Tender For Budgetary Offer For Supply Of Transformers, Raigad-Maharashtra

Jawaharlal Nehru Port Trust has published Tender For Budgetary Offer For Supply Of Transformers. Submission Date for this Tender is 10-07-2025. Power Transformer Tenders in Raigad Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

50008107
Tender For Budgetary Offer For Supply Of Transformers
Tender
Indian
Maharashtra
Raigad
10-07-2025

Tender Documents

Tender Details

Tender For Budgetary Offer For Supply Of Transformers; 1. 7MVA Step down Transformer: 3 No’s Parameter Details Type Dry Type, Cast Resin Power Transformer Rated Capacity 7 MVA Cooling Type AN (Air Natural) Primary Voltage 33 kV (or as per project requirement) Secondary Voltage 6.6 kV (or as required) Frequency 50 Hz Phase 3 Phase Vector Group Dyn11 Winding Material Copper (Electrolytic Grade) Insulation Class Class F Tapping Range Off-Circuit Tap Changer: -5% to +5% Temperature Rise Max 100°C, 50°C ambient (as per site conditions) Impedance 6.25% Enclosure IP Rating IP42 Outdoor (in container) Standard IEC 60076-11, IS 11171, IEC 60076-1 Page 2 of 4 2. 4 MVA Step down Transformer – 3 No’s Parameter Details Transformer Type Cast Resin Dry Type Transformer Cooling Type AN (Air Natural) Rated Capacity 4 MVA Frequency 50 Hz Number of Phases 3 Phase Primary Voltage (HV) 6.6 kV Secondary Voltage (LV) 690 V Tapping Range Off-Circuit Tap Link: ±5% in steps of 2.5% Vector Group Dyn11 Winding Material Copper (Class F) Installation Type (Outdoor with enclosure) Ambient Temperature 50°C Enclosure Protection (Optional) IP42 Outdoor (in container) Standard Applicable IS 11171 / IEC 60076-11 Impedance 8% 3. 4 MVA Converter duty transformer – 3 No’s Parameter Details Transformer Type Dry Type, Cast Resin, Converter Duty Power Rating 4 MVA Cooling Type AN (Air Natural) Primary Voltage (LV) 0.69 kV Secondary Voltage (HV) 6.6 kV Frequency 50/60 Hz Vector Group Dyn11 Impedance 8% No. of Phases 3 Phase Tapping Range Off-Circuit Tap Link: ±5% in steps of 2.5% Duty Type Converter Duty (suitable for feeding variable frequency drives or rectifiers) Winding Material Electrolytic Grade Copper Insulation Class Class F (winding), Class H (resin), max temp rise: 100°C Installation IP 42 Ambient Temp. 50°C Applicable Standards IS 11171 / IEC 60076-11, IEEE C57.12.01, IEC 61378-1 (for converter duty) Page 3 of 4 4. 250 KVA Aux. Transformer – 1 No. Parameter Details Transformer Type Dry Type, Cast Resin Encapsulated Rated Capacity 250 kVA Primary Voltage (HV) 6.6 kV Secondary Voltage (LV) 433 V Frequency 50 Hz Phase 3 Phase Cooling Type AN (Air Natural) Vector Group Dyn11 Tapping Range Off-Circuit Tap Link: ±5% in steps of 2.5% Winding Material Copper (Electrolytic Grade) Insulation Class Class F (winding), Class H (resin), Temp rise ≤ 100°C over ambient Mounting Indoor (or outdoor with enclosure) Enclosure Protection (optional) IP23 standard (upgradable to IP44/IP55) Applicable Standards IS 11171 / IEC 60076-11

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail