Tender For Certain Repair To Offers Md Accn Under Age B/R-I At Amritsar Cantt; 1 Taking down cement or cement lime plaster on brick walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. 2 Material and Labourfor rendering 12mm thick in cement mortar 1:6 on brick work or concrete surface and finished even and smooth without using extra cement and applying two coats of oil bound distemper over and incl one coat of alkali resistant priming paint & wall care putty incl preparation of newly plastered surfaces of wall complete all as specified and directed. 3 Material and Labourfor rendering 15mm thick in cement mortar 1:4 on brick work or concrete surface and finished fair and even without using extra cementand applying two coats of cement base paint on newly plastered surfaces of wall including preparation of surface complete all as specified and directed. 4 Material and Labourfor rendering 10 mm thick on fair faces of brick work or concrete surfaces on ceiling in cement mortar1:3. finishing even and smooth without using extra cement and apply three coats of white wash on ceiling including preparation of new plaster surfaces complete all as specified and directed . 5 Material and Labourfor Cement Concrete in sub floors & pavings 25mm type B1, 1:2:4 ( using 20mm graded crushed stone aggregate) as in sunken portion complete all as specified and directed. 6 Dismantling floor, hearth or wall tiling including cement mortar bedding including backing coat of any thickness and removing serviceable tiles to store and rubbish off the premises complete all as specified and directed. 7 Material and Labourglazed ceramic coloured wall tiles 450mmx300mmx 7mm thick on vertical surfaces such as skirting and dados etc. of shade as approved by Engr-in-Charge set and jointed in neat cement slurry and pointed in coloured cement to match over & including 10mm thick rendering in cement mortar1:4 complete all as specified and directed. 8 Material and Labourfor Non skid ceramic coloured tiles 7 to 8mm thick (Square/reactangular) area of each tiles exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc shade as approved by Engr-in-Charge set and jountedin neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed in cement mortar1:6 complete all as specified and directed . 9 Material and Labourfor Vitrified tiles,light shade 10mm thick (Square/ rectangular) polished, area of each tiles n.exc 0.36 sqm in floors/wall etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and incl 15mm thick screed bed in cement mortar1:6/plaster in cement mortar1:3 complete all as specified and directed. 10 Demolition of Stone slabs and tiles of any description or thickness in floors, aprons etc.Laid, bedded and pointed in any mortar and removal complete all as specified and directed. 11 Material and Labourfor Kota stone slab machine cut pre polished as in steps/ flooring 20-25 mm thick (size not less than 0.5 sqm each) over cement screed base of 15mm thick in cement mortar1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed. 12 All as per srl Item No 11 here-in-before but 18-20mm thick as skirting/dado over rendering 10mm thick in cement mortar1:4. 13 Material and LabourGranite (of any type) work (table rubbed and polished) 20mm thick in steps , jambs, pillars, window cills, cooking plateforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15mm thick rendering in cement mortar1:4 complete all as specified and directed. 14 Supply and fixingin repair 5 mm thick interlocking PVC wall lining consisting of plain colour PVC sheet 1 mm thick inclusive of solvent cement,PVC frames,PVC fasteners/SS screws and all necessary items like C-section at edges/L-section at corners of matching colour etc. complete all as specified and directed. 15 Dismantling boarding incl necessary frame work , any description , fixed in any position with screws and removal complete all as specified and directed. 16 Material and LabourSeamless calcium silicate ceiling made out of 1800mm x 1200mm x 12mm size board of siliceous and calcareous material reinforced with cellulose fibre fixed to the ceiling section with 25 mm long self drilling and tapping screws having phillips head with under head cutter at 200 mm centre to centre, including finshing the joint of face board with specially formulated jointing compound and 48 mm wide fibre tape to provide seam less finish complete all as specified and directed. (Frame work and distempering for ceiling shall be measured and paid separately). 17 Material and LabourGl frame work for seamless ceiling comprising of Gl perimeter channnel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre complete all as specified and directed. 18 Material and labour preparation of newly surface of Ceiling and applying two coats of distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gms/litre, of approved manufacturer, of required shade and colour over a coat of primer complete, as per manufacturers instructions complete all as specified and directed. 19 Demolition of cement concrete in ground floors and paving not exceeding 15 cement mortarthickness ( below or above ground level) and disposing the rubbish complete all as specified and directed. 20 Material and Labourfor 50mm thick PCC 1:2:4 type B-1(using 20mm graded crushed stone aggregate) as in flooring Finishing fair and even without using extra cement complete all asspecified. 21 Material and Labourpreparation of old surfaces (plastered or unplastered) of walls including cornices by brooming down or steel wire brushes, scrapping down smoke soot moulds moss and efflorescent salts, trading oil cut greasy spots and applying one coat of oil bound distemper on walls complete all as specified and directed. 22 Material and Labourpreparation of old surfaces (plastered or unplastered) of walls including cornices by brooming down or steel wire brushes, scrapping down smoke soot moulds moss and efflorescent salts, trading oil cut greasy spots apply one coat of white wash complete all as specified and directed. 23 All as per item No. 22 above but on ceiling surfaces. 24 Material and Labourpreparation of old painted surfacecs of wood and wood based materials of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed. 25 Taking down chowkhat with shuttering (without taking off shuttersfrom frame including grill & guard bars) sizeof shutter not exceeding 1.5 sqm each complete all as specified and directed. 26 Taking down chowkhat with shutters without taking off shutters from frame size of shutters exc. 1.5 but not exceed4 Sqm each complete all as specified and directed. 27 Taking down shutter of any description size of shutter not exc 1 sqm each complete all as specified and directed. 28 Taking down shuttersof any description size of shutter exc 1 sqm but n.exc 2 sqm complete all as specified and directed. 29 Taking down Shutters of any description of size exceeding 1 sqm and not exceeding 2 sqm each complete and refixing in the same opening all as specified and directed after easing and adjustment complete all as specified and directed. 30 Material and Labourin repair 18/19mm Prelaminated particle board, interior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work 31 Supply and fixingpressed steel frame for doors with one or two rebates size of frame 125mm x 60 mm including necessary fixing lungs, hinges, lock strike plate etc. complete all as specified and directed. 32 Supply and fixingfactory made 35 mm thick flush shutters solid core construction with block board core and plywood face panels incl a shope coat of pink primer complete all as specified and directed. 33 Supply and fixingfactory made 35 mm thick glazed and Skelton door shutters IInd class hard wood open rebated prepared to receive in SSR part-I class 8 (a) glass gage dividing in squares size of member as per specified incl a shope coat of pink primer complete all as specified and directed. 34 Supply and fixingfactory made solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with M S square tube, fixing lugs, butt hings, etc. complete all as specified and directed. 35 Supply and fixingFactory made solid panel PVC doorshutter 30 mm thick (style) con-sisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be cov-ered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain col-our PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S. frame welded / sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, suppling & fixing in the frame at site as per specification & drawing complete all as specified and directed. 36 Supply and fixingfactory made 30mm thick Glazed and skeleton door/window shutters , open rebated and prepared to receive glass, gauze, etc. divided in to quares,with plain, chamfered or rounded , mitred and rebatedsash bars,any numbers ; edges of framing plain, chamfered or rounded , fitted with cut and mitred beads for securing glass, etc., sizes of members of shutters as specified in SSR Part I, Section 8 clause8.24 (b) ; supplied and fitted to chowkhats 37 Supply and fixing in repairContinuous (piano) hinges, Width of flaps (when open) in 40 mm mild steel, bright finish or electrogalvanised all as specified and directed. 38 Supply and fixingpowder coatedaluminium frame for doors ,windows, ventilators, partition with one or more rebates including joining cleats, rubber neoprene packing for fixing complete all as specified and directed.( Min. thickness of powder coating 50 micron) 39 Supply and fixingAluminiumpowder coated (of any colour) window and ventilator shutters, fixed type without sash bar, aluminium section weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws etc. complete all as specified .(Min. thickness of powder coating 50 micron) 40 Supply and fixingAnodised aluminium grill of approved design/pattern, with approved standered section and fixed to the window frame with CP brass/SS screw@ 200mm c/c,including cutting the grill to proper opening size for fixing and opration of handle and fixing approved anodised aluminium section around the opening all complete as per requirement and direction of Engineer-in-charge. 41 Supply and fixingSheet glass, 5.5mm thick ordinary quality, in squares,exceeding 0.50 sqm in each pane including rubber packing and aluminium beading complete all as specified and directed 42 Supply and fixing factory madeBox type steel window double (glazed & gauged) made of ERW tube P- section of size 60 mm x 25 mm double rebated outer frame comprise glazed skelton shutter door frame of ERW tube P-section size 50 mm x 20 mm with two Nos openable leaf cnsisting of two Nos of sash bar of T-sec 20 mm x 3 mm welded to frame with one No vertcale mullion of ERW of ERW box type T-section size of 60 mm x25 mm FI 2 mm thick welded / screwed to frame for fixing of wire guage/glass including fixture and fitting like as handle, tower bolt stopper , cleat, pintal hinges, holdfast, a shope coat of red oxide primer primer etc, all as shown on drg No.CEJZ/TD-06/07 and CEJZ/TD/07/07 or as per existing complete all as specified and directed. NOTE : Guard bar if requied , Sheet glass, wire cloth and painting shall be measured and paid for Separately 43 Material and Labour for factory made Box type steel ventilator made of ERW tube P-section of size 60mmx25mmouterframe ( single rebated), comprisesglazed shutter, frame of ERW tube and FI 2mm thick welded/screwed to frame for fixing ofsheet glassincluding fixture and fittingslike as Stopper, Cleat, Pintal hinges, holdfast etc all as shown on drg No CEJZ/TD1019/08 sheet 1/3 to 3/3 dt 01 May 2008/as per existing incl. a shope coat of red oxide primer complete all as specified and directed.NOTE : Guard bar if required , Sheet glass, wire cloth and painting shall be measured and paid for Separately. 44 Supply and fixingMS handles 150mm long, cast type anodised complete all as specified and directed. 45 Supply and fixingMS anodised barrel tower bolt 150mm long complete all as specified and directed. 46 Supply and fixing Floor door stopper of aluminium alloy body with hard drawn steel spring 140mm long complete all as specified and directed. 47 Supply and fixing300mm long aluminum alloy anodized sliding door bolt with hasp and staple(bolt type)and fixing clips of sheet cast or ectruded sec and fixing bolts and sliding bolts of extruded sec or cast aluminum alloy complete all as specified and directed. 48 Supply and fixingbutt hinge medium weight cold rolled stainless steel complete size 100mm complete all as specified and directed. 49 Supply and fixingMS 300mm long ordinary Helical mild steelstove enameled black door springs including rollers and roller plate complete all as specified and directed. 50 Supply and fixing100mm long Hasp and staple , safety type, Aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed. 51 Supply and fixingstainless steel wire cloth, 0.36 mm nominal dia. of wire and average width of aperture 1.40 mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and directed. 52 Hacking out old brocken glass ( any thickness , size , quality or description ) from wooden/metal frames or stone, concrete or brick surrounds , glazed with putty or fixed with beads complete all as specified and directed. 53 Supply and fixing3.5mm thick Sheet glass, ordinary qualityand glazing with oil putty/wooden beading in square n exc 0.5 sq.m. in each pane complete all as specified and directed. 54 All as per item no. 53 above but figured glass pin head type. 55 Material and Labourfor preparation of undecorated wooden surfaces of any description , not otherwise described , over 10 cm width or girth and applying two coats of synthetic enamel paint complete all as specified and directed. 56 Material and Labourtwo coats of synthetic enamel painting on steel surfaces of any description over 10 cement mortarin width or girth not otherwise described including prepration of surfaces complete all as specified and directed. 57 Supply and fixing in repair 18/19 mm thick prelaminated HDMR board, interior grade with decorative choice lamination fixed with screw as in shelves/shutters complete all as specified and directed. 58 Supply and fixing in repair 5 mm thick PVC board as in back side of for kitchen cabinets etc complete all as specified and directed. 59 Supplying and fixing stainless steel rolling drawer pull type suitable for kitchen cabinets with all fixing arrangement area of each drawer n exc 0.30 sqm of vertical face having depth 450mm to 600mmcomplete all as specified and directed. Note:- Net area of front finished surface will be measured for payment. 60 Supply and fixing 75 to 80 mm long brass handle complete all as specified and directed. 61 Dismantling structural steel work including doors, gates but excluding framed truss etc.and removal complete all as specified and directed. 62 Supply and fixingframed work as door, chowkhats, andGrill gates of angle frame work fixed with Nut & bolt to wall or other section complete drilling or fixing welding be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings and hanging also festering and fixing conforming to Fe-290(Gde-E-165) complete all as specified and directed. 63 Dismantling water tank and Supply & Fixing rotational moulded polythene water storage tank of 1000 litre capacity (cylindrical vertical with closed top) triple layered hoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore and removal complete all as specified and directed. 64 Dismantling water tank and Supply & Fixing rotational moulded polythene water storage tank of 500 litre capacity (cylindrical vertical with closed top) triple layeredhoisted and fixed in position all as specified in SSR Part-1 including Ball valves high pressure PTMT with epoxy coated Aluminium rod & High density plastic ball screwed for iron pipe and fixed to GI pipe of 20mm bore and removal old complete all as specified and directed. 65 Disconnecting existing tank 1000 litre capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, including all fitting complete all as specified and directed. 66 Disconnecting existing tank 500 litre capacity, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position including Cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes, including all fitting complete all as specified and directed. 67 Taking up or down 15mm bore steel tubing and connections , including cleaning for re-fixing or removal incl necessray cuttings/chases & making good in cement mortar 1:3 complete all as specified and directed. 68 Taking up or down 20mm bore steel tubing and connections , including cleaning for re-fixing or removal incl necessray cuttings/chases & making good in cement mortar 1:3 complete all as specified and directed. 69 Supply and fixing15mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. 70 Supply and fixing20mm bore tubes (medium grade) galvanised with all fittings and fixed to walls and ceiling or laid in floors complete all as specified and directed. 71 Refixing 15mm old steel tubing and connections in new or old position (walls, ceiling , floors, etc.). Note:- old serviceable GI tubing obtained from Srl item No 58 will be reused incl provision of necessary new fittings. 72 Refixing 20mm old steel tubing and connections in new or old position (walls, ceiling , floors, etc.). Note:- old serviceable GI tubing obtained from Srl item No 59 will be reused including provision of necessary new fittings. 73 Taking down eaves gutters and rain water pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including removal complete all as specified and directed. ( measured overall as fixed along the centre line over fittings and accessories) 74 Supply and fixing110mm bore PVC(SWR) pipes single socketed in any lengthfixed to walls with dash true nut and bolt at every 2mtr length including)includingall fittings complete all as specified and directed by Engineer-in-charge Make:-supremo,Finolex,Jyoti. 75 Supply and fixing75mm bore PVC(SWR) pipes single socketed in any length fixed to walls with dash true nut and bolt at every 2mtr length including)includingall fittings complete all as specified and directed by Engineer-in-charge Make:-supremo,Finolex,Jyoti. 76 Supply and fixing 110mm bore PVC (SWR) bend any radius complete all as specified and directed. 77 Supply and fixing110mm PVC (SWR) junction single, (Single T) equal or unequal complete all as specified and directed. 78 Supply and fixing 75mm bore PVC (SWR) bend any radius complete all as specified and directed. 79 Supply and fixingin repair 100mm bore PVC (SWR) gully trap, plain with grating including jointing with solvent cement complete all as specified and directed. 80 Supply and fixingin repair 75mm bore PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. 81 Supply and fixingin repairs vitreous china wash down water closet pan pedestal pattern white including fixing bolts incl white seat coverwith flat bottom and cover and mild steel chromium plated hinging device (excluding flushing cistern and flush pipe) complete all as specified and directed. 82 Supply and fixingin repairs vitreous china squatting pan of Orissa pattern size 580x440mm white with integral foot rests (excluding flushing cistern and flush pipe) including making good the dismantled portion to match with existing surface of floor complete all as specified and directed. 83 Supply and fixingin repairs 10 ltrs capacity PVC valveless syphonic action flushing cistern low level with inlet ball valve, flush pipe of polythelene of low or high density or PVC 32mm dia comlplete all as specified and directed. Make: CERA/Jaquar/Somany/Parryware 84 Supply and fixingin repairs plastic water closet seat cover white with flat bottom and cover and mild steel chromium plated hinging device complete all as specified and directed. 85 Supply and fixing in repair Chromium plated Health faucet in repair with 1.5 metre long chain complete all as specified and directed. 86 Supply and fixingin repairs flushing jet including pipe for Europian type closet including fixing to 15m dia pipe suitable length with brass check nut complete all as specifed and directed. 87 Supply and fixingin repair toilet paper holder of brass chroumium plated with CP cover complete all as specified and directed. 88 Supply and fixingin repairs vitreous china wash hand basin white with flat back type size 550x400mm excluding taps chain and plug and porcelain stopper but including brackets CP waste coupling 32mm and PVC waste pipe 32mm dia including cutting for and pinning ends of brackets complete all as specified and directed. 89 Supply and fixing in repair600mmx450mm bevelled edge mirror of selected quality glass, mounted on 6mm thick AC building board or commercial plywood and fixed to wooden plugs with chromium plated brass screws and cup washers complete all as specified and directed. 90 Supply and fixingin repair Brass Chromium plated Tubular towel rail, 20 mm dia. D type, 60 cm long between flanges complete all as specified and directed. 91 Supply and fixingin repairs glass shelve assembly 60cm in oval shape consisting 5.5mm to 8mm thick glass including CP guard railing with double rail complete all as specified and directed. 92 Supply and fixingin repairs pillar taps 15mm dia cast copper alloy with capstan heads chromium plated screwed down high pressure with long screwed shanks and fly nuts screwed for iron pipes complete all as specified and directed. 93 Supply and fixingin repair PVC wastepipe 32mm dia suitable for WHB/Sink complete all as specified and directed. 94 Supply and fixingin repair glass corner of 30cm radius made of 5.5mm thick sheet galss with CP guard rails fixed to walls with brackets complete all as specified and directed. 95 Supply and fixingin repair brass chromium plated soap dish fixed with screws to walls complete all as specified and directed. 96 Supply and fixingin repairs CP shower rose fancy type with CP arm complete all as specified and directed. 97 Supply and fixingin repairs stop valves brass chromium plated 15mm dia with long shank and cup concealed type complete all as specified and directed. 98 Supply and fixingin repairs centre hole wall/ wash basin/ sink mixture cast copper alloy chromium plated with capston head srewed down high pressure withlettered hot or cold with long screwed shanks fly nut screwed for iron pipe 15mm dia complete all as specified and directed. 99 Supply and fixingin repairs chromium plated stop valve /Angle valve 15mm bore fancy type screwed down for high pressure complete all as specified and directed. 100 Supply and fixingin repairs PVC connection pipe 15mm dia 600mm long with brass check nut at both ends complete all as specified and directed. 101 Supply and fixingin repairs CP bib tap 15mm dia long body screw high pressure for iron pipe complete all as specified and directed. 102 Supply and fixingin repair 100mm dia CP grating with or without hinge type or hole type complete all specified and directed. 103 Supply and fixingin repair stainless steel kitchen sink with draining board made of 1mm thick sheet for kitchen with plug washers waste pipe cast iron cantilever bracket over all size 915 x 460mm with bowlsize 410x310x160mmcomplete all as specified and directed. 104 Supply and fixingin repair stainless steel kitchen plate rack size 900 x 750 x 300mm deep made out of 1mm thick sheet including fitting arrangement complete all as specified and directed. 105 Supply and fixingin repair 25mm dia stainless steel Curtain rods/ rails with Brass brackets, stops, rollers, finials, 1 pair of Brass decorative knobs for each curtain rod etc. complete all as specified and directed. 106 Supply and fixing in repair wall mounted PVC bathrrom Mirror Cabinet,Size 21x13 inch complete all as specified and directed. 107 Material and Labourfor repairing of chajja / roof projection by taking down old plaster applying 10 mm thick rendering in cement mortar 1:3 including providing chicken mesh wire netting 25, gauge, 20 mm mesh, finishing the surface even & smooth with out using extra cement complete including neccsary scaffolding upto 08m height complete all as specified and directed. 108 Removal of plants / vegetation growth etc of height exc 30 cm but not exc 45 cm from roof or parapet of building including removing of root and making good disturbed surface with cement mortar 1:3 including supply & mixing of liquid water proofing compound as per manufacturer instructions complete all as specified and directed. 109 Dismantling Brick tiles or terracing tiles, single layer on roofs and removal complete all as specified and as directed. 110 Demolition mud in roofs, any thickness, including plastering and leeping (whether full thickness removed or only a part thereof) including roof treatment if any Complete all as specified and as directed by Engineer-in-Charge. 111 Material and Labour for PCC 1:2:4 type B-1 (using 20mm graded crushed stone aggregates) as in padding concrete fair finish, roof kerbs or mud stops, rounded or chamfered on edges and like including weathering slight rounded and throating; Complete all as specified and as directed. 112 Material and Labour for applying evenly a tack coat of industrial bitumen 85/25 grade @ 1.2 Kg/Sqm including bitumen priming coat, cleaning surfaces etc; Complete all as specified and as directed. 113 Supply and Fixing (minimum) 3mm thick APP film based poly meric membrance minimum weighing 3Kg per Sqm reinforced with polyester non wove fabric (weight not less than 150 gms/sqm) land on primed surface by forced application over entire roof area with over lapping 100mm to either sides and sealed in after cleaning down the roof by brooms complete all as per manufacturers instructions all aspecified anddirected. 114 Material and Labour for 40mm thick brick tiles, laid on and including 15 mm thick cement mortar 1:4 and joints grouted and pointed flush in cement mortar 1:3 mixed with 5% crude oil by weight of cement; Complete all as specified and as directed. 115 All as per Srl Item No. 114 here-in-before but except brick tiles. Note:-Old serviceable tiles obtained from demolition shall be reused. 116 Material and Labourfor cleaning of dust & dirt , Removal of all loose existing bituminous material or with chipper & applying heat torch gun to get smooth plain finished surface. Repair all joints & cracks with Highly Elastic bituminous Cold applied Putty-Tarplast- having penetration after setting upto 8mm & confirming to IS 1580:1991. Any annular space between drain pipe and concrete should be filled with mortar admixed with ShaliSBR latex of STP Ltd. Making necessary Gola 75x75 mm with rich cement mortar 1:1:2 incl admixed with ShaliSBR latex of STP Ltd at the interface of horizontal & Vertical junctions complete all as specified and directed. 117 Material and Labour for Slightly damp the surface, avoid standing Water. Prime the surface with Tarfelt LM mixed with potable water in the ratio 1:1 and apply @ 400gm/sqm (as per surface condition). Allow the primer to touch dry in tacky position in open atmosphere. Thenafter apply 1st coat of Tarfelt LM(Liiquid membrane) having elongation 200% confirming to ASTM-C-412 & bridging of 8mm confirming to ASTM-C-836 with tensile strength after 7 days 0.5mm confirmin to ASTM-C-412 with no diluation of water on primed surface is still tacky with consumption of 0.7 kg/sqm. lay Geotex of 45 GSM/Fibre mesh simultaneously and paste it properly with overlap of 50mm. Allow the first coat to dry for 10-12Hrs. Apply 2nd coat of cured first coat with consumption @ 0.7kg/sqm in opposite dierction offirst coat by Brush or roller. Sprinkle sand @ 200Gm P/Sqm while the coating is stick to facilitate plastering for protection screed. Allow it to dry for 10-12 hrs . Apply 3rd coat if required as per site reqirement complete all as specified and directed. 118 Material and labour for damp proofing treatment to wall with two component acrylic polymer cementitious water proof elastomeric coating food grade mix to form uniform slurry and apply with paint brush as first coat then laying a layer of fibre glass mesh cloth as first coat is still green with overlap of joints of fibre mesh not be less than 10mm, then finally apply second layer mix by brush to entire surface of container covering 0.6-0.78 sqm/G at 1mm thickness in two coats depending on the level of substrate and curing it minimum 3 days complete all as specified and directed.Note : Quoted rate shall be deemed to be inclusive of materials all labours, tools and plants, scaffolding and working upto height 6m etc. 119 Removal of all the loosely adhering material like dirt, dust, organic solvent (de-shuttering/curing free compound) & oil etc. from the surface by using emery paper, chisel or wire brush etc. Efflorescene, surface should be cleaned throughly to remove all loose particles from the surface.Wash the surface properly with clean water & allow the surface to dry completely before application of the product. Surface cracks mustfilled (<3mm) bt crack, damaged portion and hollow areas must be repaired by Birla white levelplast (Polymer cement modified mortar product).Mixing with 01kg product with 600to 650ml clean water After thorough mixing, apply the first coat on the clean & dry surface uniformly with the help of a painting brush.Allow the surface to dry for at least 4-6 hours & then apply the second coat of the product. Application of the second coat must be applied in a crosswise direction for better results.Leave the surface to dry completely, preferably 10-12 hours, before the application of other top coat products.The total thickness of both coats should be limited to a maximum of 1.5 mm.Re-plaster the surface. Allow the plastered surface to cure for 7 days before the application of two coats of Birla White Wall Seal Waterproof Putty. Apply Interior primer followed by top coat paint to get a superior finished surface complete all as specified and directed. 120 Taking down copper/aluminium point wiring (light, fan, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, bells etc, removing materials to store for keeping in safe custody or for taking credit (creit for above items shall be made as per condtitions separately) including necessary cuttings/chases and making good disturbed surface of walls, floors, ceilings etc. where required as per existing complete all as specified and directed 121 Material and Labour for Modular concealed existingpoint wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn through and existingPVC concealed/conduit with all fittings and accessories including pressed steel powder coated sunken teRunning metre inal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc complete all as specified and as directed. Note:1. Switch,socket,regulator, lamp holders, ceiling rose, bells etc,shall be measured and paid separatelya) For one light /fan/ buzzer point controlled by one 5 Amp switch one way 122 b).For one three pin socket outlet 5 Amps independent board complete 123 c) For one three pin 5 Amps socket outlet on the same board with other switches 124 d) For one light point controlled bytwo way switch 125 All a per item No. 121 here-in-abovebut with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper multi stranded conductor connecting to common earth dolly complete. 126 Material and Labour for Modular surface point wiring for one light point/fan point/bell point controlled by one switch ( using red,black,green colour wires as colour codings) complete with 1.5 sqmm ( nominal cross section area ) single core FRLS PVC insulated unsheathed and multi stranded copper conductor cable 1100 volt ( ISI marked ) drawn and including surface PVC conduit with all fittings and accessories i.e. pipe bend,pipe hook, elbow,juction boxes etc including pressed steel powder coated sunken teRunning metre inal box suitable for Modular switch socket ( min 50mm deep and 1.6 mm thick sheet ,suitable size ) concealed in wall , including inner and outer plates ( cover plate ) suitable for fixing the modular switches/sockets/regulator etc including provn of 1.5 sqmm single core FRLS PVC insulated multi stranded copper conductor wire continues as earth wire connected to earth dolly etc complete all as specified and as directed. Note:1.Switch,socket,regulator, lamp holders, bells etc,shall be measured and paid separatelya) For one light /fan/ buzzer point controlled by one 5 Amp switch one way 127 b).For one three pin socket outlet 5 Amps independent board complete all as specified and directed 128 c) For one three pin 5 Amps socket outlet on the same board with other switches, complete all as specified and directed 129 d) For one light point controlled by two way switch, complete all as specified and directed 130 All a per item No. 126 here-in-abovebut with 2.5 Sq mm size cable multi stranded FRLS copper wire unsheathed for one 3 pin socket outlet 15 Amps on independent board including continuous earth wire of PVC insulated 2.5 Sq mm copper solid conductor connecting to common earth dolly complete all as specified and directed 131 Supply and FixingModular switch flush type one way 6 Amp, 230 volts complete all as specified and directed by Engr-in-Charge., complete all as specified and directed 132 Supply and FixingModular switch flush type two way 6 Amp, 230 volts complete all as specified and directed. 133 Supply and FixingModular socket 6 Amp 2/3 pin combined 2 modulecomplete all as specified and directed. 134 Supply and FixingModular switch flush type one way 16 Amp, 230 volts complete all as specified and directed. 135 Supply and FixingModular socket 6 /16 Amp 2/3 pin combined 2 modulecomplete all as specified and directed. 136 Supply and FixingModular switch bell push switch 6 Amp 1 modulecomplete all as specified and directed. 137 Supply and Fixing ceiling rose 65X50 mmthree Running metre inals complete all as specified and directed. 138 Supply and FixingLamp holder bakellite type with black plate suitable for batten fitting complete all as specified and directed. 139 Supply and Fixing Ding Dong bell AC 230 Volts complete all as specified and directed . 140 Supply and FixingModular stepped type electronic fan regulator flush type on the existing phenolic laminated sheet etc. as reqd heavy duty 230 voltscomplete all as specified and directed. 141 Supply and Fixingin replacement for vertical sheet steel metal enclouser distribution boards, double door factory made3 phase 415 volts 4 way with 200 amps rating copper bus bar and PVC insulatedcopper wire of suitable size from the MCCB to the out going circuits oneincoming MCCB and suitable outgoing MCBs circuits comprising of 3 phase 4 wireof suitable rating complete all as specified and directed with the following accessories. (a) MCCB 100 amps, 25 KA, TP, 415 volts, 50 Hz = 01 No. 142 Supply and Fixingin replacement sheet metal enlosure DBs double door factory made flush fixed complete with 200 amps rated bus-bar 240 volts single phase 8 ways including necessary brick work and plaster to match with the existing surface complete all as specified and directed. 143 Supply and Fixing in replacement sheet metal enlosure DBs double door factory made flush fixed complete with 200 amps rated bus-bar 240 volts single phase 12 ways including necessary brick work and plaster to match with the existing surface complete all as specified and directed. 144 Supply and Fixing in replacement MCB single pole 6 to 32 Amps all as specified and directed. 145 Supply and Fixingin replacement MCB DP 40 Amps 240V, 10 KA, complete all as specified and as directed 146 Supply and Fixing in replacement 40 to 63 Amps MCB TPN, 415 Volt complete all as specified and directed. 147 Supply and Fixing in replacement of Sheet metal single pole and neutral enclosure, 240 volts with a two pin and earth plug and socket complete with one single pole MCB capacity 20 amps complete as specified and directed (for AC and geyser). 148 Supply and Fixing in repair ,Fresh Air fan of size 250mm, Plastic body 1200RPM, electrically driven, 230volts, 50Hz, single phase, AC supply, dynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3 long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to fan complete all as specified and directed. Note: Making suitable openingwhere required for fixing air fan shall be deemed included in the quoted rate of item. 149 Supply and Fixing in repair , Exhaust fan of size 300mm, Heavy duty 1200RPM, electrically driven, 240volts, 50Hz, single phase, AC supply, dynamically balanced impeller for smooth and vibration free operation, complete with louvers,nuts for fixing exhaust fan and 3 long bolts, nuts for fixing louvers with civil work,wall hole, and provision of PVC insulated, flexible copper conductor cord of size 23/0.0076, three core from ceiling rose to exhaust fan for giving connectioncomplete all as specified and directed. Note: Making suitable openingwhere required for fixing exhaust fan shall be deemed included in the quoted rate of item.Note for item No. 95 & 96 : old retrieved matrial shall be deposited in store yard of MES 150 Supply and Fixingin repairsLED tube light 20 watt, (4 long), 6500K, wall mounted, E-lite LED curve with high lumen batten with efficacy not less than of 100 lumens, with integrated electronic driver complete with all accessories complete all as specified and directed. 151 Supply and Fixingin repairs LED decorative Gate ligh/Garden lights 20 watt light fitting with allaccessories includingmaking connections by using suitable size of PVC wire any type complete all as specified and as directed. 152 Supply and Fixing in repairs LED street light fitting powder coated pressure die cast alminium compact High power LED street light with heat resistant toughened glass for 25 watt with IP66 protection and impact resistance of IK07 with 10KV Built-in Surge Protection Devicebracket made out of GI Pipe 40mm medium grade 1.2 mtr long made to shape with fixing clamps of MS Flat 40x6mm nuts bolts Complete all as specified and directed. 153 Supply and Fixingin repairs 1100 volts grade heavy duty PVC cable insulated aluminium conductor served with inner sheating of PVC tape and over all PVCsheathed in service connection stranded conductor flatr 6 sqmm 2 core cable complete all as specified and directed. 154 Supply and Fixingin repairs, Sub main wiring with two single pole 6 sqmm (nominal area) stranded copper conductorFRLS PVC insulated and unsheathed cable drawn inexisting non metalic PVC rigid conduit medium grade of suitable size with all standared fitting ,including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 6 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , complete all as specified and directed.Note:- 1 Two runs of 6 sqmm main cable one run of 6 sqmm for earth cableshall be measured as one unit/ one running metre. 155 Supply and Fixingin repairs, Sub main wiring with two single pole 6 sqmm (nominal area) stranded copper conductorFRLS PVC insulated and unsheathed cable drawn inand including non metalic PVC rigid conduit medium gradeof suitable size with all standared fitting , on surface including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 6 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , complete all as specified and directed.Note:- 1 Two runs of 6 sqmm main cable one run of 6 sqmm for earth cable & conduit shall be measured as one unit/ one running metre. 156 Supply and Fixingin repairs, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor on surface FRLS PVC insulated and unsheathed cable drawn inexisting non metalic PVC rigid conduit medium grade of suitable size with all standared fitting ,including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , complete all as specified and directed.Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cableshall be measured as one unit/ one running metre. 157 Supply and Fixingin repairs, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductor on surface FRLS PVC insulated and unsheathed cable drawn inand including non metalic PVC rigid conduit medium grade of suitable size with all standared fitting , on surface , including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , complete all as specified and directed.Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cable & conduit shall be measured as one unit/ one running meter. 158 Material and Labour in repairs Earthing complete with galvanized steel earth plate electrods of size 60cmx60cmx6mm thick burried directly in ground vertically(earth pit not less than 2.25 metre deep below noRunning metre al ground level) with top edge of the plate not less than 1.5 metre below noRunning metre al ground level connected to galvanized iron or steel earth wire 4 mm dia by means of bolts nuts check nuts and GI washers of Galvanised iron protected by steel pipe 15mm (light grade) all as shown in elecrrical plate No.3 of SSR Part-I and connecting to earthing test point (earth test point to be provided at 5 mtr distance from earth pit) and testing on completion including necessary excavation and earth work. The rate also include charcoal dust and salt in alternate layers 25 mm dia light grade GI pipe, funnel, wire mesh. Concrete 1:3:6 type C-1 for pit and RCC pit cover. The extra cost of the water- ing pipe,bends,elbows shall be included in the unit rate, complete all as specified and directed.Note : RCC pit cover shall be precast of RCC 1:2:4type B-1 80mm thick reinforced with XPM weighing notless than 4 Kg/Sqm including testing complete all as specified and directed. 159 Supply and fixingin replacement, Sub main wiring with two single pole 4 sqmm (nominal area) stranded copper conductorFRLS PVC insulated and unsheathed cable drawn inexisting non metalic PVC rigid conduit medium grade of suitable size with all standared fittingon surface ,including one run of continuous PVC insulated standed copper conductor PVC insulated stranded copper conductor FRLS cable 4 sqmm (nominal area) for earth continuty , including taking out and removal of old sub main wiring , complete all as specified and directed.Note:- 1 Two runs of 4 sqmm main cable one run of 4 sqmm for earth cableshall be measured as one unit/ one running meter.