Tender For Electrical Renovation Of Food Corporation Of India Divisional Office Patiala Inside Fsd Patiala Premises.; 1 DISTRIBUTION BOARDS : Supplying , installation , testing , commissioning and fixingfollowing way,horizontal type three pole and neutral,sheet steel,MCB distribution board, 415 Volts, on surface/recess,complete with tinned copper busbar,neutral busbar,earth bar,din bar,interconnections, powder painted including earthing , numbering etc. as required. (But without MCB/RCCB/Isolator) 4 way (4+12), Double door 2 6way (4 + 18), Double door 3 Supplying and fixing 5 amps to 32 amps, rating, 240/415 volts, C Curve , miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single Pole 4 Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. asrequired 63Amp 5 CABLE TRAYS AND RACEWAYS : Supplying and installing following size of perforated pre-painted M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required. 300 mm width X 50 mm depth X 1.6 mm thickness 6 Supply & fixing of following size (GP RACEWAY- Fabricated from GP Sheet) race ways for electrical & LV wiring including neoprene gasket in joints, cutting the floor & jaming the race way / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work) as per site requirement. The thickness of raceway & partitions and covers shall be as per standard technical specification. 100 mm wide x 40 mm deep. 7 150 mm wide x 40 mm deep. 8 250 mm wide x 40 mm deep. 9 Supply & fixing of following size of Raceway Junction Box made out of GP Sheet for electrical & LV wiring including, cutting the floor & jaming the junction box / hanging in ceiling, supporting arrangement as approved by consultant / architect with all necssary hard ware (including civil work).(Junction box to be provided as per drawing/ as per site requirement & as per specification). The thickness of junction box shall be a as per thechnical specification. 150 mm wide x 40 mm deep. 10 200 mm wide x 40 mm deep. 11 300 mm wide x 40 mm deep. 12 CABLES, MAINS AND SUB MAINS : Supply of PVC insulated and PVC sheathed XPLE power cable of 1.1 KV grade armoured UG aluminium conductor cable conforming to IS 7098 part 1 with up-to-date amendment of the following size as required. 4C*16sqmm 13 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required. Upto 35 sq. mm (clamped with 1mm thick saddle) 14 POINT WIRING AND ACCESSORIES: Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. Group C 15 Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulatedcopper conductor single core cable etc. as required. Group A 16 Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire 17 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire 18 Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. 19 Wiring for light/ power plug with 4X4 sq. mm FRLS PVCinsulated copper conductor single core cable in surface/ recessed medium class PVC conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required 20 Supplying and drawing following sizes of FRLS PVC insulatedcopper conductor, single core cable in the existing surface/recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm 21 Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 1 run of cable 22 2 run of cable 23 3 run of cable 24 Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6 amps switch 25 15/16 amps switch 26 3 pin 5/6 amp socket outlet 27 6 pin 15/16 amp socket outlet 28 Telephone Socket 29 TV antenna socket outlet 30 Bell push 31 Supplying and fixing offollowing modular RJ-45 CAT-6 i/o socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 32 Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm) 33 3 Module (100mmX75mm) 34 6 Module (200mmX75mm) 35 12 Module (200mmX150mm}) 36 LIGHT FIXTURES AND FANS: SITC of 12 watt 2ft LED extruded aluminium batten with 12000lm output and 6500K colour temperature with electronic LED driver complete with all accessories etc. as reqd. 37 SITC of 36 watt LED 2ft X 2ft Panel recess mounting luminaire with electronic driver, soft-light and glare free symmetrical illumination suitable for mounting with ceiling complete with all accessories etc. as reqd. 38 SITC of 36 watt pendant type LED aluminum extruded housing in white/black powder coated finish and ABS end caps, opal diffuser for glare free symmetric light distribution with electronic LED driver and suspended with height adjustable suspension kit complete with all accessories etc. as reqd. 39 Supply,Installation Testing Commissioning of following sizes of Air exhaust fan 200mm sweep or equivalent suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. 40 Supply, Erection and testing of following sizes of Wall Fan400mm or equivalent suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. 41 Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. 