| 1 | Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in charge. |
| 2 | Cement concrete 1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) - |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 4 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 5 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources) |
| 6 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 7 | Pointing on stone work with cement mortar 1:3 (1 cement : 3 fine sand) : Raised and cut pointing |
| 8 | 15 mm cement plaster on the rough side of single or half brick wall of mix 1:6 (1 cement: 6 fine sand) |
| 9 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete |
| 10 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications : Two or more coats applied on walls @ 1.25 ltr/10 sqm over and including one coat of Special primer applied @0.75 ltr /10 sqm. |
| 11 | Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete. |
| 12 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 13 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 14 | Wiringfor circuit/submainwiring alongwith earthwire withthe followingsizes ofFRLS PVCinsulated copper conductor, single core cable in surface! recessed medium class PVC conduit as required.(1.14.3) 2x4 Sq.mm + 1x4 Sq.mm earth wire |
| 15 | 1.14.4)2x6 Sq.mm + 1x6 Sq.mm earth wire |
| 16 | Wiringfor Group Controlled (Looped)lightpoint/fan point/exhaustfanpoint/callbellpoint (without independent Switch etc) with1.5 Sq.Mm FRLSPVC insulatedcopper conductorsinglecorecable insurface/recessed PVC conduit, andearthingthepointwith 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 17 | SupplyingandfixingPVC batten/ angle holder including connections etc. as required. |
| 18 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, dinbar,interconnections,powderpaintedincludingearthingetc.asrequired.(Butwithout MCB/RCCB/Isolator). |
| 19 | Supplying and fixing 5A to 32A rating, 240/415V, 10kA, \"C\" curve, miniature circuit breaker suitable for indicative load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 20 | Supplyingandfixingfollowingrating,doublepole,240volts,isolatorintheexistingMCBDB complete with connections, testing and commissioning etc. as required. |
| 21 | 63 A, TPN, switch disconnector fuse unit (Panel mounted type) with ISI Marked HRC Fuses. |
| 22 | Centering and shuttering including struting , propping, etc. and removal of form for : Foundations, footings, bases of columns, etc. for mass concrete |
| 23 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 24 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 insuper structure above plinth level up to floor V level in all shapes and sizes in : 6.4.1 Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 25 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required : 4 x 1.5 sq. mm |
| 26 | Stone work (machine cut edges) for wall lining etc. (veneer work) upto 10 metre height, backing filled with a grout of average 12 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) including pointing in white cement mortar 1:2 (1 white cement : 2 stone dust) with an admixture of pigment matching the stone shade : (To be secured to the backing and the sides by means of cramps and pins which shall be paid for separately) :White sand stone - exposed face fine dressed with rough backing :40 mm thick |
| 27 | Providing and fixing stainless steel cramps of required size and shape for anchoring stone wall lining to the backing or securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases in stone and holes in walls wherever required. |
| 28 | Providing and fixing copper pins 7.5 cm long 6 mm diameter for securing adjacent stones in stone wall lining in cement mortar 1:2 (1 cement : 2 coarse sand), including making the necessary chases. |
| 29 | Supply and fixing of suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A mcb, modular socket outlet and 15/16 A modular switch, connection etc. as required. |
| 30 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. : In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 31 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 32 | SupplyingandfixingPVC batten/ angle holder including connections etc. as required. |
| 33 | Wiringforlightpoint/fan point/exhaustfanpoint/callbellpoint with1.5 Sq.Mm FRLSPVC insulatedcopper conductorsinglecorecable insurface/recessed mediumclassPVC conduit,withmodularswitch,modularplate,suitablemodularboxandearthingthepointwith 1.5 Sq.Mm FRLS PVC insulated copper conductor single core cable etc. as required. : Group- A |