}

Limited Tender Bid For Contractor For Renovation Work At Jamalpur Branch Of Union Bank Of India, jamalpur-Haryana

Union Bank Of India has published Limited Tender Bid For Contractor For Renovation Work At Jamalpur Branch Of Union Bank Of India. Submission Date for this Tender is 16-07-2025. Furnishing Work Tenders in jamalpur Haryana. Bidders can get complete Tender details and download the document.




Tender Notice

50046188
Limited Tender Bid For Contractor For Renovation Work At Jamalpur Branch Of Union Bank Of India
Tender
Indian
Haryana
Jamalpur
16-07-2025

Tender Documents

Tender Details

Limited Tender Bid For Contractor For Renovation Work At Jamalpur Branch Of Union Bank Of India; 1 TOTAL CIVIL WORK 2 FURNISHING WORK 3 Providing and fixing in position Full Height Partition with GI framework of 600 X 600 mm grid (horizontally and vertically) comprising of 50 mm X 50 mm heavy duty GI (C)-Sections corrugated of 1.5 mm minimum thickness with 12 mm thick moisture resistant MDF (interior grade) on both sides finished with 1 mm thick laminate on both sides in approved shade with groove pattern. Item includes provision of grooves in desired pattern, finishing the grooves with woodtech filler (asian paints/ nerolac paints) of specified shade. The rate includes provisionof extra framework for skirting, niches and making cutouts for electrical switch plates, switch boxes, light fittings, making provision for laying conduits as per drawings & directions. 4 Measurement of height shall be taken from finished floor level up to the level of false ceiling.In case of false ceiling, the vertical GI members to be fixed to RCC ceiling or to be joined with False ceiling framing with secrews but the area of partition payable will be below the false ceiling only.In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only, nothing extra for designing and provision of niches and vertical sections. 5 Providing and fixing in position Low Height Partition upto height of 1200 mm supported with GI framework of 600 X 600 mm grid (horizontally and vertically) comprising of 50 mm X 50 mm heavy duty GI (C)-Sections corrugated of 1.5 mm minimum thickness with 12 mm thick moisture resistant MDF (interior grade) on both sides finished with 1 mm thick laminate on both sides in approved shade with groove pattern. 10 mm thick acid wash glass is to be fixed with SS clamp at the exposed edges of the partition. Item includes 2nd class teakwood / pine wood beading corner chamfered of size 75 X 25 mm. All exposed woodwork to be high gloss melamine polished after using proper masking tapes while polishing to prevent any damage to laminate 6 Measurement of height shall be taken from finished floor level.In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only, nothing extra for designing and provision of niches and vertical sections. 7 Providing and fixing Partition made up of Aluminium Composite Panel (ACP) sheets with framing of aluminium tube sections of min. 2” x 1” and 20 gauge at a spacing of 2’ center to center both ways. ACP to be of approved shade in 2’ width panels or distributed equally. ACP sheets to be fixed to the frame with 3M make adhesive along with mirror screws. Joints to be finished with silicon based sealant. ACP sheets to be min. 3mm thick with aluminum foil thickness to be min. 0.25 mm on both sides. Item also includes providing a door of size 3’ x 7’ made up of Aluminium Composite Panel (ACP) sheets with framing of aluminium tube sections as specified above along with Godrej make heavy duty lock, 3 numbers 3” SS hinges, handles etc. complete. 8 Measurement of height shall be taken from finished floor level.In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only, nothing extra for designing and provision of niches and vertical sections. 9 Providing and fixing full glazed glass partition including door with 12 mm thick Toughened Glass fixed to the floor / wall / flase ceiling / partition / panelling with patch fittings moving on double action hydraulic heavy duty floor spring (Hettich/Ozone/Dorma) and pivot on top. The glass is to be machine cut &the surface polished, floor spring to be properly embedded inside the floor spring after cutting and making good the floor and finally covering with Stainless Steel cover plate, The doors are to be provided with Lock fitted to the glass, 600 mm long & 25 mm dia Stainless Steel door handles along with all associated patch fittings (Hettich/Dorma/Godrej) 10 Measurement of height shall be taken from finished floor level up to the finished glass surface.In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only. Glass shall be fixed in 2 parts where ever single piece glass is not avaialble with all fixing accessories with no extra cost 11 Fixed Glass Partition 12 Frameless Door 13 Providing & fixing Glazed Door 30 mm thick flush door with10 mm teak wood lipping on all sides finished with 1.0 mm thick laminate of approved shade fixed on both sides and provision of vision panel of size 150 mm X 1500 mm having 12 mm thick float glass fixed with 10 mm thick teakwood lipping.The door is to be fixed to wooden frame of 2nd class teakwood/sal woodmembers of size 75 x 75 mm and the frames is to be fixed with partition / wall with holdfast / GI fastner. The door is to be provided with cylindrical lock,door closer, spring loaded SS Door stopper,heavy-duty SS ball bearing butt hinges 100 x 5.5 mm (4 Nos. per shutter) with screws. All wood surfaces to be treated with 2 coats of Fire retardant paint Viper of navair/equivalent and finally finished with malamine polish complete to the satisfaction of Banks Engineer. 14 Measurement of height shall be taken from finished floor level up to the outer edge of wooden frame and width shall be from outer edge of wooden frame to outer edge of wooden frame..In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only. 15 Providing & fixing Solid Flush Door 30 mm thick flush door with10 mm teak wood lipping on all sides finished with 1.0 mm thick laminate of approved shade fixed on both sides.The door is to be fixed to wooden frame of 2nd class teakwood/sal woodmembers of size 75 x 75 mm and the frames is to be fixed with partition / wall with holdfast / GI fastner. The door is to be provided with 12 x 200 mm SS Aldrop, 150 mm SS handles (2 nos), 200 mm long SS tower bolt,door closer, spring loaded SS Door stopper,heavy-duty SS ball bearing butt hinges 100 x 5.5 mm (4 Nos. per shutter) AND with screws. All wood surfaces to be treated with 2 coats of Fire retardant paint Viper of navair/equivalent and finally finished with malamine polish complete to the satisfaction of Banks Engineer. 16 Measurement of height shall be taken from finished floor level up to the outer edge of wooden frame and width shall be from outer edge of wooden frame to outer edge of wooden frame..In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only. 17 Providing & fixing Single leaf Fire Rated Door of120 minutes or 2 hours fire rating of make TATA Pravesh/Equivalent as approved of overallsize 900x2100 mm. The product should carry 5 years warranty on manufacturing and powder coating. 18 Door Leaves constructed from 1.6 mm (12 SWG) thick Galvanized Iron Sheet (conform to IS 277), overall thickness of 46 mm and Rockwool/Mineral wool/Honeycomb craft paper used as in-fill material 19 The door frames are to constructed from 1.6 mm (12 SWG) thick skin pass Galvanised Iron Sheet (conform to IS 277) formed to single rebate profile of size with profile dimesnions 0.143 m x 0.058 m. 20 Vision glass of 6 mm clear float glass of size 0.2 m x 0.3 m 21 The door frame and door shutter are to be coated with Zinc Phosphate Stoving Primer and to be powder coated with epoxy polyester/pure polyester/polyurethane with minimum dry film thickness of 60-65 microns from both sides 22 Stainless Steel Ball bearing butt hinges 0.102 m x 0.076 m x 3 mm - 04 nos per shutter and mortise sash lock with lever handles, necessary hardwares for fitting complete 23 Measurement of height shall be taken from finished floor level up to the outer edge of GI frame and width shall be from outer edge of GI frame to outer edge of GI frame.In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only. 24 Providing and fixing Louvered Shutter Cabinet for main panel fabricated out of 18 mm thick Fire Retardant MDF (FRMDF) (conform to BS 476 : Part 7 Class 1) finsihed with putty and fire retardant paint from inside and 1 mm thick laminate of approved make & shade from outside. 25 The item to include powder coated MS louvers in both the shutters of the door of size - 300 mm x 1.2 m 26 The door is to be provided with 12 x 200 mm SS Aldrop, 150 mm SS handles (2 nos),auto closer hinges (3 Nos. per shutter) with necessary screws, harwares. 27 Front facia shall be measurement for payment. Measurement of height shall be taken from finished floor level up to the finished edge of the cabinet and width shall be from outer edge to outer edge of cabinet.In case of varying heights on either side of partition, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only. 28 SUB TOTAL : I : PARTITTIONS AND DOORS 29 PANELLING 30 Providing & fixing Panelling (Laminate) with frame work of 600 X 600 mm grid (horizontally and vertically) comprising of 50 mm X 50 mm heavy duty GI (C)-Sections corrugated of 1.5 mm minimum thickness with 12 mm thick moisture resistant MDF (interior grade) and 1.0 mm thk. laminate of approved shade. Paneling to have up to 3 Nos. of 50 mm high metallic decorative texture laminateband. Paneling to have 50x35mm teak wood moulding on edges. Panelling to have provision of extra frame work as necessary for skirting, coves and making cutouts for electrical switch plates, switch boxes, light fittingsas per directions and complete to the satisfaction of the Banks Engineer. 31 Measurement of height shall be taken from finished floor level up to the level of false ceiling.In case of false ceiling,area of panelling payable will be below the false ceiling only.In case of varying heights on either side of panelling, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only, nothing extra for designing and provision of niches and vertical sections. 32 Providing & fixing DesignerPanelling (/louvers panels / pvc puff panels) with frame work of 600 X 600 mm grid (horizontally and vertically) comprising of 50 mm X 50 mm heavy duty GI (C)-Sections corrugated of 1.5 mm minimum thickness with 12 mm thick moisture resistant MDF (interior grade) and lacquered glass of 6 mm thickness (PLANILAQUE®-saint Govin), of any colour with superior quality natual colour glass silicon / resine / Araldite and wooden beading support as per directions and complete to the satisfaction of the Banks Engineer. The edges of the glass panels are to be bevelled and rounded from all the sides. (Base Price of material to be used to be Rs. 200/ sq.ft. without taxes). 33 Measurement of height shall be taken from finished floor level up to the level of false ceiling.In case of false ceiling,area of panelling payable will be below the false ceiling only.In case of varying heights on either side of panelling, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only, nothing extra for designing and provision of niches and vertical sections. 34 Providing & fixing in position Aluminium Composite Paneling (ACP) with framing of aluminium tube sections of 38mmX25mm and 20 gauge at a spacing of 2 center to center both ways. ACP to be of shade as approved by Bank in 2 width panels or distributed equally. ACP sheets to be fixed to the frame with 3M make adhesive along with mirror screws . Joints to be finished with silicon based sealant. ACP sheets to be min. 3mm thick with aluminium foil thickness to be min. 0.25 mm on both sides. Item includes providing additional sections to fix indoor AC units which will be installed at the higher position. 35 Measurement of height shall be taken from finished floor level up to the level of false ceiling.In case of false ceiling,area of panelling payable will be below the false ceiling only.In case of varying heights on either side of panelling, average height shall be considered. Measurement shall be taken of the visible front surface (elevation - 2D surface) only, nothing extra for designing and provision of niches and vertical sections. 36 SUB TOTAL : II : PANELLING 37 FALSE CEILING 38 Item includes providing False Ceiling in plane, curve shape and design. Suspending system and frame work shall match layout of A.C. ducts / grills, electrical / fire protection wiring / fixtures, return air grills etc. Rate to include provision of extra frame work, necessary scaffolding needed due to layout of other utilities refered above and fixtures etc.(Measurement shall be taken of the plan area.Cove design and verticle sections shall be measured in sqm) 39 Providing and fixing Gypsum Board False Ceiling at all heights with INDIA GYPSUM ULTRA/approved make main ceiling sections at 1200 c/c and cross members at 450 c/c of INDIA GYPSUM/approved make . The grid work to be suspended from ceiling with hangers at every 1200 c/c in both directions. The Frame work to be as per manufacturers specifications. 12.5 mm thk. GYPBOARD/approved make to be screwerd to the frame. The board to be finished with filling the tapered edges of the board with jointing compound and finishing with paper tape of INDIA GYPSUM/approved make. The ceiling to be finished with a top coat (plastic emulsion paint with Velvet Touch of approved brand and manufacture to give an even shade: Two or more coats on new work with rollers/ spray) as per manufacturers specification along with provision of all necessary cut outs for electrical / air conditioning grills and necessary frame work including cove and curve designs etc. complete to the satisfaction of Banks Engineer. 40 Providing and fixing False Ceiling with Mineral Fibre Acoustic Ceiling Tiles of Armstrong/ USG/ Boral with MICROLOOK edges and having noise reduction properties laid on exposed grid system with 15mm wide Silhouette type T-section flanges of white colour, main runners spaced at 1200 mm c/c securely fixed to thesoffit of structure with approved hangers at 1200 mm maximum c/c. Flush fitting 1200 mm crossed tees to be interlocked between main runners at 600 mm c/c to form 1200 x 600 modules. 1200 mm cross tees to be crimped. 600 x 600 module to be formed by fixing 600 mm long flush fitting cross tees centrally between the 1200 cross tees. Ceiling tiles of Dune Premier of size 600 x 600 x 15 mm (thk.) to be placed in the grid. Rate to include making necessary cut-outs or openings for light fixtures, air conditioners and other utilities etc. complete to the satisfaction of Banks Engineer. 41 Providing and fixing plain non perforated metal sheet GI tilesGrid False Ceiling of size 600mm x 600mm having ceiling sections at 600 mm center to center both ways duly fixed with screws. The grid work to be suspended from ceiling with hangers at every 600 mm center to center in both directions.The framework to be as per manufacturer’s specifications. Item includes providing extra support for fixing light fixture complete to the satisfaction of Banks Engineer. 42 Providing and fixingCustomized Box curtain ceiling made up of Aluminium of 100x25x0.7mm thk , minimum 50micron epoxy powder coated fixed perpendicular t 0.7 G.I. box channel of size 38mm x 15mm by hexagonal bolt as per design.The framework to be as permanufacturer’s specifications. Item includes providing extra support for fixing light fixture complete to the satisfaction of Banks Engineer. 43 SUB TOTAL : III :FALSE CEILING 44 COUNTER/ TABLES/ WORKSTATIONS 45 Providing and fixing in position Tables with the foloowing specifications: 46 The working top to be fabricated with 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate and8 mm thick clear toughened glass with bevelled edges to be provided on top. Table top edgesto be 40 mm thk. finished with laminate. Ready made cable manager with matching hole in the top and glass is to be provided. 47 The front facia/front modesty panel shall be made from 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate.Part of the front facia shall be finished with Lacquered glass of 6 mm thickness (PLANILAQUE®-saint Govin), of any colour with superior quality natual colour glass silicon / resin / Araldite and wooden beading support as per the drawing 48 The side supports shall be made up from 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate. 49 The drawer unit shall be made from 12 mm thick Moisture Resistant Grade commercial ply finished with 1 mm laminate on exposed surfaces comprising of 3 Nos. of drawers upto 400 mm wide & 450 mm deep). The drawer are to be fixed on telescopic channel channels with 100 mm wide SS handles in matt finish and one multipurpose lock per drawer. 50 Telescopic CPU trolley with castors and readymade keyboard tray of size 600 x 270 mm fixed on telescopic channels of approved make shall be provided 51 The item to include 10 mm thick lipping/ teak patti to all edges and all exposed teakwood surfaces / wooden beading are to be finished with melamine polish shade matching with laminate colour 52 The inside surafces are to be finished with 0.8 mm white laminate 53 Footrest 75x50mmmade of 2nd class teakwood member to be fixed in the table. 54 The rate shall include providing all hardware such as drawer channels, S.S. handles, cable manager, lock of approved make 55 BM Table2100x900x750(H)mm. 56 Officer Tables 1300-1500x750x750 (H)mm. 57 Assistant Tables 900-1250x600x750 (H)mm. 58 Reception counter in semi circular/linear shape with Customer top 300 mm higher than working top as per design & Details to the satisfaction of Banks Engineer. The table size to be 1800x750x1050 59 Providing and fixing in position Side Table/Credenza with the foloowing specifications: 60 The side table top to be fabricated with 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate and8 mm thick clear toughened glass with bevelled edges to be provided on top. 61 The front shutters shall be made from 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate and matching edge binding tape on all sides. 62 The side supports shall be made up from 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate. 63 The back side shall be made from 12 mm thick Moisture Resistant Grade Commercial plywood finsihed with 1 mm thick laminate from outside. 64 The side table shall be provided with two drawers and one below shutter cabinets divided into two parts and one intermediate shelf made from 12 mm thick Moisture Resistant Grade commercial plywood finished with 1 mm laminate on exposed surfaces. The drawer shall be upto 400 mm wide & 450 mm deep. The drawer are to be fixed on telescopic channel channels with 100 mm wide SS handles in matt finish and one multipurpose lock per drawer. The shutters are to fixed with hydraulic autocloser hinges, lock on one of the shutters with 100 mm tower bolt. 65 The item to include 10 mm thick lipping/ teak patti to all edges and all exposed teakwood surfaces / wooden beading are to be finished with melamine polish shade matching with laminate colour 66 The inside surafces are to be finished with 0.8 mm white laminate and edge to be pasted with edge biding tap of matching laminate shade. 67 The rate shall include providing all hardware such as drawer channels, S.S. handles, cable manager, lock of approved make 68 Side Table for Branch Manager 1050x450x750(H)mm. 69 Side Table for Officers 900x450x750(H)mm. 70 Providing and fixing modular type Voucher Tray 900x300x1050 mm deep made out of 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate of approved make, shade and texture with writing top of 12 mm bevelled edge glass and racks for keeping vouchers and cheque drop box with slit for dropping of cheque, glass for viewing and cup board locking arrangement as per Engineer-in-Charge. All exposed edges to be finished with edge binding tape. 71 Providing and fixing in position Looking Mirror of size 600mm x 1500mm in locker room fabricated of 6 mm thick copper back finish looking mirror with bevelled edges fixed on 12 mm thick moisture resistant MDF (interior grade) and 1.0 mm thk. laminate of approved shade on all exposed surfaces. All exposed edges shall be finished with 38mmx19mm teakwood moulding.The looking mirror shall be provided with inbuilt two drawers made from 12 mm thick Moisture Resistant Grade commercial plywood finished with 1 mm laminate on exposed surfaces. The drawer shall be upto 300 mm wide & 225 mm deep. The drawer are to be fixed on telescopic channel channels with 100 mm wide SS handles in matt finish and one multipurpose lock per drawer. 72 SUB TOTAL : IV :COUNTER/TABLES/WORKSTATIONS 73 STORAGE CUPBOARDS 74 Providing & fixing Storage with the following specifications: 75 The top to be fabricated with 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate 76 The front shutters shall be made from 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate and matching edge binding tape on all sides. 77 The side supports shall be made up from 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate. 78 The back side shall be made from 12 mm thick Moisture Resistant Grade Commercial plywood finsihed with 1 mm thick laminate from outside. 79 The storages shall have continuous vertical partitions at every 900 mm with 19 mm thick Moisture Resistant Grade Commercial Block Board finsihed with 1 mm thick laminate and intermediate shelf at every 300 mm made from 12 mm thick Moisture Resistant Grade commercial plywood finished with 1 mm laminate on exposed surfaces. All shutters shall be provided with one lock for two shutters, auto closing hydraulichinges (2 nos. per shutter), brass catchers, 100 mm long S.S. brush finish handles, SS studs for intermediate shelf, 100 mm tower bolt. 80 The item to include 10 mm thick lipping/teak patti to all edges and all exposed teakwood surfaces / wooden beading are to be finished with melamine polish shade matching with laminate colour 81 The inside surafces are to be finished with 0.8 mm white laminate and edge to be pasted with edge biding tap of matching laminate shade. 82 The rate shall include providing all hardware as mentioned above 83 Groovesto be finished with woodtech filler (asian paints/ nerolac paints) of matching shade to laminate 84 Note: Only front elevation shall be considered for area/ quantity calculation and payment. 85 Low Height Storage up to 1200 mm high and 450 mm deep 86 Pantry Storage (Shutters under Platform) 600 mm deep 87 Pantry Storage (Overhead Unit) 400 mm deep 88 SUB TOTAL : V : STORAGE CUPBOARDS 89 MISCELLANEOUS 90 Providing and fixing polyster based DigitalGlass Deco Film (3M) laser cut as per design complete to the satisfaction of Banks Engineer. 91 SUB TOTAL : VI : MISCELLANEOUS 92 TOTAL OF FURNISHING WORK 93 Wiring for light point/ fan point/ wall fan point/ exhaust fan/ light sockets etc. with 1.5 sq.mm. PVC insulated 1100 V Grade copper conductor (FRLS) wires & 1.5 sq.mm. copper earth wire in concealed/ surface using 16 SWG MS conduits, accessories such as bends, tees, saddles, draw boxes, mounting boxes, inner plates, cover plates, ceiling rose etc (whereever required) and chromium plates brass screws/ rowel plug etc. Thecircuit wiring starting from DB to point control box/ switch box using 2 X 2.5 sq.mm PVC insulated 1100 V grade multi- stranded copper conductor wire & 2.5 sq.mm. PVC insulated earth wire (color code to be used). (Flexible conduit/ elbow not allowed). The conduit to be laid in ceiling with proper clamps/ wall/ floor andflling the chase with cement mortar and finishing the same in original form/ wooden partition/ above false ceiling with proper clamps etc. all complete. 94 (Wherever required as per standard specifications). 95 i) Each circuit shall have independent earth wire. 96 ii) Each point shall be earthed. 97 iii) Circuit wiring is to be included in point wiring rates. 98 One light points controlled by one 6 amp. Modular switch 99 Twolight points controlled by one 6 amp. Modular switch 100 Threelight points controlled by one 6 amp. Modular switch 101 Fourlight points controlled by one 6 amp. Modular switch 102 Fivelight points controlled by one 6 amp. Modular switch 103 One call bell point with ceiling rose/ 6amp. 3 pin socket controlled by one 6 amp. Push Modular switch. With call bell 104 One wall fan/ exhaust fan point controlled by one 6 amp. Modular switch. The switch should be at switchboard level 105 One 5 pin socket controlled by one 6 amp. Modular switch complete assembly includes plate box etc. 106 Dependent 107 One ceiling fan point with step type regulator 108 Same as serial no 1 but using 2*2.5 + 1*2.5 Sqmm Copper Conductor FRLS wires from DB to first 6A, 5 Pin modular socket controlled by one 6A switch and looped to the nearest second point with same 2*2.5 + 1*2.5 Sqmm copper conductor wires FRLS insulated 1100V grade. 109 Primary 110 Secondary 111 Same as serial no 1 but using 2*2.5 + 1*2.5 Sqmm Copper Conductor FRLS wires from DB to first 16 Amp MCB two Nos. , for Glow sign Board. 112 Primary Point 113 POWER POINTS 114 Same as serial no.1, but wiring for 16 Amp, 6-pin sockets by using 2*4sq.mm. PVC insulated 1100 V grade copper conductor wire with independent 1* 4.0 sq.mm earth wire from D.B. to first point 1st socket and 1st to 2nd, socket with 2*2.5 sq.mm. and 1*2.5 earth wire including providing and fixing of 16 Amp, 6 –pin socket with 16 Amp. Switch.(Modular type switch/ socket/ plate etc. complete assembly). 115 Primary point 116 Secondary point 117 Same as serial no.1, but wiring for A/C socket by using 2*4 sq.mm. PVC insulated 1100 V grade copper conductor wire and earthing with 1*4.0 sq.mm. PVC insulated 1100 V grade copper conductor wire with modular type AC box(tiny trip type) with socket complete in all respects controlled by 25/32 A SP MCB to be provided near indoor unit. The point starts from DB to stabilizer to the point near the indoor unit including top. 118 Same as serial no.1, but wiring for A/C socket by using 2*6 sq.mm. PVC insulated 1100 V grade copper conductor wire and earthing with 1*6.0 sq.mm. PVC insulated 1100 V grade copper conductor wire of weather proof type 2 way SPN DB complete in all respects controlled by with 32 Amp (10 KA) MCBto be provided near outdoor unit. The point starts from DB to the point near the outdoor unit. Item to also include termination lid between MCB and outdoor unit. 119 Same as serial no.1, but wiring for A/C socket by using 4*6 sq.mm. PVC insulated 1100 V grade copper conductor wire and earthing with 1*6.0 sq.mm. PVC insulated 1100 V grade copper conductor wire and weather proof type 4 way SPN DB complete in all respects controlled by with 40 Amp TPN (10 KA) MCBto be provided near outdoor unit. The point starts from DB to the point near the outdoor unit (includes wires for terminal connection of outdoor unit from TPN) including wiring to the terminals of the outdoor unit from weather proof box. Item to also include termination lid between MCB and outdoor unit. 120 COMPUTER POINTS 121 Wiring with 2x2.5 sq.mm. + 1x2.5 sq.mm. PVC insulated 1100 V grade multi stranded copper conductor wires in 2 mm thick PVC conduit from UPS DB to computer point. Each point to have 3 nos. 6 amps. 5 pin modular type sockets, one 6 amps modular swtich with all accessories, inner/ outer plates, metal box etc. and to be fixed on wooden partitions/ by grouting on wall etc. as per requirement at site. The switch should be fixed above the top of counter with indicator and sockets under the counter. 122 Primary 123 Secondary 124 Wiring with 2x2.5 sq.mm + 1x2.5 sq.mm PVC insulated 1100 V grade multi stranded copper conductor wires in 2 mm thick PVC conduit from UPS DB to computer point. Each point to have 1 nos. 16 amps5 pin modular type sockets, 1 Nos 16 amps modular swtich with all accessories, inner/ outer plates, metal box etc and to be fixed on wooden partitions/ by grouting on wall etc as per requirement at site. The switch should be fixed above the top of counter and sockets under the counter. or as directed by the engineer incharge. 125 Primary 126 Secondary 127 CONDUITINGFOR TELEPHONE, COMPUTER & CONDUITING, WIRING FOR T.V. SYSTEM. 128 TELEPHONE SYSTEM 129 Wiring for VOICE from Jack Panel in data rack to computer workstation with Cat-6 voice cable in PVC conduits of size 20/ 25 mm including providing ferrules at both ends and termination at both ends including providing & fixing frame for telephone socketwith shutter, RJ 47 outlet, faceplate and mounting box complete of modular type. This work includes supply and laying of CAT-6 cable in PVC conduits throughout the lenght, from the I/O hub to the point. 130 Supplying, laying, effecting terminations, testing and commissioning of 0.51 mm dia Cu. Conductor, twisted, colour coded with polythene capor barrier, telephone cables in the existing tray or in conduit including providing &fixing conduit pipe or cable tray as required from building tag block to the floor as required. 131 Supplying & fixing 10 pair krone tag block with enclosure. 132 COMPUTER NETWORKING 133 Wiring for computer networking from Jack Panel in data rack to computer workstation with Cat-6 computer cable in PVC conduits of size 20/ 25 mm including providing ferrules at both ends and termination at both ends including providing & fixing frame for Cat-6 with shutter, RJ 45 outlet, faceplate and mounting box complete of modular type, This work includes supply and laying of CAT-6 cable in PVC conduits throughout the lenght, from the I/O hub to the point. 134 Supplying and fixing 12U (Rack with glass door, opening in the front power panel 1 (horizontal), cable manager 1 lock & key). 135 Supply, Installation, Testing & Commissioning of 24 port Jack Panel. 136 Supplying and fixing Patch Cord-2 Meter- (DBPS Mounting Cord) 137 Supplying and fixing Patch Cord-1 Meter- 138 CABLES, MAINS & SUBMAINS 139 Supplying all materials and laying/ pulling 1100 volts grade PVC insulated copper conductor wires (FRLS) in MS conduit with all fixing accessories after cutting the floor, wall and the like etc. and replastering the floor level to original. Conduit mustbe 30 mm below the floor finish level. 140 2 X 6 sq.mm. + 1 X 6 sq.mm. 141 2 X 4 sq.mm. + 1 X 4 sq.mm. 142 Supplying, laying, testing & commissioning of 4 C X 16 sq.mm. at 1100 volts grade PVC insulated aluminium conductor armoured cable with 10 gauge earth copper wire including cables end termination using appropriate Lugs, Glands, termination acessories, Clamps etc.as required as per specification (, LIGHT PLUG DB, UPS Room & Power DB ). 143 Supplying, laying, testing & commissioning of 4 C X 25 sq.mm. at 1100 volts grade PVC insulated aluminium conductor armoured cable with 10 gauge earth copper wire including cables end termination using appropriate Lugs, Glands, termination acessories, Clamps etc.as required as per specification ( AC DB). 144 Supplying, laying, testing & commissioning of 4 C X 50 sq.mm. at 1100 volts grade PVC insulated aluminum conductor armoured cable including cables end termination using appropriate Lugs, Glands, termination acessories, Clamps etc.as required as per specification (for Main Connection) 145 DISTRIBUTION BOARD 146 Supplying, installing, testing & commissiong of surface/ recessedmountings, Double door 415 volts TPN MCB distributionboard of steel steel, 1.6mm thick dust phosphatized and painted, inclusive of 100 amps, tinned copper busbars, earthbar, common neutral link, din bar for mounting of MCBs detachable gland/ knock out plate & with built in loose wire boxl, and superior make terminalconnectorsforallincomingand outgoing circuits duly prewired with adequate size of PVC insulated copper wiresbetweenthebus barsandthe MCBs as well as the incomer and uptotheterminal connectors/ neutral link and ready for installation of following ways as required. 147 Use B curve MCBs for lighting & small power circuits, C curve for motor duty i.e. for pumps, AC motors,window and split ACs etc. & D curve for UPS DBs i.e. for computers/ PCs circuit. Main incomer & outgoing circuit MCBs shall be selected accordingly i.e. type B,C & D. Contractor to select the MCBs accordingly as per the nature of the circuit/ load. 148 Each DB shall have separate neutral links of rating not less than 100A for each phase. The main incoming neutral link shall be in addition to three outgoing neutral links and shall be of 125 A. 149 UPS DBs shall have a dedicated Earthing link fixed on insulated supports, which will be in addition to body earth link. 150 All internal inter connecting wiring with in theDBs shall be PVC insulated flexible copper conductor wires of adequate capacity as per the current rating. 151 Inside each DB, a DB chart is to be fixed. 152 6-way TPN DB (LIGHTDB & 6 A raw point ) 153 Incomer:- 154 1 No. 40 Amp TPN (10 KA) MCB with 40 A DP RCCB (100 MA) each phase 155 Outgoing:- 156 12 Nos.10/20 Amp (10 KA) SP MCB 157 6-way TPN DB (POWER DB) 158 Incomer:- 159 1 No. 40 Amp TPN (10 KA) MCB with 40 A DP RCCB (100 MA) each phase 160 Outgoing:- 161 12 Nos.10/20 Amp (10 KA) SP MCB 162 8-way SPN DB (UPS INPUT) 163 Incomer:- 164 1 No. 63 Amp TPN 165 Outgoing:- 166 2 Nos.40 Amp DP MCB 167 4-way V-TPN DB (AC) 168 Incomer:- 169 1 No. 63 Amp TPN 4 Pole (16KA) MCCB 170 Outgoing:- 171 3 Nos. 32 Amp (10 KA) TP MCB 172 3 Nos. 32 Amp (10 KA) SP MCB 173 2-way SPN DB with 40 A DP MCB (For UPS Input / output ) 174 12-waySPN DB (For UPS OUTPUT ) 175 Incomer:- 176 1 No. 40 Amp DP (10 KA) MCB with 40 A DP RCCB (100 MA) 177 Outgoing:- 178 8 Nos.6/10/16 Amp (10 KA) SP MCB 179 12-waySPN DB (For ELOBBY UPS OUTPUT ) 180 Incomer:- 181 1 No. 40 Amp DP (10 KA) MCB with 40 A DP RCCB (100 MA) 182 Outgoing:- 183 6 Nos.6/10/16 Amp (10 KA) SP MCB 184 12-waySPN DB (For ELOBBY Light& Powerdb) 185 Incomer:- 186 1 No. 40 Amp DP (10 KA) MCB with 40 A DP RCCB (100 MA) 187 Outgoing:- 188 6 Nos.6/10/16 Amp (10 KA) SP MCB 189 (LIGHT FITTINGS & ACCESSORIES) 190 Supplying, installation with hanging support, testing and commissioning of following light fixtures with electronic Ballasts, Tubes, lamps, all fixing materials including connecting wires etc. all complete as per the directions of Engineer-in-charge (All LED Light Fixures should be covered with minimum 3 Years onsite replacement warranty).TISVA/Polycab/WIPRO 191 FULL GLOW 2 X 2 LED 32 Wslim Smart Panel of make As specified in tender document or approved by SBI/ Architect. 192 Supplying, fixing, testing and commissioning of 15/18 W LED commercial type down lighter of make As specified in tender document or approved by SBI/ Architect. 193 Supplying, fixing, testing and commissioning of 20 W LED T 8 fitting make As specified in tender document or approved by SBI/ Architect. 194 LED Strip for cove lighting 15 W per 5 M with driver and necessary installation supporting fittings of Led strip light (5 mtr.) make as specified in tender document or approved by SBI/ Architect. 195 Wall mounted fans 400/450 mm dia. make As specified in tender document or approved by SBI/ Architect.(METAL BODY) 196 Ceiling fans 1200 mm dia. make As specified in tender document or approved by SBI/ Architect. 197 Supply & fixing of 230 mm exhaust fan withlouvers and plastic body with all accessories etc. complete of make As specified in tender document or approved by SBI/ Architect. 198 Supplying, fixing, testing and commissioning ofcommercial type SUSPENDED LIGHT FIXTUREDecorative Light ,Round 50W(approx) light of make As specified in tender document or approved by SBI/Architect. (Basic price start 10500 rs) 199 EARTHING SYSTEM 200 Supply, Installation, Testing and Commissioning of Maintenace Free Earthing system made up of copper-bonded rod of 10 feet length,23 mm dia. (Minimum copper bonding shall be 0.25mm) along with Rod-to-Conductor connectors, Earth enhancement material, Pit Cover and other accessories as required and as per specification and other applicable codes (include chamber for earthing, Earthing certificate to be submitted along with the bill). 201 Supply, Installation, Testing and Commissioning of Maintenace Free Earthing system made up of copper-bonded rod of 10 feet length, 17.2 mm dia. (Minimum copper bonding shall be 0.25 mm) along with Rod-to-Conductor connectors, Earth enhancement material, Pit Cover and other accessories as required and as per specification and other applicable codes (include chamber for earthing, Earthing certificate to be submitted along with the bill). 202 Providingand fixing of Copper/ GI strips in surface or in recessfor loop earthing etc. as required. 203 Providing andfixing2 X 8 SWG dia. Cu earth wire in PVC conduit on surface or in recess for loop earthing along with the existingsurface/ recess cable as required eith using of copper lug at end termination 204 MAINPANEL AND METER BOARD 205 supply, installation, testing and commissionings of cubicle type floor/wall mounted L.T. Metal D.B ofreputeded make with extendeble rotary handle and extended connecting links 206 1 No. 125 Amps,TPN MCCB (25 KA) with standard enclosure as per manufacturer specification or as approved by the architect/Banks Engineer 207 Designing, fabrication, supply, installation, testing and commissionings of front operated cubicle type compartmentalised, front access, free standing on 75MM [ MS channel, dust and vermin proof (IP 42 degree protection) panel suitable for use at 415V, 3 phase, 4-wire/XLPE Cable 50Hz system suitable for fault level of required value symmetrical at 415V fabricated from 2 mm thick CRCA MS sheets with hinged, gaskettted (Metal based neoprene) locable doors having structural reinforcement including 3 mm thick gland plates on top and bottom, lifting hooks, GI earth strip of required size with 2 nos earth terminals, 1 nos 230V AC operated 250 mm X 250 mm size axial fans for exhaust of heat with On-Off toggle switches including 2 coated primer and 2 power coated paint fnish of approved shade over metal surface cleaned and treated with seven tank process complete with interconnections etc as per specifications as required.main panel board of approved make (Supertech Power Control/Zeniya/Amptech/Neptune) or Equivalent as approved by Architect /Bank. 208 Type of Approval as instructed by the SBI/ Architect). All live accessible parts shall be shrouded and all equipment shall be finger touch proof. The busbars insulation shall be with heat shrinkable sleeves SMC/ DMC shrouds and busbar supports shall be used. Padlocking facility shall be provided on all outgoing feeders doors and switch handles shall be locable in OFF position. 209 Suitable arrangement shall be made for termination of multiple incoming cables. 210 All kA values indicated shall be Ics breaking capacity 211 GA drawings shall be got approved by Architect / SBI 212 Floor panel shall consists of : - 213 INCOMER FROM MAIN LINE 214 1 No. 125 Amps,TPN MCCB (25 KA) with extendeble rotary handle each thermal over current, instantaneous, Short circuit realease,Earth fault. 215 BUSBARS 216 150ampsTPNpolebusbarchamberofsuitable lengthwithcopperbusbars.Allbusbarsand interconnections shallbe of suitable size copper strips. 217 INDICATING PANEL 218 Digitalflushtypeclass-1.0accuracy multifunction meter showing V, A,PF etc. with 3 Nos. current transformers of 125/5A ratio, 10 VA Class-1.0 metering. - 1 sets 219 Red/Blue/Yellowthreephaseindicatinglamps with SP MCB backup protection. 220 OUTGOINGS:- 221 1 Nos 40A TPN MCCB (16 kA)terminals suitable to receivecable on one side and wire connection to Bus bars. For capacitor Bank , 222 1 Nos 63A TPN MCCB (16 kA)terminals suitable to receivecable on one side and wire connection to Bus bars. For AC VTPN, 223 INCOMER FROM MAIN PANEL BUS BAR 224 1no. 100 Amp 4-P On LoadChange over switch with 1 No. 100 Amps, TPN MCCB (25 KA) with extendeble rotary handle. 225 BUSBARS 226 125ampsTPNpolebusbarchamberofsuitable lengthwithcopperbusbars.Allbusbarsand interconnections shallbe of suitable size copper strips. 227 INDICATING PANEL 228 Digitalflushtypeclass-1.0accuracy multifunction meter showing V, A,PF etc. with 3 Nos. current transformers of 100/5A ratio, 10 VA Class-1.0 metering. - 1 sets 229 OUTGOINGS:- 230 2 Nos 63A TPN MCB (10 kA)terminals suitable to receivecable on one side and wire connection to Bus bars. (For PDB & UPS) 231 2 Nos 40A TPN MCB (10 kA)terminals suitable to receivecable on one side and wire connection to Bus bars. (For LDB & Spare) 232 2 Nos 40A TPN MCB (10 kA)terminals suitable to receivecable on one side and wire connection to Bus bars. (For ATM & BRANCH UPS ) 233 3 Nos 40A DP MCB (10 kA)terminals suitable to receivecable on one side and wire connection to Bus bars.(For ATM & SIGNAGE,SPARE) 234 Theelectrical panel as described above and specifications complete. 235 Supply, installation, testing and commissioning of 15 KVAR capacitor as following- 236 Incoming- 40A 4pole MCCB, Outgoing- 6 stage power factor relay with 3 nos. 50/5 current transformer for current sensing capasitor 1 KVR- 1 nos, 2 KVR- 2nos., 5 KVR- 2 nos. Contractors and TP MCB on each complete withphase indication and stage indication. MS cubical having ventilation with wiremesh, copper conductors and aluminium busbars etc complete as per direction of Architect /Bank. (Selec/Neptune/ABB) 237 TOTAL FOR ELECTRICAL WORKS 238 SPLIT/ CASSETTE TYPE AIR CONDITIONERS 239 Supplying, erection, testing and commissioning following wall mounted Split/ Root mounted cassette units of (Toshiba/O-General/ LG/ Carrier) with cordless remote complete with all necessary fittings duly insulated with 9 mm thick nitrile rubber pipe insulation with (All coils – copper only), fan and fan motor, machine control panelimproved Refrigerant Joints, .Air conditioners shall be fitted with hermetically sealed type suction cooled reciprocating or discharge cooled rotary compressor or scroll compressor. Compressor unit operating on R32/ R-410. All complete as per drawing, approval and instructions of the Architect/ Employer. Item to include powder coated outdoor stands as per the manufacturer specifications.(Rates to be inclusive of Copper refrigerant pipe with insulation up to 3 Mtr length only for Each split AC Unit)Note: All Outdoor Should be design at least 45 degree as per ambient temperature. 240 1.0 TR split AC 5 star rating inverter type including all necessary fittings and mountings as specified by the manufacturer 241 1.5/ TR split AC 5 star rating inverter type including all necessary fittings and mountings as specified by the manufacturer 242 2.0/ TR split AC 5 star rating inverter type including all necessary fittings and mountings as specified by the manufacturer 243 EXTRA REFRIGERANT PIPING 244 Supplying and laying of Extra copper refrigerant piping with nitrile rubber pipe insulation, both of size as specified by the manufacturersuitable for 1.0/1.5/ 2.0 TR Split type AC and 2.0 TR/ 3.0 TR/4.0 TR Cassette AC - From Indoor to outdoor Units (make as approved by Architect/ Bank) 245 For 2.0/1.5 TR/ 1.0 TR Split AC as specified by the manufacturer 246 For 3.0 TR/4.0 TRCassette as specified by the manufacturer 247 DRAIN PIPING 248 Providing and fixing drain piping up to drain as directed by the engineer incharge with all accessories e.g. elbows, unions, sockets, reducers, reducing tees, nipples etc. Complete job including cutting chiseling in walls, floor and making good of all chases/ cuts etc. and discharging the drain into a floor trap/ gully as per site conditions with insulation, both as specified by the manufacturer (make as approved by Architect/ Bank). 249 25 mm dia PVC drain pipe for Split AC 250 32 mm dia PVC drain pipe for Cassette AC 251 Providing and fixing of lockable caging for outdoor unit grouted on wall or on roof with open able shutter made of 10 X 10 mm MS square bars placed vertically @ 6” c/c welded with 40 X 3 mm MS flat all- round. Item includes all necessary hardware, priming coat, synthetic enamel paint, hanger, clamps other accessories etc. All complete as per approval and instructions of the Architect/ employer. 252 For 1.0/ 1.5/ 2.0 TR Hi Wall split units 253 For 2.0/ 3.0/4.0 TR TR ceiling mounted cassette unit 254 Supplying and laying of Extra Electrical interconnecting control cable from indoor to outdoor of size as specified by the manufacturersuitable for 1.0/1.5/2.0 TR Split type AC (make as approved by Architect/ Bank). 255 Supplying and laying of Extra Electrical interconnecting control cables from indoor to outdoor of size as specified by the manufacturersuitable for 2.0T/ 3.0T /4.0 TR Cassette type AC (make as approved by Architect/ Bank). 256 Supplying, installation and commissioning of voltage stablizer of range 170-280 V for Acs (V-guard/ Livguard/ Kirnotics make as approved by Architect/ Bank). 257 For 1.0 / 1.5 Tr. Wall mount (4 Kva) 258 Supplying, installation and commissioning of automatic 24 HRS. programmable TIMER of required capacity to run A.C. alternately (MDS/ L&T/ make as approved by Architect/ Bank). 259 Supplying, installation and commissioning of Drain Pump of required capacity to Drain out the water from indoor. 260 TOTAL FOR A.C WORK 261 TOTAL CIVIL WORK 262 TOTAL OF FURNISHING WORK 263 TOTAL FOR ELECTRICAL WORKS 264 TOTAL FOR A.C WORK 265 Pages : 266 Place : 267 Date :

Key Value

Document Fees
Refer document
EMD
INR 85874.0 /-
Tender Value
INR 17.17 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail