| 1 | Cleaning & Desludging by removing semi solid sludge from the sump well / pump wells of any capacity at any depth at sewage pump house installation,mechanically in foul condition including all necessary T&P required for removal of sludge and solid contents to any place out side the defence land without any extra cost etc complete all as specified and directed . |
| 2 | Supply only for stable bleaching powder of 25 Kg bags etc complete all as specified and directed . |
| 3 | Cutting / cleaning away all grass, bushes , under growth tree roots , hedges, vegetation, branches of trees etc around 10 m radius of installation of pump house to the entire satisfaction of Engineer in charge and disposing the same at a distance upto 50 mtr away from the periphery area etc complete all as specified and directed |
| 4 | S&F Mild steel bolts purpose made with hexagonal or square head one end and screwd the other, or screwed both ends, each screwd end to be fitted with washers and one hexagonal or square nut. Exc 5 cm and not exc 20 cm with neck dia from 5 to 15mm complete all as specified |
| 5 | S&F in replacement power contactor 3TF 50 415 V etc including internal wiring in panel complete all as specified and directed . |
| 6 | S&F in replacement power contactor 3TF 49 415 V etc including internal wiring in panel complete all as specified and directed . |
| 7 | S&F in replacement power contactor 3TF 48415 V etc including internal wiring in panel complete all as specified and directed . |
| 8 | S&F in replacement power contactor 3TF 47 415 V etc including internal wiring in panel complete all as specified and directed . |
| 9 | S&F in replacement power contactor 3TF 45415 V etc including internal wiring in panel complete all as specified and directed . |
| 10 | S&F in replacement Bimettalic relay amp range (70-95A) etc including internal wiring in panel complete all as specified and directed . |
| 11 | S&F in replacement Bimettalic relay amp range (32-50A) etc including internal wiring in panel complete all as specified and directed . |
| 12 | S&F in replacement Bimettalic relay amp range (16-25A) etc including internal wiring in panel complete all as specified and directed . |
| 13 | Supply and fixing in replacement Electronic timer switch (03-60 Sec) suitable for star delta starter 230-440V etccomplete all as specified and directed . |
| 14 | S&F in replacement MCCB 3 pole ,415volt ,adjustable type 63 A with breaking capacity 16KAcomplete all as specified and directed . |
| 15 | S&F in replacementMCCB 3 pole ,415volt ,adjustable type 125 A with breaking capacity 16KAcomplete all as specified and directed . |
| 16 | S&F in replacementMCCB 3 pole ,415volt ,adjustable type 200 A with breaking capacity 36KAcomplete all as specified and directed . |
| 17 | S&F in replacementMCCB 4 pole ,415volt ,adjustable type 200 A with breaking capacity 25KAcomplete all as specified and directed . |
| 18 | S&F in replacementMCCB 4 pole ,415volt ,adjustable type 250 A with breaking capacity 36KAcomplete all as specified and directed . |
| 19 | S&F in replacementMCCB 4 pole ,415volt ,adjustable type 400 A with breaking capacity 36KAcomplete all as specified and directed . |
| 20 | S&F in replacement3 phase , class 0.5, digital panel mounted Volt meter in 96 x 96 Sqmm flush mounted case including internal wiring in panel complete all as specified and directed . |
| 21 | S&F in replacement3 phase , class 0.5, digital panel mounted Ammeter in 96 x 96 Sqmm flush mounted case including internal wiring in panel complete all as specified and directed . |
| 22 | S&F in replacementfor ON LOAD change over switch in sheet metal encloser 415 V with side handle operation of rating 400 amp complete all as specified and directed . |
| 23 | S&F in replacement for ON LOAD change over switch in sheet metal encloser 415 V with side handle operation of rating 125 amp complete all as specified and directed . |
| 24 | M & L for two coats of approved synthetic enamel paint over a coat of red oxide zinc chrome primer including preparation / scrapping of old painted surfaces of the LT panel complete and spray painting the same withetc complete all as specified and directed . |
| 25 | Supply and fixing in replacement of cast iron sluice valve double flanged of size 300mm PN 1.6 brass spindle with wheel head, in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed. |
| 26 | Supply and fixing in replacement of cast iron sluice valve double flanged of size 250mm PN 1.6 brass spindle with wheel head, in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed. |
| 27 | Supply and fixing in replacement of cast iron sluice valve double flanged of size 150mm PN 1.6 brass spindle with wheel head, in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed . |
| 28 | Supply and fixing in replacement of cast iron sluice valve double flanged of size 100mm PN 1.6 brass spindle with wheel head, in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed . |
| 29 | Supply and fixing in replacement of cast iron NON Return Valve double flanged of size 300mm in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed . |
| 30 | Supply and fixing in replacement of cast iron NON Return Valve double flanged of size 250mm in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed. |
| 31 | Supply and fixing in replacement of cast iron NON Return sluice Valve double flanged of size 150mm in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed. |
| 32 | Supply and fixing in replacement of cast iron NON Return sluice Valve double flanged of size 100mm in underground pump well 9 meter deep with nuts bolts of suitable size and flanged and testing from smooth functioning etc complete all as specified and directed . |
| 33 | S&F in replacementGun metal, globe or gate valves, with iron wheel head, screwed both ends for 40 mm dia iron pipecomplete all as specified and direceted . |
| 34 | S&F in replacement Gun metal, globe or gate valves, with iron wheel head, screwed both ends for 25 mm dia iron pipecomplete all as specified and direceted . |
| 35 | S&F in replacement40mm bore GI tubing medium grade with all fittings and fixed to walls & ceilings or laid in floors, complete all as specified and directed. |
| 36 | S&F in replacement25mm bore GI tubing medium grade with all fittings and fixed to walls & ceilings or laid in floors, complete all as specified and directed. |
| 37 | Disconnecting of defective burnt elect Motors from pumps after removing all connection like electrical, earthing etc, removing of motors of capacity 05 to 100 HP from 9 meter deep underground pump well foundation, taking to civil workshop for repairing Motors any make and model, in which replacement of defective/unserviceable parts such as bearing,bearing cover, Copper Winding with existing turn, shaft, bush, etc.Reassembling including oiling, greasing, varnishing replacement of worn out nuts, bolts, gasket etc, refixing on its original position(9 meter deep underground pump well foundation ), making all connections, commissioning and testing at full load etc complete all as specified and directed.Note :- (i)Cost of major parts like bearing, shaft, bush, bearing cover shallbe measured and paid separately under respective item of schedue.(ii)Cost of other minor item like thimble, lugs, connection plate, lead, gasket, nuts,bolts,etc essential for functioning of motor &are deemed to be included in quoted rate. (iii)Copper wire for rewinding of motor shall be measured and paid separately. (iv) Transportation, meggering, reconnection & testing, required T&P for work is deemed to be included in quoted rate |
| 38 | Supply super enameled copper wire of existing gauge as original including insulation material with insulation class ‘B’ varnishing, in r/o item No 37 complete all as specified and directed . |
| 39 | Disconnecting of unserviceable pump from motors after removing all electrical/mechnical connections etc of capacity 5 to 100 HP from 9 meter deep underground pump well foundation, taking to civil workshop for repairing of pumping sets any make and model, in which replacement of unserviceable parts such as bearing, bearing cover, shaft, bush, Impeller,Gland Bush, coupling etc. Reassembeling the pump andrefixing on its original position(9 meter deep underground pump well foundation ), making all connections, commissioning and testing at full load complete all as specified and directed.Note : (i) Cost of spare parts (Impeller,Bearing,Gland Plate,Gland Bush ,Shaft, coupling, bearing cover Etc )shall be measured and paid separately under respective item of schedule here after. (ii) Cost of other minor item like gasket, nuts, bolts,etc necessary for efficient functioning of pump is deemed to be included in unit rate of item. (iii) Transportation, reconnection & testing, required T&P for work is deemed to be included in quoted rate |
| 40 | Supply only GlandBush suitable for pump set of capacity 100 HP pump etc in r/o item No 39 complete all as specified and directed . |
| 41 | All as per SI item No40 but of 75 HP capacity . |
| 42 | All as per SI item No40but of 60 HP capacity . |
| 43 | All as per SI item No40 but of 25 /20HP capacity . |
| 44 | All as per SI item No40 but of 5 HP capacity . |
| 45 | Supply only Gland plate suitable for pump set of capacity 100 HP pump etc in r/o item No 39 complete all as specified and directed . |
| 46 | All as per SI item No45 but of 75 HP capacity . |
| 47 | All as per SI item No 45but of 60 HP capacity . |
| 48 | All as per SI item No45 but of 25/20 HP capacity . |
| 49 | All as per SI item No45 but of 5 HP capacity . |
| 50 | Supply only CIImpeller suitable for pump set of capacity 100 HP pump etc in r/o item No 39 complete all as specified and directed . |
| 51 | All as per SI item No50 but of 75 HP capacity . |
| 52 | All as per SI item No 50 but of 60 HP capacity . |
| 53 | All as per SI item No 50 but of 25/20 HP capacity . |
| 54 | All as per SI item No 50but of 5 HP capacity . |
| 55 | S&F in replacement coupling tyre(coupler no. 14,16,18,19,8,8,11) which is suitable for pump set of capacity 100 HP pump etc complete all as specified and directed . |
| 56 | All as per SI item No55but of 75 HP capacity . |
| 57 | All as per SI item No55but of 60 HP capacity . |
| 58 | All as per SI item No55but of 25/20 HP capacity . |
| 59 | All as per SI item No 55but of 5 HP capacity . |
| 60 | Supply only high carbon steel shaft for existing size for 100 HP Pumping set for smooth running in r/o item No 39 complete all as specified and directed . |
| 61 | All as per SI item No60 but of 75 HP capacity . |
| 62 | All as per SI item No60 but of 60 HP capacity . |
| 63 | All as per SI item No 60but of 25/20 HP capacity . |
| 64 | Supply only coupling which is suitable for pump set of capacity upto 100 HP pump etc in r/o item No 39 complete all as specified and directed . |
| 65 | All as per SI item No64 but of 75 HP capacity . |
| 66 | All as per SI item No64 but of 60 HP capacity . |
| 67 | All as per SI item No64 but of 25/20 HP capacity . |
| 68 | All as per SI item No64 but of 5 HP capacity . |
| 69 | Supply only Bearing cover suitable for 100 HP pumping set in r/o item No 39 complete all as specified and directed. |
| 70 | All as per SI item No 69 but of 75 HP capacity . |
| 71 | All as per SI item No 69 but of 60 HP capacity . |
| 72 | All as per SI item No 69 but of 25/20HP capacity . |
| 73 | All as per SI item No 69 but of 5 HP capacity . |
| 74 | Supply only ball bearing cat No 6311 etc in r/o item No 37 & 39 complete all as specified and directed |
| 75 | Supply only ball bearing cat No 6313 etc in r/o item No 37 & 39 complete all as specified and directed . |
| 76 | Supply onlyball bearing cat No 6309 etc in r/o item No 37 & 39 complete all as specified and directed . |
| 77 | S&F in replacement Gland Packing suitable for 100HP pump in r/o item No 39 complete all as specified and directed |
| 78 | S&F in replacement Gland Packing suitable for 75HP pump in r/o item No 39 complete all as specified and directed |
| 79 | S&F in replacement Gland Packing suitable for 60HP pump in r/o item No 39 complete all as specified and directed |
| 80 | S&F in replacement Gland Packing suitable for 20/25HP pump in r/o item No 39 complete all as specified and directed |
| 81 | Material and labour for MS work as in plateform/frames. Clamps / base frame made out of angle , channels ,flat iron ,MS Sheet including cutting, welding cold or hot , rivetting , locking arrangement and applying two coats of synthetic enamel paint over a coat of red oxide primer on exposed surface etc complete all as specified and directed. |
| 82 | M & L for painting of pumpset with motorwith two coat of synthetic enamel paint over a coat of red oxide primer including preliminary preparartion, scrapping old paint with wire brush cleaning of pump set with cotton cloth before painting and writing of SM/MES No all as directedfor the following capacities:- |
| 83 | All as per SI item No 82but of 100 HP capacity . |
| 84 | All as per SI item No 82 but of 75 HP capacity . |
| 85 | All as per SI item No82 but of 60 HP capacity . |
| 86 | All as per SI item No 82 but of 20/25 HP capacity . |
| 87 | All as per SI item No82but of 5 HP capacity . |
| 88 | Preparation / scrapping of old painted surfaces of the DG Set including radiator, fuel tank, alternator assembly etc all parts of DG sets, complete degreasing and spray painting the same with two coats of approved synthetic enamel paint including writing SM/MES nos on DG sets of following capacities etc completeall as specified and directed |
| 89 | All as per SI item No 88 but of D.G Set 250 KVA |
| 90 | All as per SI item No 88 but of D.G Set 160 KVA |
| 91 | All as per SI item No 88 but of D.G Set 62.5/70 KVA |
| 92 | All as per SI item No 88 but ofD.G Set 25/34 KVA |
| 93 | S&Fin replacement Air filter (outer) suitable for 250 KVA capacity DG set. |
| 94 | All as per SI item No 93 but of 160 KVA capacity . |
| 95 | All as per SI item No 93 but of 70 KVA capacity . |
| 96 | All as per SI item No 93 but of 62.5 KVA capacity . |
| 97 | All as per SI item No 93 but of 34/25 KVA capacity . |
| 98 | S&Fin replacementAir filter (inner) suitable for 250 KVA capacity DG set. |
| 99 | All as per SI item No 98 but of 160 KVA capacity . |
| 100 | All as per SI item No 98 but of 70 KVA capacity . |
| 101 | All as per SI item No 98 but of 62.5 KVA capacity . |
| 102 | All as per SI item No 98 but of 34/25 KVA capacity . |
| 103 | S&Fin replacementOil filter suitable for 250 KVA DG set including changing of engine oil complete all as specified. |
| 104 | All as per SI item No 103 but of 160 KVA capacity. |
| 105 | All as per SI item No 103but of 70 KVA capacity . |
| 106 | All as per SI item No 103but of 62.5 KVA capacity . |
| 107 | All as per SI item No 103 but of 34/25 KVA capacity . |
| 108 | S&F in replacement Fuel filter suitable for 250 KVA capacity DGset. |
| 109 | All as per SI item No 108but of 160 KVA capacity. |
| 110 | All as per SI item No 108but of 70 KVA capacity . |
| 111 | All as per SI item No 108 but of 62.5 KVA capacity . |
| 112 | All as per SI item No 108but of 34/25 KVA capacity . |
| 113 | S&F in replacement heavy duty water/coolant rubber hose pipe of any shape as per existing for DG set any capacity all as directed. |
| 114 | S&F in replacement \"V\" belt as per existing size suitable for 250 KVA capacity DGset. |
| 115 | All as per SI item No 114 but of 160 KVA capacity. |
| 116 | All as per SI item No 114 but of 70 KVA capacity . |
| 117 | All as per SI item No 114 but of 62.5 KVA capacity . |
| 118 | All as per SI item No 114 but of 34/25 KVA capacity . |
| 119 | Material and labour for disconnecting / dismentling of self starter from DG set 160 KVA capacity by removing all electrical connections and carring out to work shop for replacing the defecting parts, main shafts, bendex, pinion bearing, DE/CE bush, field coil assembly all including and greasing and refitting and carrying back and connecting, testing complete all as specified and directed . |
| 120 | Ditto all as per SI item No 119 but of 250 KVA capacity. |
| 121 | Ditto all as per SI item No 119but of 70/62.5 KVA capacity. |
| 122 | Ditto all as per SI item No 119 but of 34/25 KVA capacity. |
| 123 | Material and labour for disconnecting / dismentling of dynamo from DG set 25/34 KVA capacity by removing all electrical connections and carring out to work shop for replacing/repair of defective parts like rectifier, carbon brush, replacement of armature winding, repair of commutator all including and refixing the same at site after repair including necessary testing complete all as specified and directed . |
| 124 | All as per SI item No 123but of 62.5/70 KVA capacity. |
| 125 | All as per SI item No 123 but of 160 KVA capacity. |
| 126 | All as per SI item No 123but of 250 KVA capacity. |
| 127 | Supply and Replacement of Engine Oil/Lubricant, 20W40 grade,suitable for Oil change of DG set of any capacity and any make complete all as specified and directed. |
| 128 | Attending complaint of motor/pump/panel /DG set at various locations by replacing spare parts/complaints etc complete all as specified and directed . Note :-(i) The contractor or his representative will attand the office of the Engineer-in-Charge daily (working day) at 0930 hours to collect the complaint slip and will provide atleast two mechanics for repair the moter/pump/panel/DG set of the same is included in the quoted rate.The complaint will be completed/done within 24 hours from the time of issue of complaint slip, failing which a panel recovery of Rs 100/- per complaint per day will be recovered from contractor due\"s and contractor will not have any claim on this account. (ii) Spare parts required against rectification/repair will be measured and paid for saperately) |
| 129 | Strip opening ofportable pump sets for repair of any make and model of capacityupto 5 HP including replacement of defective / unserviceble parts such as bearing shafts, impeller, bush gland plate, remetalling of shaft for fixing of MS bush / bearing, nuts,bolts etc reassembeling the portablepump, making all connections, commissioning and testing at full load complete all as specified and directed . |
| 130 | M&L in replacement for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade C/S area 16 sqmm 4 core complete all as specified and directed |
| 131 | M&L in replacement for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade C/S area 95 sqmm 4 core complete all as specified and directed |
| 132 | M&L in replacement for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade C/S area 120 sqmm 4 core complete all as specified and directed |
| 133 | M&L in replacement for XLPE insulated, armoured, heavy duty electric cable with aluminium conductor, 1100 volt grade C/S area 240 sqmm 4 core complete all as specified and directed |
| 134 | Supply and fixing in replacement of cast iron pipes with flanged ends, centrifugally cast, class \"A\" of size100mm in any length fixing with pump house wall, depth of pump house is 9 meter with all clamps, nuts & bolts and T&P required including joint with jain sheet gasket testing after fixing etc complete all as specified and directed . |
| 135 | Supply and fixing in replacement of cast iron pipes with flanged ends, centrifugally cast, class \"A\" of size150mm in any length fixing with pump house wall, depth of pump house is 9 meter with all clamps, nuts & bolts and T&P required including joint with jain sheet gasket testing after fixing etc complete all as specified and directed . |
| 136 | Supply and fixing in replacement of cast iron pipes with flanged ends, centrifugally cast, class \"A\" of size250mm in any length fixing with pump house wall, depth of pump house is 9 meter with all clamps, nuts & bolts and T&P required including joint with jain sheet gasket testing after fixing etc complete all as specified and directed . |
| 137 | Supply and fixing in replacement of cast iron pipes with flanged ends, centrifugally cast, class \"A\" of size300mm in any length fixing with pump house wall, depth of pump house is 9 meter with all clamps, nuts & bolts and T&P required including joint with jain sheet gasket testing after fixing etc complete all as specified and directed . |
| 138 | Supply,installation,testing and commissioning (in replacement) centrifugal Non ClogPump Set adhering specification not less than :- Suction & Delivery 125X100 MM, Discharge Capacity 65 L.P.S. at 16Mtrs Headcomplete with coupled AC Squirrel cage Induction Motor 3 Phase 415 Volt, 25 H.p ,19 K.W. Capacity & all including base plate, mechanical seals, drain connections and all necessary accessories.and must be compatible with existing piping infrastructure complete all as specified and directed |
| 139 | M & L for earthing with galvanized steel plate electrode 600 x 600 mm x 6 mm size directly burriedin ground vertically to earth pit not less than 2.25 meter deep below normal ground level with top edge of the earth plate not less than 1.5 m below normal ground level surrounded with coal dust and common salt filling in alternative layers of 15 cm thick eachconnected to and including GI earth strip 25x4 mm upto 7.5m by means of nuts, bolts, check nuts & washers etc connecting to earthing test point, main switch board and including 40 mm dia GI pipe light grade for protection of earth lead from earth plate to distribution board/LT Panel and 20 mm dia GI pipe medium grade connected with funnel having wire mess for watering purpose including necessary excavation and earth work, PCC (1:2:4) type B-1 (using stone aggregates)for earthing pit, 10mm thick cast iron cover with angle iron frame all as specified and shown in electrical plate No 3 of SSR Part-I andtesting on completion complete all as specified |