Tender For Provision Of Electrical Installation In Quarter No.E-18 (Type-Iv) , Municipal Flat Minto Road In Ward No. 77 Under Csp Zone.; 1 Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. 2 Group-B 3 Rewiring for light point/fan point/exahust point/call bell point with1.5SQmm FRLS PVC insulated copper conducter S/c cable and1.5 sq.mm.FRLS PVC insulated copper conductor S/C cable as earth wirein existing surface/recessed steel /PVCconduit,i/c dismentling asrequired. 4 Group-B 5 S&D following sizes of FRLS PVC insulated copper conductor,S/C cable in theexistying surface/recessed steel/pvc conduit as reqd. 6 3x2.5 sq.mm 7 6x2.5 sq.mm 8 3x4 Sqmm. 9 3x6 Sqmm. 10 Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 11 25 mm 12 Supplying and fixing metal box of 180mm X 100mm X 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required. 13 Supplying and fixing suitable size G.I box with Modular Plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps. modular socket outlet and 5/6 amps modular switch, connections, painting etc.as required. 14 Supplying and fixing suitable size G.I box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps modular switch, connections, painting etc.as required. 15 Supply & Fixing following size/module,GI box alongwith modular base & cover plate for moduler switches in recess etc.as reqd. 16 6 Module (200 mm x 75 mm) 17 8 Module (125 mm x 125 mm) 18 12 Module (250 mm x 150 mm) 19 Supply & Fixing following modular switch/socket on the existing modular plate & switch box i/c connections but excluding modular plate etc.as reqd. 20 5/6 Amp.Switch 21 15/16 Amp.Switch 22 3 pin 5/6 Amp.Socket Outlet 23 6 pin 15/16 Amp.Socket Outlet 24 S & F Call bell/buzzer suitable for single phase,230 V complete as required. 25 Supplying and fixing PVC batten/ angle holder including connection etc.as reqd. 26 S & F metal box of following size (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front i/c painting etc. as reqd. 27 200mm. X 150 mm.x 60 mm.deep 28 Installation of exhaust fan in the existing opening,including making good the damage,connection,testing & commissioning etc.as reqd. 29 Upto 450 mm sweep 30 Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 31 8 way, Double Door 32 12 way, Double Door 33 Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,10 KA C curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. 34 Single pole 35 Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 36 40 amps 37 63 amps. 38 Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 A C curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. 39 Supply, Installation, Testing and Commissioning of ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. metal (Aluminum alloy) blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, steel/Al body Power Factor not less than 0.9,Service Value (CM/M/W) minimum as below, 350 RPM (tolerance as per IS : 374-2019), THD (Total Harmonic Distortion) less than 10%, remote (preferably mobile app based) for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Ceiling Fan compliant to IS 374:2019 fan Supply, earthing etc. complete as req (a)1400mm, service value ≥ 6.0 CM/Min/Watt, air delivery 245 CM/Min (Minimum) 40 Supplying, installation, Testing & Commissioning of LED surface mounted Batten light of following body material and construction as per IS : 10322 with driver (Replaceable) as per the requirement with Driver efficiency >85% ,Operating voltage AC 140-270 Volt, freq 50/60 hz, Operating temp range -15 deg to 40 deg centigrade, internal surge protection of 2.5 KV with Short & Open circuit protection ,THD < 10% , P. F.≥0.95, IP20, CRI >80,Flicker free, (flicker should be below 5 %), life time (LED,Driver & electrical circuitary), of minimum 50000 Burning Hours with , 70% of initial Lumen maintained till life ends, CCT 3000°K / 4000°K / 5700°K /6000°K/6500°K (As per ANSI Bin), SDCM (Standard Deviation Color Matching) <3, Maximum power consumption should not more than the specified rating and Fixture shall be of relevant BIS standard and trade mark certificate ( T.C.). Manufactures Word Mark/ Name Engraved/ Embossing/ Screen printing on housing. complete in all respect i/c connections with 1.5 sq mm FRLS, PVC insulated copper conductor single core cable and earthing etc. as required with Minimum 5 year OEM warranty. System lumen efficacy ≥105 <120 lm/Watt output . LM79 & LM80 Test report from NABL lab for all testing required for LED fixtures as per BIS shall be submitted. Shape size and CCT shall be as approved by Engineer-in-Charge as per requirement. (Thermal management: heat sink of aluminum housing such that LED junction temperature shall not riseabove 90°C). CRCA Sheet Body (Thickness ≥ 0.50 mm)(A) 18-22 W