| 1 | M&L for cleaning of all blockages of Nahni traps/floor traps/bottle traps, blockages of WC\"s, Rain water pipes, Rain water spouts at roof level, 100 mm dia CI pipes upto 1st manhole/GT in shafts, vertical CI soil / waste pipe stacks, CI Tee / door bends etc & cleaning ofdrain pipes 150 mm to 250 mminternal diaby rodding and manholes upto 3.0 metre in depth and removal of sludge / silt / liquid mud sand (in foul conditions) etc, out of MOD premises (at the location notified by the local Municipal Corporation / Cantt board) complete all as specified and directed by the Engineer-in-Charge to maintain internal & external sewage system in functional state at all the time by engaging / deploying adequate safaiwala (if required ) for IML, 1 CBPO AND 5 RAJPUT from 0900 hours to 1700 hoursatComplaint cell (AGE B/R-I) mentioned in the contracton daily basis, with manual / pressure cleaning pump and flexible rods and other necessary equipments (as per rules of public health), including digging required nos of pits for depositing sludge and furthure capping the pit with the 25 cm thick layer of soil, complete all as specified and as directed.Note :- 1 The Nos of person indicated in above items as assumed by the department, shall remain present at the complaint cell of AGE B/R-I (south). Contractor may have to deploy more manpower in the particular area anddeploy adequate sewage cleaning machine / equipments to clean the line andopen blockages. Rates quoted shall be deemed to have considered all such contingencies. 2.In case of non availability / absence of any of minimum required tradesmen, the recovery for the same shall be effected at double the minimum fair wages applicable for the relevant category or double the market rates whichever is higher, in addition to non payment of this item for the absence period proportionally.3. If necessiated by the Engr-in-charge / GE for work on Sunday /holidays, the contractor shall provide tradesmen with helpers.4. Proper records (date wise) of complaints received & rectified by the contractor and attendance register of trademen shall be maintained and shall be produced for verification at the time of payment of each RAR / Bill. |
| 2 | Taking down cement or cement lime plaster on bricks on stone walls etc incl racking out joints, heacking for key, scrubbing down with water complete all as specified and as directed. |
| 3 | M&L for 15 mm thick plaster ready mix plaster on brick / concrete surface of external walls, finished even and smooth without using extra cement complete all as specified and as directed. |
| 4 | Excavation in trenches not exceeding 1.5 m wide ¬exceeding 1.5 m in depth as in foundation, manholes etc. not exceeding 10 sqm on plan and getting out in soft/loose soil complete all as specified & as directed. |
| 5 | All as per srl item No 4.00 here-in-before but exceeding 1.5 m but not exceeding 3.0 m. |
| 6 | Demolition of brick work / stone boulder measonary built in cement mortar or cement lime mortar of any description and in any position complete all as specified and as directed. |
| 7 | M&L for Brick work with subclass ‘B’ bricks, built in cement mortar 1:4, straight or curved on plan, exceeding 6 m mean radius complete all as specified and as directed. |
| 8 | All as per srl item No. 6.00 here-in-before but except bricks. |
| 9 | M & L for half brick work with subclass ‘B’ bricks, straight or curved on plan to any radius inbuilt in cement mortar 1:4 complete all as specified and as directed. |
| 10 | M&Lfor reinforced cement concrete pipes 150 mm bore, class NP2, laid and jointed complete with collars drain pipes, laid in trenches and jointed in cement mortar (1:4) and tested including demolition and breaking up drain pipes 150 mm bore (salt glazed stoneware/ACC/RCC), set in cement mortar, including removal of waste material upto 500 m distance at the place notified, complete all as specified and as directed. |
| 11 | M&L for cement concrete bedto drain pipes 150 mm bore, in (1:3:6) type C-2(using 40mm graded stone aggregate) including packing under and haunching against sides ofpipes after they are laid andtested, complete all as specified and as directed. |
| 12 | M&Lfor reinforced cement concrete pipes 200 mm bore, class NP2, laid and jointed complete with collars drain pipes, laid in trenches and jointed in cement mortar (1:4) and tested including demolition and breaking up drain pipes 150 mm bore (salt glazed stoneware/ACC/RCC), set in cement mortar, including removal of waste material upto 500 m distance at the place notified, complete all as specified and as directed. |
| 13 | M&L for cement concrete bedto drain pipes 200 mm bore, in (1:3:6) type C-2(using 40mm graded stone aggregate) including packing under and haunching against sides ofpipes after they are laid andtested, complete all as specified and as directed. |
| 14 | Materials and labour 150 mm boreHDPE pipe as per IS-16098, ISI marked, laid in trenches and jointed, tested including laying complete with collars as per manufacturer instructions & including plain cement concrete (1:3:6) type C-2(using 40mm graded stone aggregate) as in bed to drain pipes 150 mm bore including packing under and haunching against sides ofpipes after they are laid andtested, and incluing demolition of old pipe and complete all as specified and as directed . |
| 15 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft /loose / hard soil complete all as specified and as directed. |
| 16 | Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed. |
| 17 | S & F in repair factory made ISI marked FRP manhole cover with commercial grade having loading capacity 5 tonne (single/double) with complete frame set any shape and size (not less than 70 mm thick) as per company specification, with suitable frame set in PCC type C-0 1:3:6 with 12.50 mm graded aggregate and holding down bolts provided with safe and anti-slippery surface, fire retardant, Anti Corrosive, suitable locking system, and enable clear opening with provision of easy lifting hooks, etc; with all necesarry fixing arrangements complete all as specified and as directed. |
| 18 | S & F in repair factory made ISI marked FRP Gully Trap cover with commercial grade having loading capacity 5 tonne of size 400 X 400 mm dia with suitable frame set in PCC type C-0 1:3:6 with 12.50 mm graded aggregate and holding down bolts provided with safe and anti-slippery surface, fire retardant, Anti Corrosive, suitable locking system, and enable clear opening with provision of easy lifting hooks, etc; with all necesarry fixing arrangements complete all as specified and as directed. |
| 19 | S & F in repair factory made ISI marked FRP manhole cover with commercial grade having loading capacity 5 tonne of size 450 X 900 mm with suitable frame set in PCC type C-0 1:3:6 with 12.50 mm graded aggregate and holding down bolts provided with safe and anti-slippery surface, fire retardant, Anti Corrosive, suitable locking system, and enable clear opening with provision of easy lifting hooks, etc; with all necesarry fixing arrangements complete all as specified and as directed. |
| 20 | S & F in repair factory made ISI masrked FRP manhole cover with commercial grade having loading capacity 5 tonne of size 600 X 600 mm / 600 mm dia with suitable frame set in PCC type C-0 1:3:6 with 12.50 mm graded aggregate and holding down bolts provided with safe and anti-slippery surface, fire retardant, Anti Corrosive, suitable locking system, and enable clear opening with provision of easy lifting hooks, etc; with all necesarry fixing arrangements complete all as specified and as directed. |
| 21 | Desilting / desludging /cleaning of drains (covered/uncovered) of sectional area upto 1.00 Sqm and removing all blockage from drains such as plastic pieces, soil etc and removing the materials out side of MoD land complete all as specified and as directed.Note :-1. The cover should be removed mechanically with due care and replace the same after cleaning the drain. 2. The rates are deemed to be included in the unit rates quoted. |
| 22 | S & F in repair, PVC (SWR) gully trap 125/110 mm, setting and jointing with solvent cement, shape as required, including dismantling and taking out of old GT and jointing with old connection and pipes complete all as specified and as directed. |
| 23 | M & L for extra for forming fair furnished drain or channels 30 cm inner girth in cement concrete using cement including forming moulds,mitred/stopped ends etc complete all as specified and as directed. |
| 24 | Add or deduct for each 25 mm girth or part thereof over or under 30 cm for srl item No 23.00 here-in-before. |
| 25 | Demolition of cement concrete (un reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and as directed. |
| 26 | M&L for PCC(1:4:8) type D-2 (using 40 mm graded crushed stone aggregate) as in foundation filling and mass concrete including necessary form work complete all as specified and as directed. |
| 27 | M&L plain cementconcrete (1:2:4)type B-1 (using 20mm graded stone aggregate) as in cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings, Plinth Protechtion, copings, kneelers, apex stones, bed plates,kerbs, post, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed & including use and waste of form work complete all as specified. |
| 28 | Cleaning ofsewage lines from 100 mm bore not exc 300 mm bore including manholes by super sucker machine with water jet pressure, the sucked wastage material will be collected in tanker and disposed off out of MoD land . All T&P will be provided by contractor including water for pressureto the entire satisfaction of Engineer-in-Charge and testing by pouring water from manhole to manhole complete all as specified and as directed.Note : A pucca bound register shall be maintained by contractor at site for showing the date and type of machine brought by the contractor with machine number, licence number etc and the total hours deployed at site. These details shall be got signed by JE, Engr-in-Charge and contractor which may be asked while claiming the payment of work done. |
| 29 | S & F in repair factory made ISI marked FRP manhole cover with commercial grade having loading capacity 5 tonne of size 300 X 300 mm dia with suitable frame set in PCC type C-0 1:3:6 with 12.50 mm graded aggregate and holding down bolts provided with safe and anti-slippery surface, fire retardant, Anti Corrosive, suitable locking system, and enable clear opening with provision of easy lifting hooks, etc; with all necesarry fixing arrangements complete all as specified and as directed. |
| 30 | M&L for 75 mm thick cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in sub base complete all as specified and as directed. |
| 31 | M &L for coloured chequered cement concrete tiles 30cm x 30cm x 25mm thick (glossy finished), set with white cement and pigments, jointed and pointed in neat cement slurry in floors, over and including 15 mm thick screed bed or bedding layer in cement mortar 1:4 including dismantling of old chequred tile complete all as specified and as directed. |
| 32 | M & L for60 mm thick factory made chamfered edge cement concrete coloured interlocking paver block of M-35 grade with approved colour (glossy finish), design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50 mm thick compacted bed of coarse sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver block as per required size and pattern, finishing and sweeping extra sand including dismantling of old interlocking paver block complete all as specified and as directed. |
| 33 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed. |
| 34 | M & L for rolled mild steel in plate girder or single stanchions, built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections complete all as specified. (Fe 410-W (Gde-E- 250) quality-A) complete all as specified and as directed. |
| 35 | M & L for framed work as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified. (Fe 410-W (Gde- E- 250) quality- A) complete all as specified and as directed. |
| 36 | M & L for mild steel framed work such as grills, Gratings, manholes covers, rungs etc with ends of bars shouldered or reverted , frame work of water tanks and similar work conforming to fe 290 Gde-E-165 complete all as specified and as directed. . |
| 37 | M & L for mild steel hand rails,for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed. |
| 38 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 39 | M&L for 3-4 mm thick Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.including dismantling of old sheet complete all as specified and as directed. |
| 40 | S&F pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of and colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws including dismantling of old AC sheet / plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof / wall coverings complete all as specified and as directed. |
| 41 | M&L for preparation of newly plastered wall surfaces and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) over a coat of primer of same make including scaffolding complete all as specified and directed. |
| 42 | M&L for preparation of old plastered wall surfaces and applying two coats of cement base paint, white or tinted (colour and shade as per new colour scheme approved by GE) including scaffolding for boundary wall complete all as specified and directed. |
| 43 | Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm complete all as specified and as directed. |
| 44 | M&L for preparation of new steel surfaces of any description, exceeding 10 cm in width or girth and apply two coats of synthetic enamel paint, over and including one coat of red oxide primer &complete all as specified and directed. |
| 45 | M&L for preparation of old steel surfaces of any description, exc 10 cm in width or girth and applying one coats of synthetic enamel paint,complete all as specified and as directed. |