Tender For Construction Of Mini Power Pump At 7Th Ward Pattankulam Street In Thalanayar Town Panchayat, Nagapattinam District; 1 Earth work excavation for foundation and depositing on bank for refilling within an initial lead of 10.00 m and an initial lift of 2.00 in hard stiff clay. Stiff black cotton soil, hard red earth, sales, murrams, gravel, stoney earth, earth mixed with small sized boulders and hard gravelly soil and except hard rock requiring blasting including shoring, strutting, bailing water wherever necessary and all other incidental charges etc., complete as directed by departmental officers as per S.S.20B 2 Plain Cement Concrete 1:4:8 mix, (one part of cement, five part of sand andeight part of aggregate) mix using 40mm ISS HBG metal from approved Quarry including cost and conveyance of all materials and all labour charges for mixing, laying, compacting and curing the concrete and other incidental charges etc., complete.as per standard specification 28 V,VI S25 3 Centering for soffits of RCC and PCC slabs of plane surface like lintels, beams, etc., including strutting 3m high using mild steel sheets of size 90cm x 60cm x and BG 10 stiffened with MS angles of size 25mm x 25mm x 3mm laid over silver oak joists of size 10cm x 6.5 cm spaced at about 90 cm c/c and supported by consurina props of 10 cm to 13cm dia spaced of 75cm c/c complying with standard specifications and as directed by the departmentsl officers etc., complete 4 Reinforced Cement Concrete 1:1.5:3 (One part of cement one and half part of fine aggregate and three part of course aggregate) mix using 20mm HBG ISS metal for all RCC items of works excluding centering and shuttering and cost of reinforcement grill but including curing the sameand also fixing fan clamps and fixtures in RCC works whereever necessary as directed by the departmental officer etc., complete 5 Supply and fabrication of steel and placing in position MS/Ribbed tor steel grills for RCC works as per design given including cost of steel and GI binding wire in all floors etc., complete complying with standard specificationsas directed by the departmentsl officers 6 Brick work in cement mortar 1:5 (one part of cement and five part of Sand)mixusing Country bricks of size 8 3/4 X 4 3/4X 2 including cost and conveyance of all materials andall labour charges and other incidental charges to site etc., complete as per standard specification. 7 Plastering in C.M. 1:5 mix (one part of cement and five part of Sand) 12mm tk including mixing and finishing to a well smoothened surface, watering cost and conveyance all materials and all labour and other incidental charges and other incidental charges etc., complete.as per standard specification TNBPSS 56,57 8 Ceiling Plastering with C.M.1:3 (One part of cement and three part of sand) mix using 10mm thick including cost and conveyance of all materials and labour charges for packing, providing cement mortar beading, for sunshades staircase steps, lands slabs ete., complete complying with standard specifications as directed by the departmental officers 9 Daddoing with Glazed tilesof approved quality set in cement mortar 1:2 mixand laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer.The colour & quality of tiles should be got approved by Municipal Engineer before use on work 10 Supplying and fixing ofSteel door and gate using ISA Sections and MS Sheet ofapprovedqualityincluding cost andconveyance of all materials and labour chargesand other incidental charges to site etc., complete.as per standard specification 11 Supply and fixing of 2000 litre capacityHDPETank of approved quality including cost and conveyance of all materials andall labour charges and other incidental charges to site etc., complete as per standard specification. 12 Wiring with 2x1.5sqmm (22/0.3) PVC insulated unsheathed SC Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC Accessoires with TW switch box and 5A F.T. switch in flush with wall with 3mm thick hylum sheet cover for making good of the concealed portion with suitable colour for PVC concealed light point / fan point (For electronic regulator) (SD.NO.24) 13 Supply and fixing of Bulkhead fitting of approved qualityincluding cost and conveyance of all materials andall labour charges and other incidental charges to site etc., complete as per standard specification. Sd 83 14 Supply and fixing of following PVC ,GI Pipe and specialsincluding cost andconveyance of all materials and labour chargesand other incidental charges to site etc., complete.as per standard specification 15 32 mm UPVC Super thick Pipe 16 25mmGI Tank nipple 17 25 mm GI TEE 18 1 X 3/4 GI Reducer TEE 19 1 X 3/4GI Reducer elbow 20 25 mm GI Elbow 21 25 mm GI Hex Nipple 22 20 mm tap 23 Supply and fixing of 16 Amps DP Switch with metal clad of 500 V with fuse and neutral (Side Handle) on suitable TW Box PWD Earthing (SD.NO.141) 24 Supply and run of 2 of 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V on 7/20 GI bearer wire for service connection mains (SD.NO.66) 25 Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable pipe on wall and ceiling with PVC accessories with 150 mm x 100 mm x 63mm TW switch box for 15 A 3 pin non inter locking CS plug with painting of suitable colour, with continuous earth wire connection of 14 SWG TC wire for open PVCplug point. (SD.NO.39) 26 Supplyand delivery ofSingle phase Centrifugal Mono block Pumpset of 150 lpm 20 m Head with ISI mark as per IS 9079/1989 with suitable Panel board includingcost and conveyance all materials and all labour and other incidental chargesetc., complete.as per standard specification 27 Supply and fixing of2.50 Sqmm three core flat type copper cable with ISI mark694/1990 includingcost and conveyance all materials and all labour and other incidental chargesetc., complete.as per standard specification 28 Labour charges for the erection of submersible pumpset in borewell/openwell including fixing and jointing submersible cable withproper clamps upto the starter to required depth and also fixing of riser pipes to the required depth valves erection clamps, pressure gauges upto the exterior wall of pump room and erection of panel board consisting of TPICN switches starter, voltmeter, Ammeter, three pilot (indicating) lamps capacitor single phasing preventor, water level guard and laying and jointing the cables and twin earthing as per IE rules etc., complete and testing the pumpset and trail run for 10 days. 29 Painting two coats with Enamel paint of approved colour and quality including cost andconveyance of all materials and labour chargesand other incidental charges to site etc., complete.as per standard specification 30 Supply and Erection of 1200 mm dia RCC Ring of approved quality to require depth including cost andconveyance of all materials and labour chargesand other incidental charges to site etc., complete.as per standard specification 31 Plain Cement Concrete 1:2:4 Mix (one Part of cement, two Part of M- Sand and four Part ofaggrigate) using 20mm size ISS HBG metal machine crushed from approved quarry including cost and conveyance of all materials to site, loading and unloading charges and labour charges for mixing, laying and curing etc., complete as per TNDSS NO: 28 & VI (S2) VI (S5A) VII standard specifications as directed by Engineer incharge.