Public Administrative Department Local Bodies Closing in 0 days TDR #50020558

Tender For Provision Of Lighting Arrangement At Kalka Das Marg Mehrauli, Jahaj Mahal Park And Various Places In Ward No. 155 Mehrauli Under South Zone.

Issued by Local Bodies · mehrauli, Delhi
Tender Value
89.11 Lakhs
Estimated cost
Bid Submission
14 Jul 2025
0 days left
EMD
1.87 Lakhs
Bank guarantee accepted
Document Fee
1180
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
mehrauli → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Provision Of Lighting Arrangement At Kalka Das Marg Mehrauli, Jahaj Mahal Park And Various Places In Ward No. 155 Mehrauli Under South Zone.

BOQ

Work Name: Provision of lighting arrangement at Kalka das marg Mehrauli, Jahaj Mahal Park and various places in ward no. 155 Mehrauli under South Zone.
Sl. No. Item Description
1Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Upto 35 sq. mm
2Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Upto 35 sq. mm
3Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
4Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 meter long etc. with charcoal/ coke and salt as required
5Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
6Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
7Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm
8Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm(L) x 450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia -960 mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1400 mm (approx.) - 6 nos. (with 150 mm spacing) as required with supplying andpositioning of 4 nosfoundation bolts of size 16mm dia and 600 mm long j type i/c 2 nos. template anchor plates of size 225x225x3 mm and providingDWC HDPE for cable entry & exit as required for3 m and 5 mtr pole.
9Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate,window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd,terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable. logo/Name of manufacture shall be embossed on the pole.Galvanization as per relevant IS. (a) 5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick.
10Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm(L) x 600 mm wide and 1200 mm deep i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -1160 mm long (approx.) - 8 nos.and reinforcement of cold twisted bar of 8 mm dia - 1600 mm (approx.) - 8 nos. (with 150 mm spacing) as required with supplying andpositioning of 4 nosfoundation bolts of size 20mm dia and 750 mm long j type i/c 2 nos. template anchor plates of size 225x225x3 mm and providingDWC HDPE for cable entry & exit as required for 7 mtr and 8 mtr pole.
11Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate,window with flash cover with full verticle window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd,terminal block suitable for 25 sq mm conductor – 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB ‘C’ characteristics, earth stud, cable support clamp suitable for 4x25 sqmm cable. logo/Name of manufacture shall be embossed on the pole.Galvanization as per relevant IS. (b) 7.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick.
12Fabrication supplyiing and fixing B-class Galvanised single overhang arm bracket made out of 250 mm long galvanized top tube with cap 1000mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd.
13Fabrication supplyiing and fixing B-class Galvanised doubleoverhang arm bracket made out of 250 mm long galvanized top tube with cap 1000mm long 32 mm dia galvanized pipe with tightening bolts complete as reqd.
14Fabrication,Supplying,Installation,testing,Commissioning of 12 mts.high mast System with its accessories ,Mast shaft shall be in one section , hot dip galvanized 4mm thick (Single dip ) inside and out sides and suitable for wind velocity as per IS 875 part3 .There shall be in longitudinal seam weld per section and No circufrential weld. It should also included accessories for High Mast head frame ,2 point suspension system with steel wire rope 5mm dia. (7/19construction) single drum winch ,galvanized lantern carriage arrangement suitable for 4/6 Nos. flood light luminaries luminaries symmitrically and its control gears boxes and lighting finial ,the mast shall have integral type manual tool mounted at the base compartment of its raising and lowering operation with foundation bolts and Anchor plate and control panel housing suitable RCC (1:2:4) shallow foundation of size 1m(L)X1m (W)X2m deep i/c excavation of earth i/c excavation of earth, providing cutting, bending and placing in position, rewinforcement of cold twisted bars of 12 mm dia -2100 mm long (approx.) - 16 nos.and reinforcement of cold twisted bar of 8 mm dia - 3700 mm (approx.) - 13 nos. (with 150 mm spacing) as required withpositioning of 4 nosfoundation bolts and providing DWC HDPE pipe for cable entry & exit as required forhigh mast considering The safe soil bearing capacity at site as 10T/sqm at 2mts. Depth with all material i/c,4Nos S.PMCB,63Amp.DPIsolator etc as reqd. Logo/Name of manufacturer shall be embossed on the pole. galvanized as per relevant IS.
15Supply and fabrication of pole protection system made up 8 SWG steel wire mesh of size 25 mm x 75 mm rectanglar with 50 mm X50 mmX6mm MS angle iron for supporting the mesh i/c MV Danger Plate and grounding the protection system in suitable quality of CC etc.
16Supply of XLPE insulated,PVC sheathed Al.conductor Armoured cable1.1KV grade Conforming to IS 7098/1988 of following Sizes (a) 2 X6 SQmm
17Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc..direct in ground (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc., complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
18Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. 63 mm dia (OD-63 mm & ID-51 mm nominal)
19Drilling and laying i/c HDPE pipe of 40 mm outer dia with PN 4rating by hand moling/ Mannual method conforming to IS 4984.
20Excavation of the cable trenches in hard rock not exceeding 1.5 metres in width, and lift upto 1.5 metres, including getting outthe excavated soil and disposal of excavated soil as directed within a lead of 50 metres
21Providing and laying in position cement concrete of specific grade excluding the cost of centering and shuttering-all work up to plinth level:1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources.
22Providing and fixing of Stainless steel name plate of size 6X8 sq inch made of 20 gauge sheet including engraved name of area representative duly painted along with SS clamp nut bolt etc as required.
23Supplying and fixing of light class G.I. pipe of 50 mm dia. (nominal)3 metres length along the pole for protection of under ground cable as required.
24Providing and fiving name board made of MS Sheet 90x60cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6mm, total height of the board above ground level 2.40m, length of legs below ground 0.30m embedded in CC block 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size) 30x30x45cm including excavation and removal of surplus earth with in 50m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour (one side) as per drawing/direction of Engineer-in-Charge
25Supply of 45 watt LED Street Light Luminaire fitted with lens made of pressure die cast aluminum housing and toughened glass cover complete with the following specifications as per relevant IS (a) Total System Wattage: 45 Watt+/- 5% (b) Luminaire Efficacy- 120 Lumens/watt (minimum) (c) Power factor > 0.95 (d) Protection Class IP66 (e) LED Package shall be Ceramic Base. (f) Multi Chip. Array, Multi Die, Mid Power, Integrated Arrays and COB type Chip are not permitted. (g) Operating current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED Package : One watt to Five watt maximum (i) CRI > 70 (j) THD < 10% for complete fixture (k) Operating Voltage- 110-320V, 50 Hz +/- 3% (l) The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver (m) Life of Street Light: Minimum 50,000 hrs
26Supply of 70 watt LED Street Light Luminaire fitted with lens made of pressure die cast aluminum housing and toughened glass cover complete with the following specifications as per relevant IS (a) Total System Wattage: 70 Watt+/- 5% (b) Luminaire Efficacy- 130 Lumens/watt (minimum) (c) Power factor > 0.95 (d) Protection Class IP66 (e) LED Package shall be Ceramic Base. (f) Multi Chip. Array, Multi Die, Mid Power, Integrated Arrays and COB type Chip are not permitted. (g) Operating current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED Package : One watt to Five watt maximum (i) CRI > 70 (j) THD < 10% for complete fixture (k) Operating Voltage- 110-320V, 50 Hz +/- 3% (l) The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver (m) Life of Street Light: Minimum 50,000 hrs
27Supply of 140 watt LED Street Light/Floof light Luminaire fitted with lens made of pressure die cast aluminum housing and toughened glass cover complete with the following specifications as per relevant IS (a) Total System Wattage: 140 Watt+/- 5% (b) Luminaire Efficacy- 130 Lumens/watt (minimum) (c) Power factor > 0.95 (d) Protection Class IP66 (e) LED Package shall be Ceramic Base. (f) Multi Chip. Array, Multi Die, Mid Power, Integrated Arrays and COB type Chip are not permitted. (g) Operating current of LED < 70% of rated maximum forward current, limited to a minimum of 350 mA and maximum of 1000 mA. (h) Wattage of LED Package : One watt to Five watt maximum (i) CRI > 70 (j) THD < 10% for complete fixture (k) Operating Voltage- 110-320V, 50 Hz +/- 3% (l) The driver must have thermal Protection against 75 deg C ambient temperature with internal SPD of minimum 6 KV. Separate Compartment for Driver (m) Life of Street Light: Minimum 50,000 hrs
28Installation and commissioning of Street Light/Flood Light etc. as required.

AI Tender Summary

OUR REF NO 50020558
AUTHORITY Local Bodies
TENDER VALUE 89.11 Lakhs
LAST DATE 14-07-2025
Authority
Authority Name Municipal Corporation Of Delhi
Work Description Tender For Provision Of Lighting Arrangement At Kalka Das Marg Mehrauli, Jahaj Mahal Park And Various Places In Ward No. 155 Mehrauli Under South Zone.
Basic Detail
Tender No EEE/SZ/2025-26/NIT/16
Bidding Type Tender
Location
City mehrauli
State Delhi
Key Dates
Publish Date 05 Jul 2025
Submission Date 14 Jul 2025
Open Date 14 Jul 2025
Finance
Tender Value 89.11 Lakhs
Tender Fee 1180
EMD 1.87 Lakhs
Exemption Not Available
Document List
Tendernotice_2.pdf
f57fc100-5f47-4a01-afd2-ba2ca52a5490.html
Tendernotice_1.pdf
condition.pdf
BOQ_273600.xls

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Jul 05, 2025
11:30 IST

Tender Published

Tender notice published.

Completed
Jul 14, 2025
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Jul 14, 2025

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

Tendernotice_2.pdf

html

f57fc100-5f47-4a01-afd2-ba2ca52a5490.html

pdf

Tendernotice_1.pdf

pdf

condition.pdf

xls

BOQ_273600.xls

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders