Tender For Interior Electrification And Air Conditioning Works Of Kanjikkuzhy Branchalappuzha, Alappuzha-Kerala

Kerala State Co-Operative Bank Ltd has published Tender For Interior Electrification And Air Conditioning Works Of Kanjikkuzhy Branchalappuzha. Submission Date for this Tender is 30-07-2025. Road Work Tenders in Alappuzha Kerala. Bidders can get complete Tender details and download the document.




Tender Notice

49965147
Tender For Interior Electrification And Air Conditioning Works Of Kanjikkuzhy Branchalappuzha
Tender
Indian
Kerala
Alappuzha
30-07-2025

Tender Documents

Tender Details

Tender For Interior Electrification and Air Conditioning works of KANJIKKUZHY BranchALAPPUZHA-- 1 FURNISHING WORK - Providingand fixing false ceiling at all height includingprovidingand fixing of frameworkmadeof specialsections, powerpressed fromM.S.sheets and galvanizedwith zinc coating of 120 gms/ sqm (bothside inclusive)as per IS :277andconsistingof anglecleatsof size 25 mmwidex 1.6 mmthickwith flanges of 27 mm and 37 mm, at 1200 mm centreto centre, one flange fixed to the ceiling with dash fastener 12.5 mm dia x 50 mm long with 6 mm dia bolts, other flange of cleat fixed to the angle hangers of 25x10x0.50 mm of required lengthwith nuts& boltsof required size andotherendof angle hangerfixed with intermediate G.I. channels45x15x0.9 mm running at the spacing of 1200 mm centreto centre, to which the ceiling section 0.5 mm thick bottomwedge of 80 mm with tapered flanges of 26 mm each having lips of 10.5 mm, at 450 mm centreto centre, shall be fixed in a direction perpendicular to G.I. intermediate channel with connecting clips made out of 2.64 mm dia x 230 mm long G.I. wire at every junction, including fixing perimeter channels0.5 mm thick 27 mm high having flangesof 20mmand30mmlong, theperimeter of ceilingfixed to wall/partition with the help of rawl plugs at 450 mm centre, with 25 mm long dry wall screws @ 230 mm interval, including fixing of gypsum boardto ceiling section and perimeter channelwith the help of dry wall screwsof size 3.5x25 mm at 230 mm c/c, including jointing and finishing to a flush finish of tapered and squareedges of the boardwith recommended jointing compound, jointing tapes, finishing 2 Gypsum Step Ceiling :Providing and fixing Gypsum Step ceiling with width/ depthless than or equalto300mm as perapproved design.Frame workmadeof special sections,power pressedfromM.S.sheets andgalvanized withzinc coating of120gms/sqm (both sideinclusive) asper IS:277,ie, perimeter channels 0.5 mm thick 27 mm high having flanges of 20 and 30 mm long to be fixed as per design intentand thick 12.5 mm thick tapered edge gypsum plain board conformingto IS : 2095-Part 1 to be fixed on to theframework using 25 mm long drywallscrew.Finish the jointsusing jointing compoundand joint tap asper manufacture specification. Includingcostandconveyanceof all materials labourcharges etc.complete as per direction of Engineer-in-charge. The visible Vertical Sides will 3 Grid type false ceiling :- Providing & Fixing of grid type false ceiling with armstrong tile,Model: Classic Lite RH99 Armstrong. (Classic Lite tiles with Rivel edge black groove grid frames) and armstrong suspension system as per standard specifications of Armstrong world industries includingproviding cutouts for light 4 Toughened GlassProvidingandfixing doorof 12mmthickToughenedglassdoor(Saint Gobain) withdormaAido XLC4000patchfittings(FloorSpring, Top patch, pivotPin, Bottom patch)dormaCenter lock and handle24.Including all cost and conveyance of materials, labour, etc complete. 5 12mm Toughened Glass Partition with plywood frame :Providing and fixing 12mm thick Toughenedglass(SaintGobain) Partition System(uptoa heightof 300cm) with12mmply and1mm lamination asperdesignintent.Includingallcostandconveyance ofmaterials, labour etc complete. 6 Etching Sticker Work:Providingand fixing Etching Sticker as perdesignintentusing suitable adhesive as per manufactures Specification.Including all cost and conveyance of materials, labour etc complete. 7 Providing partition wall80mm/100mm thick using plywood of thickness12 mm doublelayer, witha plywoodcore.Finished with1mmwhiteor theme lamination onbothsides. No quantity is measured inrunning meter and Quantityismeasured onlyforpartitions belowthefalse ceiling.Including cost and conveyanceof all materials labourchargesetc. complete. 8 Supplying and fixing 4mm ACP in existing aluminiumframe work, as per the specificationsanddrawing. includingcostandconveyanceof all materials labour charges etc. complete. 9 Supplying and fixing flush doors with 32mm block boardand 6mm glass as per design and specificationfinished with 1.00 mm lamination on both sides,the widthof thedoor75cm/90cm.UseISI.S.S304hardware fittings including locks,handles,hinges,stoppers,door closer,etc. Including costand conveyance ofallmaterialslabour charges etc. complete. 10 Cladding over the pillars, and solid walls using 12mmPVC boardof 0.6 density and finished with1mm lamination, as per the specifications and drawing.including cost and conveyanceof all materials labourchargesetc. complete. 11 Supplying and fixing plywood shelves 45 CM WIDTH provide, hinges, and8 concealedhandleswithmulti-lockusing19mmblock boardfor the door. Finished with 1mm lamination on both sides. Shelves using 19mm plywoodand 12mmPVC boardof 0.6 densityfor the backside. Finished with 0.8mm lamination for the innersides and 1mm lamination for the outersides. Quantityis measured only below the false ceiling. Drawings &specifications are given along with. including cost and conveyanceof all materials 12 Making a cashcounter unitwithFramedin80mmand100mmthick partition wall including all sides of cash counter as per drawingmade in12mm double layer, with a plywood core and provides12mm toughened glass beveledandpolishedforthefrontandsides, fixedtotheside partition ofthe counter asperdesignProvidekeyboardtray,cable manager,CPU stand,leg stand,fixedinSS 304-hardwarefittings includinglocks, towerbolt, and handles. Providecurrencyreader near cashchestwithglassin tabletop andlight pointwithLED bulb, cash drawers, and shuttered cabinetswith locks and handles for the counter and19mmNanowhite granite forcountertopwithside polished.. Finished with 1mm woodenand white lamination on the outerside, and 0.8mm lamination on theinside. An etchingstickershouldbe provided forthe glassareaasspecified.Includingcostandconveyance of all materials labour charges etc. complete. 13 Making tablefortellers,manager,senioraccountent,auditor,area manager etc, as perdesignandprovide19mmNanowhitegranite for countertopwithside polished.Thecounter isframed using19mm- marineply withadrawer,shelf, keyboard tray,cablemanager ,CPU stand, leg standsusing 12mm plywood, lock,handil,hinges, etc are constructedasper design.Finished with 1mm wooden and white lamination on outersideand0.8mmon theinside. includingcostand conveyance of all materials labour charges etc. complete. 14 Making sidecredenza 80x40x60CMs using19mmand12mm-plywood Finished with 1mm wooden and white lamination -on the outersides and 0.8 mmlamination -on theinnersides.Providelocks andhandlesfor drawers and shutters as per design. Including cost and conveyanceof all materials labourcharges etc. complete. 15 Making apaper deskforthecustomers65x40x50cms indimension dimension with a 19mm nano white for the tabletop. All faces of the table using 12 mm plywood, finished with 1mm lamination. Including cost andconveyance of all materials labour charges etc. complete. 16 Supplying and fixing zebrablindsself-designedor textured of standard quality (approximatecost(total work)160/sqft).Including costand conveyance of all materials labour charges etc. complete . 17 Supplying and fitting ready made pin-up notice board(120x90)cmswith aluminium frameandvelvetcoreincludingcostofmaterials,fitting charges etc. complete 18 Supplyingandfitting8mmthickglasswithvinylesticker walllogoboard(120x60)cms fixing to wall or partition using by ss studs. including cost of materials, fitting charges etc. complete 19 Pantry Counter, :- Providing table type pantry counters 60 cms wide, 75 cms height, with table top, front apron, vertical dividers19 mm BWR 303 grade plywood.5x3 cm wooden frame to be given horizontally below inner edge of counter top for the entire length of the counter.Wooden foot rest of 7.5 x 3 cm size .Counter top to be provided with 20 mm edge bevelled and edge polished granite (jet black). All external surfaces 1 mm laminate finish and internal surfaces with enamel finish. 10mm thick beach wood lipping for all plywood edges. 20 Wicket doors with Both side Mica:- Providing and fixing 30 mm thick single leaf solid core and resin bonded flush door water proof quality with 1 mm thick lamination on both sideexternal wooden lipping all round the shutters, all as per drawing and instruction. the doors and lamination of approved make, colour anddesign including all best quality hardware, brass hinges, locketc;. complete. 21 Door closer: Supplying and fixing everite make hydraulic door closer includingcost and conveyance of all materials, labour charges for fixing, etc. complete as per directions of site incharge. 22 Dressing table -Supply/ installing wall mounted dressing table with glass mirror as per detailed drawing. Outer sides should be laminated and inner sidespainted withtwo coats of enamel paint over a coat of primer & two coats of putty. (Size of table with mirror-50x45x140) 23 Floating glass shelf for trophy in Managers room :- Providing 12mm thk edge polished glass shelves of size 100cms length and 20cms width fixed to the Back wall in Managers cabin using adjustable glass shelf supports of SS finish (EBCO/eqlt) The spacing between the glass supports shall be 40cms or as permanufacturers specification. 24 ELECTRICAL WORKS 25 1 - Main VDB - Supply and installation of sheet steel, phosphatisedandpainted,dustandvermin proof enclosure of 6 way (8+18 -double cover TPN vertical DB with provision for fixing FP MCCB as incomer and SP/ TP MCB as outgoings (IP 42/43) including copper /brass bus bar, neutral link, earth bus and DIN rail suitable forfixingMCB/ isolatoretc.fixedonwall using suitable anchor bolts or fixed in recess includingcuttinghole onthe wall , making goodthedamages, colourwashingetc.as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. 26 Main Incomer - Supplying and fitting 100A 4P 35kA 415V 50Hz MCCB with Thermal Magnetic Protection Unit conforming to IS60947-2 & IEC 60947-2. 27 Outgoings - Supplying and fitting 63A 3P 415V 50Hz MCB 10kA C curve conforming to IEC 60947-2. For A/CDB & SPARE 28 Supplyingandfitting25/32A3P415V50HzMCB 10kA C curve conforming to IEC 60947-2 For 3phase ups/LDB/ATM 29 Supplyingandfitting32/16ASP240V50Hz MCB 10kA C curve conforming to IEC 60947-2.For board light and spare 30 2- AC/DB - Supplyandinstallationchargesof3phase 4way(8+12)DB enclosurewithbusbars, neutral link earth bus and din rail suitable for fixing 4P MCB AND RCCB as incomer and SP MCBasoutgoings IP43includingcopper/brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB etc. fixed on wall using suitable anchor bolts or fixed in recess includingcuttinghole onthe wall , making goodthedamages, colourwashingetc.as required Conforms to IS 8623 - 1&3, IEC 61439- 1&3. 31 Incomer - 63A 4P RCBO (100mA)conforming to IEC/EN 61009 2010 32 Outgoings - Supplyingandfitting10/16ASP240V50Hz MCB 10kA C curve conforming to IS/IEC 60898-1 2002. For power plugs 33 Supplyingandfitting20/25ASP240V50Hz MCB 10kA C curve conforming to IS/IEC 60898-1 2002. For single phase A/C Units 34 LDB - Supply and installation charges of 3 phase 4 way(8+12)DB enclosurewithbusbars, neutral link earth bus and din rail suitable for fixing 4P MCB AND RCCB as incomer and SP MCBasoutgoings IP43includingcopper/brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB etc. fixed on wall using suitable anchor bolts or fixed in recess includingcuttinghole onthe wall , making goodthedamages, colourwashingetc.as required Conforms to IS 8623 - 1&3, IEC 61439 - 1&3. 35 Incomer - 40A (30mA) 4P RCBO conforming to IEC/EN 61009 2010 36 Outgoings - Supplying and fitting 10/6A SP 240V 50Hz MCB 10kA C curve conforming to IS/IEC 60898 -1 2002. 