Drinking Water Supply and Sanitation Boards / Undertakings / PSU Closing in 0 days TDR #50021533

Supply Installation Testing And Commissioning Of Lt Panels And Starters And Other Electrical Equipment At Bb Block Bps In Hari Nagar In Ac-28.

Issued by Boards / Undertakings / PSU · janakpuri, Delhi
Tender Value
Ref. Documents
Estimated cost
Bid Submission
11 Jul 2025
0 days left
EMD
11300
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
janakpuri → Delhi
EMD Exemption
Available
Quantity
Not Available

Project Description

supply installation testing and commissioning Of Lt Panels And Starters And Other Electrical Equipment At Bb Block Bps In Hari Nagar In Ac-28.- 1 LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection. Each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1400MM x1200x375mm. Having following components of approved make. 2 MCCB 415V, Four Pole High breaking capacity 50KA 50Hz,320Amp with spreader- Make L&T/Siemens 3 MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,100Amp with spreader - Make L&T/Siemens 4 MCB Single pole 6Amp. Make L&T/Siemens 5 MCB Triple pole 63Amp. Make L&T/Siemens 6 MCB Triple pole 32Amp. Make L&T/Siemens 7 Over load relay 36-60 amp Make: L&T/Siemens 8 Over load relay 4.5 -7.5 amp Make: L&T/Siemens 9 Digital Amp. Meter Make AE/L&T 10 Digital Volt Meter-Make AE/L&T 11 Motor protection RelayM-10 type Make: L&T/Siemens/Protech 12 Power contactor 220V 3phase 40Amp. Make L&T/Siemens 13 Power contactor 220V 3phase 70Amp. Make L&T/Siemens 14 Power contactor 220V 3phase18Amp. Make L&T/Siemens 15 Star delta timer on delay make: L&T/Siemens 16 Indicating lights LED type RYB & On/OFFMake: L&T /Siemens 17 Current Transformer300/5& 100/5Make AE /Advance/Saviour 18 On load change over switch 200Amp. Open execution type Make:L&T/HPL 19 Supply of25 sq mm Single core Copper Cable. Make: Havells/polycab /Grandlay/Finolex/ any other make approved by DJB 20 Loading, unloading by crane or heavy labor and cartage up to site cleaning & dressing the surface for 21 Installation of the panel at site on base frame, laying of cable, termination of cable both incoming &out going side 22 Testing & commissioning of panel, as per required parameters with relevant IS. testing of the panel prior to switching on as follow:-i) Continuity and earth testingii) Meagering of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. iii) checking for all tightness of nut and boltsiv) Alignments of doors etc. Interlocking tests. All function tests

BOQ

Name of Work: SITC of LT Panels & Starters and other electrical equipmet at BB BlockBPS inHari Nagar in AC-28.
Sl. No. Item Description
1LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection. Each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1400MM x1200x375mm. Having following components of approved make.
2MCCB 415V, Four Pole High breaking capacity 50KA 50Hz,320Amp with spreader- Make L&T/Siemens
3MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,100Amp with spreader - Make L&T/Siemens
4MCB Single pole 6Amp. Make L&T/Siemens
5MCB Triple pole 63Amp. Make L&T/Siemens
6MCB Triple pole 32Amp. Make L&T/Siemens
7Over load relay 36-60 amp Make: L&T/Siemens
8Over load relay 4.5 -7.5 amp Make: L&T/Siemens
9Digital Amp. Meter Make AE/L&T
10Digital Volt Meter-Make AE/L&T
11Motor protection RelayM-10 type Make: L&T/Siemens/Protech
12Power contactor 220V 3phase 40Amp. Make L&T/Siemens
13Power contactor 220V 3phase 70Amp. Make L&T/Siemens
14Power contactor 220V 3phase18Amp. Make L&T/Siemens
15Star delta timer on delay make: L&T/Siemens
16Indicating lights LED type RYB & On/OFFMake: L&T /Siemens
17Current Transformer300/5& 100/5Make AE /Advance/Saviour
18On load change over switch 200Amp. Open execution type Make:L&T/HPL
19Supply of25 sq mm Single core Copper Cable. Make: Havells/polycab /Grandlay/Finolex/ any other make approved by DJB
20Loading, unloading by crane or heavy labor and cartage up to site cleaning & dressing the surface for
21Installation of the panel at site on base frame, laying of cable, termination of cable both incoming &out going side
22Testing & commissioning of panel, as per required parameters with relevant IS. testing of the panel prior to switching on as follow:-i) Continuity and earth testingii) Meagering of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. iii) checking for all tightness of nut and boltsiv) Alignments of doors etc. Interlocking tests. All function tests

AI Tender Summary

OUR REF NO 50021533
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 11-07-2025
Authority
Authority Name Delhi Jal Board
Work Description supply installation testing and commissioning Of Lt Panels And Starters And Other Electrical Equipment At Bb Block Bps In Hari Nagar In Ac-28.- 1 LT Distribution panel sheet steel enclosure made out of 2mm CRCA sheet totally enclosed, powder coated free standing, floor mounted type, dust& vermin proof, outward opening, lockable doors having hidden hinges and a bolted back cover both using non-deteriorating neoprene rubber gaskets to provide IP-54 protection. Each part of the fabricated panel will be strictly subjected to seven tank treatment. The various components, assemblies and sub equipment’s of the panel will be as per standard given in relevant IS. The bus bar of the panel will be shaped out of high conductivity, electrolytic conductor and shall be liberal sized in aluminum. The control wiring of the panel will be done with PVC flexible copper wires of 1.5mm cross section. Each wire will be terminating with a ferule crimped to the wire, size 1400MM x1200x375mm. Having following components of approved make. 2 MCCB 415V, Four Pole High breaking capacity 50KA 50Hz,320Amp with spreader- Make L&T/Siemens 3 MCCB 415V, TP 3phase High breaking capacity 50KA 50Hz,100Amp with spreader - Make L&T/Siemens 4 MCB Single pole 6Amp. Make L&T/Siemens 5 MCB Triple pole 63Amp. Make L&T/Siemens 6 MCB Triple pole 32Amp. Make L&T/Siemens 7 Over load relay 36-60 amp Make: L&T/Siemens 8 Over load relay 4.5 -7.5 amp Make: L&T/Siemens 9 Digital Amp. Meter Make AE/L&T 10 Digital Volt Meter-Make AE/L&T 11 Motor protection RelayM-10 type Make: L&T/Siemens/Protech 12 Power contactor 220V 3phase 40Amp. Make L&T/Siemens 13 Power contactor 220V 3phase 70Amp. Make L&T/Siemens 14 Power contactor 220V 3phase18Amp. Make L&T/Siemens 15 Star delta timer on delay make: L&T/Siemens 16 Indicating lights LED type RYB & On/OFFMake: L&T /Siemens 17 Current Transformer300/5& 100/5Make AE /Advance/Saviour 18 On load change over switch 200Amp. Open execution type Make:L&T/HPL 19 Supply of25 sq mm Single core Copper Cable. Make: Havells/polycab /Grandlay/Finolex/ any other make approved by DJB 20 Loading, unloading by crane or heavy labor and cartage up to site cleaning & dressing the surface for 21 Installation of the panel at site on base frame, laying of cable, termination of cable both incoming &out going side 22 Testing & commissioning of panel, as per required parameters with relevant IS. testing of the panel prior to switching on as follow:-i) Continuity and earth testingii) Meagering of all equipment’s for phase to phase, neutral to body, neutral to earth and phase to earth. iii) checking for all tightness of nut and boltsiv) Alignments of doors etc. Interlocking tests. All function tests
Basic Detail
Tender No e-NIT No.06 / (EnM)M-VIII/ 2025-26
Bidding Type Tender
Location
City janakpuri
State Delhi
Key Dates
Publish Date 05 Jul 2025
Submission Date 11 Jul 2025
Open Date 11 Jul 2025
Finance
Tender Value Ref. Documents
Tender Fee 500
EMD 11300
Exemption Available
Document List
348ebac5-69b4-42fd-854f-e2a83aa439e6.html
BOQ_362148.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 05, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 11, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 11, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

348ebac5-69b4-42fd-854f-e2a83aa439e6.html

xls

BOQ_362148.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders