamental Work Non SOR Item 68 Providing and fixing Rectangular shaped bansi paharpur stone chatri with carving carving work having size of 3730 mm x 1500 mm base and height is 4490 mm on top of chatri5 no.of stone kalash placed of size 155 mm x 575 mm rectangular stone dome is placed on the top of stone columns having size of 230 x230 mmhaving height of 1800 mm are madeup of bansi paharpur stone.carving work is as per enclosed drawingand detail and instruction of engineer in charge. 69 Providing and Fixing octagonal bansi paharpur stone chatri with carving work having size of 4300 mm x 4300 mm base and height of 7815 mm on top of chatri a stone kalash placed of size 1235 mm x 1500 m stone dome is placed on the top of stone columns having size of 421 x 418 mm having height 1640 mm are made up of bansi paharpur stone carving work is as per enclosed drawing and details and instruction of Engineer in charge 70 Providing and Fixing of 15 mm dia Bronze quartzoid bulb type sprinkler headswith Maximum working pressure 11.6 Kg / Sqcm and suitable for 68 degree centigrade rating standard response (UL Listed) chrome plated complete in all respect of the following type. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR.Concealed type with Tin alloy fusible metal plate for temperature 57 degree Centigrade 71 Providing& fixing of Gear Driven Rain gun sprinkler, grillowith oscillating arm having radius of 41m and flow of 617lpm at an operative pressure of 5 kg/cm.sq, having 11/2 inlet. The body of sprinkler is made of aluminium alloy duty protected in its main parts by brass stainless steel and techno polymers. The sprinkler is equipped with Jet breaker and four different nozzles. 72 Providing and fixing of self closing spring loaded quick coupling 3/4 hydrant ; made of Aluminium alloy doly procted ints main parts by brass stainless steel and techno polymors & having self closing thermoplastic hinged lid, anti rotating device and with requirew no. of 3/4 key for quick coupling hydrant made up of Aluminium alloy ;doly procted. An electro galvanized MS saddle with 3/4 G.I Riser with galvanized nut & bolts and parallel female thread (pressure tight) shall be used to connect the quick coupling hydrant to the pipeline. 73 Supply and fixing different type of steel pre-fabricated garden bench/ jhula/ slides and other children play items made of steel duly painted as per approved design and specifications by engineer in charge made of MS pipe, Flats, rectangular hollow section or other steel sections duly welded and or nut bolted where ever required, rubbing and buffing welded joints to make safe for use of children and painted in approved pattern complete as required. 74 Flooring with white river pebbles of size 25 mm to 75 mm with bidasar green steps laid over cement mortar 1:4 in required pattern including finishing slearing of joints etc complete as per direction of Engineer in charge 75 Stone work (machine cut edges) cladding of local avaliable well dressed slate stone in width from 150 to 300 mm and in length 300 to 450 mm with adjustable stainless steel cramps on rcc wall including required fasteners,stainless steel cramps etc complete as per direction of Engineer in charge 76 Providing & Fixing HDP Dustbins of 40 Liter Capacity in existing CC foundation with MS pipe frames 77 Sanitary Work 78 Construction of Recharge Shaft in filter pit including Earth work Excavation , lifting excavted earth with all lift and 50 m lead and centering & shuttering evenever required. Diameter 900 mm 79 Supply & fixing Pre-cast RCC Rinngs at the mouth of recharge shaft of M20 mix with40 mm thickness Diameter 900 mm 80 Supply & lowering air line of 25mm dia, G.I. pipe B class having perforation 3 to 5mm size all arrow of G.I. pipe in Zig-Zag fashion & making air vent at top including the cost of Tee-Nipples, Elbow, Socket etc. 81 Supply and lowering vent air pipe 63mm dia rigid PVC pipe(IS 4985) mark class II (4kg per cm2 ) with required all necessary fittings including perforation of 3 to 5 mm size all around the pipe at a distance of 180 to 220mm in zig zag fashion and making air vent at top complete as per direction of Engineer incharge. 82 Supply & lying River-gravels of following sizes in recharge shaft, filter pit after screening & washing from kachha shift without deduction of voids 83 Size 9 to 12 mm 84 Size 3 to 5 mm 85 Filling with locally available river sand at all levels including wateringramming consolidating and dressing complete including cost ofsand. 86 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work : 65 mm dia. nominal bore 87 Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore 88 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.External work : 40 mm dia. nominal bore 89 Providing and fixing gun metal gate valve with C.I. wheel ofapproved quality (screwed end) : 90 40 mm nominal bore 91 65 mm nominal bore 92 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete including cutting and making good the walls and floors whereverrequired :White Vitreous china Orissa pattern W.C. pan of size 580x440mmwith integral type foot rests. 93 Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P. flush bend with fittings & C.I. brackets, 40mm flush bend, overflow arrangement with specials of standard make and mosquito proof coupling of approved municipal design complete including painting of fittings and brackets, cutting andmaking good the walls and floors wherever required :W.C. pan with ISI marked white solid plastic seat and lid 94 Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brassincluding painting of fittings and cutting and making good the walls and floors wherever required :Single half stall urinal with 5 litre P.V.C. automatic flushing cistern 95 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps,32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps. 96 Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete 97 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:893115 mm nominal bore 98 Providing and placing on terrace (at all floor levels) polyethylene water storage tank ISI : 12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank 99 Providing and fixing G.I. pipes complete with G.I. fittings and clamps, including cutting and making good the walls etc.Concealed pipe including painting with anti corrosive bitumastic paint, cutting chases and making good the wall.15 mm dia nominal bore 100 Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. 75 mm dia 101 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 20 mm dia. nominal bore 102 Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work : 32 mm dia. nominal bore 103 Providing, lowering, laying in trenches, aligning, fixing in position and jointing Ductile Iron (DI) ISI marked K-7 grade S&S pipes as per IS:8329-2000 (amended upto date), with internal cement mortar lining for potable water with rubber ring (EPDM/SBR) joints as per IS: 5382-1985 (excluding special accessories) complete including all material, labour, hydraulic testing and commissioning as per Technical Specifications and as per direction of Engineer. Note : E/w to be measured and paid separately. 100 mm 104 Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS 13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required : Kitchen sink with drain board 510x1040 mm bowl depth 178mm. 105 Providing and fixing PTMT pillar cock of approved quality and colour15mm nominal bore, 107mm long. Weighing not less than 110 gms. 106 Constructing masonry Chamber 60x60x75 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for fire hydrants, with C.I. surface box 350x350 mm top and 165 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand:10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks 107 Constructing masonry Chamber 120x120x100 cm, inside with 75 class designation brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm. top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement :2 coarse sand : 4 graded stone aggregate 20 mm nominal size) necessary excavation foundation concrete 1:5:10 (1 cement : 5 fine sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick finished with a floating coat of neat cement complete as per standard design : With F.P.S. bricks 108 Electrical Work 109 Wiring of light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)inrecessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & itsISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot Dipped Galvanized Modular Box with earth terminal, 10A Modular switch, Modular face plate with grid plate, 3 pin ceiling rose / Holder /3 way connector, screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure A attached with this BSR 110 Short point (up to 3 mtr.) 111 Medium point (up to 6 mtr.) 112 Long point(up to 10 mtr.) 113 Wiring of twin control light point with 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade (IS:694)in recessed ISI markedMMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988) accessories, round tiles, 2 Nos Hot Dipped Galvanized M.S Modularbox of 1.2 mm thickwith earth terminal, 2 Nos 10 A two way Modular switch, 3 pin ceiling rose / holder / 3 way connector ,Modular face plate with grid plate,screws,making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter-53, 54 & 56 for additional technical parameters of product / work refer Annexure A attached with this BSR 114 Short point (up to 3 mtr.) 115 Medium point (up to 6 mtr.) 116 Long point(up to 10 mtr.) 117 Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal sizeFR PVC insulated unsheathed flexible copper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathed flexible copper earth conductor 1.1 kV grade(IS:694) inrecessed ISI marked MMS ( IS:9537 P - III ) PVC conduit & its ISI marked (IS:3419-1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc. as required.For specification of copperConductor,Phenolic Laminated sheets & Electrical/ Wiring accessories refer Chapter-53, 54 & 56. For additional technical parameters of product / work refer Annexure A attached with this BSR 118 On board 119 Short point (up to 3 mtr.) 120 Medium point (up to 6 mtr.) 121 Long point(up to 10 mtr..) 122 Sub Head - II - Drawing of Wires and Submains 123 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 124 20 mm 125 25 mm 126 40 mm 127 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 128 1 x 1.5 sq.mm 129 3x 1.5 sq.mm 130 1 x 2.5 sq.mm 131 2 x 2.5 sq. mm. + 1x1.5sqmm 132 2 x 4.0 sq. mm. + 1 x 2.5 sq. mm. 133 2 x 6.0 sq. mm. + 1 x 2.5 sq. mm. 134 4 x 6.0 sq.mm 135 Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of load andsite requirement) 4 KV impulse withstand voltage, ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947-2, low watt losses, trip free mechanisum , energy limiting ofclass 3 as per IEC,minimum phase termination capacity of 35sq.mm. , conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000 upto 20 A rating and 10,000 upto 63 A, 5000 for 80 A & above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 136 Single pole MCB (With B/C curve tripping Characteristics) 137 6 A to 32 A rating 138 Triple pole MCB(With B/C curve trippingCharacteristics) 139 6 A to 32 A rating 140 50/63 A rating 141 Four pole MCB (With B/C curve tripping Characteristics) 142 6 A to 32 A rating 143 50/63 A rating 144 Providing & Fixing of 240/415 V isolatorISI marked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KV impulse withstand voltage,true contact indication,Red colour dolly / lever shall have single mould covering over all poles for operation , two position din rail mounting,minimum phase termination capacity of 35sq.mm.IP 20 contact protection and fitted in existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 145 Double pole isolator 146 30 A / 40 A rating 147 Four pole Isolator 148 63 A rating 149 P&F metal clad / Plastic industrial plug top & socket unit with pin and sleeve type contact on porcelain/ bakelite base in Recessed/surface mounting heavy duty Enclosure made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted (without MCB) including making connections, testing etc.as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 150 20 amp, 3 pin + scrapping Earth, 4 Module 151 Providing & Fixing of Recessed/surface mounting heavy duty horizontal type Double Door ( Metal / Glazed )Distribution board with Metal end box made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3, powder painted complete with reversible door (for double door DB only )100 amp. insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 152 Glazed door (single phase) IK-09 and IP-43 with Metal end box 153 12 Way (12+2) 154 Glazed door (Three phase) IK-09 and IP-43 with Metal end box 155 12 Way 156 Providing & Fixing of Recessed/surface mounting heavy duty Vertical TPN Distribution board with Metal end box withprovision of incomer suitable for MCB / RCCB and SP / TP MCB as outgoing ,made out from Galvanized steel / CRCA sheet not less then 1.2 mm thick conforming to IS-8623-1 & 3 / IEC 61439- 1 & 3. powder painted with reversible door (for double door DB only ) complete with insulated 100 A rating copper bus bar, neutral bars with shrouds, earth bar , color coded interconnecting wire set of suitable rating and din bar,masking sheet, making internal DB terminations with copper lugs, ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge.For additional technical parameters of product / work refer Annexure A attached with this BSR 157 Double door IK-09 & IP-43 with Metal end box 158 8 Way(8+24) 159 12 Way(8+36) 160 Providing & Fixing of modular type switch/ bell push duly ISI marked (IS :3854) with CM/L no. printed and made out of unbreakable and fire retardant vergin UV Stabilized Polycarbonatewith brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,minimum width ofswitch toggle( PUSH PART ) should not less then 20mm,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 161 10 A one way switch 162 10 A two way switch 163 16 A one way switch With LedIndicator 164 Providing & Fixing of modular type lockable feature socket dulymade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 165 6 A3/5 pin shuttered socket 166 6/16 Ashuttered socket 167 Providing & Fixing of following modular accessories as per PWD specification for electrical Works,made out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating , includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 168 RJ-11 telephone jack Double line 169 RJ-45, Cat 6 computer jack with shutter 170 T.V. coaxial socket 171 Providing & Fixing of modular type 120 W Step Fan regulator duly ISI marked (IS 11037:1984 ) with CM/L no. printedmade out of unbreakable and fire retardant vergin poly carbonate with brass terminals and captive screws & silver alloy contact tipwith IP-20 rating ,includingall as per pre approved by Engineer in charge,making connections, testing etc. as required.For additional technical parameters of product / work refer Annexure A attached with this BSR 172 5 step fan regulator 2 Module 360 dgree rotating 173 Providing & Fixing ofWiring Accessories OEM fabricated following size GI box of 1.2 mm thick with earthing terminal and adjustable floating clamp in recess/ surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 174 3 Module 175 4/5 Module 176 10 / 12 module 177 16/18 module 178 Providing & Fixing of Wiring Accessories OEM fabricated following size virgin materialUPVCmodular boxes on surface suitable for modular accessories as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 179 1-2-3 Module 180 4-5 Module 181 6-8 Module 182 10-12 Module 183 16/18 Module 184 Making of hole in wall (brick/stone) of required and placing NP-2 RCC pipe ring of required size for housing exhaust fan and making good the same, with cement plaster required of following size. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 185 Up to 457 mm size 186 Providing & Fixing ofBEEStar rated copper wounded double ball bearing capacitor start, aluminium body & Metallicblade ceilingfanConforming to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable ; & Carry BIS licensing (i.e. ISI marking) with down rod up to 80 cm with secondary support safety cable ( steel rope) , cotter pin with 3 x 1.5 sq.mm pvc insulated flexible copper conductor making connection testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 187 1200 mm Sweep BEE 3 Star rated (service value >=5.0 to< 5.5 ) 188 Providing & Fixing of Heavy duty capacitor start, copper woundDouble ball bearing900/1400 RPM single phaseExhaustfan conforming to IS:2312 ISI marked in existing opening including making connections testing etc. as required. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 189 300 mm sweep(900/1400 RPM) 190 SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalisedcubical panel as specifications andOther parameters requiredas per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shallbe 2.0 mm,cable alley compartments having concealed hinged type doors with key type lock with / withoutdetachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting,pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel.The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c)Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar(>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only.All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar/ Flexible wire for Interconnection between Main busbar and Switchgearis to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cableshall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMCchannel size 100 x 50 x 5 mm( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by applying a voltage of 2.5KV for one minute) shall be measured between phases, between phase and neutral and between phase and earth. both before and after high voltage power frequency test. The insulation resistance shall not be less than three megaohm. CT Secondary current injection test shall also be carried out.(h) only outer surface area on all sides shall be measured & panel to be fabricated only from CPRI approved fabricator only (CPRI Test certificates to be submitted)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 191 Supplying and fixing of Aluminium (IEC 60105 ISO 209-1,2) / Copper (IEC 60028) bus bar by means of SMC / DMC type insulatorwith standard short circuit withstand capacity, high tensile nuts and bolts spring washers in existing panel including bending , cutting in required shape and size and colour coding with heat shrinkable PVC sleeves. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 192 Electrolytic grade Aluminium bus bar 6010 grade 193 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 194 Single Phase Voltmeter 195 Providing & Fixing of IS: 13875 & IEC :61326 confirming LED Digital type(up to 500) V range Volt meter / Direct- Ammeter /CT oertated ammeter/ Frequency meter / KWH meter / Multi Function Meter / Power analyzer of class 1 accuracyas per IS : 1248 of size 96mm x 96 mm including making connection by PVC insulated copper conductor with PVC sleeves / channel etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 196 Single Phase Ammeter 197 Providing & Fixing of BIS approvedCurrent Transformeras per PWD specification for electrical Works ,ISI marked as perIS 2705-1992/ conforming to IEC 60044-1, with secondary terminalof CT shall be brought out suitable to a terminal block which shall be easier accessible for testing and terminal connection , with all necessary support in existing panel including connection etc. as requiredCurrent transformer Ring Type Tape Wound/Resin Cast Wound as per IS 16227 with, Accuracy Cl, CT ratio and burden as specified. ISF<=5, Cu cross section of secondary wire 1.5sqmm (minimum), including all necessary support in existing panel including connection etc. as required . All as per pre approved by Engineer in charge.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 198 C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA/C T Class 1, Ratio 1600/5 to 3000/5, Burden 15 VA 199 Providing & Fixing of selector switch of 10 A for voltmeterusing high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour including making connection etc.as required . All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR57.5.1 : Voltage Between Phases with OFF ( 4 Position ) 200 Providing & Fixing of CT linked selector switch of 10 AforAmpere meter (4 position )using high grade engineering materialto international standards with cam assemblyinsulation of glass filled polyamide with high tracking index. For reliable and stable electrical and mechanical endurance double butt contacts with silver bi-metal on copper should provided . contact assembly is of operating temp range -25 degree C to 55 degree C, frequency upto 10 KHz. switch life under std. op. conditions shall be mechanically minimum 50000 operations @300 cycles/ hour and electrically 10,000 operations at 100% rated duty for 100 cycles/ hour , including making connection etc.as required .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 201 Providing & Fixing of110/220 V, unibody LED Indicatinglamp IEC 60947with integral circuit, IP 65 above panel &IP 20 terminal block, Approx. body dia for panel not less then 20 mm, length min. 50mm, front LED cover dia min.29 mm, contact material phospher bronze for Led, PCB contacts shall be ofbrass (tin plated), impulsedielectric tested for 2.5 KV, Rated insulation resistance shall be 100 M ohm at 500VDCincluding connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 202 Red/yellow/Green colour 203 Blue / white Colour 204 SITC of3 /4pole current limiting Moulded case circuit breaker (MCCB) made of flame retardent & heat resistant materialhaving following current rating, short circuitbreaking capacityat 440/415 V, 50 Hz; O/L & S/C settings , conforming to IS/IEC 60947 P -2 :2003 with frontface and centralised adjustable, trip free mechanisum, true contact position indicator,line load interchangeability,designed for both horizontal & vertical mounting without any adverse effect on electrical performance, suitable for operation upto 55 degree and without derating upto 40 degree,pollution degree 3, having positive isolation capability, push(test) to trip, trip time less then 10 ms under s/c condition, Breaking capacity Ics = 100% ICU. U imp =8 KV, rated insulation voltage690 V.provision for UVR , shunt trip , earth fault trip, door interlock, pad lock & rotary handle , including making connectionsetc. as required.OEM shall have submitNABL / CPRI / ERDA accrediated lab type test certificate before execution All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 205 4 pole MCCB With Thermal Magnetic release 206 up to 100 Amp , 25 kA, adjustable O/L & adjustable S/C setting, 207 400 Amp , 35 kA, adjustable O/L & adjustable S/C setting, 208 Supply and fixing of following accessories for Air circuit breaker (ACB)compatible with MAin ACB OEM as per PWD specification for electrical Works, conforming to IS/IEC 60947 P - 2 :2003 including making connection etc complete in all respect. OEM shall have submitNABL / CPRI / ERDA accrediatedlab type test certificate before execution.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 209 Shunt Trip Release 210 Under voltage Release 211 Earth Fault Module 212 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 213 10.0 Sq. mm x 4 core 214 50.0 Sq. mm 215 3.5 core 216 95.0 Sq. mm 217 3.5 core 218 300.0 Sq. mm 219 3.5 core 220 16.0 Sq. mm 221 4 core 222 6.0 Sq. mm 223 4 core 224 Providing & Laying XLPE insulated three core ArmouredAluminiumcable for working voltage 11 K.V.(E) confirming IS :7098 P - 2withH4- Grade electrolyticaluminium conductor confirming to IS: 8130 class-2 of purity >99.6 %, Insulation Screening: Extruded Semiconducting Compound followed by helically wrapped Copper Tape, round / flat strip armouring of cables , Inner / outer sheath PVC type ST-2 confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810 All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 225 3 core 120.0 Sq.mm 226 Providing & making heat shrinkable type indoor/outdoor/straight through terminations/ joint kitsuitable for11 KV / 33 KV (Earthed) cable with required components, prepration of cable ends. Type test report should be as per IS13573:2011 which covered all sequence for table 2 for termination kit and table 3 for streightthrough joint inclusive thermal & dynamic short circuit test, humidity test, soil fog test. Crosslinking shall be done out side factory with E- beam/ peroxide technology. Extrusion process shall be in house OEM within same vicinity. includingtesting etc. as required of following sizes. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR 62.7.2 11 KV End Termination Kit Outdoor type 227 3 core 120/150/185 Sq.mm 228 Supplying and making one end termination with Nickel plated heavy duty brass single compression gland (as per IS 12943-1990)) SIBG type consisting of Check Nut, Gland Body, Metal Washer(3 Nos.), Outer Seal Rubber Ring,Compression Nut,heavy duty aluminium lugs (as per IS 8309 -1993) duly crimped with crimping tool, PVC tape as perIS 8337-1976offollowing size ofPVC insulated & PVC sheathed/ XLPE aluminium conductor cable of 1100 volt grade as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 229 3.5 x 95.0 sq.mm 230 4 x 6.0 sq.mm 231 4 x 10.0 sq.mm 232 4 x 16.0 sq.mm 233 3.5 x 50.0 sq.mm 234 3.5 x 300.0 sq.mm 235 Supply, Fabricating & installing following sizes of perforated Powder coated MS cable tray with perforation not more then 17.5% in convenient section including horizontal and vertical bends, reducers tees,cross members and other accessories as required and duly suspended from the ceiling with GI suspenders including GI bolts & nuts , fastners, supports etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 236 300mm x 50mm x 1.6mm 237 150mm x 50mm x 1.6mm 238 P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class750 N,Externally corrugated and having smooth surface insidewith HDPE Coupler, Elbow, Teeat required Depth below the ground for laying cable of followingNominal Outer dia.MFR Test reportfrom NABL accrediated is to be submitted.(Excavation of Earth& Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 239 120 mm 240 Plate Earthing as per IS:3043 withcopper Earth plate of purity >95% of size 600mm x 600mm x 3.0mm by embodying3 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 241 Supply & Laying following size earth stripin horizontal or vertical run in surface by means of Earth strip DMC Insulatorincluding riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 242 25mm x 5mm copper strip 243 25mm x 6mm G.I. ( Hot Dipped) Strip 244 Supply & Laying following size earth wire in horizontal or vertical run in ground/surface/recess including riveting, soldering, saddles,making connection with GI/Cu purity purity >95%thimble etc. as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 245 8 SWG G.I. ( Hot Dipped) Wire 246 Providing & Fixing of IK07 IP-66 protected high power LED flood light system with Pressure diecast aluminium housing LM6/ ADC12 material , toughened glass diffuser with suitable lenses on LED to achieve various beam angles, 240 volt, 50Hz, of high power LED lamps . Integrated driver must be potted & has a unique BIS number shall be high efficiency having efficiency more than 85 % and in compliance to BIS certified and T.C. certificate. The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used . LED driver Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety . Input Frequency 50Hz±3%, Power Factor >0.95 ,driver Efficiency >85% , THD(I) <10% , driver current <1000mA shown in LM79 report. driver should be Phase to phase protection of 440 V for 4 Hrs. Electrical Connector Must be provided, Surge Protection Min >=4KV internal and 10KV external, System life of 30000 Burning hours with 70% of Initial Lumens maintained, color Rendering Index >70 and CCT 5700K ±355K. Driver current <1000mA shown in LM79 report. Fixture shall be IS 10322 Compliant. All as per pre approved by Engineer in charge. 247 High Power LED Flood Light 30W 248 Providing & Fixing of IP 20 boxmade outfrom 1.2mm thick CRCA sheet steel with depth of minimun 30 mm and finished with powder coating andsuitable for mounting LED tubeincludingside covers, holders , internal wiring to illuminate the single sided connection LED tube. ( Without tube).All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 249 Suitable for 4 LED Tube shape fixture for double rod 250 Providing & Fixing of 400 mm SweepBLDC technology Oscillating type Wall mounting / Pedestal typefans with Three speed, ON andOFF position, Double Wall bearing withfront and back 120 or moreribs guard; Three no.blades, noise level should be <= 75 dB,including fixing with anchor bolts, making connection testing etc. as required. ( With Remote ) All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 251 Wall mounting type with Service value 2.0 CMM /W, Min. Air Delivery 71 CMM 252 Supply & Installation of IP-20 & IK-08 , UL ListedWall mounted Double Section Communication enclosure (Rack) made from powder coated (60 to 80 Micron) CRCA sheet, front sturdy sheet steel frame folded from one piece and welded with minimum 5mm toughened glass door,Vertical Mounting Rail 1.6 MM with UMarking , with All round protective channel on the door aperture, lock integrated on front door, top and bottom cover with cable entry provision with gland plates, integrated side walls, 2 pair of 19 angles with wall mounting provision on wall. Accessories like: 1 No of 19 1U Horizontal Cable manager, 1 No of 90 cfm 230V AC Fan with 1 mts long cable, mounting hardware , 1 No of 19 1U, mountable socket strips with 5 nos of 5A universal sockets with 2 mts long power chord for supplying power to switches, fans etc along with earth continuity kit, indicator, moulded power supply cable. fixing on wall with Suitable Anchor fastneretc as required.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 253 12 U Rackwith Width 600 mm &Depth 400 mm + 100 mm 254 Providing & Fixing of ISO certified company made on load change over switch, front handle operated, four pole 415 V as per PWD specificationfor electrical Works conforming to IS/lEC 60947-3 : 1999 including connections , testing etc. as required .in the following rating.Appropriate type test certificate / OEM test report shall be submitted .All as per pre approved by Engineer in charge. For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 255 400 A 256 SITC of star ratedAluminium wound distribution Transformerof following rating 11/0.433KV Delta-Star Connected, Vector Group Dyn 11,ONAN Cooled & as per BEE star - 1 & BIS approved as per IS 2026- 1977 & lossesas defined as per 2014 (Fourth Revision) Level-1 . including standardaccessories like conservator, silica gel breather, radiator, fins, HT cable box & LT cable boxes, temperature rise in winding/oil 35-40 degree C upto 200 KVA & 40-45 degree C for above 200 KVA, ISI marked drain valve, Dial type Temperature gauge, first filling of transformer oil as per IS :335-1953, Epoxy based paint,including carrying of pre-commission Testing & Charging of complete in all respect .The Transformer shall be subjected to routine factory tests (as per IS:2026 and IS:1180) including testing from CTLof discombefore charging of transformer & complete installaion must be certified from Electrical Inspectorate office as per Indian Electricity rule, (CTL testing charges and Electrical Inspection charges shall be reimbursed by the department to the contractor). All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 257 250 KVA with Off -LTC (+5% to - 10% @ 2.5%) 258 Supply & Installation of D.P. Structure With AIR BREAK SWITCH having following specifications A, B, C, D, E. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 259 A) Double pole structure on 2 no ISMB ( I beam ) of size 150 x 75 mm,10 mtr length using 7 no MS channel each of size 100 mm x 50 mm x 2500 mm complete in all respect with nuts, springs washers, clamps as required. 260 B) Off load type gang operated 3-pole vertical flute type switch suitable for 11KV ; 400A ,3-ø, central post rotating double break isolator complete with MS hardware , copper moving & fixed contact ,assembly of 9 nos pin insulator ,GI pipe of suitable length for operation. 261 C) 3nos Vertical / Horizontal mounted 11kv horn gap fuse set /drop out 11kv barrel fuses mounted on 6no pin insulators 262 D) 3 piece non linear resistor type. lighting arrestor of approved make suitable for 3 wire, 11kv Overheadline with rated voltage of 9kv rms & nominal discharge current rating of 5 ka & complete with galvanized clamping arrangement GI bolts, nuts, washer etc as required. 263 E) 3 no 11kv ACSR conductors mounted on pin type insularors as required. 6.GENERAL:The go shall be operated by hand operated liver properly earthed with provision for locking mounted at 3’ 264 Dismantling and re - fixing of piller box made of 2mm CRCA MS sheet of 415 volts 3 phase 4 wire triple pole and neutral type, complete in all respect as required. Including knife switch, HRC fuses with copper one piece U contacts base, brass studs and nuts, copper busbar for main and interconnection, MS angle frame of 50 x 50 x 6 mm grouted with C.C. of M-10 grade to achieve the height of 1.5 feet above the road level suitable for four outgoing.(400Amp capacity) 265 Providing, installation, testing and commissioning of Centrifugal Monoblock pump set conforming to IS 9079 , 2 pole motor operating at synchronised speed of 3000 RPM with requisite MOC impeller, priming funnel, cock, suitable flanges at suction and delivery side. Pump shall have common shaft for pump and motor. Motor shall be suitable for working on 415 V ± 10%, 3 Ph, 50 Hz A.C. Supply. Motor shall be TEFC type and Pump set shall be suitable for working at various discharge and head requirements as per scope of work. Pump shall be erected onC.C. foundation / cross channels / RSJ frame block with suitable foundation bolts grouted in C.C. foundation block etc. complete in all respect as perspecification, scope of work and direction of Engineer in Charge of following power rating, suitable for prescribed duty conditions mentioned in TD.19.99.1 Centrifugal Monoblock Pump set (Single Stage) 266 2.2 KW (3.0 HP) 267 Supply and erection ofGalvanized Iron pole with galvanizing done in single dipping (Average coating thickness Minimum 65 Microns) continuously tapered poles having Octagonal / Circular cross-sections designed to withstand the maximum wind speed as per IS 875, The pole shaft shall be made from sheet steel (HT Steel Conforming to grade S355JO) and confirming to BSEN 10025 and shall be continuously tapered with single longitudinal welding. There shall not be any circumferential welding. The welding of pole shaft shall be done by Submerged Arc Welding (SAW) process. pole shafts shall be provided with the rigid flange plate of suitable thickness (Fe 410 conforming to IS 226 / IS 2062) with provision for fixing 4 no. foundation bolts, This base plate shall be fillet welded to the pole shaft at two locations i.e. from inside and outside.The octagonal Poles shall have lockable door of approximate 500 mm length at the elevation of 500 mm from the Base plate with bakelite sheet having 6A SP MCB and 16 sqmm stud type connector ( 4 nos) inside the pole at door opening for cable connection of following length and dimension as per table P-01 with base plate and foundation bolt on the Existing cement concrete foundation.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 268 7 Mtr. 269 Providing & Fixing of IK08, IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminummaterial with heat dissipation fins on housing with UV stabilized PC (UV stablization report submitted for UV cover ) /Toughened Glass coverand secondary lens on each LED & should be SMD type of 3 to 5 watt each . The System efficacy >=125 lm/ wt and potted driver& has a unique BIS R number withInput Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety , Power Factor >0.95 driverEfficiency >85%,THD(I) <10%Humidity 10% to 90% RH Working Temp -5C to 45C .driver current <750mA. The luminaireshall be BIS certified and Trade mark certified. Life ExpectancyEqual or more than 50000 burning hrs with Minimum 70% lumen maintened , CRI >70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external inside driver compartment. driver should be Phase to phase protection of 440 V for 4 Hrs.Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM shall be submitted. All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 270 LED Street Light fixture with Minimum lumen output 2450 lm 271 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 272 Two pole 100/300mA sensitivity 273 63 A rating 274 Providing & Fixing of ISO certified company made IK10IP65 protected Top/Bottom mounted LED Post top Light system. Fixture made of powder coated die cast alluminium housing with UV stabalized PC diffuser. The System level Luminous efficacy ≥90 Lumen/W. SMD LEDs is to be used, System CRI>70, CCT: 3000/4000/6500 K. The integral electronic driver must be potted & has a unique BIS R number must be potted & has a unique BIS R number constant current and Internal/external surge protection device of min. 4KV(L-N)and efficiency > 85%, PF>0.9, THD<20% and input Voltage range of 90-270V AC at 50Hz. System life of 30000 Burning hours with 70% of Initial Lumens maintainedLight output in Cool white or Warm White Colour as per engineers choice. driver current <1000mA shown in LM79 report.Fixture must be in compliance with BIS Standards and T.C . Certificate complete in all respect.OEM Must have its own in house NABL lab setup for all testing facilities forLED fixtures.(LM79/LM80) Certificate/ report with liable warranty of product/accessories from OEM. All as per pre approved by Engineer in charge. 275 30 W LED Post Top Fixture 276 S& F of all in one solar LED street light fixture with Integrated high efficient Monocrystalline panel with Lithium (LiFePO4) Ferro Phosphate battery with BIS approved make .luminaire should be secondary optic lenses for better distribution with delivered efficacy of > 100 Lumen perwatt.Bidder shall have in house R&D Laboratory which is recognised by ministry of Science & Technology department, Govt. OfIndia/ NABL.Bidder shall have inhouse pole & luminaire manufacturing facility. Luminaire can be supplied with Hybrid switch along with indicator to understand the source of power( either from solar or AC supply).shall have certificate tested fromMNRE approvedLab. Guarantee for total system is two years .Note: All the above should be integrated and should be 1 system. make: Bajaj/ Philips / Crompton. 277 Compact Solar LED Street Light - 35W(MONO) 18V/ 12.8V9Ah/12W 278 Provide and fixing of LED POST TOP fixture made form Die cast aluminum graphite grey powder coated finished housing. Polycarbonate opal diffuser. Low power Warm White (WW) LEDs connected in series and parallel combination with better Heat dissipation arrangement. Highly efficient constant current electronic driver having operating voltage range from 140- 280 Volt AC;provided with high voltage, open and short circuit protection.Suitable for 60mm OD pipe entry with fixing bolts. Degree of protection IP65 LED Make – Nichia/Philips/Osram/Cree or Equivalent LED color temperature range form 3000-5700°K ±300°K. Voltage surge protection 5KV. the luminaire should bear 5 KV surge protection,PF >=0.9(HPF) and total harmonic distortion of THD(I) <10% voltage range of 140-280V. Manufacturer to provide certificate of LM 80 LM 79 form source manufacturer and shouldhave in house adequate testing facilities ( approved by Govt. of India ministry of science and technology/NABL) . Approved Luminaire Make: Philips, Bajaj, Keselec. 279 LED POST TOP 65W 280 Façade Lighting , Wall Waser,Fixtures 281 Supply, Installation, Testing and Commissioning of Spike Light with10 Degree Beam Deflection and 3000 K CCT.6 Watt 282 Supply, Installation, Testing and Commissioning of Spike Light with10 Degree Beam Deflection and 3000 K CCT.12 Watt 283 Supply, Installation, Testing and Commissioning of IP44 9W wall washer light Light color 3000K, Total lumen output fixture 550similar to the EAN/UPC - product 8727900078251 of Make Philips 284 Supply, Installation, Testing and Commissioning of IP44 5W Foot Light Material: Metal, Color: Anthracite Surface LED Step Light Warm White 2700k Watts: 5W, Lumens: 165lm IP44 fixture ideal for gardens, Metal body with a classy matte finish. Moisture-proof not waterproof. Philips 31436 LED Garden Step Light Product Specification - Color: Anthracite Grey Material: Aluminium Dimension(mm): 201*98*35 Lamp Base: LED. 285 Horticulture Work 286 Preparation of mounds of various size and shape by available excavated/surplus/earth in layers not exceeding 20 cm in depth, breaking clods, watering of each layer, dressing etc.lead upto 50 meters and lift upto 1.5 m as per direction of officers in charge. 287 Supplying and stacking good earth at site of work.Note: 1) Loading, unloading and carriage to be paid extra as peractual lead. 2) Earth measured in stacks will be reduced by 20% foe payment 288 Supply at site of work well decayed farm yard manure, from any available source, approved by the engineer in charge including screening and stacking 289 Spreading of sludge farm yard manure or/ and good earth in required thickness (cost of sludge, farm- yard manure or/and good earth to be paid for separately) 290 Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths ISI marked HDPE pipes of PE-100 grade & PN-6 for potable water as per IS 4984 (amended upto date) in trenches complete with all accessories like Bend, Tee, Reducer, Stub end, End cap etc including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer 110 mm dia 291 Providing, lowering, laying, aligning, fixing in position at and jointing at all level/ depths HDPE Stub End (Long neck pipe end) of PE-100 grade & PN-6 (moulded/ machined) for potable water with MS galvanised flange as per to BS-10 table D/IS:1538 within pipeline in trenches complete including all material, labour, testing and commissioning as per Technical Specifications and as per direction of Engineer.110mm HDPE Stub End (LNPE) with MS Galvanised Slip on flange Suitable for connecting Valve of 100mm dia 292 Labour Charges for Grassing with Carpet grass (selection no. 1)/Doobs grass including watering and maintenance of the lawn for 30 days or more till the grass forms a thick lawn free from weeds and fit for moving including supplying good earth if needed.(The good earth shall be paid separately) 293 In rows 5 cm apart in either direction 294 Making lawns including ploughing and breaking of clod, removal of rubbish, dressing and supplying doobs grass roots and planting at 15 cm apart, including supplying and spreading of farm yard manure at rate of 0.18 cum per 100 sqm. 295 Digging holes in all kinds of soil and refilling the same with the excavated earth mixed with well decayed farm yard manure (cost of well decayed farm yard manure to be paid separately). 296 Hole 0.6 m dia and 0.6 m deep 297 Planting of trees by the road side (Avenue trees) in 0.60 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, planting the saplings, backfilling the trench, watering, fixing the tree guard and maintaining the plants for one year. 298 Providing and fixing of RCC pre cast tree guard consisting of four panels of size 1800mm (Height) X 600mm (Width) X 35mm (thickness); Size of opening: 100mm X 100mm. All the panels shall be manufactured with monolithic legs of size 50 x 35 mm; the legs of the panels shall be 0.5 m below ground level. All the four Panels shall have a space for display of Name etc. preferably at middle level. RCC panels to be manufactured with M-30 grade of concrete using vibro-compaction process using jointless FRP moulds so as to achieve shuttering finish. RCC panels are to be suitably reinforced to promote long use and to prevent damage during handling, transportation & erection as per drawing & specifications. 299 Supply and planting following species best quality container grown healthy trees of 2 mt. min. height, well established & free from disease at site in 0.90 m dia holes, 1 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 300 Plumeria alba ( Champa) 301 Bauhinia blakeana (Arckid) 302 Cassia fistula 303 Callisteomon viminalis 304 Largerstomea speciosa 305 Supply and planting following in poly bags / earthen pots well branched, well established & free from disease of 600 mm min. height shurbs at site in 0.45 m dia holes, 0.45 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 306 Rhaphis excelsa with 3-4 suckers ( Lady Palm) 307 Phonenix sylvertris ( Date Palm) 308 Supply and planting following species best quality container grown healthy trees of 3 mt. min. height, well established & free from disease at site in 1.20 m dia holes, 1.20 m deep dug in the ground, mixing the soil with decayed farm yard/sludge manure, backfilling the hole watering etc as required. 309 Jacaranda mimosifolia 310 Delonix regia 311 Royal palm 312 Cassia Siamea 313 Mimusops elengii 314 Pond Conservation 315 Silt clearance of drains, channels and canals with lift 1.5 Mtr and lead up to 50 Mtr 316 Carriage of Materials by mechanical transport including loading, unloading and stacking ::Sand, bazri, ballast, kankar upto 5 km 317 Providing and laying water proofing treatment to vertical and horizontal surfaces of depressed portions of W.C., kitchen and the like consisting of: i) Ist course of applying cement slurry @ 4.4 Kg/sqm mixed with water proofing compound conforming to IS 2645 in recommended proportions including rounding off junction of vertical and horizontal surface. ii) IInd course of 20mm cement plaster 1:3 (1 cement : 3 coarse sand) mixed with water proofing compound in recommended proportion including rounding off junction of vertical and horizontal surface. iii) IIIrd course of applying blown or residual bitumen applied hot at 1.7 Kg. per sqm of area. iv) IVth course of 400 micron thick PVC sheet. (Overlaps at joints of PVC sheet should be 100 mm wide and pasted to each other with bitumen @ 1.7 Kg/sqm. 318 Finishing walls with water proofing cement paint of required shade : New work (Two or more coats applied @ 3.84 kg/10 sqm 319 Survelliance System 320 Supply, Installation, Testing & Commissioningof Reliable & Secure Bullet Camera, Resolution upto 5 MP , Quad stream with each stream support H.265 , H.264 compression ,fixed focallens 3.6mm or better ,,1/2.8 CMOS sensor Min illumination : Color 0.05lux @ F1.2(AGC ON) ; B/W 0 lux @ IR ON , Shutter Speed : 1/5 ̴ 1/100,000 s , Video Compression : H.265 , H.264 , frame rate : Main stream upto 5MP@25fps , substream upto 2MP@25fps , third and fourth stream upto VGA@25fps . Edge analytics :Motion Detection, Perimeter Intrusion, Line Crossing, Stationary Object, Face detection (deep learning) ,Cross counting , Pedestrian detection ,Inbuilt IR LED , IR distance upto 30 mtrs ,IP 66 , POE ,ONVIF profile S & G . UL , CE ,FCC Certified. Make: Axis/ Pelco/ Impulse/ Tyco/ Avigilon/ Mobotix 321 Supply, Installation, Testing & Commissioningof Reliable & Secure 64 channel NVR upgraded to 128 Channels , ONVIF profile S & G , recording bandwidth 640 Mbps , output interface 1 HDMI (up to 4K), 1 VGA, Alarm in/out :16chin / 4chout , 1 X RJ45 ethernet , iOS smartphone support , 8 HDD support, each HDD slot support upto 8 TB HDD , RAID support , 1x3.0 USBfor backup/upgrade, 2x 2.0 USB for mouse, AI Support ,UL,CE,FCC certified. . Make: Axis/ Pelco/ Impulse/ Tyco/ Avigilon/ Mobotix 322 Supply, Installation, Testing & Commissioning ofSurveillance of Hard Disk 6 TB 323 Network Switch 324 24 port switch fully managed Core switch with 20 Nos of 20 100M/1G SFP Port , 4 Nos of GbE RJ45/SFP Combo Port , 4 Nos of 1G/10G SFP+ Port ,1 X Console , Switching bandwidth 128 Gbps , 32K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN .Device Management system - topology view , floor view ,map view , dashboard , traffic monitoring , cable diagnostics Support IEEE 802.3ad LACP . L3 features - static routing , DHCP server. Make: CISCO/HP/Juniper//Brocade/Camera OEM 325 Supply, Installation, Testing & Commissioningof 24 port L2 Managed switch having port density 24 Nos of 10M/100M/1G RJ45 Port POE /POE+ ports , 2 Nos of GbE RJ45/SFP Combo Port , 1X console port , Available POE power 370 W , 52 Gbps switching bandwidth , 8K MAC address support , Support L2 feature STP, RSTP ,MSTP . Support 802.1Q VLAN , port based VLAN , 4K VLAN entries , MAC based VLAN , IP subnet based VLAN . Support IEEE 802.3ad LACP . L3 features - static routing , DHCP feature , Device Management system - topology view , floor view ,map view , dashboard , traffic monitoring , cable diagnostics.CE,FCC certified. Make: CISCO/HP/Juniper//Brocade/Camera OEM 326 Passive- Fiber Component 327 Supply, Installation, Testing & Commissioning of Optical Cable 6 Core 328 Supply, Installation, Testing & Commissioning of LIU 24 PORT Rack Mount - Loaded 329 Supply, Installation, Testing & Commissioning of LIU 12 PORT Rack Mount - Loaded 330 Supply, Installation, Testing & Commissioning of PATCH CORD 331 Passive- Copper Component 332 Supply, Installation, Testing & Commissioning of CAT6 UTP 23AWG Solid:305M 333 Supply, Installation, Testing & Commissioning of Face Plate+Back Box+Jack 334 Supply, Installation, Testing & Commissioning of CAT6 PATCH CORD:1M 335 Supply, Installation, Testing & Commissioning of CAT6 PATCH CORD:3M 336 Passive- Networking Rack 337 Supply, Installation, Testing & Commissioning of9U rack with all accessories 338 Supply, Installation, Testing & Commissioning of 22 U rack with all accessories 339 UPS 340 Supply, Installation, Testing & Commissioning of UPS for back up of 30 Mins for Edge Switches and Camera 341 Supply, Installation, Testing & Commissioning of UPS for back up of 30 Mins for Centralised Control Room for CCTV 342 Supply, Installation, Testing & Commissioning of 42 LED Screen 343 Road Work 344 Dismantling of flexible pavements and disposal of dismantled materials up to a lead of 50 metres, stacking serviceable and unserviceable materials separately as directed by Engineer. 345 Bituminous courses 346 Granular courses 347 Earth work in excavation for roadway, including trimming bottom and side slopes in accordance with requirement of line, grades and cross sections, including disposal of surplus material with all lift and lead upto 1000 metre as per MoRT&H specification clause 301. 348 In all type of soil 349 Providing, laying, spreading and compacting of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at OMC, carriage of mixed Material to work site, spreading in uniform layers with motor grader on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per MoRT&H specification clause - 401 including all material, labour, machinery, lighting, guarding and maintenance of diversion.Grading - I Material 350 Providing, laying, spreading (with paver finisher only) and compacting wet mix macadam (WMM) base course comprising of graded stone aggregate and granular material conforming to MORT&H specifications (Table 400-II) in layers of equal compacted thickness each consolidated, including pre-mixing the material with water at OMC in mechanical mixer (Pug Mill), carriage of mixed material by tippers to site, laying in uniform layers in base course on a well prepared sub-base/ base course and compacting with power vibratory-roller to achieve the desired density complete as per MoRT&H specification clause - 406 including all material, labour, machinery, lighting, guarding and maintenance of diversion. 351 Providing and applying primer coat over prepared surface of granular base with bitumen emulsion as per IS : 8887 and approved quality @ 0.6 kg/sqm with the help of spray set fitted on bitumen Container (boiler) after cleaning the surface including removing of binding material and other foreign matter with wire brushes and small picks, sweeping with brooms or soft brushes and finally dusting with old gunny bags and compressed air to receive bituminous treatment complete as per clause 502 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 352 Providing and laying 50-75 mm compacted thick design mix (approved by Engineer) Dense Bituminous Macadam on prepared surface with specified graded crushed aggregates as per Table 5009, 500-10 with bitumen binder set (including Cost of anti stripping compound Minimum 1%in Lime/Cement as per design wherever required) for base/ binder course including loading of material with F.E. loader, heating and mixing of stone aggregate, filler and bitumen in computerised hot mix plant, transporting the mixed material by tippers to paver and laying with paver finisher fitted with electronic sensor control as per clause 504.3.5 to the required level and grade, compacting by power rollers and vibratory rollers or 150 to 250 KN pneumatic tyred roller with TP = 0.7 Mpa to achieve the desired density (approximately 2.3 tonne/cum) complete as per clause 507 of MoRT&H specification but excluding primer/tack coat, including all material, labour, machinery, lighting, guarding and maintenance of diversion. 353 Grade-II with Bitumen VG-grade 30 @ 4.25 %, lime filler @ 2%(percent by weight of total mix) 354 Providing and laying 30-45 mm compacted thickness BituminousConcrete as per design mix (approved by Engineer) on preparedsurface with specified grade stone aggregate as per Table - 500-18 with bitumen for wearing course including loading of aggregate withF.E. loader and hot mixing of stone aggregate and bitumen(including Cost of anti stripping compound Minimum 1%inLime/Cement as per design wherever required) in computerised hotmix plant, transporting the mixed material by tippers to paver andlaying with paver finisher fitted with electronic sensing device (as perclause 504-3.5) to the required level and grade and compacting bypower rollers and vibratory rollers or 150 to 250 KN pneumatic tyredroller with TP = 0.7 Mpa, to achieve the desired density complete asper clause 509 of MoRT&H specification including all material,labour, machinery, lighting, guarding and maintenance of diversionbut excluding primer/tack coat. 355 Grade-II with Bitumen VG-grade 30 @ 6% (percent by weight of totalmix) 356 Providing and fixing of retro- reflectorised cautionary, mandatory and informatory sign as per IRC :67 made of encapsulated lens type reflective sheeting vide clause 801.3, fixed over aluminium sheeting, 1.5 mm thick supported on a mild steel angle iron post 3 metre long and size 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 45 cm x 45 cm x 60 cm, 60 cm below ground level as per approved drawing including all material, labour. 80 mm x 60 mm rectangular 357 Supplying and installation of delineators (road way indicators, hazard markers, object markers), 80-100 cm high above ground level, painted black and white in 15 cm wide stripes, fitted with 80 x 100 mm rectangular or 75 mm dia circular reflectorised panels at the top, buried or pressed into the ground and confirming toIRC-79 and the drawings. 358 Providing and fixing precast dense cement concrete M-20 Grade(Vibro-pressed) drain section block of different size as per approved drawing, design and strength as per IS:2185 (part I) of grade D (5.00 N/mm2) proper quality of additive/admixture like plasticizer etc. added to produce high quality and durable drain section Blocks of L shape U shape etc. over 50mm thick CC M15 base course with fixing and joining with C.M.1:4 in proper grade and level complete in all respect. (cost of earth work, steel & welded mesh shall be paid extra). 60 MM Thick 359 Providing and laying lean cement concrete 1:4:8 in Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing complete as per clause 601, 112 of MoRT&H specification including all material, labour, machinery, lighting, guarding and maintenance of diversion. 360 Providing and fixing of precast concrete interlocking tiles of desired shape of M 30 grade manufactured from fully computerized automatic stationery hydraulic vibrio pressed machine and fully computerized automatic batching plant of class A1/A2 as per BS 6717:2001. The CC interlocking paving blocks be laid on average 60mm. thick bed of coarse sand and the joint is to be filled with fine sand. Laying procedure on compacted sub-base as defined. Complete job is to be executed as per the instruction of Engineer in charge. The rates to be inclusive of all lead & Lifts etc. complete as per specifications. Tensile splitting strength, abrasion and braking load etc. as per BS 6717:2001, Grey cement. 361 ProvidingandfixingprecastcementconcreteM-20grade(Using mechanicalConcreteMixer)kerbstonetopandbottomwidth115 and 165 mm respectively, 250 mm high on 150 mm thick PCC M-10 grade foundation as per design, including fixing at site as per clause 408ofMoRT&HSpecificationincludingallmaterial,labour, machinery, lighting, guarding and maintenance of diversion. 