Tender For Addn/Altn To Certain Omqs, Smqs And Allied Works At Afs Kumbhirgram; 1 Taking down existing tarfelt including tiles, lime concrete & screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 50m and n. exc.100m incl roughening ofold concrete surface of roofby wire brushing and cleaning the surface to remove all loose dust etc complete all as specified and as directed. 2 M&L for 15mm thick screed bed or bedding layers in cement mortar (1:4) in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane, and water proofing compound @ 3% finished even and smooth without using extra cement complete all as specified and as directed. (NOTE : Polymeric membrane shall be measured and paid separately under relevant item of this Schedule A). complete all as specified and as directed. 3 M&L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyster non wove febric (wt. not less than 150 gms/sqm) land on primed surface by forced application complete all as specified and as directed. 4 Cutting through brick wall for holes and making good disturb portion in CM (1:3).Exc half brick thick wall but not exc one brick thick wall. 5 M&L for PVC floor trap plain with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).75mm dia 6 M&L for PVC Nahani trap plain with grating including jointing to waste pipe fixed in cement concrete type B1(1:2:4).75mm dia 7 S&F in repair 10 ltr capacity PVC flushing cistern low level white colour incl PVC connection PVC flush pipe of reqd length CI brackets nin lieu of old unservisable push button flushing system and including L-Bend complete all as specified and as directed. 8 S&F vitreous chinasquatting panOrissa pattern size 580x440mm white with intgeral foot rests(excluding flushing cistern and flush pipe) with P or S trap fron or back inlet etc including connection to trap tand flushing pipe and provision of lime concrete bedding complete all as specified and as directed in repairs including demolition of existing one 9 Supply and fixing Vitreous China, wash down water closet pedestal pattern white (excluding fixing bolts, flushing cistern and flush pipe complete all as specified and as directed. 10 S&F in repairs 15 mm bore stop cock,(angle valve) cast copper alloy, fancy type, chromium plated, screwed down, high pre-ssure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed complete all as specified and directed. 11 S&F in repair PVC connection 15 mm size with PTMT nuts of length 600 mm complete all as specified & directed 12 Taking down CI/PVC/AC soil pipe including fittings. 13 S&F 110mm dia PVC SWR pipes single socketed in any length with rubber ring joints, fixed to wall. 14 S&F 110mm dia PVC SWR bends of any radius with access door complete all as specified and as directed 15 S&F 110mm dia PVC (SWR) junction single T equal or unequal with access door Complete all as specified and as directed. 16 Dismantling, floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed. 17 Materials and labour for Virified Ceramic tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match all specified and as directed. 18 Ditto as per ser item No 2 but as skirting /dado all as specified and directed. 19 Material and Labour for Non skid colour ceramic tiles as in floor 300x 300x 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match, including screed bed or bedding layer of mortar 10mm thick for laying floor finishes in cement mortar 1:6, complete all as specified and as directed.Make: Somany/ Orient/ Johnson 20 Material and Labour for Glazed colour ceramic tiles in vertical surface 300X 200X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match including rendering cementmortar 10mm thick for fixing tile in dado/skirtingin CM 1:3, complete all as specified and as directed.Make: Somany/ Orient/ Johnson 21 S&F 110mm dia PVC (SWR) branch piece, single ‘Y‘ equal or unequal with access doorComplete all as specified and as directed. 22 Demolition of concrete (Un-reinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed. 23 M & L PCC (1:2:4) type B1 (20mm graded aggregate)as in roof kerbs, slightly rounded or chamfered on edges, mixed with water proofing compound in top layer @ 3% by weight of cement or as per manufacturer instructions finished even and smooth on exposed concrete surface without using extra cement all complete as specified and as directed.(Note: Water proofing compound shall be measured and paid perarately under relevant item of schedule A). 24 Material and labourfor PCC type B1 using 20mm graded crushed stone agg as in benching, coping for drain, etc including necessary form work, complete all as specified and as directed. 25 Material and labour for plain cement concrete (1:3:6) type C2using 40mm graded crushed stone aggregate as in surface channel/drain, complerte all as specified and as directed. 26 Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms moulds, mitred/stopped ends etc complete all as specified and as directed. 27 M& L for cement concrete 75mm thick type C-2, 1:3:6 (using 40mm graded stone aggregate) in plinth protection including necessary formwork complete all as specified and as directed 28 Taking down cement plaster on brick or concrete surface including racking out joints, hacking for key scrubbing down water etc and removing materials from site of work complete all as directed. 29 M & L for 10 mm thick rendering in CM (1:6) finished even and smooth without using extra cement to wall complete all as directed. 30 M&L for 5mm thick plaster rendering on fair faces of concrete surfaces as in ceiling in CM(1:3) finished even and smooth (without using extra cement) complete all as specified and as directed. 31 M&L for 15mm thick plaster of cement mortar (1:4) rendering on fair faces of brick work in two layers (10mm and 5mm thick) mixed with water proofing compound in top layer @2% by the weight of cement or as per manufacturers instructions finishing the surface even and smooth without using extra cement complete all as specified and as directed.Note : Integral water proofing compund shall be measured and paid separtely. 32 Supply onlyintegral water proofing compound complete all as specified and as directed. 33 Complete removal of existing treatment including washing, rubbing down and stopping of existing surfaces and applying two coats of exterior emulsion paint of weather coat over primer on wall surface all as specified and directed . ( Note :- Weather coat shall be approved by Engr-in-Charge) 34 M&L for complete Removal of existing treatment on walls including brooming down, applying two coats of oil emulsion distemper over and including one coat of primer and 1mm thick wall care putty complete all as specified and as directed. 35 M&L for preparing of old surfaces of wallsand applying one coat of oil emulsion distemper on the same after and preparation of internal wall surfaces, all complete as specified and directed. 36 M & L for preparation of old woodensurfaces of any description not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint (first quality), complete all as specified and directed. 37 All as per item No.33.00 here-in-before, but on steel surfaces. 38 M&L for preparation ofold decorated plastered surfaces of wall by brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc including cornices and pilasters etc and applying one coat of white wash complete all as specified and directed. 39 Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces including primer, complete all as specified and directed. 40 Material and Labours for two coat of oil bound distemper over a coat of chalk whitening on newly plastered surfaces of walls incl. necessary preparation of surfacesall as specified and directed. 41 M & L for three coats of white wash on newly plastered surface of ceiling including necessary surface preparation, complete all as specified and directed 42 Demolition of brick/stone masonary work built in cement mortar as in wall including all quoins, arches, pillars etc complete all as specified and as directed 43 M & L for brick work withsub class B old size bricks, straight or curved on plan to any radius in half brick thick wall built in CM 1:4 complete all as directed. 44 Material and Labour for brick work with sub class B bricks stright or curved on plan exc. 6m mean radius, built in cement mortar 1:6 complete all as specified and as directed. 45 S&F framed work such as grills cage for tank, gratings etc with end of bars, shouldered and/ or rivated, or forged into spikes; framed guard bars, framed work for door and windows, railing and similar work confirming to Fe 290 Gde-E-165, Complete all as specified and as directed 46 Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings . 47 M&L Prepainted galvalume zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having temsile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified. 48 M&L Prepainted galvalume zinc coating GI based Plain steel sheet 0.50mm thick of any colour having temsile strength 550 Mpa as in roof covering/cladding to wall fixed with self tapping screws as specified. 49 Demolition of Reinforcement Cement Concrete(RCC TANK) of any description and in any position complete all as specified and as directed. 50 Dismantling water tanks exc 500 ltr but n.exc 1000 ltrs capacity and removing to store complete. 51 Materials and labour for 1000 ltr capacity rotational moulded HDPE water storage tanks (Cylindrical vertical closed top),ISI Marked, white coloured, double wall construction, hoisted and fixed in position or placed in position inside or outside the bldg connecting up pipes and security access covers complete all as specified and as directed.NOTE:- Gate valve,Air pipe and union must be installed near overhead tank in outline. 52 Dismantling of ceilling boards (fibre,pulp,insulation, etc.) any thickness including cover fillets complete all as specified and as directed. 53 Supply and fix anodised aluminium snap grid frame work for false ceiling of grid size 605mmx605mm consist of anodised aluminium main/cross Tee of size 40mmx25mmx2mm, weighing 0.36kg/RM,confirming to IS 733, IS 737& IS 1285. The main and cross Tee shall be jointed at junction/crossing with anodised aluminium angle bracket of 15mmx15mmx1.5mm, weighing0.12KG/RM, fixed with suitable mild steel nut bolt & washers, snap grid frame work shall be fixed to ceiling with supporting hanger 6mm dia GI(upto 1200mm length) adjusting level fixed to roof slabs/truss by means of cleats made out of GI flat 40x3 mm size 60 mm long and expension hold fasteners 12.5 mm dia. 40 mm long complete all as manufacturer instruction fixed as specified. 54 Material and labour for Non Asbestos fibre cement building boards 4mm thick fixed or laid in aluminium frame work with screws as in ceiling complete all as directed and as directed 55 Taking down carefully copper/ Aluminum point wiring (light, fan socket or power) complete incl. (fitting such as switches, ceiling roses, pendants, regulators, sockets, boards, DB, MCB, light fittings etc), removing materials from site and making good disturbed surfaces of walls, floors etc, complete all as specified and directed 56 M & L for point wiring with PVC insulated and unsheathed multistranded FRLS insulated unsheathed 1100 volt grade multi strandedCopper conductor cable of size 1.5 sqmm drawn in and including PVC casing capingof required size with all fittings and accessories alongwith one single core FRLS insulated 1100 volt grade multi stranded FRLS Copper conductor cable of size 1.5 sqmm as earth lead and connected to earth dolly terminated into MS modular pressed steel box / PVC modular box of required size flushed in wall or on surface on faulse wall for light or Fan point or Ex Fan point controlled by one, one way switch 6/5 amp on modular white cover plate with frame of required size (modular pressed steel box, modular white cover plate with frame measured saperately) for mounting of switch complete all as specified and directed. Note: disturbed area of wall has to finish with cement mortar andmatch with existing colour of wall, rate of cement mortar and colour are inclusive in quoted rate 57 All as per item No 2 here-in-before but for one light point controled by one two way switch on the same board with other switches or independent all as specified and directed. 58 All as per item No 2 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed. 59 All as per item No 2 here-in before but for one 3 pin, 5 Amp socket point on the same board with other switch, complete all as specified and directed. 60 All as per Item No 2 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. 61 All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed 62 All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 4.0 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed 63 M&L Point wiring for one light/fan/exhaust point controlled by one switchwith two runs of FRLS grade PVC insulated unsheathed stranded copper conductor of size 1.5 Sqmm (phase & neutral) and one run of 1.5 Sqmm FRLS grade PVC insulated unsheathed strandedcopper conductor asfor earth continuity wire to be drawn in and including PVC casing & caping ( medium grade) suitable size with fittings & fixtures includingMS sheet metal switch / terminal box of suitable size duly covered with backlite sheet cover 3 mm thick or PVC box of suitable size and continuity conductor shall be connected to common earth and earth dolly and makinggood disturbed surface to walls complete all as specified & directed. Note: disturbed area of wall has to finish with cement mortar andmatch with existing colour of wall, rate of cement mortar and colour are inclusive in quoted rate. 64 All as per item No 2 here-in-before but for one bell point controled by one bell push on the same board with other switches or independent all as specified and directed. 65 All as per item No 2 here-in-before but for one light point controled by one two way switch on the same board with other switches or independent all as specified and directed. 66 All as per item No 2 here-in before but for one 3 pin, 5 Amp socket point on the same board with switch, complete all as specified and directed. 67 All as per Item No 2 here-in-before but for one switch socket outlet, 5 Amp on independent board all as specified and as directed. 68 All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 2.5 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed 69 All as per item No 2 here-in before but for one 3/5 pin, 15 Amp switch socket combination on independent board with 4.0 sqmm PVC insulated unsheathedmultistranded FRLS copper conductor, complete all as specified and directed 70 M&L forsub main wiring with 2 run of single core 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor cable drawn through and including PVC Conduit/ casing capping of required size alongwith accessories on roof/walls/ ceiling etc including one run of 6.0 Sqmm FRLS (ISI Marked) PVC insulated unsheathed multistranded copper conductor as earth wire, including taking down old wiring, complete all as specified and directed. Note :- Two run of 6.0 Sqmm single core cable, one run of 6.0 Sqmm earth wireand one run of PVC conduit/ casing capping shall be measured as one run length 71 Supply and fix modular Switchsingle pole, one way 5 Amp complete all as specified and directed. 72 Supply and fix modular Switchsingle pole, two way 5 Amp complete all as specified and directed. 73 Fixing only modular Switchsingle pole, one way 5 Amp complete all as specified and directed. (Serviceable modular Switch obtainedshall be reused) 74 Supply and fix bell push, modular type, 6 Amps, complete all as specified and directed. 75 Fixing only bell push, modular type, 6 Amps, complete all as specified and directed. (Serviceable bell push obtainedshall be reused) 76 Supply and fix modular Switch single pole, one way 15 Amp complete all as specified and directed. 77 Fixing only modular Switch single pole, one way 15 Amp complete all as specified and directed. (Serviceable modular Switch obtainedshall be reused) 78 Supply and fix modular Socket 5 Amps, 230 volts, complete all as specified and as directed. 79 Fixing only modular Switch 5 Amps, 230 volts, complete all as specified and as directed.(Serviceable modular Switch obtainedshall be reused) 80 Supply and fix modular socket, 16 amps complete all as specified and directed. 81 Fixing only modular socket, 16 amps complete all as specified and directed.(Serviceable modular Switch obtainedshall be reused) 82 Supply and fix modular fan regulator 2 module complete all as specified and directed. 83 Fixing only modular fan regulator 2 modle complete all as specified and directed.(Serviceable modular fan regulator obtainedshall be reused) 84 Supply and fix Switch piano flush button single pole, one way 6 Amp, complete all as specified and directed. 85 Supply and fix Switch piano flush button single pole, two way 6 Amp, complete all as specified and directed. 86 Fixing only piano flush button single pole, one way 6 Amp, complete all as specified and directed. (Serviceable Switch obtainedshall be reused) 87 Supply and fix bell push, flush type, 6 Amps, complete all as specified and directed 88 Fixing only bell push, flush type, 6 Amps, complete all as specified and directed. (Serviceable bell push obtainedshall be reused) 89 Supply and fix Switch socket outlet combination3 pin, 6 A flush type universalcomplete all as specified and directed. 90 Fixing only Switch socket outlet combination3 pin, 6 A flush type universalcomplete all as specified and directed. (Serviceable modular Switch obtainedshall be reused) 91 Supply and fix Switch socket outlet combination 2 in 1, 3 pin, 5 and 15 Amp flush type universalcomplete all as specified and directed. 92 Fixing only Switch socket outlet combination 2 in 1, 3 pin, 5 and 15 Amp flush type universalcomplete all as specified and directed.(Serviceable modular Switch obtainedshall be reused) 93 Supply and fix 5 stepped type electronic fan regulator flush type complete all as specified and directed. 94 Fixing only 5 stepped type electronic fan regulator flush type complete all as specified and directed. (Serviceable modular fan regulator obtainedshall be reused) 95 S&F ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. 96 Fixing only ceiling rose, surface bakelite, 65mm x 50mm, two to three terminals complete all as specified and as directed. (Serviceable ceiling rose obtainedshall be reused) 97 S&F modular white cover plate with frame of 1 Module complete all as specified and directed. 98 S&F modular white cover plate with frame of 3 module complete all as specified and directed. 99 S&F modular white cover plate with frame of 6 module complete all as specified and directed. 100 S&F modular white cover plate with frame of 8 module complete all as specified and directed. 101 S&F Metal flush box of 1 module complete all as specified and directed. 102 S&F Metal flush box of 3 module complete all as specified and as directed. 103 S&F Metal flush box of 6 / 8 module complete all as specified and as directed. 104 Supply and fixing in repair sheet metal encloser box including Plug and socket with 25 Amps MCB (SP) complete all directed.Make: Havells / Anchor / Orient 105 Supply and fix in repair PVC casing and caping of size 32 x12 mm complete all as specified and directed. 106 Supply and fixing LED lights fitting 4 feet 20 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 107 Fixing only LED lights fitting 4 feet 20 watt 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. (ServiceableLED lights obtainedshall be reused) 108 Supply and fixing LED lights fitting 2 feet 10 watt 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. 109 Fixing only LED lights fitting 2 feet 10 watt 220 V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed. (Serviceable LED lights obtainedshall be reused) 110 Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. 111 Supply and fixing of decorative, wall mounting, brushed nickel finish fixture with Opal Glass diffuser suitable with 9 W LED complete all as specified and as directed.Make: Havells cat part No. LHFOAJE1TZ1I060/ Philips wall light cat part No 919215850131/ Jaquar cat part No. DWL-CHR-MB160275531B 112 Fixing only LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed. (Serviceable LED street light fitting obtainedshall be reused) 113 Supply and fixing LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. 114 Fixing only LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed. complete all as specified and as directed. (Serviceable LED street light fitting obtainedshall be reused) 115 Material and labour for 1.5 mtr long 40 mm dia GI pipe (Light grade) bracket for fixing of street light and building light all as specified and directed 116 Disconnecting electrical wire of ceiling fan of any type / size and make, taking down from its position, dismantling blades, cleaning and greasing after removing the blade to make noise free smooth operation including painting of ceiling fans complete, in situ with synthetic enamel paint by spraying including filling cavities with filler and replacement ofpvc twin twisted wire assembling and hanging of ceiling fan and connecting up to ceiling rose or connector to fan its position using new clamp set (clamp, rubber bush and nut and bolt) including testing complete all as directed 117 Disconnecting electrical wire of Exhaust fan of size 230 / 300 mm dia and taking down from its position, dismantling blades, cleaning and greasing after removing the blade to make noise free smooth operation including replacement ofpvc twin twisted wire assembling and fixing of Exhaust fan and connecting up to ceiling rose or connector to fan its position using new fasening clamp including testing complete all as directed 118 Supply and fix sheet metal enclosure MCB DB 6 waySPN double door suitable for 240 V, fixed flushed on walls including necessary wall cuttingand making good disturbed surfaces and blanking plate as per requirement and taking down unserviceable DBs complete all as specified and directed. Note: disturbed area of wall has to finish with cement mortar andmatch with existing colour of wall, rate of cement mortar and colour are inclusive in quoted rate 119 Supply and fix sheet metal enclosure MCB DB 8 waysingle pole with neutral for 240 V, fixed flushed on walls including necessary wall cuttingand making good disturbed surfaces and blanking plate as per requirementcomplete all as specified and directed. Note: disturbed area of wall has to finish with cement mortar andmatch with existing colour of wall, rate of cement mortar and colour are inclusive in quoted rate 120 S&F miniature circuit breaker (MCBs) SPN , 240 Volt, 32 Amps, C series,10 KA breaking capacity, complete all as specified and directed 121 Fixing only MCB SPN 32 Amps complete all as specified and directed (Serviceable MCB obtainedshall be reused). 122 S&F MCB, SP, AC, 240 volts IP-43 of 6 to 32 Amps capacity C series and making connections incl taking down unsv one complete all as specified & directed. 123 Fixing MCB SP 6 to 32 Amps complete all as specified and directed (Serviceable MCB obtainedshall be reused). 124 Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanized earth wire 4 mm by means of bolt, nut, check nut and washer of galvanized iron or steel earthing lead to be protected by galvanized iron pipe of 40 mm bore light grade and other end connected to earthing test point or main controlling switch as directed including providing funnel with 20 mm bore galvanized iron pipe medium grade for watering wire mess all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion as directed.