}

Tender For Repair And Replacement Of Unsv Street Light,Flood Light,Timer Panel And Other Connected Items At Zone-I And Zone Ii Under Age(I) Lansdowne, lansdowne-Uttarakhand

Military Engineer Services has published Tender For Repair And Replacement Of Unsv Street Light,Flood Light,Timer Panel And Other Connected Items At Zone-I And Zone Ii Under Age(I) Lansdowne. Submission Date for this Tender is 28-07-2025. Street Lighting Tenders in lansdowne Uttarakhand. Bidders can get complete Tender details and download the document.




Tender Notice

50000713
Tender For Repair And Replacement Of Unsv Street Light,Flood Light,Timer Panel And Other Connected Items At Zone-I And Zone Ii Under Age(I) Lansdowne
Tender
Indian
Uttarakhand
Lansdowne
28-07-2025

Tender Documents

Tender Details

Tender For Repair And Replacement Of Unsv Street Light,Flood Light,Timer Panel And Other Connected Items At Zone-I And Zone Ii Under Age(I) Lansdowne; 1 Excavating in trenches nexc 1.5 m width and nexc 1.5 m in depth for foundation or for shafts, well cesspits, manholes etc / for laying of cable/ pipe etc nexc 10 sqm on plan and nexc 1.5 m in depth and getting out in hard/dense soil complete all as specified and directed. 2 Description same all as per item No 1 above but for each additional 1.5m or part thereof in depth beyond the first 1.5m in hard/dense soilcomplete all as specified and directed. 3 Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm.complete all as specified and directed. 4 Removal of surplus soil to a distance nexc. 50 Mtr and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed. 5 M&L for sand cushioning with dry and clean fine river sand for underground cable 8 cm before laying cable and 15 cm after laying and punned to 18 cm after laying of cablecomplete all as specified and directed.Note:- Punned thickness shall be considered for payment purpose. 6 Supply and laying cable protection bricks, common burnt clay sub class B designation 75 for protection of UG cable laid in trenches with axis of the bricks perpendicular to the axis of the cable complete all as specified and directed. 7 M&L for PCC (1:4:8) Type D2 (40 mm graded aggre-gate) as in foundations, filling and mass-concrete or sub base of floor/ hard standing/ footpath complete all as specified and directed. 8 M&L for PCC (1:3:6) type C1 (20 mm graded stone aggregate) as in coping, roof kerb, cill, bed block, block for insertion of hold fast of door and window with and including formwork complete all as specified and directed. 9 Dismantling and taking out old unserviceable Tubular poles and struts of any sizecomplete all as specified and directed. 10 Dismantling and taking down bend/damaged mild steel work such as cross arms, bracing, supported, clamps & back plates etc complete all as specified and directed. 11 Dismantling insulators any type, any size complete all as speified and directed. 12 Dismantling stay assembly complete (demolition of concrete, etc. and excavation measured separately) 13 Dismantling of ACSR conductors, any size complete all as speified and directed. 14 Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 10 Sqmm 2 core incl taking out old unsv cable from trenches all as specified and as directed. Note :- The earth work, GI pipe & Clamp for suitable size to hold the cable on wall shall be measured and paid separately under appropriate item of Sch A 15 All as item No 14 above but 16 Sqmm 4 core complete all as specified and directed. 16 Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 40mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. 17 Disconnecting and taking out old unserviceable GI Pipe and Supply, laying & jointing GI water tubing 50mm bore, light grade as in sleeving etc laid in trenches/pole post/under culvert/under road etc complete all as specified and directed. 18 Supplying, transporting, erection & fixing of new steel tubular swaged poles type 410 SP-31, (9.00 metres long), with cast iron base plate, finial taper plug, bolts, nuts and screws complete as specified with and including two coats of aluminium paint over a coat of red oxide primer on all exposed surfaces and tarring with black bituminous paintsto portion embeded in PCC with and including all necessary excavation & earth work in any type of soil for foundation of poles, PCC 1:3:6 type C2 (using 40 mm graded stone aggregate ) in foundations of size600 X 600 X 1650 mm belowGL, PCC 1:2:4 type B2 (using 20 mm graded stone aggregate) in plinth block(coping) of size 600 X 600 X 300 mm above GL , removing surplus soil to a distance n. exc. 50 m & depositing where directed, and writing numbers of poles in 100 mm dia yellow colour circle with black paint including 30 cm wide alternate black bands (03 Nos) upto 1.5 height from top of copingcomplete all as specified and directed. 19 M&L for cross arms, bracings, supports, clamps and back plates fabricated from steel section including nuts, bolts, washers, welding bending cold or hot drilling holes for bolts in any shape or size as indicated or directed and inclusive ofone primer coat, one under coat and one finishing coat of synthetic aluminium paint. 20 M&L for Pin type, porcelain, vitreous, white, brown or green insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, 100mmheight, 65mm dia for 1100 volts grade complete all as specified. 21 M&L for shackle type insulators of 100mm high, 115mm dia porcelain, vitreous, white, brown or green insulators for working pressure 1100 volts including mild steel straps of size 31x5mmincluding 14mm dia bolts complete all as specified. 22 Supply & Fixing stay assemblycomplete with all accessories, such as stay plate 300x300x6mm, stay rod 215cm long and 16mm dia with nuts including GI Bow turn buckle etc, all as per Electrical Plate No 1 SSR-2009 Part-I complete all as specified and directed. (Necessary excavation and PCC and one set of stay clamps at top of pole & loop insulator of size 90x140mm porcelain, vitreous, white, brown or green shall be measured and paid seperately) 23 S&F Galvanised stay wire of size 7/4mm all as specified and directed. 24 M&Lforloop type insulator porcelain vitirious porcelain white, brown or green large size with overall dimensions 90 x 140 mm clearence of hole 25.5mm complete all as specified and directed. 25 Supply, streching and fixing of over head ACSR conductor of any size drawn straight horizontal on over head lines on poles including binding with insulators, jointing jumpers etc including connections of incoming and out going cables complete all as specified and directed. 26 Trimming up of tree branches upto 3 mtr all around LT overhead lines, removing cut branches from site as directed, Note :- (i) The overhead lines will be kept clear from all trees by trimming of tree branches with 3 mtr all around the line. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. (ii) Total length of line from supply point to load end will be measured for the purpose of payment, irrespective ofthe No of trees required to be trimed. (iii) Fortnightly inspection of lines will be made jointly by contractor or his authorised rep and rep of Engr-in-Charge and out come whether lines are free from tree branches or notkept on record for payment. No payment is made for whole length if even single tree is within reach of OH line. (iv) The OH line will be maintained for whole period of contract and the payment will be made with final bill only. The payment for the period for which line not maintained will be deducted proportionately based on fortnightly inspection carried out as detailed above. (vii) Quoted rates shall deemed to be included use of T&P. One span comprises of distance between one pole to another including all trees in its vicinity including switch off/on, electric cable connection or disconnection. Necessary permission will be obtained from department by contractor one day prior to trimming in particular area and shut down of that area will be arranged by department. 27 S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 160 Amp breaking capacity 36 KA complete, including terminal links of suitable amp rating and size all as specified and directed. 28 S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 100 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed. 29 S&F in repair of MCCB 4 pole, 415 volt, adjustable thermal and magnetic release type 63 Amp breaking capacity 16 KA complete, including terminal links of suitable amp rating and size all as specified and directed. 30 S&F in repairs/replacement MCB, SP, AC, 240 volts of 06 to 32 Amps capacity 10 KA, C Series and making connections with suitable size of copper lugs complete all as specified & directed 31 S&F in repairs/replacementMCB, SPN, AC, 240 volts of 40 Amps capacity 10 KA, C Series and making connections with suitable size of copper lugs complete all as specified & directed 32 Supply, laying and fixing or passing in repairs through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium stranded conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 10 sq. mm 2 core all as specified and as directed. 33 M&L for replacement ofheat shrinkable end termination cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size upto 16 sqmm 4 core 1100 Volts gardefor indoor/outdoor use complete with jointing materials and accessories. Make: Raychem/3M/Densons 34 M&L for replacement ofheat shrinkable end termination cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size 25 to 50 Sqmm 3.5 core 1100 Volts gardefor indoor/outdoor use complete with jointing materials and accessories. Make:- Raychem/3M/Densons 35 All as per item No 34 above but electric cable of size 70 sqmm to 150 Sqmm 3.5core 36 All as per item No 34 above but electric cable of size 185 sqmm to 300 Sqmm 3.5core 37 All as per item No 34 above but electric cable of size 400 sqmm to 500 Sqmm 3.5core 38 M&L for replacement ofheat shrinkable straight through cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size 185 to 240 Sqmm 3.5 core 1100 Volts gardefor indoor/outdoor use complete with jointing materials and accessories. Make:- Raychem/3M/Densons 39 M&L for replacement ofheat shrinkable straight through cable jointing kit for PVC/XLPE insulated ,armoured electric cable of size 300 to 400 Sqmm 3.5 core 1100 Volts gardefor indoor/outdoor use complete with jointing materials and accessories. Make:- Raychem/3M/Densons 40 M& L for replacement of Cable lugs with aluminium alloy tubular bimetallic terminals of size 10 Sqmm incl crimping with help of crimping tools all as specified and directed .Make :- Dowells/Jainsons or equivalent 41 All as per item No 40 above but of size 16Sqmm 42 All as per item No 40 above but of size 25sqmm 43 All as per item No 40 above but of size 35Sqmm 44 All as per item No 40 above but of size 50 Sqmm 45 All as per item No 40 above but of size 70 Sqmm 46 All as per item No 40 above but of size 95 Sqmm 47 All as per item No 40 above but of size 120 Sqmm 48 All as per item No 40 above but of size 185 sqmm 49 All as per item No 40 above but of size 240 Sqmm 50 All as per item No 40 above but of size 300 Sqmm 51 All as per item No 40 above but of size 400 Sqmm 52 Scraping of old paint from the steel tublar pole 9 mtr hight without removing accessories and Preparation surfaces for repainting. Repainting the pole with one coat of alternate black and yellow strips of 30 cm upto height of 1.5 mtr using synthetic enamel. Marking the pole number with black enamel paint. Repainting the remaining poleand iron parts steel cross arms i.e U clamps etc above 1.5 Mtr height by applying two coat of synthetic enamel aluminium paint all as required at site and as directed. 53 Supply and fixing in repairs LED Street Light fitting60 watt 230 V AC outdoor type with high pressure die cast aluminium hosing and heat resistant complete with driver, lamp bracket with impact and corriosion resistant including thermal management in multiple optics complete with IP 65/66 protection,including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed . 54 Supply and fixing in repairs LED Flood Light 150 watt230 V AC outdoor type with thermal management in multiple optics and equiped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp, including fixed on pole of any type on existing angle iron with help of nuts bolts washer including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed . 55 Supply and fixing in repairs LED Flood Light 250 watt230 V AC outdoor type with thermal management in multiple optics and equiped with IP 66 protection, with impact and corrosion resistant complete with driver and lamp, including fixed on pole of any type on existing angle iron with help of nuts bolts washer including connecting with 1.5 sqmm, 3 core, PVC insulated copper conductor cable 1100 Volts grade from pole box to light or from overhead conductor to light complete all as specified and as directed by Engr-in-Charge. 56 Supply and fixing in repair bracket made out of 32mm bore, steel tubings, galvanised, light grade not less than 1.2 mtr long bend to shape with all fitting including fixed on pole with 02 Nos MS Clamp made out of F1 32x6mm complete all as specified and as directed 57 S&F in repair thermoplastic cable junction boxes/enclosure (Distribution Box) for outdoor installation with knockouts for cable entry suitable for cable size 16 to 25 Sqmm of dimension 200mmx140mmx95mm with cable terminals complete fitted on pole with suitable size of MS Clamps F1, nuts, bolts and washers, 01 No MCB SP 6 Amp and painting with two coats of synthetic enamelled paint over one coat of red oxide zinc chrome primer on clamps complete all as specified and directed. 58 S&F in repair thermoplastic service connection boxes/enclosure (Distribution Box) having busbar with screw bolt connection through fly nut for outdoor installation with knockouts for cable entry suitable for cable size 16 to 25 Sqmm of dimension 450x375x200mm with cable terminals complete fitted on pole with suitable size of MS Clamps F1, nuts, bolts and washers and painting with two coats of synthetic enamelled paint over one coat of red oxide zinc chrome primer on clamps incl connections of existing service cables with suitable size of thimblescomplete all as specified and directed. 59 Supply and fixing in repairs/replacement of XLPE insulated AB Cable 1100 Volts 3 Core x 120 Sqmm (insulated phase conductors) + 1 x 95 Sqmm (insulated neutral messanger conductor) + 1 x 16 sqmm (insulated conductor for street light connections) ISI marked on 09 mtr LT Steel tubular poles incl refixing of existing serviceable street lights with all required accessories complete all as specified and directed . 60 Supply and fixing in repairs insulation piercing connectors (IPC) for main/service/street light connections for cable of 16-120 Sqmm with taps ranging from 50-120 Sqmm IPC type 002 complete all as specified and directed and confirming to relevant IS complete all as specified and directed. 61 Supply and fix in repair anchoring clamp with aluminium alloy bracket stainless steel strap, buckles eye hook incl nuts and bolts and washers confirming to relevant IS complete all as specified and directed. 62 Supply and fixing in repairs suspension clamp with aluminium alloy bracket stainless steel strap buckles, eye hook incl nuts and bolts and washers confirming all as specified and directed. 63 Supply and fixing end cap for cable 120 Sqmm three core + 95 Sqmm and one core + 16 Sqmm one core and confirming to relevant IS complete all as specified and directed. 64 Supply and fixing in repair LED driver with PF>0.95, input voltage 240V AC, 50 Hz, input current 0.25 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line voltage 140 to 277V, IP 20 protection as per IS:15885 (part-II section 13) suitable for LED street light of 25-45 watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by Engr -in-charge complete all as specified and directed. 65 Supply and fixing in repair LED driver with PF>0.95, input voltage 240V AC, 50 Hz, input current 0.25 Amp AC, output voltage 42V-72V DC, output current 0.7A DC THD<10%, line voltage 140 to 277V, IP 20 protection as per IS:15885 (part-II section 13) suitable for LED street light of 50-90 watt outdoor dry and damp application after taking down the street light from pole/wall and refixing the street light on pole/wall (Size of driver should be as per sample given by Engr -in-charge complete all as specified and directed. 66 Supply, install and testing in repair LT Feeder pillar panel cubical outdoor type made out of CRCA sheet 3.00mm front hinged openable door includinglocking arrangement, platform mounted with angle iron 40mmx40mmx5mm frame work suitable for 240 volts grade three phase 4 wire 50 Hz AC Supply system, having bus bar chamber with suitable aluminium bus bar 100 Amp rating and accomodated with 63 Amp MCB TPN, with astronomical digital24 Hr timer, contactors of suitable ratingand making all necessary electrical connection complete, the box shall be dust and vermin proof IP-54 class protection alongwith in built short circuit protection conforms to IS/IEC 60947-4-1 complete all as specified and directed. 67 Supply & fixing in repairs of Automatic Street Light Control Switch suitable for Three Phase with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 30/60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP66. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor and VMS). Make of Materials:-Infrared Sensor based NATURE SWITCH : Bajaj / Healer (Model No Navdeep-66-12KW3P of Navdeep Series)Circuit Wiring :- Polycab/FinolexContactor : Siemens/L&T/BCHMCB : L&T / Legrand / HagerJunction box : Hensel / GE or equivalent 68 Supply & fixing in repairs of Automatic Street Light Control Switch suitable for Single Phase with Infrared Sensor based NATURE SWITCH & Voltage Monitoring System (VMS). Nature Switch operation should be based on Natural Light Lux level. Required Illuminance Level for Switching ON is ≤ 30/60 Lux and for switching OFF ≥ 10 Lux. The Sensor should also have part night operation facility of min. 4 to max. 12 hrs. VMS should have Adjustable Over & Under Voltage Trip level and Protection against Phase Loss, Neutral Loss & Phase Reverse. The Sensor & VMS along with suitable Power Contactor(s) and Incoming-Outgoing MCBs should be enclosed in a pole/wall mountable Enclosure made of Rust Proof, Electric Shock Proof, Termite proof and FR grade SMC Junction box conforming to IP66. The circuit should also have provision for Manual Operation (i.e. By-Pass Option for both Sensor and VMS). Make of Materials:-Infrared Sensor based NATURE SWITCH : Bajaj / Healer (Model No Navdeep-66-5KW1P of Navdeep Series)Circuit Wiring :- Polycab/FinolexContactor : Siemens/L&T/BCHMCB : L&T / Legrand / HagerJunction box : Hensel / GE or equivalent 69 M&L for earthing complete with galvanised steel earth plate electrode 600mm X 600mm X 6mm thick buried directly in ground vertically earth pit not less than 2.25 meter deep below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to GI earthstrip of size 32x6 mm as earthing lead by means ofbolts, nuts and washers all as shown in electrical plate No 3 of MES Scedule part I (2009)withconected to eath test point including adequate quantity of charcoal dustand comman salt, PCC (1:3:6) type C-1chamber andfor earth pit with 40x40x6mm mild steel angle iron frame for cover. precast RCC cover 40mm thick (1:2:4) type B1 using 20 mm graded stone aggregate reinforced with 8 mm dia round bars both wayswith MS handle 8 mm dia. PGI funnel and wire mesh 20 mm dia GI pipe medium grade for wateringand 40mm dia medium grade GI pipe as earth lead protection pipe completeall as specified and directed.Note: GI earth strip and protection pipe upto and including 7.5m is deemed included in unit rate quoted by contractor.

Key Value

Document Fees
INR 500 /-
EMD
INR 60000.0 /-
Tender Value
INR 30 Lakhs /-

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail