| 1 | Schedule \"A\" Part – I to Schedule \"A\" Part – XI:NOTE: Schedule \"A\" Part – I to Part – XI are pre-priced by MES. Bidders shall insert their Lump sum amount in Green coloured field under Column - 6 only |
| 2 | Lump sum price worked out by the contractor for \"Buildings & Structures\",as listed in Schedule \"A\" Part – I |
| 3 | Lump sum price worked out by the contractor for \"EARTH WORK AND SITE CLEARANCE\",as listed in Schedule \"A\" Part – II |
| 4 | Lump sum price worked out by the contractor for \"INTERNAL WATER SUPPLY\",as listed in Schedule \"A\" Part – III |
| 5 | Lump sum price worked out by the contractor for \"INTERNAL ELECTRIC SUPPLY\",as listed in Schedule \"A\" Part – IV |
| 6 | Lump sum price worked out by the contractor for \"EXTERNAL WATER SUPPLY\", as listed in Schedule \"A\" Part – V |
| 7 | Lump sum price worked out by the contractor for \"EXTERNAL ELECTRIC SUPPLY & DG SET\", as listed in Schedule \"A\" Part – VI |
| 8 | Lump sum price worked out by the contractor for \"SEWAGE DISPOSAL\",as listed in Schedule \"A\" Part – VII |
| 9 | Lump sum price worked out by the contractor for \"ROAD, PATH & CULVERT\",as listed in Schedule \"A\" Part – VIII |
| 10 | Lump sum price worked out by the contractor for \"BOUNDARY WALL\",as listed in Schedule \"A\" Part – IX |
| 11 | Lump sum price worked out by the contractor for \"MAIN GATE WITH WICKET GATE & ASSOCIATED WORKS\",as listed in Schedule \"A\" Part – X |
| 12 | Lump sum price worked out by the contractor for \"PILE FOUNDATION\",as listed in Schedule \"A\" Part – XI |
| 13 | Schedule \"A\" Part - XII: [Miscellaneous Items] [Internal Water Supply; Internal Electric Supply; External Water Supply; External Electric Supply & DG set; Sewage Disposal; Road, Path & Culvert; Boundary wall;Main gate with wicket gate & associated works; Pile foundation] |
| 14 | Removing and disposal of malba/ sludge/ waste material from the site including dewatering of accumulated water by pumping out, loading, transporting and dumping the same at designated municipal dumping areas out side ICG premises complete all as directed. |
| 15 | S&F Bib taps, Two-way, 15mm bore, cast copper alloy, fancy type, chromium plated with crutch handle, long body with wall flange, screwed down, screwed for iron pipe or for brass ferrule all as specified and as directed. |
| 16 | Drilling and tapping cast iron water mains (in position) for branch connections of 25mm internal dia complete including turning water off and on and draining and refilling the system as required |
| 17 | Supply, Installation, Testing & Commisioningof high beam, multi functional, fully-automatic, uni-directional, 300 watt LED search light, Efficacy >140 lm/w, CCT 5500K, LM6 housing, front dia >440mm, operating voltage: 90V- 300V, 50hz, PF >0.95, THD <10%, CCT: 5500K, CRI >70, Optics used- PMMA/PC lens, narrow beam 5°, average lux level at 10 meter > 10000 with circle of approx 1 meter, toughened glass with silicon gasket, over voltage / under voltage & short circuit protected, confirming to LM79, LM80, IK07, IP66, lux Cert., Type tested- IS:10322, IS:15885 and BIS certified. This search-light should be installed on rotating disc of revolving mechanism with suitable motor-gear unit & designed to rotate 360˚ continuously over the night in horizontal plane and tiltable upto 45° through motor. A separate wall mounted wired control panel (consists of MCBs, Voltmeter, Fuse, LED indicator), inbuilt features of speed controller (1 to 10 rpm), Auto / Manual, Reverse / Forward, Up / Down through push buttons for remote operation. The revolving mechanism is fully covered with weather & rust proof die cast fiber box with maintenance window & side doors, provision of foundation holes at bottom for proper installation complete all as directed.[Model number : MRSL-LRFLL25-PC301 of Make: M/s Kalin Engineering Works or equivalent in M/s Signa Searchlights Ltd./ M/s KT Automation Pvt Ltd.] |
| 18 | S&F thermoplastic ABS cable junction box of size 560x380x180mm, IP-66/67 ingress protection,IK-08 impact resistance complete with terminal suitable for 16/25 sq. mm cable, fixed to pole with all fixing arrangment complete all as directed (Cat Part No. HE- ABS 5638 18G of make Trinity Touch or equivalent in Hensel/ Sintex/ Legrand) |
| 19 | M&L for street light bracket made of GI pipe medium grade 40mm bore dia, appx 1.50 m long bent to shape suitable for fixing street light fixed to pole with 2 Nos of MS FI brackets with nuts and bolts complete including painting with two coats of aluminium paint over a coat of zinc chrome primer all as specified and as directed |
| 20 | S&F multi core PVC insulated and PVC roundsheathed copper conductor cables with 3 core of 1.0sq.mm from street light pole mounted juntion box to street light fittingsdrawn through and including steel conduit of 15 mm dia fixed to poles with necessary flat iron clamp etc completeall as specified. |
| 21 | Supply, installation, testing & commissioning of diesel engine driven generating set with sound proof canopy as per CPCB norms of capacity 10 kva/8 kwoutput underNTP conditions, 50 Hz at 1500 RPM, 0.8 PF, 3 phase 4 wire, AC 400/440 Volts, complete BIS/IS compliant with an integral acoustic enclosures including two years maintenance spares as indicated below and control panel comprising of the following. |
| 22 | (a) PRIME MOVER:- Prime mover shall be coolant cooled diesel engine of suitable capacity for driving alternator of capacity 10KVA/8 KW, 50Hz at 1500 RPM, 0.8 PF, 3 phase 4 wire, AC 400/440 Volts under NTP conditions, complete mounted on common base plate with flexible coupling, meeting the requirement of latest BIS/IS specification with electric starting device with all standard fitting and battery of suitable capacity all as recommendes and specified by the manufacturer.Theengine shall be equipped with all standard fitting as per manufacturer\"s recommendations.(b)ENGINE INSTRUMENTS PANEL:- All relevant parameters shall be conventionally displayed in complete panel there by providing easy monitoring of lubricant oil pressure, coolant temprature, battery charging, ammeter, RPM and hour meter, starting switch etc.(c) FUEL TANK:-Fuel tank of capacity capable to run 12 Hrs with 100% load should be installed including all necessary connection from fuel tank to engine and overflow engine to tank and for overflow.(d) SOUND PROOF CANOPY:- The canopy shall be provided as per latest CPCB IV+ norms to reduce noise pullution.(e) ALTERNATOR:-10KVA/ 08 KW out put, 3ph, 50Hz, 415 volts, 4 wire, Ac Supply, 0.8 power factor, brushless type, screen protected, revolving field, self excited, self regulated through an AVR conforming to relevant IS/BIS standards. Engine and alternator shall be mounted on specially designed base plate of rigid welded construnction with anti vibrations pads. The enginbe and alternator shall be placed on foundations as per the manufacturer\"s recommendations/ site requirement and the quoted rate deemed to include for this provision. |
| 23 | (f)CONTROL PANEL :-The standard microprocessor based cointrol panel shall be fabricated out of 3.15mm thick CRCA sheet and power coated in side and out side and shall displays sas follows.(i) Voltage of all three phases, (ii) Current of all Three phases, (iii) Frequency, (iv) Bus Bar Chamber with aluminium busbar of rating 40 Amps-04 Nos, (v) C.T. 100/5 Amps-03 Nos. (vi) MCCB TPN of 32 Amps capacity -01 No |
| 24 | M&L for LLDPE septic tank of 10 user capacity, designed to carry sewage & sullage water complete including all fittings/ fixtures, excavation & earth work in any type of soils, PCC 1:4:8, type D2 foundation, vent shaft, connections etc all as required and as directed |
| 25 | M&L for Soakage well of 1.20m internal dia, 3.0m effective depth with PCC 1:3:6 type C2 foundation, honey comb brick masonry in CM 1:4 with top ring in RCC M-25, RCC cover slab in RCC M-25 or SFRC cover, complete including intersepting chamber & screen chamber made of brick masonry in CM 1:4, intersepting pipes of RCC/ DWC, filling with brick bats etc all as specified and as directed. |
| 26 | S&F road safety convex mirror of 800mm dia, adjustable type with polycarbonate body mounted on 2.5m long SS pole of 50mm NB with adjustable bolts & nuts for installation, duly embedded in PCC 1:3:6 type C2 complete including necessary excavation & earth work as required.Make: 3M/ Dark Eye/ ABS Industry |
| 27 | Providing and fixing concertina coil fencing with punched tape concertina coil 610mm dia (un stretched), having minimum 50 Nos rounds per 6 metre length (before stretching), fixed on up to 5 m height of wall with ‘Y’ shaped angle iron brackets, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, with reinforced barbed tape (R.B.T.)/ spring core (2.5mm thick) wire of high tensile strength of 165 kg/sq.cm with tape (0.52mm thick) and weight 43.478 gm/m complete all as specified and as directed.Note: (i) Angle iron supports shall be measured and paid separately |
| 28 | S&F SS 304 Gde stainless steel bright finished letters of size 20cm width & 30cm height, 25mm thick projected letters made of 2mm thick SS sheet complete fixed to granite lining with necessary grouting etc complete all as directed. |
| 29 | M&L for ACP board for displaying 3D channel letters with MS frame of 38mmX38mm box structure, fabricating, welding, grinding, with 4mm thick silver grey colour ACP sheet (alloy grade 315 H14 PVDF coating for anti fungal and anti bacterial properties) covering all four sides of the board along with MS angle iron 50x50x6mm, anchor fasteners, bolts with all necessary fittings & fixtures complete for finished item of work all as directed. |
| 30 | S&F 100mm long SS butt hinges, heavy duty complete all as directed. |
| 31 | M&L for providing roof treatment by priming the surface with bituminous primer @ 0.1 kg/sq.m, over which laying APP based polymeric membrane minimum weighing 3kg/sq.m and minimum 3mm thick reinforced with polyester non woven fabric (wt. not less than 150gms/sq.m) by forced application, over which applyingindustrial bitumen 85/25 at the rate of 1.2kg/sq.m and finally applying two coat of bituminous aluminium paint complete all as directed. |
| 32 | M&L for Boring for Bored cast -in-situ piles of 450mm dia in any strata except hard rock using DMC method (Direct mud circulation) and getting out and disposal of spoil to a place out side MD land complete all as specified and as directed. |
| 33 | Carrying out initial load testing on 450mm dia piles of following testall as per IS complete all as specified and as directed including necessary anchoring and support piles of suitable load/size to be casted as required: |
| 34 | A) Compression test (Vertical load test) |
| 35 | B) Pull out test |
| 36 | C) Lateral test |
| 37 | Carrying out routine load testing on 450mm dia piles of following testall as per IS complete all as specified and as directed: |
| 38 | A) Compression test (Vertical load test) |
| 39 | B) Pull out test |
| 40 | C) Lateral test |
| 41 | Carrying out non destructive pile integrity testing on 450mm dia piles all as per IS-14893 complete all as specified and as directed. |