37 UPS -Phase selector Switch for UPS Input:-40A 4P MCB and 40A PhaseSelector switch without off in metalic enclosure 38 UPS IP DB : SITC of6 Way double doorSPNDB consisting of thefollowing for UPS 39 40A 2P RCBO (30mA) as incomer32 A 2P MCB - 2 Nos 40 NOTE: The complete alarm systems and CCTV systems power connections must be taken before the output MCB of the UPS connection to ensure continuous power supply to the security systems. separate MCB to be provided near CCTV, Fire Alarm System power points. 41 UPS OUTPUT:- SITC 32 A DP MCB in metallic enclosure 42 UPSOUTPUT SUBDB:SupplyandinstallationchargesofSingle phase12way(I/C+O/G)DBenclosurewith bus bars, neutral link earth bus and din rail suitable for fixing 2P ISOLATOR as incomer and SPMCBasoutgoingsIP43including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts orfixedinrecessincluding cuttingholeon the wall , making good the damages, colour washing etc. as required Conforms to IS 8623- 1&3, IEC 61439 - 1&3. 43 40A 2P HI RCBO (30mA) - 1no as incomerand followingas out goings 44 10A SP MCB - 10 No ( for CKT & Spare) 45 INVERTER - INVERTER CIRCUITSupply, Installation, testing and commissioning of Inverter input & output using 3 x2.5sqmm 1100V, PVC insulated FRLSH Copper conductor through PVC Conduit .Rate shall be for the average length from VDB to inverter charging, then to inverter input, from inverter output to inverter discharging & connection to change over and to inverter DB.No claim for additional wire and conduit.Following isolators to be provided for inverter charging (input)and discharging (output) 46 (a) 25A DP ISOLATOR inmetal enclosure for inverter charging 47 (b) 25A DP ISOLATOR inmetal enclosure for inverter discharging 48 SITC of 25A 2P MCBType manual Change over switch In metalenclosure with necessory fittings 49 CONTROL SWITCH (CCTV) :-SITC of 16A Modular switch box withsocket and MCB 50 LIGHTING DB CUTOFF - Supply, Installation, testing and commissioning 40A 4P MCB IN 4 WAY SPN DB AT ENTRANCE OF BRANCH 51 INVERTER DB : SupplyandinstallationchargesofSingle phase12 way(I/C+O/G)DBenclosurewith bus bars, neutral link earth bus and din rail suitable for fixing 2P ISOLATOR as incomer andSPMCB asoutgoingsIP43including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts orfixedinrecessincludingcutting holeon the wall , making good the damages, colour washing etc. as required Conforms to IS 8623- 1&3, IEC 61439 - 1&3. 52 40A 2P RCBO (30mA) as incomer 53 10A SP MCB -10Nos 54 Supply &Installation of SURGE PROTECTION DEVICE (TVSS ) - Surge protection device(AC) 3P+N, In-20Ka,Imax -40kA,Up-less than or equal to 4.5kV ,with indicator conforming to IEC/EN 61643-11 55 POWER CABLE: Supply & laying of XLPE insulated PVC innersheathed aluminium conductor, 1.1 kV grade armoured power cables conforming to IS:7098, as per approved make in ground/trench/surface/wall/pipe,(a) 4x35 Sq.mm XLPE as incoming cable MSBto VDB 56 (b) 4x10 Sq.mm XLPE VDB to Light Cutoff and return to LDB 57 ( c ) 4x16 Sq.mm XLPE VDB to To POWER/AC DB 58 (d)2x4Sq.mm XLPE 59 CABLE TERMINATION Supply and installation (SITC) of End termination of the following size of cables using flange type cable glands and heavy duty tinned aluminium crimping type cable socketsincluding gland earthing. 60 (a) 4x35Sq.mm XLPE 61 (b )4x16Sq.mm XLPE 62 (c ) 4x10 Sq.mm XLPE 63 (d ) 2x4Sq.mm XLPE 64 Supply & laying of 4 x 6sq. mm stranded PVCinsulated copper wirethrough 20mm Rigid PVC condute. 65 WIRING FOR LIGHT, FAN, PLUG SOCKETS, UPS & EARTHINGOFBRANCH COLOUR CODING AS PER IS 732 STANDARD. R Phase - RED COLOUR,YPhase - YELLOW COLOUR, B Phase - BLUE COLOUR WIRING SYSTEMA - Circuit Main - SITC of all materials and wiring for circuit mains from LDB/Inverterto Switch Boards, using 2.5 sq mm 1100V, PVC insulated FRLSH Copper conductor for phase , neutral includingearthingwith1 run of 2.5 sq.mm green copper wirecontinuous run thorough 25 mm PVC conduit as per IS, giving inter connection etc complete as required and as directed by engineer in charge.Rate shall be for the average length from LDB to the switch board.No claim for additional wire and conduit. 66 B - Light And Exhaust fan Points -SITC of all materials and wiring forlight and exhaust fan points using color coded 1.5 sq.mm 1100V grade, FRLSH, PVC insulated stranded copper conductor single core stranded wires of IS 694 specification and should have IS marking, through ISImedium grade20mm rigid PVC conduits concealed in wall / slab/ceiling etc,complete with necessary accessories, including supplying and fixing 6A modular type switch housed in a suitable factory made M. S box with moulded front plate including earthing the box, ceiing rose, connectors (of approved make) etc., complete as required.(The rate include removing debris,packing and rough plastering the grews after conduiting) (b1) Single control light Point / Exhaust fan point (one light/fan controledby one switch) Item rate 67 C - Group Control Wiring (Lights) (c1) Two lights controlled by one switch Item rate 68 ( c2 ) Three lights controlled by one switch Item rate 69 (c3) Four lights controlled by one switch 70 Item rate 71 D - Supplying all materials and wiring for ceiling fanpoints with 250 W stepped type electronic regulator using 1.5sq.mm, FRLSH PVC insulated stranded copper conductor single corestrandedcolor coded wires of 1100V grade and 1 run of 1.5 sq.mm green copper wirefor Phase , nuetral &earthing continuously run as per IS through ISI medium graderigid PVC conduits concealed in wall/slab/ceilingetc., complete with necessary accessories, including supplying and fixing 6A modulartype switch and 250W electronic fan regulator housed in a suitable factory made M. S. box with moulded front plate including earthing the box,complete as required.(The rate include removing debris, packing and rough plastering the grews after conduiting) 72 (d1) Ceiling fan point Item rate 73 ( d2) Wall fan point (same as above ) with 6A socket but without electronicregulator Item rate 74 E - Plug Sockets 75 (e1) Supplying all materials and wiring for 6A plug points in independent positions using 1.5 sq.mm 1100V, FRLS PVC insulated copper conductor single core stranded wire for phase & neutraland earthing with1 run of 1.5 sq.mm green copper wireinside the conduit / flat conduit,and fixing 6A modulartype plug socket (2 in 1) controlled by 6A switch with moulded front plate, housed in a suitable factorybuilt MS box.Giving connections, earthing etc complete as required.Item rate 76 (e2) Supplying all materials and wiring for 6A plug points in combined positions using 2 runs of 1.5 sq.mm 110V FRLS PVC insulated copper conductor single core stranded wire, earthing with earthing with1 run of 1.5 sq.mm green copper wireinside the conduit/flat conduit ,and fixing 6A modulartype plug socket (2 in 1) controlled by 6A switch with moulded front plate, housed in a suitable factory built MS box.Giving connections, earthing etc complete as required. (in SB)Item rate 77 (e3) Supplying all materials and fixing modular type 16A power plug point with 16A 3 pin modular type plug socket controlled with16A switch withmoulded front plate, housed in a suitable factory builtMS/PVC box using 2 runsof 2.5 sq mm 1100V , FRLSH PVC insulated stranded Copper conductor includingearthingwith1 run of 2.5 sq.mm green copper wirecontinuous run thorough 25 mm PVC conduit as per IS, giving inter connection etc complete as required and as directed by engineer in charge. as per IS, giving inter connection etc complete as required. Rate shall be for the average length from DB to the switch board.No claim for additional wire and conduit. Item rate NOTE: The Electrical Wiring inside the Strong Room should be in a CONDUIT and POWER CUT OFF SYSTEM either AUTO/ MANUALPLUG SYSTEM drawing power only from the Limit Switch in case of Auto Power Cut Off System is provided in the Door OR from the FEEDER BOX fitted outside the Strong Room (near the door) in case of Manual Plug System. The MANUAL PLUG SYSTEM OF POWER CUT OFF should be such that the connecting cable passes through the Strong Room Defender Door from inside to outside, which should be accessible only after opening the S.R.door (thus ensuring that the door can not be closed withoutremovingthe plug + wire and hence total power inside the Strong Roomis cut off leaving no chances of fire resulting from anElectrical source / High Voltage / Surgingeven with the Switches in Off position). Inverter & KSEB Power inside strong room should be provided through two separate plug and socketarrangements. 78 F - Computer power point - UPS power stations Supplying all materials and fixing modular type 3numbers 6A, 3 Pin sockets controlled by one number 16A SP control indicatorswitch with moulded front plate, housed in a suitable factory built MS/PVCboxSITC of all materials and wiring for circuit mains from UPS Sub DB to work station using 2 runs of 2.5 sq mm 1100V, FRLSH PVC insulated stranded Copper conductor includingearthingwith1 run of 2.5 sq.mm green copper wirecontinuous run thorough 25 mm PVC conduit as per IS, giving inter connection etc complete as required and as directed by engineer in charge. etc complete as required .Rate shall be for the average length from DB to the primary switch board and looping to adjacent switch boards. No claim for additional wire andconduit. (Maximum 2 points from 1 Circuit) 79 H -1 TonA/C Point Supplying all materials and fixing modular type 20 A power plug pointwith 20A 3 pin socket controlled with 20 A DP modular switchwith moulded front plate, housed in a suitable factory built MS box using 4 sqmm 1100 V, FRLS PVC insulated strandedCopper conductor and earthing with 4 sqmm green Cu wire continously run through25 mm PVC conduit as per IS giving inter connection etc complete as required.(AC point) the switch shall be fixed at a height of 120 cm from finished floor level .Rate shall be for the average lengthfrom DB to the switch board. No claim for additional wire and conduit. Item rate 80 I - 2 Ton/1.5 TON A/C PointSupplying all materials and fixing modular type 32 A power plug pointwith 32A 3 pin socket controlled with 32 A DP modular switchwith moulded front plate, housed in a suitable factory built MS box using 2 runs4 sqmm 1100V FRLS PVC insulated Copper conductor and earthing with 2.5 sqmm green Cu wire continously run through25 mm PVC conduitas per IS giving inter connection etc complete as required.(2 Ton AC point) the switch shall be fixed at a height of 120 cm from finished floor level. Rate shall be for the average length from DB to the switch board.No claim for additional wire and conduit.Item rate 81 J -CASSETTE AC POINTSupplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 30 A C curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete withconnections, testing and commissioning etc. as required. 82 K -Weather proof IP 65 enclosure for AC outdoor control(to be providedafter obtaining approval from Bank) 18 - STABILIZER (a) SITC of 4/5 KVA , V Guard make voltage stabilizer 83 (b) Supply and fixing 20A plug socketWith plug top for AC Stabilizer 84 19- Board Light PointSupplying all materials ,Wiringfor board light pointcontrolled by 20AELCBin metal enclosure using 2 runs4 sqmm 1100V FRLS PVC insulatedCoper conductor and earthing with 4 sqmm pvc insulated green Copper wire continously run through25 mm PVC conduitas per IS giving inter connection etc complete as required. Rate shall be for the average length from DB to theboard light .No claim foradditional wire and conduit. (Board Light point for Branch) 85 20- SITC OF LIGHT FITTINGS AND FANS 86 (a ) 36W LED FITTING- Supply and Installation of2x2 square LEDceiling flush mountedfitting of Wipro, Elate LED,CRCO10 87 (b) ROUND LED DOWN LIGHT FITTING Supply and Installation of LED ceiling fittingWipro Iris LED Slim Ro, LD80-171-XXX-60-XX 1x18W 88 (c ) ROUND LED FITTING Supply and Installation of LED ceiling fitting Wipro Iris LED Slim Ro, LD80-530-XXX-60-XX 1x9wor equivalent 89 (d) CALLING BELL Supply and Installation of Calling bellcontrolled bymodular type bell push 90 (e ) LED TUBE FITTING Supply and Installation of 1x18 W patty LED tube fitting on wall or ceilingGarnet led tube 4feet white 91 ( f) LED bulb - Supply and Installation of 9W LED bulb on angle holder. 92 (g ) WALL FAN Supply and Installation of400 mm sweepswivelling typewall fan Crompton Greaves High flo or equivalent 93 (h) EXHAUST FAN Supply and Installation 150mm light dutyexhaust fanwith all fittings 94 (i) EXHAUST FAN Supply and Installation 300mm light dutyexhaust fanwith all fittings 95 (j) CEILING FAN Supply and Installation of 1200 mm sweepceiling fan with all fittings for the installation of Ceiling fan - Crmpton Greaves -white color 96 (k) CABIN FAN Supply and installation of 300mm sweep cabin fan withplastic body & blade with Grill for protection and can be mounting on ceiling.(l) LED STRIPSupply and fixing strip LED (Warm colour) for false ceiling with good quality driver unit (4A,12V adaptor for 5M ) Formes Led Wipro 97 (m) Supply and installation of 15W 2ft Watt LEDMirrorLampluminaire andgiving connections. 98 21 -EARTHINGSTATIONS(a) Supply and installation of plate earthing satation conforming to IS 3043 using 600x600x6mm Copper plate eath electrode burried in ground, 20mm dia 3m long perforated GI pipe with funnel and constructing inspection chamber by masonry work with heavy dutyCI inspection cover including civil work complete for UPS. 99 (b) PIPE EARTH Supplying of all materials and providing earth point with pipe earthling waste pipe earthling strips, funnel etc. excavation trenches, filling with alternate layers of charcoal, salt ands sand, back filling as per BIS specifications and IS 3043/1987 100 22- EARTHINGCONDUCTORSSupply and laying the following sizes of bare copper earthing conductors including termination,bracing the joints etc. as per standards.(a)2x10 SWG Copper through cables 101 (b)1x8 SWG Copper for pipe earth 102 (c)1x10 SWG Copper 103 23- EARTH BENCH Supply and fixingtinnedcopper earth bench (minimum 40cm length) 25x3 mm with all termination using cu sockets etc 104 24- Prepairing Drawing and completion report for KSEB incl. liasioningwith office, submission & followup of application etc. 105 25- Supply & providing electrical grade rubber floor mats 106 26- Supply & providing cautin boards,Aluminium 105x105mm 107 27- Supply & providing electrical shock treatment chart (Three Languages -Hindi-English-Malayalam ) 108 28- Supply & providing First Aid Kit 109 III - TELEPHONESupply and wiring using 2 pair telephone cable in 20/25mm mediumduty ISI PVC pipe with all necessary pvc accessories(a)2 pair telephone cabling 110 (b)Supply and fixing of RJ 11 type telephone socket on suitable PVC /metal boxes.(i)Telephone socket – single modular type 111 (ii)Telephone socket – double modular type 112 (c )Supply, laying commissioning of 0.5 sq.mm 10 pair armouredtelephone cable with all accessories 113 (d)Supply and installation of KRONE connector telephone junction box of20 pair. 114 IV - NETWORKING 1 -Supply & drawing of CAT-6 UTP 4pair network cable in suitable size heavy duty PVC conduit and conduct accessories (maximum 2runs of cable in 20mm PVC pipe. Maximum 4runs of cable in 25mm PVC pipe) (a) CAT-6 UTP 4pair network cabling Excluding the cost of pvc pipe andaccessories 115 2- PVC CONDUIT LAYING Supply & laying of 20/25mm medium duty ISIPVC pipe with all necessary pvc accessories excluding the cost of circuit(a) 20mm ISI (M) 116 (b) 25mm ISI (M) 117 3- Supply & fixing of single I/O Box with face plate and connections 118 4- Supply & fixing of 24port Patch panel.The rate inclusive ofterminations and interconnections. 119 5- Supply and fixing 9U rack of (APW or NETRECK) make with 5 power strip.The rack shall have ventilation fans & locking arrangements. 120 6- Supply and providing patch chord with CAT 6 UTP 4pair cable min. 1mlength. 121 7- Supply and providing patch chord with CAT 6 UTP 4pair cable min. 2mlength. 122 Dismantling Existing fittings, wiring after stage wise progress of work and stocking of serviceable material and disposal of unserviceable material from the site as directed by the bank official.And Making Temporary arrangement for UPS point, lighting and fan, data points for smooth banks functioning including cost of materials. (if any) 123 that the door can not be closed without removing the plug + wire and

Key Value

Document Fees
INR 2000 /-
EMD
INR 54500.0 /-
Tender Value
Refer document

Attachment

FileName File Description File Size
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Click here to download tender document Tender Documents 0 KB
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail