Tender For Maintenance And Repair Works At Samba And Kathua District For The Financial Year2025-26; 1 ALL items prescribein the JKSOR-2022/DSR(E&M)2022 as necessity at site 2 Non Scheduled Items900 mm sweep 3 Non Scheduled Items1200 mm sweep 4 Non Scheduled Items 1400 mm sweep 5 Non Scheduled Items 1200 mm sweep Decorative Fan as approved site engineer 6 Non Scheduled Items 1200 mm sweep Aero Dynamic type (Silent) 7 Supplying & fixing of Pedestal Fan 400Pedestal Fan 8 Supplying & fixing of Pedestal Fan 400Pedestal Fan With Remote 9 Supplying and fixing of 400 mm sweep wall mounting fan (oscillating type)on wall with necessary connection as required. 10 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.225 mm / 9 sweep exhaust fan 11 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.300mm/12 sweep exhust fan 12 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.380mm/15 Heavy duty 13 Supplying and fixing of following sizes Transair exhaust fan with metal blade complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.450 mm/18 Heavy duty 14 Supplying and fixing of following sizes exhaust fan with PVC blade & Louvers complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.200mm / 8 sweep exhaust fan 15 Supplying and fixing of following sizes exhaust fan with PVC blade & Louvers complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.225 mm / 9 sweep exhaust fan 16 Supplying and fixing of following sizes exhaust fan with PVC blade & Louvers complete set on existing holes on wall with necessary connection from ceiling rose to fan using 2 core flexible copper wire.300mm/12 sweep exhust fan 17 Supplying and fixing of fan hook (U hook) on celiling with 2 nos. of anchor fastener on both ends with necessary bolts andnuts and mansonry work as required. 18 Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan.1-0 19 Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan. 1-6 20 Supplying and fixing of following sizes extra down rod with twin core flexible copper wire for ceiling fan.2-0 21 Making round shaped hole on the wall including supply and fixing of necessary cement concrete collar to suit 300 mm heavy duty exhaust fan and finishing the wall to make good. 22 Supplying and fixing of 25 mm thick ply wood with round shaping at the center to fix exhaust fan on ventilator with required accessories. 23 Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 3 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall bepre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded withBEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendlyGI Electrode Earthing should be maintinance free and does not requireregular manual addition of water . The earthing pit should be covered with PVC cover. 24 Supply, installation, testing & commissioning of GI Electrode Earthing with 50mm dia and 2 meter length, with 3mm thick the electrode should be hot-dip galvinised. The GI Electrode shall bepre-filled with Cristaline Conductive Materila (CCM). The GI electrode shall be surrounded withBEE MOIST compound to provide maximum contact betwen the electrode and compound should be eco-friendlyGI Electrode Earthing should be maintinance free and does not requireregular manual addition of water . The earthing pit should be covered with PVC cover. 25 Providing and fixing 20 mm X 3 mm G.I. strip on surface or in recess for connections etc. as required. 26 Supply, installation, testing & commissioning of maintenance free copper earthing system with 3 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. 27 Supply, installation, testing & commissioning of maintenance free copper earthing system with 2 mtrs. Electrode 40 mm dia with minium 2mm thick and does not require manual additional of water. The electrode shall be pre-filled with hygroscopic powder and provided with suitable breathing and leaching ports at the ends. the electrode shall be surrounded by suitable powdered form of BEE MOIST so as to provide maximum contact between the electrode and the compund. The compound should be eco-friendly The earthing pit should be covered with PVC cover. 28 Providing and fixing of 20 mm x 3mm copper strip on surface or in recess for connections etc. as required. 29 Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required. 30 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire.20/22 watt LED 4 feet tube light fitting/fixture Aluminium housing with 2000 Lumens and min lumens efficiency100 lumens/watt P.F >.90. 31 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire.28watt LED 4 feet tube light fitting/fixture Aluminium housing with 2800 Lumens and min lumens efficiency100 lumens/watt P.F >.90. 32 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire.36 watt LED 4 feet tube light fitting/fixture Aluminium housing with 3600 Lumens and min lumens efficiency100 lumens/watt P.F >.90. 33 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire. 34 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire.LED Batten Tube fitting 600mm size 10/11 watt Aluminium housing with 1000 Lumens and min lumens efficiency100 lumens/watt P.F >.90 . 35 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire. 600 mm x 600 mm size recessed mounted LED Luminaries 36 watt. havingminimum 3600 Lumens with minimum lumens efficiency 110 Lumens/watt (Commercial type) 36 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire.Mirror light LED fitting with 9/11W LED lamp 37 Supplying and fixing of Following light fitting with lamps on ceiling/ wall with necessary connection from ceiling rose to fitting by twin core flexible copper wire.Water tight bulk head LED fitting with 10 watt LED lamp. 38 Providing and fixing of LED Lamp.0.5 w 39 Providing and fixing of LED Lamp.5W 40 Providing and fixing of LED Lamp.9W 41 Providing and fixing of LED Lamp.12W 42 Providing and fixing of LED Lamp.15W 43 Providing and fixing of LED Lamp.18W 44 Providing and fixing of LED Lamp.20W 45 Providing and fixing of LED Lamp.9 watt (warm) 46 Providing and fixing of LED Lamp.9 watt (White) 47 Providing and fixing of LED Lamp.12 watt (warm) 48 Providing and fixing of LED Lamp.12 watt (White) 49 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 45 watt 50 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 50 watt 51 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 70 watt 52 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 90 watt 53 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 100 watt 54 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 120 watt 55 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 45 watt 56 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 50 watt 57 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 70 watt 58 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 90 watt 59 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 100 watt 60 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 120 watt 61 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 200 watt 62 Supply and fixing of following LED type Street lights including GI pipe bracket and connections etc as required. 200 watt WITH PC LENS 63 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.5 watt. 64 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.7 watt. 65 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.9 watt. 66 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.12 watt. 67 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.15 watt. 68 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.18 watt. 69 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.20 watt. 70 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.28 watt. 71 Supplying and installation of recessed/surface mounted slim circular/square type down lighter of following rating.30 watt. 72 Providing & fixing of following accessories. 5/6 Amp. 3 pinTop 73 Providing & fixing of following accessories. 5/6 Amp 2 pin Top 74 Providing & fixing of following accessories. 15/16 Amp 3 pin top 75 Providing & fixing of following accessories. Insulation Tape (ISI brand) 76 Providing & fixing of following accessories. Electronic Step Type fan Regular (Piano type) 77 Providing & fixing of following accessories. Celing Rose 78 Providing & fixing of following accessories. 2.2/3/3.5 mfd fan condenser 79 Providing & fixing of following accessories. Brass batten/ angle holder including (Modular)connection etc. as required. 80 Providing & fixing of following accessories. Dimmer Type Regulator (with numbering) 81 Providing & fixing of following accessories. 5/6 Amp combined 82 Providing & fixing of following accessories. 15/16 Amp combined 83 Toolkit comprises of plier, screw driver and Phase tester 84 Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge. 900mm /1200mm / 1400mm sweep AC ceiling fan 85 Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge.upto 300mm sweep exchaust fan 86 Rewinding of the following fans using enameled copper wire of required gauage, varnishing oiling greasing etc. The workmanship shall up to the satisfaction of the Engineer in charge.Servicing of the Geyser etc. as required. 87 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed)Heating Element 88 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed)Thermostat with control 89 Supplying and replacement of the suitable size and rating of the following in the storage water heater and making the geyser in good working condition. (Make as per the gyser installed)Replacement of Assembly complete job 90 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole upto 32 amp. 91 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole40 amp. 92 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral upto 32 amp. 93 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole and neutral32 amp. (Modular) 94 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole upto 32 amp. 95 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole40 amp. 96 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole upto 32 amp. 97 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole 40 amp. 98 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple Pole and netural upto 32 amp. 99 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPN 40 Amp 100 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPN 63 Amp 101 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. SPN 100 Amp 102 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TPN 40 Amp 103 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TPN 63 Amp 104 Supplying and fixing of following rating 240/415 volts C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. TPN 100 Amp 105 Supplying and fixing single pole blanking plate in the existing MCB DB Complete etc. as required 106 Supplying, installation, testing and commissioning of Cubical type Indoor/OutdoorLT Panel Board Suitable for 415 V 3 Phase 4 wire 50 Hz AC supply system with provision for housing incomers, Out Going, COS, Bus Bars etc. as required but excluding the cost of MCCBs, Bus Bars and Change over as per the following Description (IP:42) General Floor Distribution Panel. The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A drawing wiring diagrams, single line diagram before start of fabrication of LT panel Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating. Thepanel Builder shall be CPRI/ERDA/ANY NABL ACCREDITED LAB approved. 107 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)63 Amp, 25 KA, FP MCCB ICU = 100% ICS 108 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)100 Amp, 30 KA, FP MCCB ICU = 100% ICS 109 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)125 Amp, 36KA, FP MCCB ICU = 100% ICS 110 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)160 Amp, 36 KA, FP MCCB ICU = 100% ICS 111 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)200 Amp, 36 KA, FP MCCB ICU = 100% ICS 112 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)250 Amp, 36KA, FP MCCB ICU = 100% ICS 113 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)320 Amp, 36 KA, FP MCCB ICU = 100% ICS 114 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)400 Amp, 50 KA, FP MCCB ICU = 100% ICS 115 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)630 Amp, 50 KA, FP MCCB ICU = 100% ICS 116 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)Electrical Rubber Mathaving thickness 6mm and width 1 Mtr 117 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)ON Load Change Over Switch FP 100 amp. (Front operated) 118 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)ON Load Change Over Switch FP 200 amp. (Front operated) 119 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)ON Load Change Over Switch FP 250 amp. (Front operated) 120 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)Aluminium Bus Bar 200 Amp set of 4 strips 121 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)Aluminium Bus Bar 300 Amp set of 4 strips 122 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)Aluminium Bus Bar 400 Amp set of 4 strips 123 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)Aluminium Bus Bar 500 Ampset of 4 strips 124 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)Aluminium Bus Bar 800 Ampset of 4 strips 125 Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. (Thermal Magnetic type,Adjustable type)Digital Metering devices, comprising of Voltmeter, Ammeter, Selector Switch, Indicating Lamp, CT Set etc. 126 Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG. 127 Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG.Wall Fan 128 Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG.Ceiling Fan 129 Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG.Exhaust Fan 130 Providing and fixing of PCB in wall fans (Remote control type) having sweep 400 mm of make Havells/ CG.Pedestal Fan 131 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 10 sq. mm 2 core 132 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 16sq. mm 2 core 133 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 25 sq. mm 2 core 134 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 35 sq. mm 2 core 135 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 10 sq. mm 4 core 136 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 16 sq. mm 4 core 137 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 25 sq. mm 3.5 core 138 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 35 sq. mm 3.5 core 139 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 50 sq. mm 3.5 core 140 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 70 sq. mm 3.5 core 141 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 95 sq. mm 3.5 core 142 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 120 sq. mm 3.5 core 143 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 150 sq. mm 3.5 core 144 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 185 sq. mm 3.5 core 145 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 240 sq. mm 3.5 core 146 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 300 sq. mm 3.5 core 147 Supplying & laying ofPVC insulated and PVC sheathed/ XLPE Aluminium power cable of 1.1 KV grade of following size on surfaces/ direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. (Armoured cable) 400 sq. mm 3.5 core 148 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured.6 sq. mm 149 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured.10 sq. mm 150 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured.16 sq.mm 151 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured.25 sq.mm 152 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured. 35 sq.mm 153 Supplying and fixing of twin core aluminium cable all along the wall surface unarmoured.Flexible Twin core cable whiter wire 154 Supplying & Drawing of Co- axial TV cable RG-6 grade, 0.7 mm solid copper conductor. 155 Supplying & Drawing of UTP 4 point Cat-6 cable (1 run cable) (D-Link, Schneider, Systimax) 156 Supplying & fixing of following Remote BellsBell controlled by Single Remote with minimum 15 mtrs range 157 Supplying & fixing of following Remote BellsCall bell / Buzzer, Single phase with minimum15 mtrs range 158 Supplying & fixing of following Remote BellsBell controlled by double remote with minimum 15 mtrs range 159 Supplying & fixing of following Remote BellsDing Dong Bell 160 Supplying & fixing of following PVC Gang Box.One way 161 Supplying & fixing of following PVC Gang Box.Two way 162 Supplying & fixing of following PVC Gang Box.1 + 1 way 163 Supplying & fixing of following PVC Gang Box.3 + 1 way 164 Supplying & fixing of following PVC Gang Box.4 + 1 way 165 Supplying & fixing of following PVC Gang Box.6 + 1 way 166 Supplying & fixing of following PVC Gang Box.1 + 1 way (Power) 167 Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten). Casing Caping 1 168 Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten). Casing Caping 3/4 169 Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten). 4 Deep Box 170 Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten). 5 Fan Box 171 Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten). Conceeled Box 172 Supplying & fixing of Electrical Accessories PVC Casing and Caping (Batten). Junction Box (Metal) 173 Supplying and fixing ofPhenolic Laminated Sheet 9 x 11including cutting the space for switches/socket etc. 174 Supplying and fixing of Phenolic Laminated Sheet 9 x 6 including cutting the space for switches/socket etc. 175 Supplying and fixing of Phenolic Laminated Sheet 4 x 4 including cutting the space for switches/socket etc. 176 Supplying and fixing of Phenolic Laminated Sheet 11 x 13 including cutting the space for switches/socket etc. 177 Supplying and fixing of Phenolic Laminated Sheet 6 x 3 including cutting the space for switches/socket etc. 178 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)0.50 HP 179 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)0.75 HP 180 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)1 HP 181 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)3 HP 3 phase motor 182 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)5 HP 3 phase motor 183 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding) 3 phase motor Starter for 3 HP to 7 HP Motor 184 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)Rewinding of 3 phase (7 HP) motor for water lifting (Copper winding) 185 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)Rewinding of 3 phase (5 HP) motor for water lifting (Copper winding) 186 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)Rewinding of 3 phase (3HP) motor for water lifting (Copper winding) 187 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)Rewinding of 1 phase (0.5 HP) motor for water lifting (Copper winding) 188 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)Rewinding of 1 phase (1 HP) motor for water lifting (Copper winding) 189 Supply and fixing of single phase of following rating self priming for pumping water including connections etc as required.(Copper winding)Rewinding of 1 phase (2 HP) motor for water lifting (Copper winding) 190 Dismentalling of Ceiling fan/Wall fan/Exhaust fan and re-fixing the same after repair. 191 Repair of fan by way of replacing damaged bearing, bushes etc as required. 192 Supply of following items Invertor Sinewave 850 VA 193 Supply of following items Invertor Sinewave 1050 VA 194 Supply of following items Invertor Sinewave 1650 VA 195 Supply of following items Invertor Sinewave 2000 VA 196 Supplying & fixing of Battery 12 Volt. Tubular 150 AH with36 months Guarantee Note.:- (Rs.2500 /Battery has to be deduct for the scrap of old batteries (150 AH)from allotted rate in case of replacement of battery is out of warranty period. 197 Supplying & fixing of PVC Trolley for housing single battery inverter 198 Supplying & fixing of PVC Trolley for housing double battery inverter 199 Repair to PCB of inverter 850 VAto 1050 VA 200 Repair to PCB of inverter 1550 VA to 2000 VA 201 Replacement of PCB of inverter 850 VAto 1050 VA 202 Repair of Automatic Voltage Stabilizer by way of copper winding etc as required.upto 3 KVA 203 Repair of Automatic Voltage Stabilizer by way of copper winding etc as required.Above 3KVA to 5 KVA 204 Supply Installation Testing & Commissioning of 3 Core Power Cable 1.5 sqmm. Make: Finolex/Polycab/Havells 205 Supplying, installation, testing and commissioning of 1 KVA offlineUPS with minimum backup of 20 minutes and having over load, short circuit protection. 206 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required.5/6 Ltr 207 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required.15 Ltr 208 Supplying, fixing & commissioning of Storage Water Heater (Geyser)of following capacity along with PVC Pipes etc as required.25 Ltr 209 Supply offollowing electrical HeaterSingle Rod 210 Supply offollowing electrical HeaterDouble Rod 211 Supply offollowing electrical HeaterThree Rod 212 Supply offollowing electrical HeaterCooking Heater Controlled by Switch/Regulator 213 Supply offollowing electrical HeaterHeating Blower 214 Supply offollowing electrical HeaterRod for Pillar Heater Gopi 215 Supply of following electrical appliances.Mixer Grinder 216 Supply of following electrical appliances. Electric Fly Catcher 217 Supply of following electrical appliances.Electronic Weighing Machine 218 Supply of following electrical appliances. 12 V 7.0 AH sealed rechargeable batteryfor lift 219 Refilling of fire extinguisher ABC Type (MAP 90) 06 Kg Capacity. 220 Supplying, installation, testing and commissioning of 150/150 Liters of water Cooler having full stainless steel body, cooling capacity 150ltr/hour and storage capacity 150 ltralongwith PVC connecting pipes as required. . 221 Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.(RO + UV + UF mineral control with TDS control ) 222 Supplying, installation, testing and commissioning of following type of water purifiers alongwith PVC connecting pipes as required.UV purifier for water cooler 223 REPLACEMENT OF WATER PURIFIER CHOKED CANDLES (RO + UV + UF) 224 REPLACEMENT OF WATER PURIFIER CANDLES OF WATER COLLER 225 SERVICING OF WATER PURIFIER CHOKED CANDLES (RO + UV + UF) 226 SERVICING OF WATER PURIFIER CANDLES OF WATER COLLER 227 Supplying, installation, testing and commissioning of1.5 Ton Inverter type SplitACs (copper) (3 star) Hot/ Cold (all weather) type of minimum capacity following sizes as detailed below. Each unit must provide cooling & dehumidification, be operatable via remote control, operate at 220-240 V AC supply with latest in vogue features.Repairs made to wall whereever required.Warrantee.:-a). Warrantee shall be provided for 12 month from the date of installations. b). The compressor shall be warranted for 5 years from the date of installation. 228 Supplying, Installation, Testing & Commissioning of following capacity automatic voltage stabilzer copper wound wall mounted, single phase with range of 90-240 V along with wall mounting brackets & fitting. The job includes repairing the walls where necessary.Warrantee.:- 2 Years from the date of installation.4 KVA 229 Supplying & fixing of M.S Wall Stand duly powder coated for outdoor unit of Split AC 230 Supplying & fixing of drain pipe for indoor unit 1 231 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 1.5 Ton AC 232 Extra length of copper pipe for outdoor unit and suitable size copper cable of required size for 2.0 Ton AC 233 provision for Gas Charging of 1.5 / 2.0 Ton split / window type AC including valve etc if required 234 Providing and fixing Copper pipes set for 1.5 ton Split AC Along with suitable copper cable including brazing as required 235 Providing and fixing Copper pipes set for 2.0ton Split AC Along with suitable copper cable including brazing as required 236 Servicing of Split AC of all capacities 237 Servicing of window AC of all capacities 238 Servicing of tower AC of all capacities 239 replacement of defective capacitor for 1.5 / 2.0 tonne split / window AC 240 Supply erection testing and commissioning compressor suitable for 150 ltr water coller with gas charging and other required accessories to get water coller workable 241 Supply erection testing and commissioning compressor suitable for 40/80 ltr water coller with gas charging and other required accessories to get water coller workable 242 Provision for Gas charging of water coller 150 ltr 243 Provision for Gas charging of water coller 40/80 ltr 244 Cleaning of water tank 500/1000 ltr with suitable chemical 245 P/F of STARTER FOR 2HP borewell submersible pump including teting ,labour engaged for removing unservicebale STARTER 246 P/F of 2HP borewell submersible pump including teting ,labour engaged for removing unservicebale pump. 247 P/F of 30HP starter including testing complete job . 248 Labour 249 Plumber 250 Electrician 251 Carpenter 252 Black smith 253 Providing and fixing ACP main board 3mm thickness on 1 x 1 inch tubular frame with writing of Name of stadium etc as per direction of engineer incharge 254 Providing and Fixing PVC Wall Panneling 1 mm thick with necessary fittings 255 Providing and fixing tiled 8 mm th. False Ceiling tiles of specified materials of size595 x 595mm in the existing ceiling Grid 256 Providing and fixing tiled Mineral Fibre False Ceilingtiles of specified materials of size595 x 595mm in the existing ceiling Grid 257 LETTERING ON HONOUR BOARD 258 Acrylic NAME PLATE WITH LETTERING ON BOTH SIDE 259 Providing and Fixing PVC SHEET 4 MM TH 260 Supply & Plantation of Ornamental plants incl. cleaning of weeds,Plantation, adding farm yard mannure, good earth as where required, watering & maintenance of the plants for 60 days andcarriages all complete job.Payment on account of only those plant shall be made which shall survive for 60 daysMarry gold 261 Supply & Plantation of Ornamental plants incl. cleaning of weeds,Plantation, adding farm yard mannure, good earth as where required, watering & maintenance of the plants for 60 days andcarriages all complete job.Payment on account of only those plant shall be made which shall survive for 60 dayschrysanthemum (Guldaudi ) plant 262 Supply & Plantation of Ornamental plants incl. cleaning of weeds,Plantation, adding farm yard mannure, good earth as where required, watering & maintenance of the plants for 60 days andcarriages all complete job.Payment on account of only those plant shall be made which shall survive for 60 daysSalvia 263 Supply & Plantation of Ornamental plants incl. cleaning of weeds,Plantation, adding farm yard mannure, good earth as where required, watering & maintenance of the plants for 60 days andcarriages all complete job.Payment on account of only those plant shall be made which shall survive for 60 daysspider plant 264 filling of good earth including diging, loading, unloading, royality, carriage & spreading in proper lines and grades and consolidation with power road roller complete as per direction of Engineer Incharge 265 Providing and Fixing Horizontal zebra Blindes 266 Providing and Fixing Vertical Blindes 267 Providing & fixing of urinal batteries in sensor urinals set of 4 batteries 268 Providing & fixing Bitumen Torchshield water proffing including bitumen primer complete job 269 Providing and laying of Gabion of mechanically woven, double twisted hexagonal wire mesh Gabion Type: Zinc coated mesh type 100 mm x 100mm, woven diagionally. Mesh wire dia 2.70, salvage wire dia 3.40 mm lacing wire dia 2.20 mm of GI wire including all leads lifts and carriages and cost of Stone and Gabion wire crates. The gabions shall have partions made of same material and each compartment shall be of size 1.2m x 1.00m (RATE INCLUDING COST OF STONE, GABION BUT EXCLUDING CARRIAGE OF STONE)