42 EARTHING SYSTEM: Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. (but without charcoal/ coke and salt ) as required. 43 EARTHING STRIP G.I. Earthing Strip/Wire: Supply, installation, testing & commissioning of following sizes of G.I. strip/wire clamped to walls, cable trays, bus ducts, cables in recess or surface etc for equipment / system/ lighting protection earthing complete as required including inter connection between length at joints, all fixing accessories saddles, clamps etc. and other fixing hardware material as required for proper installation. 25 x 5 mm GI strip on surface or in recess for connection etc as required 44 6 SWG GI wire on surface or in recess for loop earth etc as required 45 LIGHTING CONDUCTOR : Providing and fixing of lightning conductor finial, made of 25 mm dia 300 mm long, G.I. tube, having single prong at top, with 85 mm dia 6 mm thick G.I. base plate including holes etc. complete as required. 46 Jointing copper / G.I. tape (with another copper/ G | tape, base of the finial or any other metallic object) by riveting / nut bolting/ sweating and soldering etc as required. 47 Sub Head VI - MV Panel S/I/T/C S/I/T/C of floor mounted cubical panel board fabricated 14 SWG CRCA sheet of approx. size 1.5mtr X 1.5mtr X 0.40mtr deep with provision of vertical adopter box on both sides & cubical boxes for fixing MCCB of various ratiing , the vertical bus bar of 4 strip Al. 600 mm long , 200 Amp. interconnections with copper conductor cable with suitable size of thimbles,lungs etc. & powder coated as required I/c P/f following mounting & placing the panel on a stand 60 cm above the ground fabricated with channel iron (100 X 40 mm) /angle iron (50x50x6 mm) i/c sheet covering with 16 SWG sheet etc. as required including the following items :- MCCB 4 pole 200 AmpBreaking cap. 35 KA (For Main) - 1No. MCCB T.P. 100 Amp, 16 KA - 4 No. MCCB T.P. 63 Amp16 KA- 3 No. Voltmetrer & selectors switches, Ammeter,CTS & PTS (with HRC fuse )- 1 SetIndicators with toggle switches- 3 Set 48 FIRE ALARM: MULTI HEAT/SMOKE DETECTORS : Supplying, installation, testing & commissioning of intelligent analog addressable photothermal detector complete with mounting base complete as required. 49 MANUAL CALL POINT: Supplying, installation, testing & commissioning of addressable manual call point complete as required. 50 Phone: Supplying, installation, testing & commissioning of fire fighter telephone handset complete as required. 51 CABLE: Supplying & laying of 2x1.5 sqmm fire survival armoured cable, 600/1000V rated with annealed copper conductor having glass mica fire barrier tape covered by an extruded layer of Cross Linkable Ethylene Propylene Rubber (EPR) insulation and LSZH inner bedding, steel wire armouring & LSZH outer sheath complete as required. 52 FIRE ALARM CONTROL PANEL: Supplying, installation, testing and commissioning of micro processor based intelligent addressable main fire alarm panel, centralprocessing unit with the following loop modules and capable of supporting not less than 240 devices (including detectors) and minimum 120 detectors per loop and loop length up to 2 km, network communication card, minimum 320 character graphics/ LCD display with touch screen or other keypad and minimum 4000 events history log in the non volatile memory (EPROM), power supply unit (230 + 5 % V, 50 hz), 48 hrs back-up with 24 volt sealed maintenance free batteries with automatic charger. The panel shall have facility to connect printer to printout log and facility to have seamless integration with analog/digital voice evacuation system (which is part of the schedule of work under SH: PA System) and shall be complete with all accessories . The panel shall be compatible for IBMS system with open protocol BACnet/ Modbus over IP complete as per specifications. Two loop 53 PUBLIC ADDRESS SYSTEM : Supplying, installation, testing & commissioning of 6 zone, voice alarm controller with USB, MP3 player (including 6 zone button paging station) with seamless integration facility with main fire alarm panel for voice evacuation complete as required. 54 Supplying, installation, testing & commissioning of 1.5/3/6W metal box ceiling/wall speakers complete as required. 55 Supplying and drawing of cable Fire Retardant PVC insulated copper conductor cable in the existing surface / recessed steel conduit of following pairs, cores and size including connections and interconnections etc. as required. speaker cable Single pair, 2-core, 1.5 sqmm 56 Credit Items : Less creditfor dismantaled old damaged metal scrap 57 Less credit for dismantled old damaged PVC insulated Al wire including transportation and disposal of the same from the site. 58 Less credit for dismantled old damaged PVC insulated Copper wire including transportation and disposal of the same from the site.