Tender For Providing And Fixing 62.5 Kva Dg Set At Pump House Ward No. 08 Premnagar Anupgarh , Civil/Goods , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinth Level : 1:4:8 (1 Cement : 4 Fine/ Coarse Sand : 8 Graded Stone Aggregate 40 Mm Nominal Size). , Providing And Laying In Position Cement Concrete Of Specified Grade Excluding The Cost Of Centring And Shuttering - All Work Upto Plinth Level : 1:1½:3 (1 Cement : 1½ Fine/ Coarse Sand : 3 Graded Stone Aggregate 40 Mm Nominal Size). , Earth Filling With Available Surplus Soil Excavated From Foundations And Taken Only From Outside Of Building Plinth In Layers Not Exceeding 20Cm In Depth, Consolidating Each Deposited Layer Including Ramming And Watering And Consolidation With Lead Up To 50 M And Lift Upto 1.5 M. , Brick Work With Modular Fly Ash Lime Bricks (Falg Bricks) Conforming To Is:12894-2002, Class Designation 100 Average Compressive Strength In Super Structure Above Plinth Level Upto Two Stories In : Cement Mortar 1:6 (1 Cement : 6 Coarse Sand) (24.33.2) , Cement Plastering Including T&P, Scaffolding, Material And Complete Labour, Including Cost Of Water, Curing, Racking Of Joints Etc. With 12 Mm Cement Plaster Of Mix : Including Providing /Mixing Of Synthetic Fibers Compulsorily Complying With Is 16481:2022 Of 06 Mm/12 Mm Length To Be Mixed @ 0.25% By Weight Of Cement I.E. 125 Gms Per 50 Kg Cement Up To 900 Gms Per Cum Of Concrete/ Mortar 1:4 (1 Cement : 4 Fine/ Coarse Sand) E) (I) Accoustic Glass Wool Wall Thickness Should Not Be Less Then 40Mm And Not Less Then 20Mm Pu Foam Upto Rating 100 Kva. (Ii).Accoustic Glass Wool Wall Thickness Should Not Be Less Then 65Mm And Not Less Then 50Mm Pu Foam Upto Rating 250 Kva. (Iii)Accoustic Glass Wool Wall Thickness Should Not Be Less Then 100Mm For Rating Above 250 Kva. F) First Filling Of The Fuel Tank Shall Be Done By Contractor And The Prevailing Fuel Cost At That Time Shall Be Reimbursed To The Contactor By Department. G) Servicing Contract Of Dg Set From Oems Authorised Service Dealer As Per Oem Guidelines During The Dlp Period Shall Be Done By Contractor Including All Consumables, Actual Charges Shall Be Reimbursed To The Contractor By End User Department. H) Manufacturer / Oem Must Have Its Authorized Service Dealer In Rajasthan. Which Can Provide Service Within 6 Hours Of Compalint Registration. I) Dg Set Will Be Offered For Inspection And Testing At Manufacturers Works In Presence Of Departmental Engineers. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . , Sitc Of Radiator Cooled And Turbo Charged Silent Dg Set (As Per Latest Cpcb Emission Norms) Having Specifications As Per A, B, C, D, E, F,G,H & I A) 1500 Rpm Diesel Engine Conforming To Bs:649/5514 Of Suitable Bhp (Up To 82.5 Kva 6 Cylinder Or Below Required, 125 Kva & Above Ratings 6 Cylinder Or Above Required ) Capable Of Taking 10% Over Loading For One Hour After 12 Hours Of Continuous Operation., Dry Exhaust Mainfold With Hospital Grade Silencer And Catalytic Convertor(Isolated From Main Dg Chamber), Up To 3 M Exhaust Piping (With Lrb Insulation & Alum. Cladding ) As Required . B) Ac Brush Less Spdp Alternator Conform To Bs 5000 (Part 99) Or Is/Iec 60034-1. . Alternator Shall Be Self Regulated With Standard Alternator Protection( Over Voltage , Over Speed & Under Voltage, Under Speed Warning & Shutdown).Engine & Alternator Mounted On A Common Base Frame & Coupled Through A Flexible Coupling Or Close Coupled C) Cpcb / Arai Approved Standard Canopy With Weatherproof, Powdercoated Accoustic Enclosure For Dg Set For Sound Attenuation Fabricated From 1.6 Mm Crca Sheet Steel (Structure) With Sidewall Fabricated From 1.6 Mm Crca Sheet & Filled With Glasswool (96Kg/M3) / Foam. As Per Is8183 The Doors Of 28/40/50/85Mm Thick As Perrating And Fabricated From 1.6Mm Crca Sheet Packed With Accoustic Material, All Doors/Opening Are Sealed With Neoprene /Epdngaskets. The Dg Set Has Inbuilt / External In Fuel Tank To Run 6 To 8 Hrs As Per Oem Standard, With Protection And Tripping Of Dg Set Against Temperature Of More Than 50 Degree Centigrade. D) Electronic / Mechanical Governor, Manual & Electric Start ,Batteries With Battry Charger, Engine Instruments Panel,Avm Pads All Controls For Operation Of Dg Set Are From Outside The Enclosure With Dg Control Panel Having Microprocessor Based Genset Monitoring Like Running Hour, Rpm, Low Lube Oil Tripping & Control System, Panel Mounted Mccb/Acb Of Suitable Rating, Ammeter, Voltmeter, Pf Meter, Frequency Meter, Kwh Meter,Digital Fuel Display Meter, Ind.Lamps Etc. Mounted Inside Enclosure , Visible And Accessible From Outside. The Enclosure Should Be Suitable For Following Capacity Dg Sets And Alternator. Noise Level Shall Be Less Than 75 Db At A Distance Of 1 Mtrs. Duly Certified By Authorised Agency Etc. Complete In All Respect Of Following Capacity : E) (I) Accoustic Glass Wool Wall Thickness Should Not Be Less Then 40Mm And Not Less Then 20Mm Pu Foam Upto Rating 100 Kva. (Ii).Accoustic Glass Wool Wall Thickness Should Not Be Less Then 65Mm And Not Less Then 50Mm Pu Foam Upto Rating 250 Kva. (Iii)Accoustic Glass Wool Wall Thickness Should Not Be Less Then 100Mm For Rating Above 250 Kva. F) First Filling Of The Fuel Tank Shall Be Done By Contractor And The Prevailing Fuel Cost At That Time Shall Be Reimbursed To The Contactor By Department. G) Servicing Contract Of Dg Set From Oems Authorised Service Dealer As Per Oem Guidelines During The Dlp Period Shall Be Done By Contractor Including All Consumables, Actual Charges Shall Be Reimbursed To The Contractor By End User Department. H) Manufacturer / Oem Must Have Its Authorized Service Dealer In Rajasthan. Which Can Provide Service Within 6 Hours Of Compalint Registration. I) Dg Set Will Be Offered For Inspection And Testing At Manufacturers Works In Presence Of Departmental Engineers. All As Per Pre Approved By Engineer In-Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With This Bsr . (72.17.6) 62.5 Kva At 0.8 Pf 415V 50Hz 3-? , Providing & Laying P.V.C. / Xlpe Insulated & P.V.C. Sheathed Un-Arrmoured Aluminium Cable Confirming To Is:1554 P-I / Is :7098 P - I Of 1.1 Kv With H4- Grade Electrolytic Aluminium Conductor Confirming To Is 8130 Of Purity >99.6 %, Inner / Outer Sheath Confirming To Is:5831 In Existing Rcc / Hume / Stoneware / Pvc Pipe/ Open Duct/Cable Trench / Cable Tray (With Cable Tie) Including Testing Etc. As Required Of Following Size. Oem Must Have Its Own In House Nabl Accrediated Laboratory For Testing Procedure As Per Is:10810. For Additional Technical Parameters Of Product / Work Refer Annexure A Attached With This Bsr 70.0 Sq,Mm 3.5 Core (Group-1) , Plate Earthling As Per Is:3043 With Copper Earth Plate Of Size 600Mm X 600 Mm X 3.0Mm By Embodying 3 To 4 Mtr. Below The Ground Level With 25 Mm Dia. G.I. ‘B’ Class Watering Pipe Including All Accessories Like Nut, Bolts, Reducer, Nipple, Wire Meshed Funnel, And C.C. Finished Chamber Covered With Hinged Type With Locking Arrangement C.I. Cover, C.I Frame Of Size 300Mm X 300Mm Complete With Alternate Layers Of Salt And Coke/Charcoal, Testing Of Earth Resistance As Required. (42.37) , S & Laying Following Size ‘B’ Class G.I. Pipe Confirming To Is: 1239 P-1 (1990) With Accessories For Laying Earth Conductor/ Strip/ Cable In Ground/ Surface/ Recess As Required. 50 Mm Dia. (42.38.1)