362 Solar Panel 363 Supply, installation testing and commissioning of MNRE approved Grid tied Solar Panels with inverter, meter, cable etc. suitable for Rooftop installation as well as Unility Scale Solar Power Projects with 25 years of linear generation warranty, Work includes designing of solar panel area and MS frame and foundation on ground/roof of Pump house or CWR, showing arrangement of panel in available space. Installation of PV module on MS frame as per approved design and drawings. Mounting structure shall be suitably designed to withstand wind velocity up to 150km/hr. Grid Tie Transformer less inverters, Multiple independent MPPTs, Peak efficiency of >98%. Connect up to multiple strings PV arrays. Easy & fast connection, Built in string level monitoring, IP 65 protection level, Wi-Fi/ internet based remote monitoring with 5 years warranty. All cabling up to panel and metre, earthing etc. required accessories and taxes are inclusive. The work shall be executed as per detailed technical specifications, approved drawing and direction of Engineer in Charge. Note: There shall be 5 year service warranty for panel, inverter meter, cable etc, and suitable provision shall be included in tender document 364 Solar panels up to 10 KW at a single location 365 PlayGround 366 Providing and Installation of Multipurpose kids play equipment includes Slides, walking, Climbing, hanging, etc. activity in a single tower. FRP Outdoor Kids Play Equipment, Size: 7.4 X 4 M, Capacity: 8-10. All Steel Components are APL Apollo brand I.S.I. mark pipes with powder coated with anti-rusting treatment and all FRP components are paint by high quality PU paint in 03 layers.Complete in all respect as per directions of Engineer incharge. 367 Providing and fixing Steel Merry Go Round equipment for kids park made up of Galvenized steel finish, Size: 2 M Dia, Capacity: 4-5 kids. Complete in all respect as per directions of Engineer IN-charge. 368 Providing and fixing Iron FRP Double Seesaw equipment for kids park Play Area 4.0 X 2.5 m Loading Capacity 100-200 Kg. Complete in all respect as per directions of Engineer IN-charge. 369 Providing and fixing Iron S Shape Climbers Shape Climber, Capacity: 10 Children. Dimension 3.5 x 2 x 2.1 m. (11.4 x 6 x 7 ft.). Complete in all respect as per directions of Engineer IN-charge. 370 Fountain 371 Providing and Installation of Multicolor Floating Water Fountain, Made up of brass or SS, Nozzle Type Finger Jet Nozzle, Multidimension Nozzle, Nozzle dia 10-30 mm, Fountain Height: upto 25 Feet, Electric motor of 4 HP of frequency 50-60 Hz.Complete in all respect as per directions of Engineer incharge. 372 Providing and Fixing Floor Recessed Grid Assembly with fountain Nozzle and LED lights, Body Material: Stainless Steel 304 grade with stainless steel finish and LED lighting with colour: RGB/WWW/CW/R/B/G. Complete in all respect as per directions of Engineer incharge. 373 Primary Treatment 374 Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in- charge. 375 In cement mortar 376 Dismantling of existing structures like culverts, bridges, retaining walls, CC road and other structure comprising of masonry, cement concrete, wood work, steel work, including T&P and scaffolding wherever necessary, sorting the dismantled material, disposal of unserviceable material and stacking the serviceable material with all lifts and lead of 50 metres as directed by Engineer 377 Cement Concrete Grade M-15 and above and PCC blocks 378 Dismantling Stone Masonry 379 Dry rubble masonry 380 Diluting and injection Chloropyrifos Emulsifiable concentrate 20% with 1% concentration for PRE-CONSTRUCTIONAL Anti termite treatment as per IS 6313 part III as amended from time to time and creating a continuous chemical barrier under and around the column pits, wall trenches, basement excavation, top surface of plinth filling, junction of wall and floor along the external perimeter of building expansion joints, over the top surface of consolidated earth of which approach is to be laid surrounding of pipes and conduits etc. complete as per specification (Plinth floor area only shall be measured for payment and excluding the cost of chemical emulsion). 381 Providing and laying in position cement concrete of specified grade excluding the cost of centring and shuttering - All work upto plinth level : 382 1:4:8 (1 Cement : 4 fine/ coarse sand : 8 graded stone aggregate 40 mm nominal size). 383 Reinforced cement concrete work inbeams, suspended floors, roofs having slope upto 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto two stories excluding the cost of centring, shuttering, finishing and reinforcement: including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06mm/12 mm length to be mixed @0.25% by weight of Cement ie125 gms per50kg Cement up to 900 gms per cum of Concrete/mortar 384 M-25 Grade Concrete (1:1:2 (1 cement : 1 coarse sand : 2 graded stone aggregate 20 mm nominal size) -As per design mix) 385 Random rubble masonry with hard stone in foundation and plinth : 386 Cement mortar 1:4 (1 cement : 4 coarse sand) 387 Brick work with FPS bricks of class designation 75 in superstructure above plinth level upto two stories in all shapes and sizes in : 388 Cement mortar 1:4 (1 cement : 4 coarse sand) 389 Cement plastering including T&P, scaffolding, material and complete labour, including cost of water, curing, racking of joints etc. with 15 mm cement plaster on the rough side of single or half brick wall of mix : including Providing /mixing of synthetic fibers compulsorily complying with IS 16481:2022 of 06mm/12 mm length to be mixed @0.25% by weight of Cement ie125 gms per50kg Cement up to 900 gms per cum of Concrete/mortar 390 1:4 (1 cement : 4 fine/ coarse sand) 391 Providing corrugated G.S. sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and G.I. impet washers or with G.I. limpet washers filled with white lead and including a coat of approved steel primer and two coats of approved paint on overlapping of sheetscomplete upto any pitch in horizontal/ vertical or curved surfaces) excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. 392 1.00mm thick with zinc coating not less than 275gm/m² 393 Supply, fabrication, fixing and Testing of stainless steel (SS-316) Manual Coarse Bar screen with flat bar 50mm X 10mm, Spacing of bars 50mm suitable for mounting in channel of specified size with inclination not more than 45 degree and a movable covered containers of 1 cum capacity complete in all respect as per technical specification and the direction of the Engineer. Manually Raked Coarse Bar Screen with 50 mm clear opening for following PEAK FLOW and upto 3m channel depth. 394 3.1 MLD to 5 MLD 395 Construction of RCC chamber for different type of Drain including earthwork excavation, 100mm PCC M10 (1:3:6 (1 Cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) as leveling course, RCC M20 grade (1:1½:3 (1 Cement : 1½ coarse sand : 3 graded stone aggregate 20mm nominal size) for base slab, side wall , including cost of steel reinforcement not less than 80kg per cum CC, form work, proper curing of concrete work complete in all respect as per standard specifications and drawings and as directed by Engineer. 396 Chamber-4 (1200 x 1200 x 1500 mm) 397 Supply, Installation, Testing and commissioning of CI Open Channel SluiceGates,Manuallyoperated,RisingSpindletypesuitablefor mountinginbetweentwo parallelwallsof an OpenChannel. Water sealingshallbeprovidedattwoverticalsidesandbottomsideof gateaperturebymeansofrubberseal,mountedongateslideand having forced contact with gate aperture. The gate shall be designed in such a manner, so that it can be operated at 2 meter head. Gate frame&ShutterofCIGradeIS210FG260,HeadStockIS210 Grade FG 260, Hinge Pin SS ASTMA276, Yoke IS MS 2062, Flush BottomSealSupportBarofSSASTMA276,StemOperatingNut ASTM A276., Duly tested for tensile strength, Chemical testing and testedShoptestedforoveralldimensionsasperapprovedGA drawing complete in all respect as per specification and direction of Engineer for following PEAK FLOW up to 3m channel depth. 398 Up to 5 MLD 399 Supply, fabrication and fixing of stainless steel (SS-316) CoarseBar screen (mechanically raked) with flatbar 50mm X 10mm Spacing of bars50mmsuitableformountinginchannelofspecifiedsizewith inclinationnotmorethan75degreecompleteinallrespectasper technicalspecificationandthedirectionoftheEngineerfor following PEAK FLOW and upto 3m channel depth. 400 5 MLD to 10 MLD 401 Chlorination Package 402 Cost of E&I Systems 403 Chattri 404 Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. 405 Carriage of Materials by mechanical transport including loading, unloading and stacking - for 5 Km. (Stone, boulders, gravelly material) 406 Providing and fixing double scaffolding system (cup lock type) on the exteriorside,uptosevenstoryheightmadewith40mmdia.M.S. tube1.5mcentretocentrehorizontal&verticaltubesjoiningwith cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps andM.S.staircasesysteminthescaffoldingforworkingplatform etc.andmaintainingitinaserviceableconditionfortherequired durationasapprovedandremovingitthereafter.Thescaffolding system shall be stiffened with bracings, runners, connection with the buildingetcwhereverrequiredforinspectionofworkatrequired locationswithessentialsafetyfeaturesfortheworkmenetc. complete as per directions and approval of Engineer-in-charge .The elevationalareaofthescaffoldingshallbemeasuredforpayment purpose .The payment will be made once irrespective of duration of scaffolding. (To be used for maintenance work judicially . necessary deduction for scaffolding in the existing item to be done.) 407 P & L Lime Surkhi Plaster lime surkhi mortar 1:2 (1 Lime : 2 Surkhi) including preparation of mortar by traditional practice (by grinding) in specified course for base coarse and subsequent course & Loi, tamping, beating, curing till the shrinkage cracks are disappear. The work is to be done with all lead as the work is of restoration nature as per Jaipur practice including adding gur, methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 days of previous coat. 408 45 mm thick in four coats 409 Making Mehrabs, Arches, pillars, highly decorative creepers, flower of small sizes etc.in lime Surkhi plaster (1:2) as per B248old traditional practices (Arches, Mehrabs) in three coats for base course and subsequent course and Loi tamping, beating till the shrinkage cracks are disappear than making ornamental flowering/design etc. The work is to done with all leads and lifts as per work of restoration nature as per Jaipur practice. 410 Add extra for Lime plaster work done over flat ceiling. (20%) 411 Add extra over item no. 40.5 to 40.6 for Lime plaster work done over curved/circular masonary work (curved or circular surface.) 412 Flush and ruled pointing over joints of dressed stone cladding, chajjas, jali etc. including racking the joints as per traditional practice including all leads and lifts with grinded mortar of lime putty and fine sand mixed in 1:2 ratio and gur, methi, gugal etc. are to be mixed as per traditional practice. 413 Khamira Colour Washing as per old traditional practice to prepare the Khamira the lime should be slaked at least for 7-10 days and regularly it should be stirred by adding cured, Gugal, for nonsynthetic colour adding gum (babool gum) as per specification. Then applying prepared solution on walls three to four thin coats as desired finishing. 414 Stucco work in lime, Surkhi, mortar (1:2) as per existing design work/traditional practices by skilled craftsman, the stucco work should be done as per restoration nature, the mortar should be prepared by grinding mill adding gur, methi & gugal.. The thickness varies from 50 mm to 100mm as per the design (minimum rectangular surface area to be measured). 415 Providing & applying Lime kara 1:2 (1lime cream : 2 Zikki powder) grinding mortar with grinding mill/manually on lime base, on ceiling and all flat surface in two coats. First coat applying 3 mm to 4 mm thick and curing properly at least 7 days, second finishing coat done after 7 days of previous coat as per traditional practice.(thickness not more than 6 mm.) 416 Add extra for Lime Kara work (on lime plaster base) other than flat surface as per traditional practice with all lead & lift with fine finishing complete in all respect on : 417 (a) domical surface/spherical/domical ceiling. 418 Providing & applying Lime Kara on stone work only having carving stone work /decorative stone work (stone pillars, stone arches, railing etc.) as per traditional practice, as per specifications with grinded mortar in two coats with finishing complete in all respect. 419 Scraping & Removing of white wash/ distemper/oil paint/algli etc. from lime plaster highly decorative, ornamental and stucco work with at most care by using fine sand paper under the close supervision to keep intact the old designs. 420 De-vegetation from monument by removing bushes, trees including complete uprooting from the wall & roofs/structures carefully including suitable chemical treatment to roots to avoid further growth including disposal of rubbish with in 50 mtr. Lead as per direction of Engineer in-charge. 421 Water proofing with consolidation of basic substrata, making it complete water proofwith Protekta series of compounds of equivalent as per manufacturers specifications and as per directions of engineer in chrage. 422 Chemical treatment of sand stone to clean from yellowness, blackness, algal growth, dust, dirt oily accretions, lime & gypsum deposits, filling of cracks/ joining of gaps/ pointing, strengthening of weak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof. 423 Chemical treatment of marble stone to clean from yellowness, blackness, algal growth, dust, dirt oily accretions, lime & gypsum deposits, filling of cracks/ joining of gaps/ pointing, strengthening of weak stone, removal of salt effect and application of preservative coating to prevent algal growth and make the stone water proof. 424 Removal , providing and re fixing of stone dasa moulded as per existing design with fine finishing fixing ingrinded lime mortar 1:2 i/c all lead and lift complete in all respect. extra for carving (pan patti)-100mm thick 425 Making Kangura on top of the wall as per Jaipur traditional practice with tile brick bats/stones in grinded Lime Surkhi mortar 1:2 thickness of kangoora 15cm & height 45cm, finishing with lime Surkhi mortar 1:2 complete in all respect up to 10.00 meter from ground level including all scaffolding, lead & lift. 426 Providing and fixing fine dressed sand stone/approved stone Traditional work as per existing matching geometrical design including molding work with fine finishing,fixing with tham+C23bli by proper adhesive and white cement with pigment including making groove etc. complete in all respect. 427 Providing and applying ceilent adhesive to existing cracks by suitable silicon or equivalent ceilent complete in all respect and making it complete water-proof as per direction of the Engineer-in charge. 428 Providing and applying breathable, non-reactive, transparent, antifungal, UV resistant, alkaline stable, impregnable silane-siloxane or equivalent based water repellent coating on exposed absorbing substrate like stone surface/ concrete surface/ mineral painted surface / exposed brick surface / lime surface in two or more coats to give uniform finish surface in all heights, horizontal, inclined, vertical and on ceiling complete in all respect and making it complete water-proof as per direction of the Engineer-in charge. 429 Providing & fixing bamboo base deck at water surface level in lake to provide supporting platform for working and to support wall scaffolding above water level. The deck will include bamboo frame work under water. Horizontal MS frame and MS sheet covering to stop damage malba and other material to fall in water and maintaining in servicable condition for the required duration. The work includes provision of floating pontoon to carry material in and out of water, the bamboo base deck shall be stiffened with bracings, runners, connectors, with nearby structures etc. wherever location with essential safety features for the workmen etc. complete as per directions of engineer in charge 430 Making Gardana under ceiling/ chajja with katla stone and grinded Lime surkhi mortar 1:2 including moulding work and fine finishing with grinded Lime surkhi mortar 1:2 as per existing matching/ traditional practice completev in all respect. (Size 35cm X 35cm.) 431 MakingBend -patta, Cornice, Gola & String course with katla stone andLime surkhi mortar 1:2 (projected ) and finishing with grinded Lime surkhi mortar 1:2 including moulding/ design work as per existing matching at site complete in all respect. (Size 15cm X 10cm.) 432 Providing and fixing Corrugated surface sand stone/approved stone flooring for ramp-way with fine dressed corrugation work as per approved design and size over a base of of grinded Lime surkhi mortar 1:2 and jointed with masaldarlime putty and stone powder 1:1 with an adixure of pigment, complete in all respect, as per direction of Engineer Incharge. ((b) 100 mm. stone slab) 433 Providing & fixing fine dressed machine cut sand stone Stone steps (Treads & risers) with round nising as per existing matching fixing in lime surkhi mortar 1:2 including pointing in lime cream and stone dust 1:1 with an admixture (50mm to 60mm thick) 434 Providing and fixing Stone Kalasha as per existing matching on doms od chattries/jharokhas as per existing design & dimensions as per traditional practices, fixing of kalash carefully without damaging the doms complete in all respect. (i) Kalasha height.(exposed part) 45cm. to 60cm. 435 Providing and spray/brushing of Gur, gugal & methi solution for bonding of lime work as per specification (200gm gugal, 200gm belgiri powder, 200gm methi powder and 1 kg. Gur mixed in 20litre water and boiled and sttired till the solution volume reduce upto 3/4th) using 15.00litre solution in 10.00sqm. area. 436 Providing and fixing fine dressed sand stone flooring with white sand stone (Bansh paharpur/dholpur stone) (panji marked surface) machine cut of approved shade set in pattern over 30mm thick base of lime surkhi mortar 1:2 including jointing finished flush with lime putty and stone powder with an admixture of pigment as per direction of Engineer incharge. (75mm thick) 437 Providing and fixing fine dressed sand stone Todies (Brackets) as per existing matching stone with moulding work with fine finishing , fixing in grinded lime surkhi mortar 1:2 including scaffolding, lead & lift complete in all respect. 438 (b)Size : 60cm X 45cm X 7.50cm (exposed part only.) 439 Providing and fixing of fine dressed stone Steps (solid) of temple with matching stone/ approved quarry fixing of steps as per temple architecture by machanical/ mannual system carefully in proper order and sequence including all lead & lift as per direction ofEngineer incharge. 440 Providing & fixing ornamental stone cladding of approved sand stone with dressing complete as per existing design/pattern/approved design,fixing with 30mm thickgrinded lime surkhi mortar 1:2 & pointing with white cement with araldite and pigment to match shade the stone complete in all respect as per direction of Engineer incharge.(75mm thick) 441 Removal and refixing of stone chajja 50 to 75mm thick, stone used to be similar to the existing ones at the site, cutting in proper shape and providing interlocking keys in the new as well as old stone for proper bonding including finishing the edges in all respects in lime surkhi mortar (1 lime putty : 2 surkhi). 442 Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in lime mortar 1:2 (1lime : 2coarse sand), including making the necessary chases. 443 Providing & Fixing HDP Dustbins of 40 Liter Capacity (Wet & Dry seperatly) fixed CC foundation with MS pipe frames, complete in all respect as directed by engineer incharge. 444 Providing,carving and Fixing of building signages inapproved sand stoneof size 750x450x50 mm. Engraving,painting of latters as per drawing and design. The signage stone shall be fixed on the building wall complete as per details and drawings and as directed by engineer incharge. 445 Baoris 446 Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.. 447 Carriage of Materials by mechanical transport including loading, unloading and stacking - for 5 Km. 448 Earth 449 Add extra for Lime plaster work done over flat ceiling. (20%) 450 Tuman masonry by brick bats/ stones in grinded mortar of Lime Surkhi mortar 1:2/lime sand mortar 1:2 including racking and removal of all old loose plaster and cleaning the wall surface properly as per direction of Engineer In-charge. 451 Providing and fixing stone Patties (slab) on roofing including removing broken patties carefully and replacement new slab with Kharanja, ralthal andlime dhar as per traditional practice. Span about 3.30 mtr. To 5.50 mtr. 100 mm to 150 mm thick of approved stone. 452 Providing and laying lime Dhar on roofing as per Rajasthan, Jaipur traditional practice with lime, Surkhi, old lime powder, brick aggregate 12 to 20mm (1:2:2:2) and using Methi, Gur, Hemp, Belgiri etc. including beating and temping 100 to 150 mm thick as per specifications. Including dismantling of old detoriated roofing 453 Painting on Stucco work with stone colours including base coat of khameera as per traditional practice (minimum rectangular to be measured). 454 Providing and fixing fine dressed sand stone Dasa/coping as per existing matching , fixing in grinded lime surkhi mortar 1:2 including pointing in cream and stone powder 1:1 with an admixture of pigment to match the shade of stone complete in all respect. 455 (b) above 100mm to 150mm thick plain with fine dressing. 456 (d) above 100mm to 150mm thick with pan patti design. 457 Stone flooring work with chisel dressed surface of approved shade and quarry in irregular shape as per existing pattern on a base of grinded lime sand mortar 30mm thick and jointing with masaldar lime putty and stone dust mixed in 1:1 ratio with admixture of pigment (75mm thick) stone as per existing matching. 458 Random Rubble stone masonary for foundation and plinth in Lime surkhi mortar 1:2 above 30cm. thick walls in : ( 1 Lime putty : 2 Surkhi including adding admixture like gur, methi etc. in mortar.) 459 Random Rubble stone masonary for superstructure, 4.50mtr. Height above plinth level/ one storey height above 30cm. thick walls in : Lime surkhi mortar 1:2 ( 1 Lime putty : 2 Surkhi including adding admixture like gur, methi etc. in mortar.) 460 Providing and laying lime concrete in foundation and plinth using 40% lime mortar and 20mm nominal size graded aggregate (crusher broken ) including ramming and watering complete in all respect comprising of : ( 1 Lime putty : 2 Surkhi mortar.) 461 Site clearance by uprooting of trunk vegetation, bush, wood, trees and sapplings of girth upto 15cms and disposal of rubbish with in 50mtr. Including leveling and dressing of ground as per direction of Engineer incharge. 462 Stitching of masonrycracksby mechanical means by careful removal of the plaster and masonry of approximately 450mm to 900mm wide and 100 mm deep, removing all loose materials, cleaning with pressure water jets andfilling 1/3 rd depth with lime mortar 1:1:1:1 (1 lime : 1 fine sand :1 khakha : 1surkhi) over the cracked area by pressure grouting machine, then covering it with lime mortar 1:1:1:1 ( 1 lime: 1 fine sand: 1 khakha: 1 surkhi ) and finally grouted with liquid mortar complete and matching the existing condition and features of masonry. Cross masonry stitching in selective areas with matching bricks and lime mortar 1:1:1:1 (1 lime: 1 fine sand :1 khakha : 1surkhi) matching the courses of existing masonry under the supervision of the principal consultant (conservation architect). 463 Sludge clearance of drains, channels and canals with lift 1.5 Mtr andlead up to 50 Mtr. 464 Providing/Carving/Fixing approved sand stone 2 Mt long benches with 75 mm thick pan patta dasa top fixed in stone pair as per detail drawings,design and as directed by engineer incharge complete in all respect. 465 Gates 466 P & L Lime Surkhi Plaster 1:2 (1 Lime : 2 Surkhi) including preparation of mortar by traditional practice (by grinding) in specified course for base coarse and subsequent course & Loi, tamping, beating, curring till the shrinkage cracks are disappear. The work is to be done with all lead as the work is of restoration nature as per Bundi practice including adding gur,methi & gugal on old walls including removal of all old loose and decade plaster, each coat to be done after 3 days of previous coat. 467 33 mm thick in four coats 468 Add extra over item no. 40.5 to 40.6 for Lime plaster work done over spherical or groin ceiling / ladao ceiling of doms 469 Add extra over item no. 40.5 to 40.6 for Lime plaster work done over flat ceiling 470 Add extra over item no. 40.5 to 40.6 for Lime plaster work done over curved/circular masonary work (curved or circular surface.) 471 Removing of old lime plaster up to 75 mm thick in patches with height up to 4.5 m. Disposal up to 100 meter lead. 472 Scraping & Removing of white wash/ distemper/algli etc. from plain plaster & surfaces gently with care to keep intact the old designs. 473 Conservation of oil painting and portraitsin munuments by cleaning of the painted surface from all types of stains, dust, dirt, greasy & oily accretions etc. With the help of suitable chemicals, removal of cracks and holes, consolidation of flaking paint layer and plaster, filling of the lacunae in the plaster, treatment of salt effect, retouching of the lost portions and providing a preservative coating. 474 Providing and Fixing fine dressed sand stone /approved stone Chajja for palaces,chattries,forts and jharokas with fine dressed surface both sides and front edges should be round shape/moulding, fixing in grinded lime surkhi mortar 1:2 joint flush with proper adhesive with pigment to match the shade of stone (thickness of chajja on front edge50mm and 75mm on fixing end) exposed surface is to be measured only. 475 Repairing of existing historic window/doors for hardware, rotten/ deteriorated parts. Proper fixing and making it operational with locking possibility including moulding, carving and polishing complete as per details and drawings and as directed by engineer incharge. 476 Providing and fixing in position Red Sand Stone Kerb of size 150 mmx300 mm and cut to shape as per with exposed face fine chiesel dresses fixing and jointing/pointing with cement mortar 1:4 using pigment as per drawing and instruction of Enineer Incharge complete in all respect. 477 Electrical Fitting 478 P & F of IP 55 protected light controlled switch based on infrared sensing and daylight with built in over load protection, timer to switch OFF at preselected time. Switch shall have 7 day power backup without hampering of preset time and over ride facility for maintenance purpose 479 Suitable for 3 kw load direct lighting load (single phase) 480 P & F of IP68, IK10 protected LED Buried marker light /Step Light Fixture. Fixture made of powder coated die cast aluminium with Toughened Glass cover and appropriate beam angle lens to be used as per requirement. The System level Luminous efficacy must be >90 Lumen/W. High Power LEDs at 1W/2W per LED. The driving current should be Minimum 350 mA per LED. CRI>70, CCT: 3000/6500 K. The integral SMPS based electronic driver must be constant current and surge protection of min. 4KV(L-N) and efficiency >85%, PF>0.9 and input Voltage range of 90-270V AC at 50Hz. System life of 50000 Burning hours with 70% of Initial Lumens maintained. Light should include quick connecting cable coupled with various mounting accessories. Light output in Cool white or Warm White Colour as per engineers choice. Fixture must be in compliance with IS/CE Standards. 481 Burial Light - 5W L-7 482 Rectangular LED Marker Light 483 P &L of lP66 protected high power high power LED linear flood light system. Fixture made of powder coated extruded aluminium housing with UV stabilized PC/toughened glass cover and appropriate lens tobe used to achieve various beam angle pattern. fixture suitable for input 12vDC, power consumption should be 6W/0.5A per feet with system CRI- 70, color red/ green / blue/ /RGB /W/WW. the fixture must have IP66 protected 5mm Round female connector for input, the fixture must have provision to extend further . system life of 50000burning hours with 70% of initial lumens maintained . light output in red, green, blue, cool, white or warm white colour as per requirement. fixtures shall be CE complete series of linear flood light. 484 Linear LED Strip 2 Feet (with Driver) 485 Linear LED Strip 4 Feet (with Driver) 486 Distribution Board 487 Providing & Fixing of 240/415 V Residual current circuit breaker (RCCB) conforming to (IS:12640-1)/ IEC 61008 -1 , rated 4 KV impulse withstand voltage truly current operated and shall operate on CBCT mechanisum, provision for pad lock,min. operation 10,000 upto 63 A rating and5000 for 100 Aratingand minimum phase termination capacity of 35 sq.mm. rigid wire, IP 20 contact protection with existing distribution board / sheetincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure A attached with this BSR 488 Two pole 30 mA sensitivity 16/25 A rating 489 PVC Wiring Conduit 490 S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III ) PVC conduit along withISI marked (IS:3419-1988) accessories as requiredinrecessincludingcutting the wall, covering conduit and making good the same as required. For additional technical parameters of product / work refer Annexure A attached with this BSR 491 25 mm 492 32 mm 493 Wiring of 6 pin 15 amp. Light power point with 4.0 sq.mm PVC insulated unsheathed solid / stranded copper conductor 1.1 kV grade of approved make in surface /recessed ISI marked steel conduit & its accessories, 18 SWG M.S. box with earth terminal, screw less cage connectors for neutral looping in switch board , 15A switch, 15 A socket, 3.0 mm thick phenolic laminated sheet, zinc plated / brass screws, cup washers, bushes, check nuts, making connections, testing etc. as required. 494 Short point (up to 3 mtr.) 495 Medium point (up to 6 mtr.) 496 Long point (up to 10 mtr.) 497 Earthing 498 Plate Earthingas per IS:3043 with Hot dipped G.I. Earth plate of size 600mm x 600mm x 6.0mm by embodying3 to 4 mtr. below the ground level with 20mm dia. G.I. B class watering Pipe ,including all accessories like nut, bolts, reducer, nipple, wire meshed funnel, and Heavy duty weather proof poly-propylene earth pit chamber with lockable Jam free lid suitable for safe working load 5000 Kg or more of size Top Dia. 225 to 260 mm, Bottom Dia 300 to 350 mm. and Height250 to 300 mm. and embodying the pipecomplete with alternate layers salt and coke/ charcoal, testing of earth resistance for value of 5 ohms or lessas required & must record by engineer in charge during site visit and ensure to enter in measurment book.All as per pre approved by Engineer in charge.For additional technical parameters of products/ work, refer Annexure A attached with this BSR . 499 Cable & Wiring 500 Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5,in existingsurface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure A attached with this BSR 501 2 x 2.5 sq.mm 502 2 x 4.0 sq.mm 503 P&F of thermoplastic/ PVC cable junction boxes (United/ HPL make) of following sizes including clamps for holding the box, cost of DIN rail for MCB mounting, connectors for cables terminals, threaded cable glands made of polyamide material etc. complete in all respect. 504 300mm X 200mm X125mm 505 Labour charges for Excavation of 30cmx75cm size trench in CC road including refilling of excavated earth,compactionof earth, making good the same complete as required . 506 Providing & Laying of 25 cm thick layer of river sand to cover of existing cable in 30cmx75cm size cable trench with levelling and making symmetric 25 mm thick layer in complete running length of trench as required. 507 Providing & Laying P.V.C. / XLPE insulated & P.V.C. sheathed ArrmouredAluminiumcable confirming to IS:1554 P-I / IS :7098 P - I of 1.1 KV withH4- Grade electrolyticaluminium conductor confirming to IS 8130 of purity >99.6 %, round / flat strip armouring of cables, Inner / outer sheath confirming to IS:5831in existing RCC / Hume / Stoneware / PVC pipe/ open duct/cable trench / Cable tray(with cable tie) includingtesting etc. as required of following size. OEM must have its own in house NABL accrediated Laboratory for testing procedure as per IS:10810.For additional technical parameters of product / work refer Annexure A attached with this BSR 508 Armoured Cable 509 4.0 Sq. mm 510 2 core 511 Supply, Installation, Testing and Commissioning of Spike Light of6Watt and10 Degree Beam Deflection and 3000 K CCT 512 Supply, Installation, Testing and Commissioning of Spike Light of12Watt and10 Degree Beam Deflection and 3000 K CCT 513 Decorative haritage pole in 4 Meter height. Pole upper section of length 3mtr is of dia 76mm and 1 meter bottom section of dia 114mm with decorative casting with base plate as per drawing. Provision for inside termination box with 4way connector & 1nos 6 AMPS MCB for local isolation with cover.Complete in all aspects with foundation bolts 514 4.0 Mtr 515 Supply of Queen post top light in 30W LED IP65. Light fixture is made with corrosion resistant die cast aluminium. Height of the fixture is 850mm with width 500mm die cast base of dia 60mm closed by diffuser with durable proper silicone rubber gasket. Fitting is IP66 wired with Branded OSRAM or equivalent make LED and Fulham constant current driver. Proper thermal management for longer life of fixture. Fitting is suitable with heritage Decorative cast aluminium pole of 3mtr with cast aluminium emblishment with base od dia 300mm base plate 350x350x14mm as per shared drawing. Fitting is suitable for outoor application complete in all aspects with all accessories. 516 Part E,Employer Representatives Site office 517 Cost of establishment of office accomodation of 300 sq. ft. as per contract clause no. 6.28 including power, telephone and water charges, Rate shall be quoted on monthly basis ( maximum 18 months) andcost of Office operations 518 Provision of Provisional sum to be used as tender document (fixed) : INR 50,00,000. Bidder should fill amount INR 50,00,000