Repair Replacement And Day To Day Maintenance Of Lt Ug Cable Overhead Line Panel Boards Feeder Pillar Junction Boxes And Allied Works At Technical Area Af Station Jammu And Kaluchak Under Ge Af Jammuu - 1 M & L in replacement of out door aluminuam bus bar chamber feeder box of cap 300 Amp , 3 phase, 4 wire, 415 Volts with porcelain insulator weather and vermin proof with IP 54 protection, made out of 3.15 mm CRCA Sheet duly painted with two coats of synthetic enameld paint over a red oxide primer type ,both side openable,from front side & back having, locking arrangement on both sides,mounted over 50x50x6 mm angle iron stand at the bottom of height not less than 45 cm above ground level and not less than 30 cm in ground / floor mounted duly grouted in PCC 1:3:6 type C1 (using 20mm graded stone aggregate)factory made duly powder coated including taking out of old U/S paneland MCCB 200Amp 25KA four pole x 01 Nos as a Incomer all as directed by Engr-In-Charge. 2 S&Fin replacement of digital Amp meter in existing LT Panel 0 to 300Amp/500Amp with suitable CT and selector switch complete - 01 Set complete all as specified and directed. 3 S&Fin replacement of digital volt meter in existing LT Panel0 to 500V withsuitable selector switch complete all as specified and directed. 4 S&Fin replacement of LED type RYB indicator lamp in existing LT Panelcomplete all as specified and directed. 5 S&F single core PVC insulated unshesthed cable copper conductor of size 10 sqmm multistranded for panel/UPS wiring complete all as specified and directed. 6 S&F single core PVC insulated unshesthed cable copper conductor of size 16 sqmm multistranded for panel wiring complete all as specified and directed. 7 S&FSub main wiring with two single core PVC insulated unshesthed cable copper conductor(FRLS-H) of size 2.5 sqmm multistrandedand one run of 2.5 sqmm PVC insulated unsheathed copper conductor(FRLSH) as earth continuty conductor drawing in and including non-metalic PVC rigid conduit 25mm dia ISI marked with all conduit accessories concealed in wall, cutting of chases in walls, floors, ceilings, beams etc and making good the disturbed surfaces as directed including taking down old unservicable wiring complete all as specified and directed. (Two run of single core cable and one run of earthing cableand one run of PVC conduit shall be measured as one length.) 8 S&Fin replacement capacity luminaires 45 watt LED >5700Kwith driver of new street light/security light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. 9 All as per srl item No 8 here-in-before butCapacity 25watt LED 10 M&L for point wiring with 2.5 sqmm (Nominal area ) 1100 Volt PVC Insulated , FRLS unsheathed and multi strandedcopper conductor cable in and including new PVC Concealed conduit 20mm dia 1.5mm thick for one security light controlled by one 15A switch (including cutting chases and making good the distributed surfaces) and fixing new 3mm thick plastic laminated sheet top cover, sheet screws and PVC boxes after removing old unserviceable plastic laminated sheeet and PVC boxes included 2.5 Sqmm stranded copper conductor with green PVC Insulation earth contunity conductor connected to common earth dolly etc . complete all as specified and directed for the following :- Note : The cost ofPVC boxes and PVC sheet is included in the quoted rate) 11 S&F switch piano 16 Amps type one way 230 volts AC complete all as specified and as directed 12 S&Fin replacementceiling rose 65X50 mm two to three terminals complete all as specified. 13 S&Fstreet light bracket made out of GI pipe 40/32 mm suitable for 25/45watt LED Street light, medium grade 1.2 mtr long made to shape with fixing clamps of MS flat 40x6mm nut bolts etc for security/street light all as specified and directed 14 S&Ffor earthing complete with galvanized iron earth plate electrode 600x600 x6.0mm thick burried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of earth plate not less than 1.5mtr below normal ground level, connected to GI strip of size 32X6mm as earthing lead by means of nuts, bolts, check nuts and washersof galvanized iron or steel all as shown on Electrical PlateNo 3 of SSR Part-I 2009, connected to earthingtest point all as specified or indicated including testing on completion. The quoted unit rate shall include the following elements as given below :-(a) Earth electrode as mentioned above (b) Main earthing lead of 32X6 mm GI strip from earth electrode to test point up to 7.5 mtrs. (c) Connecting earthing leadand electrodeall as specified and testing complete. (d) Adequate quantity of charcoal and salt(e) GI protection pipe of 40 mm dia lightgrade of length not less than5.00 mtrs. (f) Necessary excavation, earth work and PCCpit , angle iron 40x40x6mm frame including RCC cover. 15 All as per Srl Item No 14.00but earth lead galvanised iron wire of 4mm dia connected by means of GI nuts, bolts and washers, 15mm bore light grade GI protection pipe 16 M&Lfor repairing existing LT Panel doors of front , back and internal sheets complete with new locking arrangement complete all as specified and directed. Note:Any part/spare found defectivesuch as packing, nuts bolts,hinges & (welding machine works) etc shall be repaired/replacedwhich cost shall be deemed to be included in the unit rate quoted for this item. 17 M&Lfor preparing old painted surface of panel board by cleaning removing of old paint by scratching with wire brush / sand paper etc and including denting of broken / rusted surface and applied two coat of synthetic surface enamel paint by spray painting outside surface of panel as existing colour of panel all as specified and directed. 18 Exacavation for cables loops near the poles LT Panels/transformers, cutting the damages/burnt parts of cable and reconnecting its positions complete with thimbles, nut bolts, sleeves all as specified and directed by Engineer-in-Charge. 19 Taking out carefully manually by excavation of existing LT/HT cable with loops and relaying with DWC pipe/brick the same after repair of cutting the damages / burnt parts of cable and reconnecting its into originalpositions complete with cable joints all as specified and directed by Engineer-in-Charge.Note:-(i)HT/LT Cable Joint & DWC Pipe/Brick will bemeasured and paid sepearetly. (ii) Unit rate shall be included in excavation and returning filling. (iii) Handling of UG cable to working site as ordered shall be carried out by the firm and rate for the same shall deem to be included in the unit rate. 20 Supply and erectsteel tubular swaged poles complete with cast iron base plate, final taper plug, bolts nuts & screws as specified type 410 SP-31 ( 9 mtr long) erecting in position all as specified and as directed by Engr-in-ChargeNote: (i) Excavation Earth work and foundation will be measured and paid seperately under relevent items. 21 M & L in replacement cross arms bracings supports clamps and back plates fabricated from structural steel sections including nut bolts washers welding bending cold and hot drilling holes for bolts in any shape or size as indicate or directed and inclusive of one primer coat one under coat and one finishing coat of paint. 22 S & Fin replacement straight through joint heat shinkablesuitable for3 core 11000 volts XLPEUGcable of size 95 Sq mm to 120 Sq mm complete all as specified and directed. 23 S & Fin replacement straight through joint heat shinkablesuitable for3 core 11000 volts XLPE UGcable of size 150 Sq mm to 240 Sq mm complete all as specified and directed. 24 S & Fin replacement End termination joint heat shrinkable of any size suitable for3 core 11000 volts XLPEUGcable of size 95 Sq mm to 120 Sq mm complete all as specified and directed. 25 S & Fin replacement End termination joint heat shrinkable of any size suitable for3 core 11000 volts XLPEUGcable of size 150 Sq mm to 240 Sq mm complete all as specified and directed. 26 Supply laying & testing in replcementof cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cable (Heavy duty_)LT 1100 voltgrade with stranded aluminium conductor of size 185 sqmm 3.5 core complete all as specified and directed. 27 All as per srl item No 26 here-in-before but of size 120 Sqmm 3.5 core. 28 All as per srl item No 26 here-in-before but of size 95 Sqmm 3.5 core. 29 All as per srl item No 26 here-in-before but of size 70 Sqmm 3.5 core. 30 All as per srl item No 26 here-in-before but of size 50 Sqmm 3.5 core. 31 All as per srl item No 26 here-in-before but of size 35 Sqmm 3.5 core. 32 All as per srl item No 26 here-in-before butsize 25 sq mm, 3.5 core. 33 All as per srl item No 26 here-in-before butsize 16 sq mm, 4 core. 34 All as per srl item No 26 here-in-before butsize 10 sq mm, 4 core. 35 Supply,laying & fixing in replacement double wall corrugated (DWC) pipes made of high density polythyline (HDPE) with all accessories i.e. all type of joints,Sockets,Elbows,bends and End caps etc.. allas specified and directed by Engr in Charge ofsize 50mm outer dia and 38mm inner dia 36 Ditto all as per items No 35 but of size 77mm outer dia and 63mm inner dia 37 Ditto all as per items No 35 but of size 90mm outer dia and 76mm inner dia 38 Ditto all as per items No 35 but of size 145mm outer dia and 126mm inner dia 39 S&F in replacement heavy duty aluminium thimbleof size 185 to 240 sqmm complete all as specified 40 S&F in replacement heavy duty aluminium thimble of size 300 to 400 sqmm complete all as specified 41 S&F in replacement heavy duty aluminium thimble of size 50 to 120sqmm complete all as specified 42 S&Fin replacement outdoor type Tiranga LED Rope light suitable for 9/11 mtr electric PCC/SteelPole decorative, Operting Voltage 140-270 Volts 240V AC Supply 50Hz supply connection from down side Jn box including driver and two run of 1.5 sqmm single core unarmoured wire from Junction boxcomplete all as specified and directed by Engr-in-Charge. 43 S&F in replacement 95 sqmm 11000V single core aluminium cable heavy duty insulated cablefrom top disc insulator to GOD and disc to disc in any lenth with complete nuts & thimbles all as required at site. 44 M&Lfor cleaning away all grass vegetation, scapling shrubs bushes under grouth roots and trees not exceding 30 cm grith and removing rubbish upto distance of 50 mtr out the periphery of area under cleaness complete all as specified and directed. 45 Supply and spraying anti vegetation chemical liquid of 1ltrs bottle mixed with water as per direction of Engr in charge .Make: Round Off 46 Supply and spraying in sub stn bldganti termite liquid of 1ltrs bottleas per direction of Engr in charge . 47 Taking out existing gravels/hardcore material from the bottom of substn/equipment completely for cleaning and spraying of anti grass chemical and screnning the hardcore material and refill the same at places complete all as specified and directed by Engr in charge. Note:- Anti Grass chemical and loose filling of aggregate for topping upwill be measured andpaid separetly respective item of BOQ. 48 Material & labour for providing 20mm broken stone aggregate including spreading and levelling complete all as specified and directed. 49 S&Fin replacement of lightening arrestor metal oxide type gap less hreavy duty single polesuitable forrated systemvoltage12 KV and working rated 9 KV normal discharge. 50 M&L for testing of faulty LT cable by using LTvoltage fault locating machine and finding the fault and to be repaired the same including all T&P as required on site complete all as directed. Note :- (a) Each job includes finding out the location of each fault in LT feeder. (b) Necessary excavation,returning filling and removal deemed included in this job.(c) LT straightJointandadditional LT cable if required it will be measured and paid separetlyunder respective item of this BOQ. 51 M&Lstraight through joint heats shinkable suitable forupto 50 sqmm LT3.5 core 1100 volts XLPE cable type complete all as specified and directed. 52 M&Lstraight through joint heats shinkable suitable for70 sqmm to120 sqmm LT3.5 core 1100 volts XLPE cable type complete all as specified and directed. 53 Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth and getting out in any type ofsoil for laying of LT UG cablescomplete. Note:- The Ratequoted deemed to including cutting and removal of PSP Sheets wherever occured during excavation and the same shall be staged at desired location as directed at site 54 Returning, filling in,including spreading levelling, watering and well ramming in layers not exceeding 25 cm thickin hard dense soil 55 Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point 56 S&Fin replacement ofmale and female contacts ofgang operative switchmade out of brass and rated capacity 200 amps ,make matching withthe existing switchcomplete all as specified and directed . 57 S&F in replacement of copper ribbon suitable for 200 amps rated apacity gang operative switch, 45 CM long complete all as specified and directed . 58 M&Lfor PCC 1:4:8 type D-2 using 40mm graded broken stone aggregate as in mass concrete in foundation of poles complete all as soecified. 59 M&Lfor PCC 1:3:6 type C-1using 20mm graded broken stone aggregate as in mass concrete in foundation of stays complete all as soecified. 60 S&F in replacementISI mark aluminiumthimblessuitable for under ground LTcables of sizes 16/25 sqmm 61 All as per srl item No 60here-in-before but of size 35/50 Sqmm 62 All as per srl item No60 here-in-before but of size 70/95 Sqmm 63 Supply and laying GI steel tubing, 100/80mm bore, light grade with all fittings, laid in trenches / under roads / along pole / wallfor protection ofCable / GI wire / GI strip etc complete all as specified and directed. 64 Labour for drilling hole under the road with the help of drilling machine without damaging the road horizontally for road crossing GI tubing of any size for cable protection complete all as specified and directed. 65 M&Lin replacement of LT fire resistant PVC self adhesive electrical insulaiontape high quality size minimum 18 mtr long x 1.8 CM width complete. 66 S&Fcapacity luminaires 120 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. 67 S&Fcapacity luminaires 150 watt LED >5700Kwith suitable bracket and nut bolt of new Flood light IP 66,Operating Voltage 140-270 Volts, PF (0.90),LED driver current > 850 mA,external Surge Voltage Protection,toughned class,indl LED with secondary lens incl making electric connection using two run of 1.5 sqmm single core unarmoured wire min length 1.5mtrcomplete all as specified and directed by Engr-in-Charge. 68 M&Lin replacement offire resistant PVC double side self adhesive compound tape for water proof electrical insulaion high quality size minimum width 9 inch complete all as specified. 69 S&F single core PVC insulated unshesthed cable copper conductor of size 2.5 sqmm multistranded drawing innon-metalic PVC rigid conduit complete all as specified and directed. (Note;- PVC Conduit will be Measureand paid seperatly as relevent item.) 70 S&FRigid non-metallic PVC conduit 25mm dia (Heavy duty)in concealed exclusive of boxes (junction/terminal) but inclusive of all tees, bends,elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. including taking out old conduit complete all as specified and directed. 71 S&F MCB SPN 40Amps C Curve 25 KA with Sheet metal encloser, complete all as specified and directed. 72 S&F MCB Single Pole Neutral16/25Amps C Curve25 KA with Sheet metal encloser, complete all as specified and directed. 73 Brick work using old size bricks, straight or curved on plan exceeding 6.00 metre mean radius built in cement mortar (1:6), including dismantling of UNSV brick work 74 Rendering 10 mm thickon fair faces of brick work or concrete surfaces, finished even and smoothon walls in cement mortar (1:6) 75 Four core 2.5 Sqmm PVC Copper cable with an inner sheathing of PVC tape and over all PVC Sheathed insulatedmulti stranded conductor 1100 volts grade 76 Thermoplastic polycarbonate cable junction boxhinged door type of size 200x160x 98 mm for 3 Phase and Nutralincoming cable, 77 LED Post top light45W 5700K made in die cast aluminium bottom housing and spun aluminium top reflector 78 LED Gardenlight9 W 5700K made in die cast aluminium alloy spigot and optical grade PMMA diffuser 79 LED Road signal light(Red/Yellow/Green) made in die cast aluminium alloyand IP66 protection 80 S & F cable route indicator made out of 45 x 45 x 5 mm angle iron, 80 mm long embedded in PCC block of suitable size with moulded lettter HT CABLE or LT CABLEsuitably incribed on CI circular plate 8 mm thick 100 dia complete incl neccessary PCC 1:3:6, type C-2 (using 40 mm graded aggrregate)block of suitable size and neccessary earth work and excavation all as specified and directed. 81 M&Lfor road cutting, including excavation, returning filling in, spreading, leveling, well ramming in layers, soiling with broken boudders/stones, WBM 7.5 cm thick coarse aggregate received from dismentling the existing road, premix, carpeting 25 mm thick using ready mix patch mate material, rolled and compacted for road patch repair work complete all as specified and directed. 82 Dismantling of interlocking cement concrete (any thickness/size), on floor fixed in cement mortar in single layer complete all as specifed and directed. 83 M & L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS- 15658-2006 of 60mm thickness , M-35 grade, with grey cement and pigment. Complete all as specified and directed. 84 All as per srl item No 83 above but except interlocking cement concrete tiles, (Any thickness/size) (old interlocking tiles obtained from srl items No 30, Complete all as specified and directed. 85 M&L 25 mm thick sand fillimg under floor/interlocking tiles etc Complete all as specified and directed. 86 Demolition of cement concrete in ground floors and paving not exceeding 15cm thickness (below or above ground level) and disposing the rubbish to a distance exceeding 87 S&F PVC insulated sheathed service wiretwin core 04 Sqmm aluminium multi stranded conductor 1100 volts grade incl taking down old unserviceable one. 88 S&F PVC insulated sheathed service wiretwin core 06 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. 89 S&F PVC insulated sheathed service wiretwin core 10 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. 90 S&F PVC insulated sheathed service wiretwin core 16 Sqmm aluminium multistranded conductor 1100 volts grade incl taking down old unserviceable one. 91 Preparation of old painted surface of 9 Mtr. steel tubular poles above the top of PCC coping.Painting of pole from top of coping to a height of 1.5mtr with two coats of synthetic enamel paint in white and sky blue alternate strip and painting the rest portion of pole of (approx length 7 mtr)including painting of cross arms/clamps etc complete with two coats of synthetic enamel aluminium paintand to the entiresatisfaction of Engineer-in-Charge complete all as specified and directed 92 S&FLT Cable End termination joining kitheat shrinkabale complete with jointing materials suitable for LT Armoured cableof size 10 to 35 Sqmm all as directed Make 3M /Denson / M-Seal 93 S&FLT Cable End Termination joining kitheat shrinkabale complete with jointing materials suitable for LT Armoured cable 3.5 coreof size 50 to 95 Sqmm all as directed Make 3M /Denson / M-Seal 94 M&Lfor earth continuity conductor or main earthing lead using 4 mm dia galvanised iron or steel wire fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required including taking down old wirecomplete all as specified and directed by Engineer-in-Charge. 95 M&Lfor earth continuity conductor or main earthing lead using 25 x 4mm galvanised steel strip fixed to wall on batten or recess or chases or burried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation, etc. as required including porcelain insulator saddle at the spacing nort exceeding 400mm including taking down old strip complete all as specified and directed by Engineer-in-Charge. 96 S&Fsolarstreet light luminaire efficacy of 120 lumen/watt and system wattage of 30 watthaving compact and fully integrated design with intelligent features includes a built in solar Panel, lithium Ferro phosphate Battery, charge Controller and Motion sensor including all fixing accessories for existing pole complete all as specified anddireced by Engr in Charge. 97 S&Fin replacement of automatic monoblock pressure/booster pump size 25mm x 25mm, tech motor S1 class B 230 Volt 500 HZ, RPM 2800, 10 MF, input power 650 watt with pressure tank of cap 19 ltrs PS max pressure bar 10 PT test pressure bar 14 with complete accessories and fitting complete all as specified and directed. 98 S&Fin replacement of micro-controller based automatic mains failure controller for on/Off power command for automatic shifting supply for capacity of 160 to 250 KVA DG including wiring and commissioning complete all as specified and directed by Engineer-in-Charge. 99 S&F in replacement of LEDbulb 9 watt,(6500K) Screw/ pin type lumino for normal batten holder/pendant holder complete all as specified and as directed. 100 S&Fin replacement ofMCCB 630Amps 4 pole 50 KAwith adjustablethermal and fixed magnetic setting, complete all as specified and directed. 101 S&Fin replacement ofMCCB 350Amps 4 pole 36 KAwith adjustablethermal and fixed magnetic setting, complete all as specified and directed. 102 S&Fin replacement of MCCB 250Amps 4 pole 35 KA with Sheet metal encloser withadjustablethermal and fixed magnetic setting, complete all as specified and directed. 103 S&F in replacement of MCCB 160Amps 4 pole 36 KA with Sheet metal encloser withadjustablethermal and fixed magnetic setting,complete all as specified and directed. 104 S&Fin replacement ofMCCB 160Amps 4 pole 25 KA adjustablethermal and fixed magnetic setting, complete all as specified and directed. 105 S&Fin replacement ofMCCB 100Amps 4 pole 25 KA with Sheet metal encloser withadjustablethermal and fixed magnetic setting,complete all as specified and directed. 106 S&F in replacement of MCCB 100Amps 4 pole 25 KAadjustablethermal and fixed magnetic setting,complete all as specified and directed. 107 S&F in replacement of on load change over630 Amp 4 pole complete withwith Sheet metal encloser incl operating handle and dismantling/connection ofexisting cables complete as specified and directed by Engineer-in-Charge. 108 S&F in replacement of on load change over315 Amp 4 pole complete withwith Sheet metal encloser incl operating handle and dismantling/connection ofexisting cables complete as specified and directed by Engineer-in-Charge. 109 S&Fin replacement CT unit 100/50/5A, 15 VA50Hz suitable for 11KV VCB Make Schenider/Kirloskar/CG 110 Supply, Installation and Fixing LT 300A Bus Bar Feeder Pillar shall be OEM made out of GRP, Glass-fiber reinforced polyester SMC as per EN 14598-1-UP FR2 material with Protection class IP 54in accordance with IEC 60529 and Color code RAL 7032 completely dyedin mass and box shall be made out of insulating, slow-burning and self-extinguishing composite (polyester + glass fiber) characterized with resistance to atmospheric agents (UV). Protection class II (EN 61140) when correctly installed on the base and Panel internal sizeshould be not less than 590mm x 800mm x 220 mm. GRP material shall be Anti-corrosive suitable for saline atmosphere and have ambient temperatures of -50°C up to +120°C, Flammability HB 40 a, b (EN 60695-11-10),V-1. Glow wire tested at 960°C/ 3 mm as per EN 60695-2-12. The dimensional stability under heat is more than 200 °C as per ISO 75 – 2 method A . The enclosure is Halogen-free, resistant to termites. GRP cabinet should withstand minimum Di-Electric strength of 130KV/Cm as per IEC 60243-1. The Panel box shall have shall be equipped with GRP handle lock with Manual outer locking and the provision to insert various type of locking cylinders provided to avoid unauthorized access. RoHS Directive (EU) 2015/863 (extension to directive 2011/65/EU),REACH Regulation (EC) no. 1907/2006. The Feeder Pillar with MCCB 200A FP 36KA - 1 No. Panel mounted on suitable MS Angle Stand and TPN Aluminium Bus-bar with Heat Shrinkable Sleeves of capacity 300 Amp,wiring of Panel with suitable size of Copper Conductor Cable, Thimbles, etc. having size of the Panel suitable for fixing the Items/Materials mentioned at here-in-below, complete all as specified and as directed . 111 Notes:-1. The minor items such as Lugs, Nuts and Bolts, Washers, Top Insulators, Sleeves, provision of extra holes in bus bar etc. shall be provided by the Contractor as directed. The Quoted Rate shall be deemed to include the cost of the same and nothing extra shall be admissible from the department on this account what-so-ever.2. All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694.3. The Panel drawings shall be got approved from GE before placing the Order.4. The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. 112 Supplying, Installing, Testing and Commissioning Outdoor type Cubical Feeder Pillar Boxplatform mounted factory made totally enclosed dust and vermin proof (protection class IP-54) single shutter front opening with locking arrangement complete made of angle iron 50 mm x 50 mm x 6 mm thick frame work, outer shell made out of 3.15 mm thick MS sheet and inner shell made out of 2.0mm thick MS sheet duly painted with powder coated paint over a coat of red oxide primer over outside and inside complete.The panel board shall be equipped with the following accessories :-(a) Aluminium Busbar 400 Amps Capacity TPN colour coded with heat shrinkable sleeves - 01 Set(b) Incoming MCCB 315 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 25 KA,with double break contacts with spreader and phase barrier -01 Nos(c) Outgoing MCCB 160 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 16 KA,with double break contacts with spreader and phase barrier -01 Nos(d) Outgoing MCCB 100 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 16 KA,with double break contacts with spreader and phase barrier -01 Nos(e) Outgoing MCCB 63 Amps FP 415 Volts AC with adjustable thermal magnetic trip release 16 KA,with double break contacts with spreader and phase barrier -01 Nos(d) Indicator Lamp RYB - 01 Set of Three(e) Digital Voltmeter Square Flush Pattern 0-500 V of size 96 Sqmm with Selector Switch -01 Nos(f) Digital Ammeter Square Flush Pattern 0-200 A of size 96 Sqmm with Selector Switch and CT Coils -01 Nos. 113 SCHEDULE A PART-II (Schedule of credit) Credit amount of Rs (Refer schedule of credit) for retrieved material mentioned in Sch A Part-II of Tender documents in PDF form will be deducted offline during acceptance of tender of lowest bidder.