Health and Family Welfare Government Departments Closing in 0 days TDR #5002922

Temperature Range 2?C To 6?C And Adjustable With Setting Accuracy Of ?0.1?Ccapacity: Should Be Able To Accommodate 300 Standard Blood Bags For Each Of 450 Ml Capacity Or 350-400 Litres Net Volume. Vertical Cabinet (Upright).Polyurethane Insulation Should

Issued by Government Departments · , Maharashtra
Tender Value
Ref. Documents
Estimated cost
Bid Submission
21 Sep 2013
0 days left
EMD
Ref. Documents
Bank guarantee accepted
Document Fee
2000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
→ Maharashtra
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Temperature Range 2?C To 6?C And Adjustable With Setting Accuracy Of ?0.1?Ccapacity: Should Be Able To Accommodate 300 Standard Blood Bags For Each Of 450 Ml Capacity Or 350-400 Litres Net Volume. Vertical Cabinet (Upright).Polyurethane Insulation Should Be Minimum Of 80 Mmthe Door Should Have Minimum 100Mm Polyurethane Insulation With Heated Glass Ware.Microprocessor Based Temperature Controller With Integrated Audio Visual Temperature And Power Alarm Function With Digital Monitoring Display With Decimal. Independent Safety Thermostat To Avoid Negative Temperatures. User Parameter Settings: Set Point, High Alarm Point, Low Alarm Point, Buzzer Off Time, Temperature In Centigrade. Minimum 4 Hours Battery Backup For Temperature / Power Alarm. (Ups)Seven Days Inkless Graphic Temperature Recorder With Range Of -10?C To +20?C, Preferably With Data Logger. Door Opening Audio And Visual Display Alarm.Internal Temperture Hold Over Time In Case Of Power Failure Should Be At Least 90 Minutes. Should Have Provision For Controlled Air Circulation For Constant Temperature Distribution. 2 Temperature Sensors: 1 Ntc (Negative Temperature Control) Sensor For Temperature Monitoring Shown On Front Display, 1 Ntc (Negative Temperature Control)Sensor For Managing Use Of Compressor. Stainless Steel Material For Interior Walls And Shelves, Perforated On The Bottom For Perfect And Homogeneous Distribution Of Cold Air With Bacteria Resistant Coating. Should Have A Transparent Outer Door For Clear Visibility. Automatic Front Door Closing Below A Door Opening Angle Of 90?Refrigerant Should Be Cfc Free. Controlled Fan Cooling System For Constant Internal Uniform Temperature Distribution At Ambient Temperature Up To 43?Cair Cooled Compressor Ideal Compressors Running Time Of 27% At 25?C Ambient Temperature. Door Locks Should Be Providedshould Have Lockable Castors For Free And Easy Mobilityaudio And Visual Alarm For Variation In Temperature. External Ambient Temperature +10?C To +43?Cauto Defrosting Should Be Provided Cooling Time: 10 To 15 Hours For All The Packs To Reach Below +6?Cinterior Lighting Should Be Providedweight: To Be Indicated By The Bidderit Should Be Operational On 220 To 240 Volts At 50 Hz, Single Phase Aca Line Voltage Corrector Of Appropriate Rating Should Form Part Of Standard Configuration. Should Ce & Usfda Approved. Standard Accessories: Provision Of Dividers In Racks And Essential Accessories To Be Part Of The Equipment. Thermal Chart Papers Should Be Supplied For The Warranty Period. Technical Manual In English With Operational Details Should Be Provided With Each Unit. Warranty Period 2 Years And Annual Maintenance Contract 3 Years Uptime Of Equipment Should Be 98% And Down Time Is Less Than 2%Service Time For Mumbai In 4 Hours And Out Of Mumbai 24 Hours.

AI Tender Summary

OUR REF NO 5002922
AUTHORITY Government Departments
TENDER VALUE Ref. Documents
LAST DATE 21-09-2013
Authority
Authority Name Public Health Department.
Work Description Temperature Range 2?C To 6?C And Adjustable With Setting Accuracy Of ?0.1?Ccapacity: Should Be Able To Accommodate 300 Standard Blood Bags For Each Of 450 Ml Capacity Or 350-400 Litres Net Volume. Vertical Cabinet (Upright).Polyurethane Insulation Should Be Minimum Of 80 Mmthe Door Should Have Minimum 100Mm Polyurethane Insulation With Heated Glass Ware.Microprocessor Based Temperature Controller With Integrated Audio Visual Temperature And Power Alarm Function With Digital Monitoring Display With Decimal. Independent Safety Thermostat To Avoid Negative Temperatures. User Parameter Settings: Set Point, High Alarm Point, Low Alarm Point, Buzzer Off Time, Temperature In Centigrade. Minimum 4 Hours Battery Backup For Temperature / Power Alarm. (Ups)Seven Days Inkless Graphic Temperature Recorder With Range Of -10?C To +20?C, Preferably With Data Logger. Door Opening Audio And Visual Display Alarm.Internal Temperture Hold Over Time In Case Of Power Failure Should Be At Least 90 Minutes. Should Have Provision For Controlled Air Circulation For Constant Temperature Distribution. 2 Temperature Sensors: 1 Ntc (Negative Temperature Control) Sensor For Temperature Monitoring Shown On Front Display, 1 Ntc (Negative Temperature Control)Sensor For Managing Use Of Compressor. Stainless Steel Material For Interior Walls And Shelves, Perforated On The Bottom For Perfect And Homogeneous Distribution Of Cold Air With Bacteria Resistant Coating. Should Have A Transparent Outer Door For Clear Visibility. Automatic Front Door Closing Below A Door Opening Angle Of 90?Refrigerant Should Be Cfc Free. Controlled Fan Cooling System For Constant Internal Uniform Temperature Distribution At Ambient Temperature Up To 43?Cair Cooled Compressor Ideal Compressors Running Time Of 27% At 25?C Ambient Temperature. Door Locks Should Be Providedshould Have Lockable Castors For Free And Easy Mobilityaudio And Visual Alarm For Variation In Temperature. External Ambient Temperature +10?C To +43?Cauto Defrosting Should Be Provided Cooling Time: 10 To 15 Hours For All The Packs To Reach Below +6?Cinterior Lighting Should Be Providedweight: To Be Indicated By The Bidderit Should Be Operational On 220 To 240 Volts At 50 Hz, Single Phase Aca Line Voltage Corrector Of Appropriate Rating Should Form Part Of Standard Configuration. Should Ce & Usfda Approved. Standard Accessories: Provision Of Dividers In Racks And Essential Accessories To Be Part Of The Equipment. Thermal Chart Papers Should Be Supplied For The Warranty Period. Technical Manual In English With Operational Details Should Be Provided With Each Unit. Warranty Period 2 Years And Annual Maintenance Contract 3 Years Uptime Of Equipment Should Be 98% And Down Time Is Less Than 2%Service Time For Mumbai In 4 Hours And Out Of Mumbai 24 Hours.
Basic Detail
Tender No E-189/DHS/Instruments&Equipments/PC/2013-14
Bidding Type Tender
Location
City
State Maharashtra
Key Dates
Publish Date 10 Sep 2013
Submission Date 21 Sep 2013
Open Date 25 Sep 2013
Finance
Tender Value Ref. Documents
Tender Fee 2000
EMD Ref. Documents
Exemption Not Available

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Sep 10, 2013
11:30 IST

Tender Published

Tender notice published.

Completed
Sep 21, 2013
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Sep 25, 2013

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders