}

Tender For Supply Delivery And Replacement Of Spares For Sub-Station At Mandalkuli Water Supply Scheme , Raipur Block Under Bankura Mechanical Division, Phe Dte., bankura-West Bengal

Public Health Engineering Department has published Tender For Supply Delivery And Replacement Of Spares For Sub-Station At Mandalkuli Water Supply Scheme , Raipur Block Under Bankura Mechanical Division, Phe Dte.. Submission Date for this Tender is 22-07-2025. Substation Tenders in bankura West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

50041733
Tender For Supply Delivery And Replacement Of Spares For Sub-Station At Mandalkuli Water Supply Scheme , Raipur Block Under Bankura Mechanical Division, Phe Dte.
Tender
Indian
West Bengal
Bankura
22-07-2025

Tender Documents

Tender Details

Tender For Supply Delivery And Replacement Of Spares For Sub-Station At Mandalkuli Water Supply Scheme , Raipur Block Under Bankura Mechanical Division, Phe Dte. - 1 supply and delivery of following spares for500 KVA AVR (7/12 KV/11 KV): 2 Control Transformer supply80 VA, 240 V / 110 V 3 Aux Contractor supply (4 NO – 4 NC)Make: Siemens / ABB, Coil Voltage: 110 V AC 4 PCB Relay Card supply for AVR as per existing circuit 5 Voltage Controller Potentiometer (1K) supply 6 1100 VA UPS supply output power wattage 660W or equivalent , Input-50 Hz , wide input voltage range 145-290 V, 2X 7.2 Ah (Or equivalent) battery , provides 30-90 min power back upMake: APC, Input: 230 V AC 7 240 sq. mm. X 3 core, 11 KV grade, Indoor type, Heatshrinkable End Termination Kit supply 8 240 sq. mm., 11 KV grade, indoor type, Heatshrinkable Kit Jointing charges 9 AVR throughout Inspection and Control Operation checking and rectification by opening the cover , checking the throughout circuitswithAux. Contractor replacement charges, PCB Relay Card with voltage controller potentiometer replacement charges, Control Transformer replacement charges, Old UPS Replacement and New UPS Installation Chargesfixing of heat srinkable kit & other as per direction . 10 supply and delivery of following spares forBATTERY CHARGER PANEL: 11 Supply of 65 AH SMF VRLA Battery with 6 nos cell, polyproplene container Make: Exide, consisting of 9 nos. 12 V batteries(Model-EP 65-12 or equivalent) 12 Charges for old defective battery rack by disconnection all the electrical circuitand fitting fixing of thenew battery rack fittings,connection of all batteries checking otesting for a certain period. 13 Supply of 2.5 sq. mm x 4 core cu armored cable forBattery charger panel to 3 panel VCB , as per IS-7098 (Part-I ) 14 Gland supply for 2.5 sq mm x 4 core cu armored cable 15 Laying charges of 2.5 sq. mm x 4 core cu armored cable 16 Charges for Glanding & Socketing for 2.5 Sq mm x 4Core Cable forBATTERY CHARGER PANEL: as per direcrion of EIC 17 Supply and delivery of following spares for 400 KVA, 11 KV/433 V, TRANSFORMER-1 & 2: 18 OTI (4 inch. Dia) supply Make: PTCI 19 WTI (4 inch. Dia) supply Make: PTCI 20 OTI Replacement Charges 21 WTI Replacement Charges 22 Supply of 2.5 sq. mm x 10 core cu armored cable for 3panel VCB to Transformer-1 & 2as per IS-7098 (Part-I ) 23 Gland supply for 2.5 sq mm x 10 core cu armored cable 24 Laying charges of 2.5 sq. mm x 10 core cu armored cable 25 Supply of 2.5 sq mm cu pin Lugs 26 Supply of 2.5 sq mm cu Fork Lugs 27 Charges for Glanding & Socketing for 2.5 Sq mm x 10Core Cable of400 KVA, 11 KV/433 V, TRANSFORMER-1 & 2: as per direction of EIC 28 Supply and delivery of following spares forSINGLE PANEL VCB: 29 240 sq. mm. X 3 core, 11 KV grade, Indoor type, Heat shrinkable End Termination Kit supply 30 240 sq. mm., 11 KV grade, indoor type, Heat shrinkable Kit Jointing charges 31 200-Watt Space Heater supply Make: RECO, 230 V 32 Thermostat supplyMake: ELCON GOLD, Model: MM-106,Range: 30⁰ C - 110⁰ C, 15 Amp., 230 / 250 V AC 33 3 Nos. Space Heater along with 1 No. Thermostatconnection wiring charges as per direction of EIC 34 Supply and delivery of following spares for 3- PANEL VCB: 35 240 sq. mm. X 3 core, 11 KV grade, Indoor type, Heatshrinkable End Termination Kit supply 36 240 sq. mm., 11 KV grade, indoor type, heat shrinkableKit Jointing charges 37 200-Watt Space Heater supply Make: RECO, 230 V 38 Thermostat supplyMake: ELCON GOLD, Model: MM-106,Range: 30⁰ C - 110⁰ C, 15 Amp., 230 / 250 V AC 39 2.5 sq. mm. S/C, 1.1 kV grade Control cable supply for space heater and thermostat wiring 40 2 Nos. Space Heater along with 1 Nos. Thermostatconnection wiring charges for each Panel as per direction of EIC 41 3 Nos. Space Heater along with 1 No. Thermostatconnection wiring charges AS per direction of EIC 42 Attending the fault at Mandalkuli, Bankura District with carrying different Testing, Servicing kit/machine like Insulating Resistance Checking machine (1 KV, 2.5 KV, 5 KV) 3 Phase Variac, Current Injection machine/ kit, Voltage injection machine/kit, Blower, Multimeter, Clamp meter, Different type of tools tackles, Various Testing Wires, MCBS, Wires & Cables, HT insulation Tapes, Gas can with nozzle, CRC, WD-40, Lecta Cleaner, Adhesive non Adhesive PVC Tape and items for complete servicing and testing the Transformers, VCBS, AVR with connecting HT, LT cables 43 Add: 18% GST 44 Add: 1% Cess

Key Value

Document Fees
Refer document
EMD
INR 11000.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail