Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 04-08-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 09-08-2025 |
| 2 | 28-07-2025 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 04-08-2025 |
| 3 | 10-07-2025 | CORRIGENDUM TO TENDER | Other | 28-07-2025 |
| Sl. No. | Item Description |
| 1 | M & L for seven stage cleaning and sterlization of inside OHT reservoir of capacity 50000 Gallons through bacterioligical treatment by using TERBAC G5, TERBAC-G-65 and ULTRA VOILET ray through authorized agency, complete all as specified and directed. Process of seven stager are as under :-1. First stage is to draining out the water by using exist valve or high capacity dewatering system.2.Second stage is cleaning all the algae formation inside the tank by using TERBAC G10 a laboratory tested branded chemical of the company and scrubbing the walls of the tanks.3. Third stage is fresh water cleaning by high speed jet pump with pressure 5 PSI. 4. Fourth stage and first bacteria screening is decertification by using TERBAC-G5 a GovtLaboratory certified brannded halogen compound.5. Fifth stage is cleaning the floor of water tank by heavy duty industrial vaccum cleaner.6. Sixth stage is the secord bacteria screening and sterilizing method by using ultra voiletray ejector covering 360 degree within the tank and kills all suspended bacteria.7. Seventh stage of cleaning and third bacteria screening is to sterilize the floor of the water tank by using laboratory certified, branded strong oxidizing agent TERBAC-G65Note: Company will submit govermnet laboratory test certificate of TERBAC-G5, TERBAC-G65, Fix the sticker mentioning the date of cleaning and name of site and also provide certificate confirming the completion of steriliztion of water tanks mentioning name of the station and date of cleaning.(Name of agency/company : Rays cleantech or equivalent agency as approved by GE.) |
| 2 | All as per Item No. 1.00 here-in-before but for OHT reservoir capacity 30000 Gallons, complete all as specified and directed |
| 3 | S&F in repair air termination single pointed aluminium rod 12mm dia and 300mm long with necessary fixing arrangement on roof, complete all as specified and directed. |
| 4 | S&F in repair aluminium strip 25 x 3.00mm with saddles and fixing screws etc. for roof conductors and down conductors above ground, complete all as specified and directed |
| 5 | S&F in repair porcelain vitreous white/brown/green spacers insulator of size 75mm x 35mm x 40mm height complete with one number galvanized iron stud bolts 6mm dia x 40mm long including nut & washers and two number galvanized iron fixing bolts of size 6mm dia and 50mm long including washers and drilling holes for holding /foxomg aluminium strip/roof conductor as required, complete all as specified and directed. |
| 6 | Supply, installation and testing smart digital 10-levels % indicator, stage type, with mechanism to detect & display the water level in an underground/ overhead tank, corrosion & maintenance free magnetic sensors, buzzer alarm sounds on low & high Levels including necessary fittings, complete all as specified and directed. |
| 7 | S&F PVC insulated & sheathed stranded copper (FR) cable 3 core of cross sectional area 2.5 Sqmm for providing necessary electrical connection from junction box to light fittings with suitable size copper lugs including taking down existing cable, complete all as specified and directed. |
| 8 | S&F PVC insulated & sheathed stranded copper (FR) cable 3 core of cross sectional area 1.5 Sqmm for providing necessary electrical connection from junction box to light fittings with suitable size copper lugs including taking down existing cable, complete all as specified and directed. |
| 9 | S&F in replacement offirst aid kit box/emergency medical boxwall mouted type made out of powder coated GI sheet of 18 gauge and the size of the box will be 36cm(H) x 26cm(W) x 13 cm(D) with front transparent acrylic glass and multi compartment 4 shelf for better organize of medicines with security lock on door, openable window at front side with help of hinge at one side and locking arrangement at another side, openable window must painted with \"FIRST AID\" with red paint and whole box will fixed on wall at height not less than 2mtr including medicene and other items as under :- (i) Sterilized dressings- 04 Nos, (ii) Cotton Wool 10 gm - 02 Nos, (iii) Antiseptic Solution (100 ml) - 01 No, (iv) Burn Ointment - 01 No, (v) Scissor - 01 No, (vi) Digital Thermometer - 01 No, (vii) Disposal Gloves - 02 Nos, (viii) Disposal Mask - 20 Nos, (ix) Adhesive / Microporous Tape 1/2\" - 01 No, (x) Band- Aid - 10 Nos, (xi) Safety pins - 05 No, (xii) Cold Rub - 01 No, (xiii) Roller Bandage (5cm) - 02 Nos, (xiv) Roller Bandage 10 cm - 02 Nos, (xv) Cotton Buds - 10 Nos, (xvi) Hand Sanitizer - 02 Nos, (xvii) Handiplast - 12 Nos, (xviii) Antiseptic cream - 01 No, (xix) Antiallergic medicene, Cough medicene, Pain killer, Fever and cold medicene- 01 strip each and a First-Aid Guide booklet, complete all as specified and directed. |
| 10 | Uprooting grass/weeds/plants up to 30cm depth by scrapping soil in order to make free ground from all sort of vegetation and hand packing carefully by packing round pebbles approximately of size 20 to 40mm after carefully picking form heap of pebbles/stones, complete all as specified and directed. |
| 11 | Supply and spreading unslaked lime at surrounding (avarage 300 gms per Sqm), complete all as specified and directed. |
| 12 | M&L for testing the raw/treated water and submit following test report from Govt. approved Lab and its physical, chemical and biological analysis report to know the quality of drinking water in every three month or as and when required, as directed, including the followings:-(a) Collection of 09 Nos of samples of raw water/treated water from each location i.e. (new pump house, NCE\"s pump house, KV pump house No-1, RS pump house, Tech pump house, Nala post pumphouse, Arjan pump house and KV pump house No-II, IMTRAT pump house) as directed. (b) Submit/deposit all samples at the nearest Govt approved test lab. The test for the following parameters shall to be carried out:-(1) Turbidity (ii) PH Level (iii) TDS (iv) Colour (v) Alkalinity (vi) Hardness (vii) Iron (viii) Chloride (ix) Chlorine (x) fluoride (xi) Nitrate (xii) Copper (xiii) Colliform (xiv) Feacel Colliform (c) Submit the test report duly signed by appropriate authority.(Note: Cost for collection of samples, test tube/flask and trasportation to LAB deemed to be included in the unit rate) |
| 13 | M & L for PCC (1:3:6) type C2 (using 40mm graded crushed stone aggregate) for foundation, filling, mass concrete, making good to disturbed surfaces of road/hardstanding/path etc, complete all as specified and directed. |
| 14 | M&L for cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size (for fixing of DI pipes in bridge etc) as indicated and inclusive of one primer coat and one coat of aluminium paint including taking down old unserviceable cross arms/bracing etc, complete all as specified and directed. |
| 15 | M & L for prepration of old painted DI/CI pipe, any gauge and applying two coats of synthetic enamel paint (1st grade quality) with colour coding of riser pipe, deliver pipe, overfloow pipe, drainout pipe etc, size upto 80 to 100mm bore, complete all as specified and directed.Note- Arrangement of tools and sefty equipment for painting of pipe hight upto 25 meter OHT shall deemed to be included in the unit quoted rate. |
| 16 | All as per Item No. 15.00 here-in-before but size upto 150 to 200mm bore, complete all as specified and directed |
| 17 | S&F LED type integral aviation obstruction light (Heavy duty) IP 65/66, single light fitting comprising of Die-cast aluminum housing with Red polycarbonate dome for better illumination, integral driver, Supper flux 5mm 302nos LEDs incorporated, powder coated aluminium housing with polycarbonate enclosure including taking down unserviceable aviation light fittings, complete al as specified and directed. |
| 18 | M & L for construction of brick masonry valve pit chamber of internal dimension 1200mm x 1200mm x 1200mm depth with sub class \"B\" bricks, old size in CM (1:4), full brick thick wall and 10mm thick rendering on internal and extranal surfaces both in CM (1:4), 15mm thick PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation, PCC (1:2:4) type B1 (using 20mm graded crushed stone aggregate) as in copping, MS frame work with 50 x 50 x 6mm angle iron, 5mm thick MS sheet cover with locking arrangement including 50mm pad lock with double key arrangement, including painting of steel surface with two coats of synthetic enamel paint over a coat of red oxide primer, three coat of white wash on plastered surface (exposed to view) incuding necessary excavation in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 mtrs including demolition of existing cracked valve chamber, complete all as specified and directed. |
| 19 | All as per item No 18.00 here-in before but internal dimension 900mm x 900mm x 900mm depth, complete all as specified and directed |
| 20 | S&F 150mm bore sluice, valve flanged end of class PN (1.6), confirming to IS-14846 with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc. including taking down old unserviceable sluice valve, complete all as specified and directed. |
| 21 | S&F 100mm bore sluice, valve flanged end of class PN (1.6), confirming to IS-14846 with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc. including taking down old unserviceable sluice valve, complete all as specified and directed. |
| 22 | S&F 80mm bore sluice, valve flanged end of class PN (1.6), confirming to IS-14846 with brass spindle and hand wheel including necessary gasket, nuts and bolts, washer etc. including taking down old unserviceable sluice valve, complete all as specified and directed. |
| 23 | S&F in repair energy saving 100W LED 6000K, IP 65 protection flood light luminaire with high power LED including provision of PVC insulated sheathed round flexible wire with multi strand copper conductor, complete all as specified and directed |
| 24 | S & F 250mm bore CI vertical check valve, flanged end, ISI marked, including taking down old unserviceable valve, complete all as specified and directed. |
| 25 | Taking out existing unserviceable/defective light fitting / high bay light fitting of any wattage from poles/walls/ high mast (including taking down of high mast fitting), dismantling the complete fittings of and checking out the defects, trace out damage/unserviceable parts like driver, wire, led lamp etc. and clean thoroughly the complete set and re-fixing in its original position after replacing defective parts including testing, complete all as specified and as directed.Note :- (i) Any minor item like nuts, bolts, clamps, washers and wires for connection required to make the fitting serviceable shall deemed to be included in the unit quoted rate. (ii) Defective parts replaced shall be paid as \"supply only\" under relevant items. |
| 26 | S&F brackets on pole made out of 40mm bore GI pipe, medium grade of required length not less than 1.20 M including mounting brackets made out of mild steel FI 40 x 6mm of required shape (two Nos per Gl pipe brackets) duly fitted with 4 Nos mild steel nuts, bolts and washers in walls/poles etc. and painting with two coats of synthetic enameled paint over one coat of red oxide zinc chrome primer including taking out existing unserviceable GI bracket of any size & shape, complete all as specified and directed. |
| 27 | S&F astronomical time switch in existing street light timer panel for switching on/off lights and other electric devices according to the sunrise/sunset times based on the entered location or location coordinates including taking down old unserviceable time switch, complete all as specified and directed. |
| 28 | S&F in repair of contactor TP, 40 Amp, complete all as specified and directed. |
| 29 | S&F in repair of contactor TP, 50 Amp, complete all as specified and directed. |
| 30 | S&F in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, fixedin proper position, complete all as specified and directed. |
| 31 | Cleaning of creepers from electric pole, Junction box and street light including replacement of cable gland, lugs, tightening of earthing & orientation of street light bracket properly, complete all as specified and directed.Note : Rates for cable gland, lugs / thimble shall deemed to be included in the unit quoted rate. |
| 32 | S&F LED street light fittings 45 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. |
| 33 | S&F LED street light fittings 60 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. |
| 34 | S&F LED street light fittings 90 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. |
| 35 | S&F LED street light fittings 120 watt 230 v AC outdoor type with high pressure dia cast aluminium housing and heat-resistant complete with driver, lamp bracket with impact and corrision resistant, IP 65/66 protection including taking down old unserviceable LED light fittings, complete all as specified and directed. |
| 36 | Supply and fixing KIOSK box (junction box) weather proof made out of PVC and including one piece mounted SMC base and door pole mounted hinged door size 333 x 233 x 200mm out side and 300 x 200 x 105mm inside dimension comprising of aluminum bus bar 4 strips for 3 phase and neutral 63 Amp and 10 Amp MCB for controlling the street light fitting including Fl clamps 30 x 4mm with necessary MS bolts and washer including notice of size not embossing/painting of danger notice of size not less than 10cm x 7.5cm with letters, figures and conventional skull and bones in signal red colour on front face of KIOSK box body including taking down old unserviceable box, complete all as specified and directed. |
| 37 | Supply only OEM LED driver suitable for 45-50 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 38 | Supply only OEM LED driver suitable for 60 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 39 | Supply only OEM LED driver suitable for 90-120 watts LED outdoor (Flood light/Street Light) luminaries, complete all as specified and directed. |
| 40 | Excavation in trenches not exceeding 1.5 metre wide and not exc. 1.5 metre in depth for foundation of pole / stay, or cable trenches and getting out in soft/loose of any type of soil. complete all as specified and as directed. |
| 41 | Returning filling in including spreading, leveling watering and well ramming in layers not exceeding 25cm in soft loose of any type of, soil complete all as specified and directed. |
| 42 | Removing excavated materials to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 metre above thestarting point, all as specified and as directed. |
| 43 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 40mm outer dia conforming to IS, approved colour, complete with fittings for cable protection, complete all as specified and directed |
| 44 | Supply and laying double walled corrugated (DWC) HDPE duct pipe of 50mm outer dia conforming to IS, approved colour, complete with fittings for cable protection, complete all as specified and directed |
| 45 | Demolition of un-reinforced cement concrete of any description not otherwise specifically provided for and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100m, complete all as specified and directed. |
| 46 | M&L for PCC(1:2:4) type B-2 (using 20mm graded crushed stone aggregate) as in coping of poles, mounting air termination rod etc. including formwork (as required), complete all as specified and directed. |
| 47 | M & L for PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation of poles/struts etc., including form work, complete all as specified and directed. |
| 48 | Horizontal boring under the road below 1mtr from the road surface and dial of hole not exc. 100mm, without damaging the existing road, getting out and disposal of soil to a distance not exceeding 50m from the site of work, complete all as specified and directed. |
| 49 | M&L for galvanized iron tubing 40mm bore (light grade) with all fittings for protection of cables, laid in trenches, including taking down old unserviceable GI pipe, complete all as specified and as directed.(Note : Excavation and earth work shall be measured and paid separately ) |
| 50 | Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size16 sqmm 4 core including taking down old unserviceable UG cable, complete all as specified and directed. |
| 51 | All as per serial item No. 50.00 here-in-before but 35 sqmm 3.5 core, complete all as specified and directed. |
| 52 | All as per serial item No. 50.00 here-in-before but 50 sqmm 3.5 core, complete all as specified and directed. |
| 53 | All as per serial item No. 50.00 here-in-before but 95 sqmm 3.5 core, complete all as specified and directed. |
| 54 | M & L for danger notice sticker of size 8cm x 8cm, made out of industrial grade vinyl film with UV protected layer, suitable for external use, self adhesive including signage for electric danger with bones and skull, 415 volts etc, complete all as specified and directed |
| 55 | M&L for painting steel tubular poles, 7-9.0 meter in height above GL including cross arms & bracings on existing surface after cleaning and removing dust, rust & dirt with one coat of red oxide primer and two coat of aluminium paint and painting with black & white alternate strips of 30cm each externally from ground level up to 1.5 mtr with synthetic enamel paint, numbering of pole (MES/SL Number) and white wash on pole coping, complete all as specified and directed. |
| 56 | M & L for removing of flashed carbon from distribtion box/LT panel any type and size by cleaning with cleaning agent properly and replacement of burnt out parts like spreader link, bottle lugs, of suitable size, complete all as specified and directed. |
| 57 | Supply, fabricating, installing, testing and commissioning of outdoor type LT bus bar box, factory made, of size not less than 900mm (L) x 900mm (b) x 450mm (d) of suitable size factory fabricated, cubical panel, floor mounted double door, dust and vermin proof CPRI approved made out of 3.15 mm thick CRCA sheet mounted on 40 x 40 x 5mm angle iron supports at the base duly painted withsynthetic enamel paint (spray painting) and panel board with front and back opening and locking arrangement compete including finishing with two coats of powder coated paint of approved shade over one coat of red oxide zinc chrome primer including all busbar of copper strip 40mm x 10mm for three phase 4 wire 415 Volts, 50 Hz, AC supply, including suitable size cable glands, lugs etc, in proper arrangement for ventilation, including taking down of old unserviceable bus bar box, complete all as specified and directed |
| 58 | M&L for earthing complete with galvanised steel earth plate electrode 600mm x 600mm x 6.0mm thick burried directly in gorund (earth pit not less than 2.25 Mtr normal ground level),and top edge of earth plate not less than 1.5 mtr below normal ground level, connected to galvanisedmeans of earth wire 4mm dia with bolts, nuts & check nuts, and washers of galvanised iron protection pipe light grade of 20mm bore and GI pipe, medium grade, of 15mm bore for watering and filled with alternate layer of charcoal and common salt, watering funnel with wire mesh, earth pit chamber and cover CI frame PCC (1:3:6) type C-2 all as shown in electrical plate No-3 of SSR part-I of 2009 connected to earthing test point all as specified and indicated including all earth work excavation, returning filling and disposal of surplus soil and testing on completion, complete all as specified and directed.Note : (i) Proper earthing pit should be provided with pit cover.(ii) GI earth wire from earth pit to pole/panel/DB shall demed to be included in the unit quoted rate. |
| 59 | M&L for earthing complete with GI earth plate elecrode of size 600mm × 600mm × 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to GI earth strip 32mm x 6mm by means of bolts, nuts, check nuts and washers of brass or HS steel all as shown in electrical plate No. 3 connected to earthing test point and and necessary excavation and earth work pre-cast RCC(1:2:4) type B-1 pit cover 50mm thick, reinforced with 8mm dia TMT bars @100 mm /C/C both ways with one handle for lifting made out of 10mm dia TMT bar embedded in precast cover slab and PCC(1:2:4) type B-1 concrete pit and angle iron frame and opening arrangement ) incl providing charcoal or coke and common salt in alternate layer of 15cm compacted thickness all around the earth electrode with funnel and 20mm bore galvanized iron watering pipe (medium grade) wire mesh, copper lugs, complete in all respect, protected by 40mm bore (light grade) galvanized iron pipe up to earthing test point, incl disposal of spoil to a distance not exc 50 mtr and necessary testing on completion, complete all as specified and as directed.Note: (i) Proper earthing pit should be provided with pit cover.(ii) GI strip from earth pit to pole/panel/DB shall demed to be included in the unit quoted rate. |
| 60 | S&F MCCB 63 Amps AC 4 pole 415 Volt 16 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 61 | S&F MCCB 100 Amps AC 4 pole 415 Volt 16 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 62 | S&F MCCB 125 Amps AC 4 pole 415 Volt 16 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 63 | S&F MCCB 160 Amps AC 4 pole 415 Volt 25 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 64 | S&F MCCB 200 Amps AC 4 pole 415 Volt 25 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 65 | S&F MCCB 250 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 66 | S&F MCCB 315/350 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 67 | S&F MCCB 400 Amps AC 4 pole 415 Volt 36 KA breaking capacity as per IS/IEC 60947-2with thermal magnetic releaseincluding providing new thimble / lugs of suitable size andtaking down old unserviceable one, complete all as specified and directed. |
| 68 | S&F in repair MCB Single Pole & Neutral (SPN) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 69 | S&F in repair MCB Tripple Pole Neutral(TPN) of capacity 40 to 63 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixedin proper position, complete all as specified and directed. |
| 70 | S&F MCB distribution board (DB), TPN with sheet metal encloser, double door, IP 43 protection & IK 09, 240 volts, 4 way, as per IEC 61439-3 with necessary lugs for incomming and outgong connections, fixed on wall or concealed with 200 Amps rated busbar (as per OEM), neutral link for fixing MCBs/Isolators including taking down old unserviceable MCB DB of any rating, complete all as specified and directed. |
| 71 | S&F RCBO for earth leakage, over load and short - circuit protection 32 Amp, DP, 100 mA, completes all as specified and directed. |
| 72 | S&F RCBO for earth leakage, over load and short - circuit protection 40 Amp, DP, 100 mA, completes all as specified and directed. |
| 73 | M&L for maintenance of LT ACB of rating up to 630 Amp 415 Volt 50 Hz of any make installed at LT panel boards complete by taking the shut down with prior intimation and cleaning the ACB by using air blower tightening of control circuit and complete checking of all fuses, checking relay and control circuit for smooth functioning by employing one skilled tradesman and when required and also to carry out following works :- (i) Check and clean incoming and outgoing terminals / compartment.(ii) Checking the serviceability of close and trip coil condition and taking out for replacement.(iii) Checking the serviceability of control circuit, relays, fuses and Electrical/mechanical interlocks.Note: (i) Replacing the spares such as shunt release, UV release tripping/ closing coil shall be measured and paid separately under respective item.(ii) Unit rate shall deemed to be included for preventive maintenance/ attending break down as and when required.(iii)Cost of replacing small piece control circuit wires up to 1.00 Mtrs, LT fuses and Push buttons for ON/Off, if required, shall deemed to be included in the unit quoted rate. |
| 74 | S&F in replacement shunt trip for LT ACB, 415/240 Volt, AC up to 630 Amp, completes all as specified and directed. |
| 75 | S&F in replacement voltage under release, 415/240 Volts, suitable for LT ACB of rating upto 630 Amp, as per existing, completes all as specified and directed. |
| 76 | S&F current Transformer of rating CT ratio 200/5 Amp, indoor type, insulated ring type in existing panel including taking down old unserviceable CT’s of any make/rating, complete all as specified and directed. |
| 77 | S&F current Transformer of rating CT ratio 500/5 Amp, indoor type, insulated ring type in existing panel including taking down old unserviceable CT’s of any make/rating, complete all as specified and directed. |
| 78 | S&F change over switch 63 Amp with sheet steel enclosure including source seperator/phase barrier including providing new thimble/lugs of suitable size including taking down old unserviceable one, complete all as specified and directed. |
| 79 | S&F change over switch 100 Amp with sheet steel enclosure including source seperator/phase barrier including providing new thimble/lugs of suitable size including taking down old unserviceable one, complete all as specified and directed. |
| 80 | S&F in repair 3 pole power contactors, 40 Amp , ML- 3 ,2 NO+2 NC power contactors for street light and connecting new contactors and making connection with incoming and outgoing MCCB/MCB including taking down old unserviceable panel, complete all as specified and directed |
| 81 | S&F in repair 3 pole power contactors, 70 Amp , ML- 4 ,2 NO+2 NC power contactors for street light and connecting new contactors and making connection with incoming and outgoing MCCB/MCB including taking down old unserviceable panel, complete all as specified and directed |
| 82 | S&F in replacement timer for 24 hrs, complete all as specified and directed. |
| 83 | S&F weather proof junction box made from SMC sheet ready made of size 350 x 270 x 210mm with aluminium bus bar of 150 Amp capacity for RYB and neutralfixed inside the junction box with necessary supporting insulators fixed on hylem sheet /insulating sheet ,MS sheet steel fixed inside the bottom portion of box to connect the cable gland complete , entire assemblyfixed to pole /wall with MS clamp 25 x 5mm and nuts & bolts,and connecting cables from junction box to fittings, complete all as specified and directed. |
| 84 | All as per item No. 83.00 here-in-before but size400 x 300 x 190mm and bus bar capacity 200 Amps, complete all as specified and directed. |
| 85 | Note: An amount of Rs.37,450.00 on account of Credit Schedule for schedule \"A\" part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. |
| 86 | Supply and fixing energy efficient ‘LED Flood Light120 W LED luminairewith Aluminium dia cast housing, toughened glass cover with IP 66 protection, CCT 5700 K including fixing arrangment on wall/pole / surface and connecting cable up to nearest ceilign rose into flexible PVC conduit. Make : Crompton/Havells/ Surya/Philips |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail