| 1 | Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including taking out the excavated soil and depositing and refilling of jhiri with watering & ramming and disposal of surplus excavated soil as directed with in a lead of 50 meter. All kinds of soils |
| 2 | Supplying and Filling in plinth with blown sand under floors including watering ramming consolidating and dressing complete including cost of sand. |
| 3 | Providing and laying in position cement concrete including curing, compaction etc. complete in specified grade excluding the cost of centering and shuttering - All work up to plinth level.1: 4: 8 (1 cement : 4 coarse sand : 8 graded stoneaggregate 20mm nominal size). |
| 4 | Random Rubble stone masonry for with hard stone in foundation and plinth in Cement Sand mortar above 30 CM thick wall in: Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 5 | Providing and laying in position specified grade ofcement concrete forall RCC structural elements upto plinth level including curing, compaction, finishing with rendering in cement sand mortar 1:3 (1 cement: 3 coarse sand) and making good the joints and cost of plastizers( if required) excluding the cost of centering, shuttering and reinforcement. M20 grade Nominal Mix / Design Mix |
| 6 | Centering and Shuttering with plywood or steel sheets including strutting, propping bracing both ways and removal of formwork for foundation , footings,strap beam, raft , bases of columns etc. |
| 7 | Providing and fabricating reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding (including cost of binding wire) all complete up to floor five level. (\"Original producers\" who manufacture billet directly from iron ores and roll the bilets to produce steel conforming to IS:1786) Thermo-mechanically Treated bars (Conforming of relevent IS code) |
| 8 | Random Rubble stone masonry with hard stone in superstructure aboveplinth level and upto five levelabove 30cm. thick walls in : Cement Mortar 1:6 ( 1-Cement : 6-Sand). |
| 9 | Add extra for Random Rubble stone masonry with hard stone in : Square or Rectangular pillars |
| 10 | Brick work with F.P.S. bricks of class designation 75 in superstructure above plinth level upto floor V level in all shapes and sizes in :Cement mortar 1 : 4 (1 cement : 4 coarse sand) |
| 11 | Add extra for Square or Rectangular Pillars in Superstructre brick work up to five storey |
| 12 | Providing and laying cement concrete including curing, compaction etc. complete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, levelling course etc up to floor five level excluding the cost of centering and shuttering : M20 grade Nominal Mix1: 1.5: 3 (1 cement : 1.5 coarse sand : 3 graded stoneaggregate 20mm nominal size). |
| 13 | Providing and laying damp-proof course with cement concrete grade M-150 (1 : 2 : 4) mortar prepared with 1% solution of water-proof compound complete as per specification : 50mm thick. |
| 14 | Repairs to plaster of thickness 12mm to 20mm in patches of area 2.5 sq. metres and under including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50 m lead With cement mortar 1 :4 ( 1 cement : 4 coarse sand) |
| 15 | Repair to damaged RCC slabs, beams and columns etc for strengthening with cement mortar 1 : 2 in following steps :-(i) Choping losse and cracked concrete to required depth, cleaning the exposed surface of steel and concrete with wire brush and sand papering , cleaning of concrete surface with water as necessary and getting dried.(ii) Applying Epoxy primer on the exposed steel bars.(iii) Applying Epoxy hardener and resin mix (as per manufectured\"s specification) on concrete and steel bars with brush.(iv) Speading dry cement mortar 1 : 2 mix over epoxy treated wet surface and allow it to dry for one day.(v) Plastering the surface with cement sand mortar 1 : 3 upto depth of 30mm complete.(vi) Cure the plastered surface for 15 days, All work including scaffolding etc. complete in all respect. |
| 16 | Dismantling old plaster or skirting, raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 meter lead. |
| 17 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 25 mm thick. |
| 18 | Plaster on new surface on walls in cement sand mortar 1:4 including rackingofjointsetc. complete fine finish : 20 mm thick. |
| 19 | Pointingonstonemasonryincementsandmortar 1:3 (1 cement : 3 sand) :Flush / Ruled/ Struck or weathered pointing. |
| 20 | Structural steel work riveted,bolted or welded in built up sections, trusses and framed work, including cutting, hoisting (height upto 10 m) , fixing in position and applying a priming coat of approved steel primer all complete. |
| 21 | Add or deduct for each wire line over basic item, Extra for using galvanized barbed wire instead of black barbed wire. |
| 22 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : In cement mortar. |
| 23 | Supplying and fixing of chain link fencing with angle iron posts 50x50x6mm placed at every 3 Mtr. apart 30cm in ground embedded in cement concrete 1:3:6 (30x30x45cm) corner and every tenth post to be strutted with (50 x 50 x 6cm) angle iron provided and fixed and fitted with posts including earth work in excavation etc. complete with chain link size 50mm x 50mm x 3.15mm |
| 24 | Finishing wall with water proofing cement paint of approved brand and manufacture and or required shadetogive an even shade including all scaffolding: New work (Two or more coats applied @ 3.84 kg/10 sqm). |
| 25 | Wall painting with plastic emulsion paint of approved brand and manufacture to give an even shade including all scaffolding:Two or more coats on new work including prepartion of base with primer, putty, lippy etc complete in all respect. |
| 26 | Wiring of light point/ fan point/ exhaust fan point/ call bell point with1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexiblecopper conductor 1.1 kV gradeand 1.5 sq. mm nominal size FR PVC insulated unsheathedflexiblecopperearthconductor1.1kVgrade(IS:694) in recessed ISI marked MMS ( IS:9537 P - III ) virgin material PVC conduit & it\"sISI marked (IS:3419-1988) accessories, round tiles, 1.2 mm thickHot DippedGalvanizedModularBoxwithearthterminal,10AModular switch,Modular face plate with grid plate, 3 pin ceiling rose / Holder /3wayconnector,screws, makingconnections,testingetc.asrequired. Forspecificationofcopper Conductor, PhenolicLaminatedsheet\"s& Electrical/ Wiring accessories refer Chapter E - 04, E - 05 & E - 07 For additionaltechnicalparametersofproduct/workreferAnnexure\"A\" attached with this BSR |
| 27 | (a) S.P. (up to 3 mtr.) |
| 28 | (b) M.P. (up to 6 mtr.) |
| 29 | (c ) L.P. (up to 10 mtr.) |
| 30 | Wiring of 3/5 pin 6 amp. Light plug point with 1.5 sq. mm nominal size FRPVCinsulatedunsheathedflexiblecopperconductor1.1kVgrade and1.5sq.mmnominalsizeFRPVCinsulatedunsheathedflexible copperearthconductor1.1kVgrade(IS:694) in recessedISImarked MMS(IS:9537P -III )PVC conduit&it\"sISI marked(IS:3419- 1988)accessories, Hot Dipped GalvanizedModular box of 1.2 mm thick with earth terminal, 10 A modularswitch, 3/5 pin 6 A modular socket, Modular face plate with grid plate, screws, making connections, testing etc.asrequired. Forspecificationofcopper Conductor, Phenolic Laminated sheet\"s & Electrical/ Wiring accessories refer Chapter E - 04, E- 05 & E - 07 For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR : On board |
| 31 | S&F following sizes (dia.) of ISI marked virgin material MMS ( IS:9537 P - III)PVCconduitalongwith ISImarked(IS:3419-1988)accessoriesas required in recess including cuttingthewall,coveringconduitand making good the same as required. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR : 25 mm |
| 32 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductorasperPWDspecificationforelectricalWorkswithISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should bemadefrom 99.90%puritycopper,class5strandinginacc.to IS:8130/IEC 60228 forlower watt loss , oxygen free for less chances of oxidization,insulationPVCtypeA/C/D,flameretardantasperIS 10810-53,betteramperageratingasperIS:3961part5, inexisting surfaceorrecessedPVC/MS conduit/casingcapping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required.OEMMusthaveitsowninhouseNABLlabsetupforall testingfacilitiesforwires.Foradditionaltechnicalparametersof product / work refer Annexure \"A\" attached with this BSR |
| 33 | (a) 2 x 1.5 sq.mm |
| 34 | (b) 2 x 2.5 sq. mm + 1x1.5sqmm |
| 35 | © 2 x 4.0 sq. mm + 1 x 2.5 sq. mm |
| 36 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of loadand siterequirement)4KVimpulsewithstandvoltage,ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 asperIEC, minimumphaseterminationcapacityof35sq.mm., conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000upto20Aratingand10,000upto63A,5000for80A& above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.Single pole MCB (With B/C curve tripping Characteristics)6 A to 32 A rating |
| 37 | Providing & Fixing of 240/415 V AC MCB with positive isolation of 10 kA breaking capacity (B/ C/D tripping characteristic as per type of loadand siterequirement)4KVimpulsewithstandvoltage,ISI marked IS 8828(1996) / conforming to IEC 60898-1 2002, IEC 60947- 2, low watt losses, trip free mechanisum , energy limiting ofclass 3 asperIEC, minimumphaseterminationcapacityof35sq.mm., conductor line load reversibility , IP 20 contact protection and fitted inexisting distribution board/sheets, minimum electrical operation 20,000upto20Aratingand10,000upto63A,5000for80A& above ratingincluding making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.Double pole MCB(With B/C curve tripping Characteristics)6 A to 32 A rating |
| 38 | Providing&Fixingof240/415Visolator ISImarked IS:13947-III/conforming to IEC 60947-3, suitable for AC22A utilization category, 4KVimpulse withstandvoltage,truecontact indication, Redcolourdolly/levershallhavesinglemouldcoveringoverall polesforoperation,twopositiondinrailmounting, minimum phase termination capacity of 35sq.mm.IP 20contact protection andfittedinexistingdistributionboard/sheet includingmaking connections, testing etc. as required. OEM shall have submitNABL/ CPRI / ERDA accrediated lab type test reports& All as per pre approved by Engineer in charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR. Four pole Isolator, 80 A/ 100 A rating |
| 39 | Providing & Fixing of Recessed/surface mounting heavy duty horizontaltypeDoubleDoor(Metal/Glazed)Distributionboard with Metal end box made out from Galvanized steel / CRCA sheet notlessthen1.2mmthick conformingtoIS-8623-1&3/ IEC 61439- 1 & 3, powder painted completewith reversibledoor (for double door DB only )100 amp.insulated copper bus bar/shorting link , copper neutral link, copper earth link , color coded interconnectingwireset ofsuitableratinganddinbar,masking sheet,making internal DBterminations with copper lugs, Ferrules, detachable gland plate, including making connections, testing etc. as required. OEM shall have submitNABL / CPRI / ERDA accrediated labtypetestreports &AllasperpreapprovedbyEngineerin charge. For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR.Metal door (Three phase) IK-09 and IP-43with Metal end box, 6 Way |
| 40 | Providing & Fixing of IP20 SMD Mid Power LED batten type integrated light fixture made fromPowdercoatedExtrudedaluminium housingwithinbuiltdriver ,Systemlumen efficacy ≥ 110 lm/Watt output, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, CRI >80 , life time of minimum50000 Burning Hours with,70%ofintialLumenmaintanedtilllifeends ,CCT3000°K/4000°K /5700°K /6000°K/6500°K (As per ANSI Bin) , Maximum power consumption should not more than the specified rating and Fixture shall be ofBIS standard andtrade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. OEM must have its own in house NABL lab setup for all testing facilities for LED fixtures. (LM79 & LM80)certificate / ReportfromOEMshallbesubmitted. All as perpreapprovedby Engineerincharge. For additional technical parametersofproducts/ work, refer Annexure \"A\" attached with this BSR : 1170mm(+/-10%) LED batten with min. lumen output 2200 lm |
| 41 | Supplying and fixing of power plug point with Modular accessories as per PWD specification for electrical Works, on hot dipped galvanized modular boxof1.2mmthickwithearthingterminal/connectoronsurfaceorin recessed with suitable size of modular face place with grid plate and cover plate including cost ofISI marked modular 16 amp. Switch (IS :3854) and 6/16amp.socketoutlet(IS:1293)makingconnection,testing,etc.as required.Forspecificationof WiringaccessoriesreferChapter E-07 related item & For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR |
| 42 | P & F paper phenolic resin bondedlaminates confirming to IS : 2036 - 1995 for boxes/ frames including making holes for switches etc, with brassscrews,washers/zincplated nutandboltsasrequired.For additional technical parameters of product / work refer Annexure \"A\" attached with this BSR : 6.4 mm thick |