Tender For Provision Of Solid Waste Mgt Plant Under Ge I Gos- 1 Supply installation, commissioning & testing Kill waste machine 200 Kg/Hr fuel free Solid Waste disposal System with pollution control device complete with 97.3% efficiency with non corrosive carbon steel structure for kill Machine using tubular pole & trusses with ERW or butt welded tubes covering with galvalume aluminum Ninc coating Gl based plain steel sheets and cement concrete platform as per OEM manufacturer recommendations complete with control panel with suitable size cap: MCCB, MCB relay contactor as per recommendation. The machine shall have following specifications :- 2 Material Non-corrosive mild carbon steel of IS2062-Gde-B category cylindrical chamber as specified by BIS. 3 Pollution control device Multi Level Wet scrubber with activated charcoal baffle filter, emission testing port. 4 Chimney made up of stainless steel class 12, GR 304 effective height from ground level shall be minimum 13 Mtrs, thickness 4mm including all supporting structures stay wire suitable to withstand local wind pressure complete all as directed :- 5 Additional neck reinforcement for storm proof. 6 Necessary thermal insulation of (Cement, concrete, fire brick, Glass wool Aluminum sheet). 7 Body parts as following:(a) Upper Cone(b) Cylindrical chamber(c) Lower Cone(d) Loading door.(e) Inspection door(f) Ash door 8 Air rotating technology (ARI) -6mm vide non corrosive mild steel carbon steel of IS-2062 Gde B category tower with ERW seamless pipe size 50mm dia of wall thickness 6mm (Schedule-40). 9 Air chamber with ERW seamless pipe size 250mm dia of wall thick 6mm thick. 10 Air inlet pipe size 50mm. 11 Additional air tube (Steel tube 2x1 wall thickness 1.6mm secondary burning chamber pipe size 2 thickness 4mm. 12 Generalrequirements(i) Foundation/Plinth/Base: shall be provided as per manufactures recommendations, however minimum 0.5m space should be available all around the set and height of plinth shall not be less than 0.5m(ii)Tool kit, operation and maintenance catalogue, spare aprt list, overhauling manuals, guarantee card etc shall be provided as per manufacturer standard practices.(iii)The electrical works including electrical LT panel, internal wiring of the LT Panel, suitable size copper wires from panel to solid waste Fuel free solid Waste disposal system as recommended by OEM to operate the Solid waste Solid waste disposal system of cap 200 Kg/Hr to make system operational is deemed to be included in the rate quoted.(iv) All Electrical works shall be carried out as per relevant BIS/IS equivalent standard norms only and also in accordance with the latest edition of theIndian Lectricity Act/rules formed there under and as amended from time to time.(v)Any other works (mechanical, electrical & Civil) connected to installation, testing & functinal requirement of Solid waste disposal system of cap 200Kg/Hr all as mentioned above and which is not mentioned or included in this Schedule but required at site necessary shall be carried out by the contractor and quoted rate shall deemed to include for the same 13 M&L for boring / drilling bore of dia suitable for 200/250mm dia HDPE pipes by any suitable method (by DTH-cum-rotary or reverse rig method or hammering method) by reaming upto 300 mm dia to a depth of 60 mtrs in any type of soil including disposal of materials obtained (soils boulders etc ) from boring to a distance not exceeding 50 mtrs with & including collection of logical samples ( drilling / cutting ) & to maintain drill time log book complete all as specifiedand directed 14 Development of borewell including flushing out tree routs, fine sand by air compressor of suitable capacity not less than 450 CFM at 150 PSI & over pumping (25% extra capacity pump) to make water free from turbidity till clear water is obtained from bore well complete all as specified and as directed (pumping for minimum 16 hours, the upper limit for duration of development shall be the time technically required to give results of development as per IS.. nothing extra shall be payable on account of increase in numbers of pumping hours actually required at site in excess of minimum period as above ) 15 M&L lowering casing pipe 200mm dia HDPE pipe of material grade PF-80, PN 10 (pressure rating 10 Kg per sqcm) DN 200, confirming to IS-4984 (1955) for protection of sides from falling during the process of drilling including required cutting, jointing etc complete all as specified and as directed 16 Supply & filling pea gravel in space between casing pipe & bore hole with & including river bed stone pebbles of size/ grading 5 to 8 mm dia including packing complete all as specified & directed 17 M&L for yield test for bore hole after completion of development of bore well by pumping of 16 hours to determine the safe pumping yield complete all as specified and as directed 18 S&F steel rope in submersible bore wells from motor to top edge of the bore well of size 6 mm dia for holding of submersible pump motor set complete all as specified and as directed 19 S&F bore cape of size 200/250 mm dia with MS clamp for holding of pump set and column pipe complete all as specified and as directed 20 S&F submersible cable weather proof with multistraded copper conductor 3 core of size 6 sqmm 1100 volts grade heavy duty including all accessories for connectingpumpto panel board, testing and commissioning complete all as specified and as directed 21 Supply and fixing submersible pump, electric driven 415 v,TP suitable for 200/250 mm bore well (Casing pipesize200/250mm)supply and install 3 HP, 40 mtr Head,105LPM, 38mm outlet (Model KS4C- Series Make :Kirloskar/CRI including lowering by manpower & mechanical complete all as specified and directed. 22 S&F gun metal NRV of size 50mm screwed both ends of the pipe complete all as specified and directed 23 S&F in repair of PP-R gate valves(brass inlet) as per requirement of size 63 mm OD complete all as specified and directed. Make : SFMC or equivalent in approved by E-in-C 24 S&F GI Pipe 50mm dia & 3 meter long (ISI Marked) class C heavy duty column pipe, with long screwed end, with 100 mm long GI socket heavy duty, fixed with spot welding complete all as specified 25 Supply , fabricate, erect, test and commission outdoor LT feeder pillar box totally enclosed weather and vermin proof CPRI approved suitably ventilated, 440 volts, 50 Hz AC supply, factory made, fully compatmentalised made out of 3.0 mm thick CRCA sheet steel for load bearing and 2.0 mm thick for non-load bearing portions, protection of enclosure IP-54 as per IS-2147 of 1962 complet with re-treatment and powder coating of approve colour including suitable angle iron/flat iron frame work/supports , excavation and earth work,PCC foundation etc, outdoor type cuibical type as required with and including the following , supplied fitted and connected internally complete all as specified and as directed 26 (a) 3Nos Al bus bar of 100 Amps and 01 No 50 Amps with PVC coloured heat shrikable type sleeves on non cracking resin type insulators with CTs digital type ammeter and volt meter with slector switches, set of LED type indicating lamps R Y B on incoming side. 27 (b) MCB TPN , 32 Amps 50 Hz415 volts with internal based release and raturing capacity 10KA-01 No 28 (c)Power contractor 32 Amp 3Phase along with ON/OFF push buttons& over load protection. 29 (d) Multi function mete 30 (g) Single phase preventer device 440 volts, 3 phase (Havells /Indo Asian /L&T) 31 (h) Analogue type adjustable cyclic timer(Havells /Indo Asian /L&T) 32 Supply, laying and testing PVC insulated, armoured heavy duty electric cable, screened PVC bedded, with aluminium conductor 1100 V grade, laid in trenches/ along poles, ducts or through sleeve including taking out existing unserviceable cable complete all as specified and directed for size 10 sqmm 4 core complete all as specified and directed. 33 S&F 3-layer PP-R polypropylene random copolymer concealed pipe SDR 7.4 (PN 16) UV stablised and antimicrobial fusion welded having thermal stability for hot & cold water supply including all PP-R plain & brass threaded polypropylene random fittings fixed complete to walls, ceilings, floors or in trenches etc of size 63 mm OD complete all as specified and directed. 34 All as per Item No. 16 above but of size 32 mm OD. 35 Excavation in trenches in soft/loose soil n.exc 1.5 mtr wide and n.exc 1.5 mtr depth and getting out for taking out / laying of cable complete all as specified and directed. 36 Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm thick complete all as specified and directed. 37 Removing surplus excavated material not exc 50 mtrs and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed. 38 Supply and providing sand cushioning with dry clean sand 15 cm below cable and 8 cm above the cable complete all as specified and directed. Note : Punned thickness shall be measured for the purpose of payments. 39 Supply and laying bricks common burnt clay flyash building bricks laid in trenches for LT cable protection with length of brick perpendicular to length of cable complete all as specified and directed. 40 S&F rotational moulded polythlene water storage tanks of capacity 2000ltr(cylindrical vertical with closed top) all as specified and directed. 41 Supply and Fix Monoblock pump set suitable for 240 V, singlephase system having capacity 1 HP.20Mtr head along with starter. 42 Supply and fixing in repairs modular switch 1 way,16Amps,1module,240V, ISI Marked and suitable for existing type as per site requirement andincluding removing old usnv items complete all as specified and directed.